Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
3.
Curr Eye Res ; 47(1): 143-153, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34213409

RESUMO

PURPOSE: To evaluate the inner retinal layers in fibromyalgia (FM) patients compared to control subjects using posterior pole protocol (PPole) analysis in optical coherence tomography (OCT) and to correlate structural retinal changes with subjective quality of life. METHODS: Seventy-four eyes of healthy subjects and 55 eyes of those with FM were analyzed. All subjects underwent retinal evaluation using the PPole protocol for Spectralis OCT (Heidelberg Engineering) to obtain measurements of the retinal nerve fiber layer (RNFL) and the ganglion cell layer (GCL) in the macular area. The EuroQol (EQ-5D) questionnaire and Fibromyalgia Impact Questionnaire (FIQ) were performed to analyze health-related quality of life. Additionally, the FM group was divided into three groups depending on the disease phenotype (atypical, depressive, and biological). RESULTS: Patients with FM presented with a reduction of the RNFL thickness compared to controls in 17/64 cells of the PPole area, and a reduction of the GCL thickness in 47/64 cells. Depressive FM phenotype showed the greatest number of cells with significant reduction compared with the control group in both RNFL and GCL layers. A correlation between temporal-inferior cells of the GCL and the EuroQol 5D questionnaire results was observed. CONCLUSIONS: Patients with FM present with a reduction of the inner retinal layers in the macular area. This degeneration correlates with disease severity/reduced quality of life in these patients. The PPole protocol for OCT is a non-invasive and fast tool that might help clinicians diagnose and monitor neurodegeneration in FM patients.


Assuntos
Protocolos Clínicos , Fibromialgia/diagnóstico , Macula Lutea/patologia , Qualidade de Vida , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Feminino , Fibromialgia/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Índice de Gravidade de Doença , Inquéritos e Questionários
4.
Arch. Soc. Esp. Oftalmol ; 96(4): 210-213, abr. 2021. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-217604

RESUMO

La fotografía de fibras clásica, usada tradicionalmente para identificar defectos en la capa de fibras nerviosas de la retina (CFNR), tiene un uso limitado debido a la necesidad de un equipo fotográfico específico y un técnico experto en la adquisición de esta clase de imágenes. El nuevo módulo MultiColor de la tomografía de coherencia óptica (OCT) SPECTRALIS®, utilizando 3 longitudes de onda diferentes simultáneamente, es capaz de proporcionar imágenes en las que se identifican las estructuras de la retina en diferente color según su profundidad. Nos propusimos realizar un pequeño estudio de concordancia para determinar la utilidad del nuevo software MultiColor frente a la fotografía de fibras tradicional en la identificación de defectos en la CFNR. La concordancia interobservador en la interpretación de imágenes MultiColor fue buena (κ=0,746; p<0,001); y se consiguieron identificar con MultiColor en torno al 70% de pacientes con glaucoma leve. Consideramos que el nuevo software MultiColor resulta útil en la evaluación de defectos de la CFNR, y es sencillo de realizar (AU)


The classical fibre photography traditionally used to identify defects in the retinal nerve fibre layer (RNFL), has been partially discontinued due to poor availability. The new MultiColour module of SPECTRALIS® Optical Coherence Tomography (OCT), using three different laser wavelengths simultaneously, can provide images that identify the structures of the retina in different colours according to their depth. A small concordance study was conducted to determine the usefulness of the new MultiColour software versus traditional fibre photography in identifying RNFL defects. The inter-observer agreement in the interpretation of MultiColour images was good (κ=.746; P<.001), as by using Multicolour they were able to identify around 70% of patients with mild glaucoma. It is believed that the new Multicolour software is useful in evaluating RNFL defects, and is easy to perform (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Retina/diagnóstico por imagem , Fibras Ópticas , Software , Glaucoma/diagnóstico por imagem , Tomografia de Coerência Óptica , Variações Dependentes do Observador
5.
Arch Soc Esp Oftalmol (Engl Ed) ; 96(4): 210-213, 2021 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32888744

