Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
MEDICC Rev ; 23(2): 64, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33974603

RESUMO

The HIV/AIDS epidemic is an ongoing threat to public health. Its elimination requires greater efforts to broaden antiretroviral treatment coverage, availability and personalization. HIV drug resistance is currently a global problem due to its continuing increase in recent years, undermining efficacy of antiretroviral therapy. Pretreatment HIV drug-resistance surveillance is part of WHO's strategy for addressing antiretroviral drug resistance. This paper describes and analyzes pretreatment HIV drug-resistance surveillance in Cuba. It presents a chronology of HIV resistance studies in untreated patients, along with their results and programmatic actions related to first- and second-line treatment regimens. Cuba's incorporation into the Global HIV Drug Resistance Surveillance Laboratories Network and the advantages of having a WHO-designated laboratory in which to conduct periodic studies of HIV drug-resistance surveillance are described. HIV drug-resistance surveillance in Cuba is a necessary tool in HIV/AIDS monitoring and control, as it obtains population-scale data used to inform programmatic decisions related to optimizing first- and second-line treatments for children and adults, as well as helping meet goals of eliminating HIV transmission.


Assuntos
Farmacorresistência Viral , Infecções por HIV/epidemiologia , Infecções por HIV/virologia , Adulto , Fármacos Anti-HIV/uso terapêutico , Criança , Cuba/epidemiologia , Infecções por HIV/tratamento farmacológico , Infecções por HIV/prevenção & controle , Humanos
2.
Rev. cuba. med. trop ; 67(2): 0-0, mayo.-ago. 2015. tab
Artigo em Espanhol | LILACS, CUMED | ID: lil-769446

RESUMO

Introducción: el virus linfotrópico de las células T humanas tipo I (HTLV-I), es el agente causal de la leucemia /linfoma de células T del adulto (LLTA). Resultados hallados en estudios de pesquisa para el HTLV-I en nuestro país demuestran sin lugar a dudas la presencia del mismo en nuestra población. El DAVIH-HTLV-I es un sistema microelisa para la detección de anticuerpos contra el HTLV-I en suero o plasma humano, producido por Laboratorios DAVIH. El objetivo de este trabajo fue evaluar el desempeño del sistema DAVIH-HTLV-I con vistas a su inscripción en el Registro de Diagnosticadores, del Centro para el Control Estatal de la Calidad de los Medicamentos (CECMED), exigencia indispensable para su uso en nuestro país. Métodos: se emplearon cuatro paneles de muestras en los estudios de: especificidad, sensibilidad, eficacia, concordancia con el sistema de referencia Vironostika HTLV-I/II (Biomeriéux), precisión a dos niveles: repetibilidad (intraensayos) y precisión intermedia (inter ensayos), y robustez. Resultados: la evaluación mostró los siguientes resultados: especificidad 99,84 por ciento; sensibilidad 96,49 por ciento; concordancia 96,55 por ciento, límite de detección correspondiente a una dilución de 1/256; elevada precisión intra e interensayos (CV menores que el 15 por ciento y el 20 por ciento respectivamente); sistema robusto frente a los cambios de temperatura entre 36 y 38 °C. Conclusiones: los resultados obtenidos demostraron que el sistema DAVIH-HTLV-I se puede emplear en el pesquisaje de anticuerpos contra el HTLV-I en la población cubana, por lo que se recomendó su registro en el CECMED(AU)


Introduction: The human T-cell lymphotropic virus type 1 (HTLV-I) is the causal agent of adult T-cell leukemia / lymphoma (ATLL). Screening for HTLV-I in our country has revealed its unquestionable presence in the population. DAVIH-HTLV-I is a micro-ELISA system produced by DAVIH Laboratories for detection of antibodies against HTLV-I in human serum or plasma. Objective: Evaluate the performance of the DAVIH-HTLV-I system with a view to registration in the Registry of Diagnostic Media Products of the Center for State Control of the Quality of Drugs (CECMED), an indispensable requirement for its use in our country. Methods: Four sample panels were used to study the following variables: specificity, sensitivity, efficacy, concordance with the reference system Vironostika HTLV-I/II (Biomeriéux), accuracy on two levels: repeatability (intra-assay) and intermediate accuracy (inter-assay), and robustness. Results: The following results were obtained: specificity 99.84 percent; sensitivity 96.49 percent concordance 96.55 percent; detection limit for a 1/256 dilution; high intra- and inter-assay accuracy (CV below 15 percent and 20 percent, respectively); a robust system when faced with temperature changes between 36°C and 38°C. Conclusions: Results show that the DAVIH-HTLV-I system may be used for the screening of antibodies against HTLV-I in the Cuban population. It was therefore recommended for registration with CECMED(AU)


