Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 28(Pt 3): 688-706, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33949979

RESUMO

The high-precision X-ray diffraction setup for work with diamond anvil cells (DACs) in interaction chamber 2 (IC2) of the High Energy Density instrument of the European X-ray Free-Electron Laser is described. This includes beamline optics, sample positioning and detector systems located in the multipurpose vacuum chamber. Concepts for pump-probe X-ray diffraction experiments in the DAC are described and their implementation demonstrated during the First User Community Assisted Commissioning experiment. X-ray heating and diffraction of Bi under pressure, obtained using 20 fs X-ray pulses at 17.8 keV and 2.2 MHz repetition, is illustrated through splitting of diffraction peaks, and interpreted employing finite element modeling of the sample chamber in the DAC.

2.
Science ; 357(6349): 382-385, 2017 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-28751605

RESUMO

High pressure promotes the formation of polyhydrides with unusually high hydrogen-to-metal ratios. These polyhydrides have complex hydrogenic sublattices. We synthesized iron pentahydride (FeH5) by a direct reaction between iron and H2 above 130 gigapascals in a laser-heated diamond anvil cell. FeH5 exhibits a structure built of atomic hydrogen only. It consists of intercalated layers of quasicubic FeH3 units and four-plane slabs of thin atomic hydrogen. The distribution of the valence electron density indicates a bonding between hydrogen and iron atoms but none between hydrogen atoms, presenting a two-dimensional metallic character. The discovery of FeH5 suggests a low-pressure path to make materials that approach bulk dense atomic hydrogen.

3.
Med Phys ; 35(7Part3): 3415-3416, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28512907

RESUMO

Visualization and quantification of biological processes in mice, the preferred animal model in most preclinical studies, require the best possible spatial resolution in positron emission tomography (PET). A new 64-channel avalanche photodiode (APD) detector module was developed to achieve submillimeter spatial resolution for this purpose. The module consists of dual 4 × 8 APD arrays mounted in a custom ceramic holder. Individual APD pixels having an active area of 1.1 × 1.1 mm2 at a 1.2 mm pitch can be fitted to an 8 × 8 LYSO scintillator block designed to accommodate one-to-one coupling. An analog test board with four 16-channel preamplifier ASICs was designed to be interfaced with the existing LabPET digital processing electronics. At a standard APD operating bias, a mean energy resolution of 27.5 ± 0.6% was typically obtained at 511 keV with a relative standard deviation of 13.8% in signal amplitude for the 64 individual pixels. Crosstalk between pixels was found to be well below the typical lower energy threshold used for PET imaging applications. With two modules in coincidence, a global timing resolution of 5.0 ns FWHM was measured. Finally, an intrinsic spatial resolution of 0.8 mm FWHM was measured by sweeping a 22Na point source between two detector arrays. The proposed detector module demonstrates promising characteristics for dedicated mouse PET imaging at submillimiter resolution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...