RESUMO

The classical fibre photography traditionally used to identify defects in the retinal nerve fibre layer (RNFL), has been partially discontinued due to poor availability. The new MultiColour module of SPECTRALIS® Optical Coherence Tomography (OCT), using three different laser wavelengths simultaneously, can provide images that identify the structures of the retina in different colours according to their depth. A small concordance study was conducted to determine the usefulness of the new MultiColour software versus traditional fibre photography in identifying RNFL defects. The inter-observer agreement in the interpretation of MultiColour images was good (κ=.746; P<.001), as by using Multicolour they were able to identify around 70% of patients with mild glaucoma. It is believed that the new Multicolour software is useful in evaluating RNFL defects, and is easy to perform.

6.
J Fr Ophtalmol ; 43(2): 111-122, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31862121

RESUMO

PURPOSE: To map retinal sensitivity and peripapillary retinal nerve fiber layer (RNFL) thickness, as measured by standard automated perimetry (SAP) and optical coherence tomography (OCT) respectively, in patients with various stages of primary open-angle glaucoma (POAG). METHODS: Ninety patients with POAG were prospectively selected for SAP and for OCT RNFL thickness measurements. Factorial analysis performed independently for each hemifield was used to identify groups of related SAP visual field points. Pearson correlation coefficients were determined between visual field regions and peripapillary RNFL sectors and these data used to construct structure-function correlation maps for the various disease stages. RESULTS: Factorial analysis identified 4 factors or visual field regions for the inferior hemifield and 5 for the superior hemifield. For all patients and the subset of patients with advanced POAG, the strongest correlation was detected between the superior hemifield and the inferior RNFL sectors, while higher correlations for incipient and moderate disease stages were observed between the inferior hemifield and the superior RNFL sectors. CONCLUSIONS: In these patients, functional and structural damage can be mapped such that each zone of related SAP points correlates with one or several peripapillary RNFL zones. Such maps could improve our understanding of structure-function relationships in glaucoma.


Assuntos
Glaucoma/patologia , Glaucoma/fisiopatologia , Células Ganglionares da Retina/patologia , Células Ganglionares da Retina/fisiologia , Campos Visuais/fisiologia , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Feminino , Glaucoma/diagnóstico , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/patologia , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Fibras Nervosas/fisiologia , Tamanho do Órgão , Estudos Prospectivos , Relação Estrutura-Atividade , Tomografia de Coerência Óptica , Testes de Campo Visual/métodos
7.
PLoS One ; 14(11): e0224500, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31703082

RESUMO

PURPOSE: To determine if a novel analysis method will increase the diagnostic value of the multifocal electroretinogram (mfERG) in diagnosing early-stage multiple sclerosis (MS). METHODS: We studied the mfERG signals of OD (Oculus Dexter) eyes of fifteen patients diagnosed with early-stage MS (in all cases < 12 months) and without a history of optic neuritis (ON) (F:M = 11:4), and those of six controls (F:M = 3:3). We obtained values of amplitude and latency of N1 and P1 waves, and a method to assess normalized root-mean-square error (FNRMSE) between model signals and mfERG recordings was used. Responses of each eye were analysed at a global level, and by rings, quadrants and hemispheres. AUC (area under the ROC curve) is used as discriminant factor. RESULTS: The standard method of analysis obtains further discrimination between controls and MS in ring R3 (AUC = 0.82), analysing N1 waves amplitudes. In all of the retina analysis regions, FNRMSE value shows a greater discriminating power than the standard method. The highest AUC value (AUC = 0.91) was in the superior temporal quadrant. CONCLUSION: By analysing mfERG recordings and contrasting them with those of healthy controls it is possible to detect early-stage MS in patients without a previous history of ON.