Assuntos
Humanos , Ensaio de Imunoadsorção Enzimática/métodos , Vírus Linfotrópico T Tipo 1 Humano , Testes Obrigatórios/métodos , Sensibilidade e Especificidade , Anticorpos
3.
Rev. cuba. med. trop ; 67(2)mayo.-ago. 2015. tab
Artigo em Espanhol | CUMED | ID: cum-64885

RESUMO

Introducción: el virus linfotrópico de las células T humanas tipo I (HTLV-I), es el agente causal de la leucemia /linfoma de células T del adulto (LLTA). Resultados hallados en estudios de pesquisa para el HTLV-I en nuestro país demuestran sin lugar a dudas la presencia del mismo en nuestra población. El DAVIH-HTLV-I es un sistema microelisa para la detección de anticuerpos contra el HTLV-I en suero o plasma humano, producido por Laboratorios DAVIH. El objetivo de este trabajo fue evaluar el desempeño del sistema DAVIH-HTLV-I con vistas a su inscripción en el Registro de Diagnosticadores, del Centro para el Control Estatal de la Calidad de los Medicamentos (CECMED), exigencia indispensable para su uso en nuestro país. Métodos: se emplearon cuatro paneles de muestras en los estudios de: especificidad, sensibilidad, eficacia, concordancia con el sistema de referencia Vironostika HTLV-I/II (Biomeriéux), precisión a dos niveles: repetibilidad (intraensayos) y precisión intermedia (interensayos), y robustez. Resultados: la evaluación mostró los siguientes resultados: especificidad 99,84 por ciento; sensibilidad 96,49 por ciento; concordancia 96,55 por ciento, límite de detección correspondiente a una dilución de 1/256; elevada precisión intra e interensayos (CV menores que el 15 por ciento y el 20 por ciento respectivamente); sistema robusto frente a los cambios de temperatura entre 36 y 38 °C. Conclusiones: los resultados obtenidos demostraron que el sistema DAVIH-HTLV-I se puede emplear en el pesquisaje de anticuerpos contra el HTLV-I en la población cubana, por lo que se recomendó su registro en el CECMED(AU)


Introduction: Human T-cell lymphotropic virus type I (HTLV-I) is the causative agent of adult T-cell leukemia / lymphoma (LLTA). Results found in research studies for HTLV-I in our country undoubtedly demonstrate the presence of HTLV-I in our population. DAVIH-HTLV-I is a microelevel system for the detection of antibodies against HTLV-I in human serum or plasma, produced by DAVIH Laboratories. The objective of this study was to evaluate the performance of the DAVIH-HTLV-I system in order to be registered in the Diagnostic Registry of the Center for State Control of the Quality of Medicines (CECMED), an indispensable requirement for its use in our country.Methods: Four panels of samples were used in the studies: specificity, sensitivity, efficacy, concordance with the reference system Vironostika HTLV-I / II (Biomeriéux), precision on two levels: repeatability (intraassay) and intermediate precision (interassay) , And robustness.Results: the evaluation showed the following results: specificity 99.84 percent; Sensitivity 96.49 percent; Agreement 96.55 percent, limit of detection corresponding to a dilution of 1/256; High intra- and inter-assay precision (CV lower than 15 percent and 20 percent respectively); Robust system against temperature changes between 36 and 38 ° C. Conclusions: the results showed that the DAVIH-HTLV-I system can be used in the screening of antibodies against HTLV-I in the Cuban population, which is why it was recommended to register with the CECMED(AU)


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Vírus Linfotrópico T Tipo 1 Humano , /métodos , Técnicas de Laboratório Clínico/métodos
4.
Rev. cuba. med. trop ; 65(1): 46-56, ene.-abr. 2013.
Artigo em Espanhol | LILACS | ID: lil-665677

