NMR Biomed ; 25(9): 1026-32, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22275333

RESUMO

The apparent diffusion coefficient (ADC) of hyperpolarized (HP) gases is a parameter that reflects changes in lung microstructure. However, ADC is dependent on many physiological and experimental variables that need to be controlled or specified in order to ensure the reliability and reproducibility of this parameter. A single breath-hold experiment is desirable in order to reduce the amount of consumed HP gas. The application of a positive end-expiratory pressure (PEEP) causes an increase in the residual gas volume. Depending on the applied PEEP, the ratio between the incoming and residual gas volumes will change and the ADC will vary, as long as both gases do not have the same diffusion coefficient. The most standard method for human applications uses air for breathing and a bolus of pure HP (3)He for MRI data acquisition. By applying this method in rats, we have demonstrated that ADC values are strongly dependent on the applied PEEP, and therefore on the residual gas volume in the lung. This outcome will play an important role in studies concerning certain diseases, such as emphysema, which is characterized by an increase in the residual volume. Ventilation with an oxygen-helium mixture (VOHeM) is a proposed single breath-hold method that uses two different gas mixtures (O(2)-(4)He for ventilation and HP (3)He-N(2) for imaging). The concentration of each gas in its respective mixture was calculated in order to obtain the same diffusion coefficient in both mixtures. ADCs obtained from VOHeM are independent of PEEP, thus minimizing the effect of the different residual volumes.


Assuntos
Hélio , Pulmão/fisiologia , Animais , Difusão , Humanos , Masculino , Respiração com Pressão Positiva , Ventilação Pulmonar/fisiologia , Ratos , Ratos Wistar , Padrões de Referência , Reprodutibilidade dos Testes
2.
IEEE Trans Biomed Eng ; 59(3): 777-86, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22167560

RESUMO

Pulmonary diseases are known to be largely inhomogeneous. To evaluate such inhomogeneities, we are testing an image-based method to measure gas flow in the lung regionally. Dynamic, spin-density-weighted hyperpolarized (3)He MR images performed during slow inhalation of this gas were analyzed to quantify regional inflation rate. This parameter was measured in regions of interest (ROIs) that were defined by a rectangular grid that covered the entire rat lung and grew dynamically with it during its inflation. We used regional inflation rate to quantify elastase-induced emphysema and to differentiate healthy (n = 8) from elastase-treated (n = 9) rat lungs as well as healthy from elastase-treated areas of one rat unilaterally treated with elastase in the left lung. Emphysema was also assessed by gold standard morphological and well-established hyperpolarized (3)He MRI diffusion measurements. Mean values of regional inflation rates were significantly different for healthy and elastase-treated animals and correlated well with the apparent diffusion coefficient of (3)He and morphological measurements. The image-based biomarker inflation rate may be useful for the assessment of regional lung ventilation.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Hélio , Enfisema Pulmonar/diagnóstico , Animais , Modelos Animais de Doenças , Feminino , Isótopos , Elastase Pancreática , Enfisema Pulmonar/patologia , Ratos , Ratos Wistar , Sensibilidade e Especificidade