Assuntos
Eletrorretinografia , Esclerose Múltipla/diagnóstico , Processamento de Sinais Assistido por Computador , Adulto , Área Sob a Curva , Feminino , Humanos , Masculino , Esclerose Múltipla/fisiopatologia , Curva ROC , Campos Visuais/fisiologia
8.
J Ophthalmol ; 2019: 2890193, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31641531

RESUMO

OBJECTIVES: To assess the capability of the vision monitor unit Monpack One of detecting visual function alterations in patients with multiple sclerosis (MS) and to evaluate the correlation between structural retinal parameters and functional measurements obtained with this device. METHODS: Forty-eight patients with MS and 46 healthy controls were included in a cross-sectional study. All participants underwent a complete functional evaluation of the visual pathway, which included low-contrast visual acuity (LCVA), contrast sensitivity vision (CSV), automated perimetry, multifocal visual evoked potentials (mfVEPs), and pattern electroretinogram (ERG). All tests were performed using the vision monitor unit Monpack One (Metrovision, France), a multifunction stimulator device. Retinal structural measurements were obtained in all subjects using Triton swept source optical coherence tomography (Topcon, Japan). RESULTS: Patients with MS presented reduced low-contrast VA (p < 0.001) and reduced CSV at medium (p=0.001, p=0.013) and low (p=0.001, p=0.002) spatial frequencies. All visual field parameters were found to be altered in MS patients compared with controls (≤0.001). Patients with MS presented lower amplitude of the P100 waveform of the mfVEP in areas corresponding to central (p < 0.001), inferonasal (p=0.001), and inferotemporal (p=0.003) retina. The pattern ERG did not show significant differences. Significant correlations were observed between structural retinal measurements and functional parameters, especially between the inner macular areas and measurements corresponding to contrast sensitivity and perimetry indexes. CONCLUSIONS: Patients with MS present visual dysfunction detectable with the vision monitor unit Monpack One. This device may be a fast and useful tool to provide a full evaluation of axonal damage in patients with multiple sclerosis.

9.
Indian J Ophthalmol ; 67(10): 1765-1768, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31546559

RESUMO

We present the case of a 52-year-old woman referred to our service because of extreme ocular surface dryness. The patient showed corneal, conjunctival, and eyelid manifestations of ocular congenital erythropoietic porphyria (CEP). We started treatment with autologous serum, topical steroids, and cyclosporine twice a day, topical retinoids, and intense corneal lubrication. The patient referred significant improvement of ocular bothering and less discomfort since treatment was initiated. We describe the management of the herewith presented case of ocular CEP.


Assuntos
Túnica Conjuntiva/patologia , Doenças da Túnica Conjuntiva/etiologia , Córnea/patologia , Doenças da Córnea/etiologia , Disfunção da Glândula Tarsal/etiologia , Glândulas Tarsais/patologia , Porfiria Eritropoética/complicações , Doenças da Túnica Conjuntiva/diagnóstico , Doenças da Córnea/diagnóstico , Feminino , Humanos , Disfunção da Glândula Tarsal/diagnóstico , Pessoa de Meia-Idade , Porfiria Eritropoética/diagnóstico , Microscopia com Lâmpada de Fenda
10.
Arch Soc Esp Oftalmol (Engl Ed) ; 94(1): 18-24, 2019 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30270036

RESUMO

PURPOSE: To assess structural changes in the retina using optical coherence tomography (OCT) in children prenatally exposed to toxic substances. METHODS: The study included a total of 49 infants, aged between 5 and 18years, exposed to toxic substances during pregnancy. Among the exposed children, 25 were exposed to tobacco, 20 were exposed to alcohol, and 4 children were exposed to other drugs of abuse. All children underwent a complete ophthalmology examination, including an OCT. The results were compared against a control group composed of 25 infants, age matched with controlled pregnancy, and not exposed to toxic substances. RESULTS: Children prenatally exposed to toxic substances showed significantly thinner average retinal nerve fibre layer (RNFL) compared with control children (81.5 vs. 99.7µm; P<.005), as well as RNFL thinning in its four quadrants (superior RNFL: 97.5 vs. 127.5µm; P<.005; nasal RNFL: 61.5 vs. 72.3µm; P<.005; inferior RNFL: 99.8 vs. 128.6µm; P<.005, temporal RNFL: 58.3 vs. 68.2µm; P<.005). Exposed children also exhibited a thinner ganglion cell layer (72.9 vs. 85.9; P<.005). Greater RNFL thinning was observed in children exposed to drugs of abuse (RNFL thinner average=72), followed by children exposed to alcohol (RNFL thinner average=72.9), and finally the least affected were those children exposed to tobacco during pregnancy (RNFL=94.6). CONCLUSION: Toxic substances during pregnancy interfere in retinal development. These results strengthen the evidence about the avoidance of any toxic substance during pregnancy.