RESUMO

Introducción: la selección y el desarrollo de métodos analíticos siempre ha sido un tema importante para los laboratorios de ensayo. Para adoptar un método se hace necesario validarlo, porque el objetivo de la validación es probar la aptitud de los métodos, así como la competencia del laboratorio para realizar determinado ensayo. El sistema UMELISA HBsAg PLUS no contempla dentro de su aplicación el empleo de muestras de suero obtenidas a partir de sangre del cordón umbilical, sin embargo, con este tipo de muestra se certifica el uso de la placenta como materia prima. Objetivo: teniendo en cuenta la necesidad de demostrar que el cambio no afecta los parámetros de desempeño del sistema, se hizo su validación para muestras de suero de cordón umbilical. Métodos: se emplearon tres paneles de muestras en los estudios de especificidad, concordancia con el sistema de referencia Hepanostika HBsAg Uni-Form II, robustez, precisión a dos niveles de repetibilidad (intraensayos) y precisión intermedia (interensayos), y límite de detección. Resultados: la validación del sistema mostró los siguientes indicadores: especificidad y concordancia del 100 porciento, sistema robusto frente a los cambios de temperatura entre 35 y 38 °C, elevada precisión intraensayos (4,65 porciento) e interensayos (CV menores que 20 porciento), límite de detección correspondiente a una dilución de 1/10 000. Conclusiones: los resultados demostraron que el sistema UMELISA HBsAg PLUS se puede emplear para la detección de HBsAg en muestras de suero de cordón umbilical


Introduction: the selection and the development of analytical methods have always been an important issue for testing laboratories. The adoption of a method requires validation because the objective is to prove the capability of a method as well as the competencies of the laboratory to make an specific assay. The range of applications of UMELISA HbsAg PLUS system does not include the use of serum samples taken from the umbilical cord blood; however the use of placenta as raw material is certified with this kind of sample. Objective: to validate this system for umbilical cord serum sample taking into account the need of proving that this change does not affect the performance parameters of the system. Methods: three panels of samples were used to study specificity, agreement with the reference system Hepanostika HbsAg Uni-Form II, robustness, precision at two levels of repeatibility (intrassay) and intermediate precision (interassay) and detection limit. Results: validation of the system showed the following indicators: specificity and agreement of 100 percent, robust system against temperatures changes between 35 and 38 °C, high intraassay precision (4.65 percent) and interassays (VC less than 20 percent), detection limit corresponding to 1/10 000 dilution rate. Conclusions: obtained results showed that UMELISA HbsAg PLUS system may be used to detect HBsAg in umbilical cord serum samples


Assuntos
Humanos , Masculino , Feminino , Cordão Umbilical/citologia , Ensaio de Proficiência Laboratorial/métodos , Sangue Fetal/metabolismo , Estudos de Validação como Assunto
5.
Rev. cuba. med. trop ; 65(1)ene.-abr. 2013.
Artigo em Espanhol | CUMED | ID: cum-53230

RESUMO

Introducción: la selección y el desarrollo de métodos analíticos siempre ha sido un tema importante para los laboratorios de ensayo. Para adoptar un método se hace necesario validarlo, porque el objetivo de la validación es probar la aptitud de los métodos, así como la competencia del laboratorio para realizar determinado ensayo. El sistema UMELISA HBsAg PLUS no contempla dentro de su aplicación el empleo de muestras de suero obtenidas a partir de sangre del cordón umbilical, sin embargo, con este tipo de muestra se certifica el uso de la placenta como materia prima. Objetivo: teniendo en cuenta la necesidad de demostrar que el cambio no afecta los parámetros de desempeño del sistema, se hizo su validación para muestras de suero de cordón umbilical. Métodos: se emplearon tres paneles de muestras en los estudios de especificidad, concordancia con el sistema de referencia Hepanostika HBsAg Uni-Form II, robustez, precisión a dos niveles de repetibilidad (intraensayos) y precisión intermedia (interensayos), y límite de detección. Resultados: la validación del sistema mostró los siguientes indicadores: especificidad y concordancia del 100 porciento, sistema robusto frente a los cambios de temperatura entre 35 y 38 °C, elevada precisión intraensayos (4,65 porciento) e interensayos (CV menores que 20 porciento), límite de detección correspondiente a una dilución de 1/10 000. Conclusiones: los resultados demostraron que el sistema UMELISA HBsAg PLUS se puede emplear para la detección de HBsAg en muestras de suero de cordón umbilical(AU)


