2.
Foot Ankle Int ; 30(12): 1207-11, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20003881

RESUMO

BACKGROUND: Tendon transfers are often used in foot and ankle surgery. Different fixation devices and techniques have been described. The most recently developed ones are bone anchors and interference screws. MATERIALS AND METHODS: A biomechanical study was designed to compare tendon transfer fixation, using Corkscrew bone anchors 5 x 15.5 mm and Bio-interference screws (8 x 23 mm). Fifteen fresh cadaver specimens underwent both fixation techniques for split anterior tibial tendon transfer at the cuboid bone. All the specimens underwent standardized X-rays in order to evaluate mineral bone density using a standardized measurement system. All were tested until maximal load to failure. RESULTS: The ultimate load to failure of the tendon secured to the cuboid using anchors was 103 N (SD, 52), compared with 150 N (SD, 68) for tendons secured to the bone with interference screws (p = 0.003). No difference was found between the techniques that could be related to bone density. CONCLUSION: Interference screws provided greater strength than bone anchors. CLINICAL RELEVANCE: This study demonstrated increased strength in securing bone to tendon in vitro for SPLATT tendon transfer with interference screws as compared to suture anchors.


Assuntos
Parafusos Ósseos , Teste de Materiais , Âncoras de Sutura , Transferência Tendinosa/instrumentação , Fenômenos Biomecânicos , Cadáver , Humanos , Estresse Mecânico , Ossos do Tarso/cirurgia
3.
J Arthroplasty ; 23(2): 299-303, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18280428

RESUMO

At our institution, we have used Endo-Model prostheses (Waldermar Link GmbH & Co, Hamburg, Germany) for difficult knee reconstructions. These rotating-hinge prostheses have an antidislocation feature that prevents dislocation due to distraction disengagement. In a series of 192 consecutive prostheses, we have identified 2 cases of femorotibial dislocations. An increased flexion laxity allows excessive distraction and hence implant dislocation after antidislocation feature loosening. To our knowledge, there are no other reports in the literature regarding dislocation of a rotating-hinge knee prosthesis with antidislocation design.


Assuntos
Artroplastia do Joelho , Luxação do Joelho/etiologia , Prótese do Joelho , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Desenho de Prótese