Assuntos
Depressores do Sistema Nervoso Central , Etanol , Drogas Ilícitas , Nicotiana , Efeitos Tardios da Exposição Pré-Natal , Retina/crescimento & desenvolvimento , Adolescente , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Masculino , Análise por Pareamento , Tamanho do Órgão , Gravidez , Análise de Regressão , Retina/efeitos dos fármacos , Retina/patologia , Tomografia de Coerência Óptica , Acuidade Visual
11.
J Fr Ophtalmol ; 41(8): 725-732, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30197189

RESUMO

PURPOSE: To determine the relationship between macular thickness and peripapillary retinal nerve fiber layer (RNFLp) thickness in different stages of primary open-angle glaucoma (POAG). METHODS: Ninety prospectively selected patients with different stage POAG underwent spectral domain optical coherence tomography (SD-OCT) to determine macular and RNFLp thicknesses in different regions and sectors respectively. Correlations were then established through Pearson's correlation coefficient between RNFLp and macular thicknesses in the different disease stages. RESULTS: Greatest correlation was observed between the inferior RNFLp sector and the internal inferior macula both in the whole patient population and in the subset of patients with incipient glaucoma. CONCLUSIONS: When the optic nerve disc is affected by another condition, macular thickness determination may help detect POAG and monitor its progression.


Assuntos
Glaucoma de Ângulo Aberto/patologia , Macula Lutea/patologia , Nervo Óptico/patologia , Neurônios Retinianos/patologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Progressão da Doença , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Macula Lutea/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Nervo Óptico/diagnóstico por imagem , Tamanho do Órgão , Células Ganglionares da Retina/patologia , Índice de Gravidade de Doença , Tomografia de Coerência Óptica
12.
Arch Soc Esp Oftalmol (Engl Ed) ; 93(5): 231-238, 2018 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29454631

RESUMO

Parkinson's disease (PD) is a neurodegenerative process that affects 7.5 million people around the world. Since 2004, several studies have demonstrated changes in various retinal layers in PD using optical coherence tomography (OCT). However, there are some discrepancies in the results of those studies. Some of them have correlated retinal thickness with the severity or duration of the disease, demonstrating that OCT measurements may be an innocuous and easy biomarker for PD progression. Other studies have demonstrated visual dysfunctions since early phases of the disease. Lastly, the most recent studies that use Swept Source OCT technology, have found choroidal thickness increase in PD patients and provide new information related to the retinal degenerative process in this disease. The aim of this paper is to review the literature on OCT and PD, in order to determine the altered retinal and choroidal parameters in PD and their possible clinical usefulness, and also the visual dysfunctions with higher impact in these patients.


Assuntos
Corioide/patologia , Doença de Parkinson/complicações , Doença de Parkinson/fisiopatologia , Retina/patologia , Visão Ocular/fisiologia , Corioide/diagnóstico por imagem , Humanos , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica
13.
Eye (Lond) ; 31(7): 1034-1041, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28282060

RESUMO

AimTo evaluate visual dysfunction and its correlation with structural changes in the retina in patients with Alzheimer's disease (AD).MethodsPatients with AD (n=24) and controls (n=24) underwent evaluation of visual acuity (VA), color vision (using the Farnsworth and L'Anthony desaturated (D) 15 color tests), and contrast sensitivity vision (CSV; using the Pelli-Robson chart and CSV-1000E test) to measure visual dysfunction. Structural measurements of the retinal nerve fiber layer (RNFL) and macular thickness were obtained using spectral domain-optical coherence tomography (SD-OCT).ResultsCSV at three of the four spatial frequencies was significantly worse in AD patients than in controls. Color vision was significantly affected in AD patients based on the Farnsworth color test. Compared with controls, macular thinning was detected in all sectors except the fovea, and the RNFL exhibited significant thinning in the superior quadrant and lower average thickness (P<0.05). CSV was the functional parameter most strongly correlated with structural measurements in patients with AD. Color vision was strongly associated with macular volume (r>0.70, P<0.05). VA at different levels of contrast was associated with macular and RNFL thickness.ConclusionsPatients with AD had visual dysfunction that correlated with structural changes evaluated by SD-OCT. Macular measurements may be reliable indicators of visual impairment in AD patients.