Introduction: the selection and the development of analytical methods have always been an important issue for testing laboratories. The adoption of a method requires validation because the objective is to prove the capability of a method as well as the competencies of the laboratory to make an specific assay. The range of applications of UMELISA HbsAg PLUS system does not include the use of serum samples taken from the umbilical cord blood; however the use of placenta as raw material is certified with this kind of sample. Objective: to validate this system for umbilical cord serum sample taking into account the need of proving that this change does not affect the performance parameters of the system. Methods: three panels of samples were used to study specificity, agreement with the reference system Hepanostika HbsAg Uni-Form II, robustness, precision at two levels of repeatibility (intrassay) and intermediate precision (interassay) and detection limit. Results: validation of the system showed the following indicators: specificity and agreement of 100 percent, robust system against temperatures changes between 35 and 38 °C, high intraassay precision (4.65 percent) and interassays (VC less than 20 percent), detection limit corresponding to 1/10 000 dilution rate. Conclusions: obtained results showed that UMELISA HbsAg PLUS system may be used to detect HBsAg in umbilical cord serum samples(AU)


Assuntos
Humanos , Masculino , Feminino , Cordão Umbilical/citologia , Sangue Fetal/metabolismo , Ensaio de Proficiência Laboratorial/métodos , Estudos de Validação como Assunto
6.
Rev. cuba. med. trop ; 61(2)May-Aug. 2009.
Artigo em Espanhol | LILACS | ID: lil-584920

RESUMO

INTRODUCCIÓN: en la validación de los procesos de producción de productos biológicos, la cuantificación viral es esencial para demostrar su seguridad. OBJETIVO: en este trabajo se evaluó el método de titulación del virus de la inmunodeficiencia humana tipo 1, para ello se determinó la exactitud, precisión, linealidad y límite de detección. MÉTODOS: la titulación se realizó por el método del cálculo de la dilución punto final, mediante la visualización del efecto citopático y la determinación de la producción de antígeno p24 por medio de un ensayo inmunoenzimático, la dosis infectiva media en cultivo de células por mililitro se calculó según el método de Reed y Muench. RESULTADOS: la exactitud del método coincidió con el título de referencia, los valores del coeficiente de variación de la precisión (repetibilidad y precisión intermedia) fueron menores que 5 y 10 por ciento, respectivamente; la linealidad mostró un adecuado coeficiente de correlación y el límite de detección se determinó en la dilución 10-12. CONCLUSIONES: el método evaluado demostró un adecuado desempeño para la cuantificación viral.


BACKGROUND: viral quantification is essential to demonstrate biological product safety during the validation of the production process. OBJECTIVE: to evaluate the accuracy, linearity and detection limit of a titration method for the human immunodeficiency virus type 1. METHODS: the titration was performed by calculating the end-point dilution method, through the cytopathic effect assay and the determination of Ag p24 production by an enzyme immunoassay. Mean infective dose in cultured cells per milimeter was estimated by Reed and Muench´s method. RESULTS: the accuracy of the method was similar to that of the reference titration, the variation coefficient figures for accuracy (repeatability and intermediate accuracy) were lower than 5 percent and 10 percent, respectively, the linearity showed adequate correlation coefficient and the detection limit was determined in the 10-12 dilution CONCLUSIONS: the evaluated method was suitable for viral quantification.

7.
Rev. cuba. med. trop ; 61(2)mayo-ago. 2009. graf
Artigo em Espanhol | CUMED | ID: cum-52898

RESUMO

INTRODUCCIÓN: en la validación de los procesos de producción de productos biológicos, la cuantificación viral es esencial para demostrar su seguridad. OBJETIVO: en este trabajo se evaluó el método de titulación del virus de la inmunodeficiencia humana tipo 1, para ello se determinó la exactitud, precisión, linealidad y límite de detección. MÉTODOS: la titulación se realizó por el método del cálculo de la dilución punto final, mediante la visualización del efecto citopático y la determinación de la producción de antígeno p24 por medio de un ensayo inmunoenzimático, la dosis infectiva media en cultivo de células por mililitro se calculó según el método de Reed y Muench. RESULTADOS: la exactitud del método coincidió con el título de referencia, los valores del coeficiente de variación de la precisión (repetibilidad y precisión intermedia) fueron menores que 5 y 10 por ciento, respectivamente; la linealidad mostró un adecuado coeficiente de correlación y el límite de detección se determinó en la dilución 10-12. CONCLUSIONES: el método evaluado demostró un adecuado desempeño para la cuantificación viral(AU)