Assuntos
Doença de Alzheimer/complicações , Visão de Cores/fisiologia , Sensibilidades de Contraste/fisiologia , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Transtornos da Visão/etiologia , Acuidade Visual , Idoso , Feminino , Humanos , Masculino , Transtornos da Visão/diagnóstico , Transtornos da Visão/fisiopatologia , Testes Visuais
14.
BMJ Open ; 6(5): e009658, 2016 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-27154474

RESUMO

OBJECTIVES: To evaluate visual dysfunction and its correlation with structural changes in the retina in patients with Parkinson's disease (PD). METHODS: Patients with PD (n=37) and controls (n=37) were included in an observational cross-sectional study, and underwent visual acuity (VA), colour vision (using the Farnsworth and Lanthony desaturated D15 colour tests) and contrast sensitivity vision (CSV; using the Pelli-Robson chart and CSV 1000E test) evaluation to measure visual dysfunction. Structural measurements of the retinal nerve fibre layer (RNFL), and macular and ganglion cell layer (GCL) thicknesses, were obtained using spectral domain optical coherence tomography (SD-OCT). Comparison of obtained data, and correlation analysis between functional and structural results were performed. RESULTS: VA (in all different contrast levels) and all CSV spatial frequencies were significantly worse in patients with PD than in controls. Colour vision was significantly affected based on the Lanthony colour test. Significant GCL loss was observed in the minimum GCL+inner plexiform layer. A clear tendency towards a reduction in several macular sectors (central, outer inferior, outer temporal and superior (inner and outer)) and in the temporal quadrant of the RNFL thickness was observed, although the difference was not significant. CSV was the functional parameter most strongly correlated with structural measurements in PD. Colour vision was associated with most GCL measurements. Macular thickness was strongly correlated with macular volume and functional parameters (r>0.70, p<0.05). CONCLUSIONS: Patients with PD had visual dysfunction that correlated with structural changes evaluated by SD-OCT. GCL measurements may be reliable indicators of visual impairment in patients with PD.


Assuntos
Fibras Nervosas/patologia , Doença de Parkinson/fisiopatologia , Retina/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica , Transtornos da Visão/patologia , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/complicações , Doença de Parkinson/epidemiologia , Retina/diagnóstico por imagem , Retina/fisiopatologia , Fatores de Risco , Espanha/epidemiologia , Transtornos da Visão/diagnóstico por imagem , Acuidade Visual
15.
Arch Soc Esp Oftalmol ; 91(3): 108-13, 2016 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-26743186

RESUMO

OBJECTIVE: To evaluate the anesthetic block provided by contact topical anesthesia (CTA) in strabismus surgery in adult patients. To analyze postoperative pain and surgical outcome obtained by CTA compared with general anesthesia (GA). METHODOLOGY: Prospective longitudinal cohort study of adult patients undergoing strabismus surgery by CTA or GA. The intensity of pain perceived by patients during the course of surgery and in the postoperative period was measured using Numerical Pain Scale. The success of the surgical outcome, considered as a residual ocular deviation<10 prism diopters, was evaluated. RESULTS: Twenty-three patients were operated using CTA and 26 using AG. During the course of surgery, pain intensity experienced by patients in ATC group was 3.17±2.44. There were no differences between CTA group and AG group in the intensity of pain in the immediate postoperative period (2.13±2.39 vs. 2.77±2.18, respectively; P=.510) and during the first postoperative day (3.22±2.84 vs. 3.17±2.73; P=.923). Surgical success was significantly higher in the CTA group than in the GA group (78.3 vs. 73.1%; P=.019). CONCLUSIONS: CTA provides adequate sensory block to perform strabismus surgery. The control of postoperative pain is similar to that obtained with AG. Conservation of ocular motility providing CTA enables better surgical outcome.