BACKGROUND: viral quantification is essential to demonstrate biological product safety during the validation of the production process. OBJECTIVE: to evaluate the accuracy, linearity and detection limit of a titration method for the human immunodeficiency virus type 1. METHODS: the titration was performed by calculating the end-point dilution method, through the cytopathic effect assay and the determination of Ag p24 production by an enzyme immunoassay. Mean infective dose in cultured cells per milimeter was estimated by Reed and Muench´s method. RESULTS: the accuracy of the method was similar to that of the reference titration, the variation coefficient figures for accuracy (repeatability and intermediate accuracy) were lower than 5 percent and 10 percent, respectively, the linearity showed adequate correlation coefficient and the detection limit was determined in the 10-12 dilution CONCLUSIONS: the evaluated method was suitable for viral quantification(AU)


Assuntos
Humanos , HIV-1 , Titulometria , Estudos de Validação como Assunto
8.
Rev. cuba. med. trop ; 61(1): 20-25, ene.-abr. 2009. tab, graf
Artigo em Espanhol | LILACS | ID: lil-547069

RESUMO

Para extender el tiempo de vida útil del sistema ELISA DAVIH-AgP24, se realizó una prueba de estabilidad en anaquel. El estudio se realizó durante 12 meses, con 3 lotes consecutivos del diagnosticador. El protocolo a seguir fue ensayar la curva de calibración del control positivo, según las instrucciones de uso del sistema. Se controlaron los requisitos de calidad de cada uno de los reactivos de acuerdo con sus especificaciones. Se estudió la normalidad de los valores obtenidos en cada uno de los puntos de la curva en los meses estudiados y la homogeneidad de las medias y las varianzas utilizando como criterios de aceptación las dócimas de Grubbs y de Cochran, respectivamente. Para la precisión del ensayo, se realizó un análisis de cada uno de los puntos de la curva en los meses 1, 4, 7 y 9, mediante la utilización de cartas de control (gráficas de Levy-Jennings), estableciendo como límites ± 2 desviaciones estándar. Los requisitos de calidad de cada componente cumplieron con las especificaciones hasta el noveno mes, a partir del cual se apreciaron cambios en las características organolépticas del cromógeno tetrametilbencidina y un deterioro en las características funcionales del sistema, por causa del tampón sustrato; en el resto de los componentes no se observaron cambios. Los valores obtenidos fueron aceptados como normales hasta el noveno mes. Los valores estadísticos de Grubbs y de Cochran observados para los 6 puntos de la curva durante los 9 meses analizados fueron menores que los valores críticos tabulados para a= 5 por ciento, por lo que se concluyó que existe homogeneidad entre medias y varianzas. En los gráficos de Levey-Jennings los valores se mantuvieron dentro de los límites establecidos. Estos resultados permitieron extender el período de validez del sistema hasta 6 meses, con 50 por ciento de cobertura.


Extending useful lifetime of ELISA DAVIH-p24 Ag, an on shelf stability test was conducted. Three consecutive batches of the diagnostic kit were studied for 12 months. The applied protocol was to test the calibration curve of the positive control according to the manufacturer's instructions for the system operation. The quality requirements for each reagent, according to their specifications, were controlled. Normality in obtained values for each point of the curve in the analyzed period and also homogeneity of means and variances were studied by using Grubbs´ and Cochran´s tests, respectively. For the assay precision, each point of the curve was analyzed at 1st, 4th, 7th and 9th months by means of Levy-Jennings´ graphs, setting ± 2 standard deviations as limit values. The quality requirements of each component met the specifications up to 9th month; from that moment on, changes in the organoleptic characteristics of tetramethylbenzidine chromogen and deterioration in the operational characteristics of the system were observed due to substrate buffer. The remaining components did not change. The yielded values were accepted as normal up to the 9th month. Grubb´s and Cochran´s test values for the 6 points of the curve during the nine months were lower than the tabulated critical values for a= 5 percent, so homogeneity between means and variances was confirmed. Levey-Jennings´s graphs showed values within the set limits. These results allowed extending the validity period of the system to six months, with 50 percent coverage.


Assuntos
Humanos , Ensaio de Imunoadsorção Enzimática/métodos , Reatividade-Estabilidade
9.
Rev. cuba. med. trop ; 61(1)ene.-abr. 2009. tab, graf
Artigo em Espanhol | CUMED | ID: cum-40797

RESUMO

Para extender el tiempo de vida útil del sistema ELISA DAVIH-AgP24, se realizó una prueba de estabilidad en anaquel. El estudio se realizó durante 12 meses, con 3 lotes consecutivos del diagnosticador. El protocolo a seguir fue ensayar la curva de calibración del control positivo, según las instrucciones de uso del sistema. Se controlaron los requisitos de calidad de cada uno de los reactivos de acuerdo con sus especificaciones. Se estudió la normalidad de los valores obtenidos en cada uno de los puntos de la curva en los meses estudiados y la homogeneidad de las medias y las varianzas utilizando como criterios de aceptación las dócimas de Grubbs y de Cochran, respectivamente. Para la precisión del ensayo, se realizó un análisis de cada uno de los puntos de la curva en los meses 1, 4, 7 y 9, mediante la utilización de cartas de control (gráficas de Levy-Jennings), estableciendo como límites ± 2 desviaciones estándar. Los requisitos de calidad de cada componente cumplieron con las especificaciones hasta el noveno mes, a partir del cual se apreciaron cambios en las características organolépticas del cromógeno tetrametilbencidina y un deterioro en las características funcionales del sistema, por causa del tampón sustrato; en el resto de los componentes no se observaron cambios. Los valores obtenidos fueron aceptados como normales hasta el noveno mes. Los valores estadísticos de Grubbs y de Cochran observados para los 6 puntos de la curva durante los 9 meses analizados fueron menores que los valores críticos tabulados para a= 5 por ciento, por lo que se concluyó que existe homogeneidad entre medias y varianzas. En los gráficos de Levey-Jennings los valores se mantuvieron dentro de los límites establecidos. Estos resultados permitieron extender el período de validez del sistema hasta 6 meses, con 50 por ciento de cobertura(AU)


Extending useful lifetime of ELISA DAVIH-p24 Ag, an on shelf stability test was conducted. Three consecutive batches of the diagnostic kit were studied for 12 months. The applied protocol was to test the calibration curve of the positive control according to the manufacturer's instructions for the system operation. The quality requirements for each reagent, according to their specifications, were controlled. Normality in obtained values for each point of the curve in the analyzed period and also homogeneity of means and variances were studied by using Grubbs´ and Cochran´s tests, respectively. For the assay precision, each point of the curve was analyzed at 1st, 4th, 7th and 9th months by means of Levy-Jennings´ graphs, setting ± 2 standard deviations as limit values. The quality requirements of each component met the specifications up to 9th month; from that moment on, changes in the organoleptic characteristics of tetramethylbenzidine chromogen and deterioration in the operational characteristics of the system were observed due to substrate buffer. The remaining components did not change. The yielded values were accepted as normal up to the 9th month. Grubb´s and Cochran´s test values for the 6 points of the curve during the nine months were lower than the tabulated critical values for a= 5 percent, so homogeneity between means and variances was confirmed. Levey-Jennings´s graphs showed values within the set limits. These results allowed extending the validity period of the system to six months, with 50 percent coverage(AU)


Assuntos
Humanos , Ensaio de Imunoadsorção Enzimática/métodos , Reatividade-Estabilidade , Proteína do Núcleo p24 do HIV
10.
Rev. cuba. med. trop ; 59(3)sep.-dic. 2007. tab, graf
Artigo em Espanhol | LILACS | ID: lil-489451

RESUMO

Se expusieron los resultados del diseño y la evaluación del diagnosticador DAVIH VIH-2, sistema ELISA indirecto diseñado para el pesquisaje de anticuerpos al VIH-2, que utiliza en su fase sólida un péptido sintético de la proteína de envoltura gp36 del VIH-2. La evaluación del desempeño del sistema se realizó utilizando paneles de referencia de la OMS y se determinó que la sensibilidad fue 100 por ciento, la especificidad 99,81 por ciento, la eficacia 99,81 por ciento y la concordancia muy buena (índice kappa= 0,978). Las muestras de suero de 959 personas con resultados indeterminados o negativos a la confirmación de anticuerpos al VIH-1 (DAVIH-Blot) se evaluaron en el sistema DAVIH VIH-2. Resultaron reactivas al sistema 24 muestras, confirmßndose la presencia de anticuerpos al VIH-2 en 6 de ellas. Estos resultados permitieron sugerir la introducción de este diagnosticador en el algoritmo de diagnóstico de la infección por VIH en Cuba.