Assuntos
Anestesia Geral , Anestesia Local , Dor Pós-Operatória , Estrabismo/cirurgia , Adulto , Anestésicos Locais , Humanos , Estudos Prospectivos
16.
J Fr Ophtalmol ; 38(7): 580-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25976129

RESUMO

PURPOSE: We measured the amount of hemoglobin at the optic nerve head of fibromyalgia (FM) patients using new colorimetric analysis software. We also investigated whether perfusion defects of the optic nerve head in patients with FM lead to tissue atrophy and corresponding retinal nerve fiber layer (RNFL) thinning measured by optical coherence tomography (OCT). METHODS: We recruited for this cross-sectional study 118 FM patients and 76 sex- and age-matched healthy controls. All subjects underwent a complete neuro-ophthalmologic examination, which also included visual field testing using the Spark strategy in an Easyfield perimeter, and OCT examinations using the Spectralis. One photograph of the optic disc was obtained using a Cirrus™ Photo 800 multi-modality imager. We analyzed fundus photographs using Laguna ONhE software, a new method that allows hemoglobin levels to be measured at the optic nerve head. We compared hemoglobin percentages in different sectors of the nerve head and RNFL thicknesses between the two groups. RESULTS: Mean hemoglobin percentages and hemoglobin content in all optic nerve head sectors calculated by the Laguna ONhE program were significantly lower in FM patients than in healthy controls, and the main differences were detected in the outer ring, which corresponds with the neuroretinal rim. However, only the differences in the superotemporal RNFL were statistically significant. Correlations between the RNFL thickness and the percentage of hemoglobin in the different sectors were weak. CONCLUSION: Optic disc perfusion was decreased in patients with FM, especially within the neuroretinal rim, without clear involvement in the RNFL.


Assuntos
Colorimetria/métodos , Fibromialgia/fisiopatologia , Hemoglobinometria/métodos , Processamento de Imagem Assistida por Computador/métodos , Atrofia Óptica/diagnóstico , Disco Óptico/irrigação sanguínea , Neuropatia Óptica Isquêmica/diagnóstico , Software , Adulto , Circulação Sanguínea , Estudos de Casos e Controles , Feminino , Fibromialgia/complicações , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Atrofia Óptica/etiologia , Atrofia Óptica/fisiopatologia , Disco Óptico/patologia , Neuropatia Óptica Isquêmica/etiologia , Neuropatia Óptica Isquêmica/fisiopatologia , Fotografação , Fumar/fisiopatologia , Tomografia de Coerência Óptica
18.
Arch Soc Esp Oftalmol ; 90(3): 119-38, 2015 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-25459683

RESUMO

OBJECTIVE: To present a clinical practice guideline update on the medical, laser, and surgical treatment of primary angle closure glaucoma (PACG) in adults. METHODS: Following the formulation of key questions using the PICO scheme (Patient/Problem, Intervention, Comparison, Outcome), a systematic review was performed on the literature published to date, including international clinical practice guidelines. The AMSTAR and Risk of Bias tools were used for evaluating the quality of the information. The level of evidence and grade of recommendation was established following the Scottish Intercollegiate Guidelines Network (SIGN) system. RESULTS: Following the above methodology, recommendations of medical, laser and surgical treatment in adult PACG and levels of evidence are presented. CONCLUSIONS: Although the level of scientific evidence for many of the questions raised is not very high, a review is presented on updated treatment recommendations for adult PACG. Among the limitations for the implementation of these recommendations is that most studies have been conducted in Asian populations, and that the effectiveness is measured almost exclusively in terms of reducing intraocular pressure, and does not include visual function, quality of life or cost-effectiveness parameters.