The results of the design and evaluation of DAVIH VIH-2 diagnosing system, an indirect Elisa for screening of HIV-2 antibodies, which uses a HIV-2 glycoprotein gp36 synthetic peptide in its solid phase, were exposed. In the system evaluation using WHO reference panels, 100 percent sensitivity, 99,81 percent specificity, 99,81percent efficacy and very good concordance level (kappa = 0.978) were attained. Serum samples of 959 individuals with undetermined or negative results to the HIV-1 antibodies confirmation (DAVIH blot) were evaluated by the DAVIH VIH-2 system. Twenty four samples were reactive, six of which had confirmed HIV-2 antibodies. These results allowed recommending the introduction of this diagnostic kit in the HIV infection diagnosing algorithm in Cuba.


Assuntos
Humanos , HIV-2 , Ensaio de Imunoadsorção Enzimática/métodos
11.
Rev. cuba. med. trop ; 59(3)sep.-dic. 2007. tab, graf
Artigo em Espanhol | CUMED | ID: cum-34939

RESUMO

Se expusieron los resultados del diseño y la evaluación del diagnosticador DAVIH VIH-2, sistema ELISA indirecto diseñado para el pesquisaje de anticuerpos al VIH-2, que utiliza en su fase sólida un péptido sintético de la proteína de envoltura gp36 del VIH-2. La evaluación del desempeño del sistema se realizó utilizando paneles de referencia de la OMS y se determinó que la sensibilidad fue 100 por ciento, la especificidad 99,81 por ciento, la eficacia 99,81 por ciento y la concordancia muy buena (índice kappa= 0,978). Las muestras de suero de 959 personas con resultados indeterminados o negativos a la confirmación de anticuerpos al VIH-1 (DAVIH-Blot) se evaluaron en el sistema DAVIH VIH-2. Resultaron reactivas al sistema 24 muestras, confirmándose la presencia de anticuerpos al VIH-2 en 6 de ellas. Estos resultados permitieron sugerir la introducción de este diagnosticador en el algoritmo de diagnóstico de la infección por VIH en Cuba(AU)


The results of the design and evaluation of DAVIH VIH-2 diagnosing system, an indirect Elisa for screening of HIV-2 antibodies, which uses a HIV-2 glycoprotein gp36 synthetic peptide in its solid phase, were exposed. In the system evaluation using WHO reference panels, 100 percent sensitivity, 99,81 percent specificity, 99,81percent efficacy and very good concordance level (kappa = 0.978) were attained. Serum samples of 959 individuals with undetermined or negative results to the HIV-1 antibodies confirmation (DAVIH blot) were evaluated by the DAVIH VIH-2 system. Twenty four samples were reactive, six of which had confirmed HIV-2 antibodies. These results allowed recommending the introduction of this diagnostic kit in the HIV infection diagnosing algorithm in Cuba


Assuntos
Humanos , HIV-2 , Ensaio de Imunoadsorção Enzimática/métodos
12.
Rev Cubana Med Trop ; 59(3): 241-6, 2007.
Artigo em Espanhol | MEDLINE | ID: mdl-23427463

RESUMO

The results of the design and evaluation of DAVIH VIH-2 diagnosing system, an indirect Elisa for screening of HIV-2 antibodies, which uses a HIV-2 glycoprotein gp36 synthetic peptide in its solid phase, were exposed. In the system evaluation using WHO reference panels, 100% sensitivity, 99,81% specificity, 99,81% efficacy and very good concordance level (kappa = 0.978) were attained. Serum samples of 959 individuals with undetermined or negative results to the HIV-1 antibodies confirmation (DAVIH blot) were evaluated by the DAVIH VIH-2 system. Twenty four samples were reactive, six of which had confirmed HIV-2 antibodies. These results allowed recommending the introduction of this diagnostic kit in the HIV infection diagnosing algorithm in Cuba.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Anticorpos Anti-HIV/sangue , Infecções por HIV/virologia , HIV-2/imunologia , Especificidade de Anticorpos , Relação Dose-Resposta Imunológica , Antígenos HIV/imunologia , Infecções por HIV/sangue , Infecções por HIV/diagnóstico , Soronegatividade para HIV , Soropositividade para HIV/sangue , HIV-1/imunologia , Humanos , Fragmentos de Peptídeos/síntese química , Fragmentos de Peptídeos/imunologia , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura , Fatores de Tempo
13.
Rev. cuba. hematol. inmunol. hemoter ; 13(2): 109-15, jul.-dic. 1997. ilus
Artigo em Espanhol | LILACS | ID: lil-221038

RESUMO

Las glicoproteínas de 41 KD y 120 KD de la envoltura del virus de inmunodeficiencia humana tipo I (VIH-1) se emplean ampliamente en el desarrollo de medios diagnósticos, y con este fin se purificaron a partir de células infectadas tratadas con desoxicolato de sodio al 1 porciento, por cromatografía de afinidad sobre lentil-lectina Sefarosa 4B. El procedimiento resultó eficiente y sencillo. Durante este proceso se recuperaron 3,375 mg y las proteínas purificadas no perdieron, en el proceso de purificación, sus propiedades inmunogénicas y antigénicas, al reaccionar frente a un suero positivo al VIH-1 y frente a anticuerpos monoclonales. Los antisueros obtenidos de estas glicoproteínas en ratones alcanzaron títulos de trabajo de hasta 1:32 000 por ELISA. Los pesos moleculares determinados por tinción con nitrato de plata, mostraron valores muy cercanos a los reportados


Assuntos
HIV/isolamento & purificação , /isolamento & purificação , Cromatografia de Afinidade
14.
Rev. cuba. hematol. inmunol. hemoter ; 13(2): 109-15, jul.-dic. 1997. ilus
Artigo em Espanhol | CUMED | ID: cum-12704

RESUMO

Las glicoproteínas de 41 KD y 120 KD de la envoltura del virus de inmunodeficiencia humana tipo I (VIH-1) se emplean ampliamente en el desarrollo de medios diagnósticos, y con este fin se purificaron a partir de células infectadas tratadas con desoxicolato de sodio al 1 porciento, por cromatografía de afinidad sobre lentil-lectina Sefarosa 4B. El procedimiento resultó eficiente y sencillo. Durante este proceso se recuperaron 3,375 mg y las proteínas purificadas no perdieron, en el proceso de purificación, sus propiedades inmunogénicas y antigénicas, al reaccionar frente a un suero positivo al VIH-1 y frente a anticuerpos monoclonales. Los antisueros obtenidos de estas glicoproteínas en ratones alcanzaron títulos de trabajo de hasta 1:32 000 por ELISA. Los pesos moleculares determinados por tinción con nitrato de plata, mostraron valores muy cercanos a los reportados (AU)


Assuntos
Proteína gp120 do Envelope de HIV/isolamento & purificação , HIV/isolamento & purificação , Cromatografia de Afinidade
15.
Rev. cuba. med. trop ; 49(1): 24-7, 1997. tab
Artigo em Espanhol | LILACS | ID: lil-208296

RESUMO

Se estudió la presencia de anticuerpos contra el virus linfotrópico de células T humanas tipo I (HTLV I) en 3 774 sueros; de ellos, 1 409 eran donantes de sangre, 1 444 de pacientes que habían padecido recientemente alguna enfermedad de transmisión sexual (ETS) y 921 de enfermos politransfundidos. Se emplearon los sistemas DAVIH HTLV I (ELISA) y DAVIH BLOT HTLV 1 (Western Blot) producidos en Laboratorios DAVIH (La Habana, Cuba), para el pesquisaje y confirmación, respectivamente. De los 68 sueros reactivos en la prueba de ELISA, en 2 se confirmó la presencia de anticuerpos al HTLV I/II y 12 fueron considerados indeterminados por el Western Blot


Assuntos
Humanos , Doadores de Sangue , Western Blotting , Anticorpos Antideltaretrovirus/sangue , Ensaio de Imunoadsorção Enzimática , Grupos de Risco
16.
Rev. cuba. med. trop ; 49(1): 24-7, 1997. tab
Artigo em Espanhol | CUMED | ID: cum-11576

RESUMO

Se estudió la presencia de anticuerpos contra el virus linfotrópico de células T humanas tipo I (HTLV I) en 3 774 sueros; de ellos, 1 409 eran donantes de sangre, 1 444 de pacientes que habían padecido recientemente alguna enfermedad de transmisión sexual (ETS) y 921 de enfermos politransfundidos. Se emplearon los sistemas DAVIH HTLV I (ELISA) y DAVIH BLOT HTLV 1 (Western Blot) producidos en Laboratorios DAVIH (La Habana, Cuba), para el pesquisaje y confirmación, respectivamente. De los 68 sueros reactivos en la prueba de ELISA, en 2 se confirmó la presencia de anticuerpos al HTLV I/II y 12 fueron considerados indeterminados por el Western Blot(AU)


Assuntos
Humanos , Anticorpos Antideltaretrovirus/sangue , Doadores de Sangue , Grupos de Risco , Ensaio de Imunoadsorção Enzimática , Western Blotting
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...