Assuntos
Glaucoma de Ângulo Fechado/terapia , Guias de Prática Clínica como Assunto , Antagonistas Adrenérgicos beta/uso terapêutico , Adulto , Idoso , Anti-Hipertensivos/uso terapêutico , Doença Crônica , Terapia Combinada , Quimioterapia Combinada , Medicina Baseada em Evidências , Glaucoma de Ângulo Fechado/tratamento farmacológico , Glaucoma de Ângulo Fechado/cirurgia , Humanos , Pressão Intraocular/efeitos dos fármacos , Terapia a Laser , Fotocoagulação , Metanálise como Assunto , Pessoa de Meia-Idade , Prostaglandinas F Sintéticas/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Tonometria Ocular , Adulto Jovem
19.
Eye (Lond) ; 28(6): 680-90, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24625377

RESUMO

BACKGROUND: To evaluate and compare the ability of two Fourier-domain optical coherence tomography (OCT) devices to detect retinal and retinal nerve fibre layer (RNFL) atrophy in patients with Alzheimer's disease (AD) compared with healthy subjects; to test the intra-session reliability of two OCT devices in AD patients and healthy subjects. METHODS: AD patients (n=75) and age-matched healthy subjects (n=75) underwent three Macular Cube 200 × 200 protocols using the Cirrus and Spectralis OCT devices and three 360° circular scans centred on the optic disc using the Cirrus OCT device, the classic glaucoma application, and the new Nsite Axonal Analytics application of the Spectralis OCT instrument. Differences between healthy and AD eyes were compared, and measurements provided by each OCT protocol were compared. Reliability was measured using intraclass correlation coefficients and coefficients of variation. Correlations between OCT measurements and disease duration and severity were also analysed. RESULTS: Retinal thinning was observed in AD eyes in all areas except the fovea using both OCT devices. RNFL atrophy was detected in AD eyes with all three protocols, but the Nsite Axonal application was the most sensitive. Measurements by the two OCT devices were correlated, but differed significantly. Reliability was good using all protocols, but better with the glaucoma application of Spectralis. Mean RNFL thickness provided by the Nsite Axonal application correlated with disease duration. CONCLUSIONS: Fourier-domain OCT is a valid and reliable technique for detecting subclinical RNFL and retinal atrophy in AD, especially using the Nsite Axonal application. RNFL thickness decreased with disease duration.


Assuntos
Doença de Alzheimer/diagnóstico , Técnicas de Diagnóstico Oftalmológico/instrumentação , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/instrumentação , Idoso , Idoso de 80 Anos ou mais , Atrofia , Feminino , Análise de Fourier , Humanos , Masculino , Reprodutibilidade dos Testes , Transtornos da Visão/diagnóstico , Campos Visuais
20.
Br J Ophthalmol ; 98(3): 350-5, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24276697

RESUMO

AIMS: To determine whether there is an association between retinal thinning and functional rating scales in patients with Parkinson's disease (PD). MATERIALS AND METHODS: Patients with PD (n=153) and controls (n=242) underwent evaluations of the macula and retinal nerve fibre layer (RNFL) using two new-generation Fourier domain optical coherence tomography (OCT) devices (Cirrus, Carl Zeiss Meditec, Dublin, California, USA; Spectralis, Heidelberg Engineering, Heidelberg, Germany). PD severity was assessed using the Schwab-England Activities of Daily Living scale, the Unified Parkinson Disease Rating Scale, the Hoehn and Yahr (HY) scale. Retinal and RNFL thicknesses were compared between patients and controls. Correlations between structural parameters and the scores of the neurologic scales were evaluated. RESULTS: RNFL parameters were significantly reduced in patients with PD, especially when using the Spectralis OCT device. All macular parameters, except for foveal thickness, differed significantly between controls and patients with PD (p<0.001). HY scores were significantly and inversely correlated with all macular parameters when measured with the Spectralis OCT device (p<0.05) and with RNFL thickness when measured with the Cirrus OCT device (nasal quadrant, sectors 2 and 5). CONCLUSIONS: The neurodegeneration caused by PD can be detected using Fourier domain OCT. RNFL and macular thicknesses correlate with PD severity.


Assuntos
Fibras Nervosas/patologia , Doença de Parkinson/fisiopatologia , Degeneração Retiniana/fisiopatologia , Células Ganglionares da Retina/patologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/diagnóstico , Degeneração Retiniana/diagnóstico , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...