Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Build Environ ; 202: 108042, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34127877

RESUMO

Reducing the transmission of SARS-CoV-2 through indoor air is the key challenge of the COVID-19 pandemic. Crowded indoor environments, such as schools, represent possible hotspots for virus transmission since the basic non-pharmaceutical mitigation measures applied so far (e.g. social distancing) do not eliminate the airborne transmission mode. There is widespread consensus that improved ventilation is needed to minimize the transmission potential of airborne viruses in schools, whether through mechanical systems or ad-hoc manual airing procedures in naturally ventilated buildings. However, there remains significant uncertainty surrounding exactly what ventilation rates are required, and how to best achieve these targets with limited time and resources. This paper uses a mass balance approach to quantify the ability of both mechanical ventilation and ad-hoc airing procedures to mitigate airborne transmission risk in the classroom environment. For naturally-ventilated classrooms, we propose a novel feedback control strategy using CO2 concentrations to continuously monitor and adjust the airing procedure. Our case studies show how such procedures can be applied in the real world to support the reopening of schools during the pandemic. Our results also show the inadequacy of relying on absolute CO2 concentration thresholds as the sole indicator of airborne transmission risk.

2.
Sci Total Environ ; 712: 135673, 2020 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-31810696

RESUMO

Indoor school gyms are environments characterized by high concentrations of different airborne particulate and gaseous pollutants. In particular, like other naturally-ventilated school environments, in addition to indoor pollutants children can be exposed to sub-micron particles and gaseous pollutants emitted by outdoor sources and penetrating the building envelope; moreover, high concentrations of super-micron particles can be reached due to the resuspension phenomena related to the physical activity performed therein. The present paper aims to evaluate the effect of different ventilation methods (natural ventilation, manual airing) and the use of air purifiers in reducing the indoor concentrations of different airborne particles and gaseous pollutants in school gyms. To this end, an experimental campaign was performed in two naturally-ventilated school gyms in Barcelona (Spain) of different volumes and different distance to major urban roads. Indoor and outdoor measurements of particle number, black carbon and PM1-10 concentrations were performed as well as indoor measurements of CO2 and NO2 concentrations. The study revealed that the use of air purifiers with windows kept closed (natural ventilation) can lead to a significant reduction in terms of indoor-to-outdoor concentration ratios. In the smaller gym (air changes per hour of the purifiers, ACH, equal to 9.2 h-1) the I/O ratios were reduced by 93% and 95% in terms of particle number and PM1-10, respectively; whereas in the larger school gym (ACH = 1.7 h-1) the corresponding reductions were 70% and 84%. For manual airing scenarios, the effect of the air purifiers on outdoor-generated sub-micron particles is reduced; in particular, for low ACH values (i.e. ACH = 1.7 h-1), the reduction is quite negligible (6%).


Assuntos
Filtros de Ar , Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Criança , Monitoramento Ambiental , Gases , Humanos , Tamanho da Partícula , Material Particulado , Instituições Acadêmicas , Espanha , Ventilação
3.
Sci Total Environ ; 650(Pt 1): 1582-1590, 2019 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-30308844

RESUMO

Cycling and walking are promoted as means of transportation which can contribute to the reduction of traffic pollution in urban areas. However, cyclists and pedestrians may be exposed to high concentrations of air pollutants due to their proximity to vehicle emissions. Commercial face mask respirators are widely used, in both developing and developed countries, as an individual protective measure against particle pollution. However scientific data on the efficacy of face mask respirators in reducing airborne particle exposure is limited. In this study, a custom experimental set-up was developed in order to measure the effectiveness of nine different respirators under real environmental conditions in terms of particle mass concentration below 2.5 µm (PM2.5), particle number concentration (PNC), Lung Deposited Surface Area (LDSA) and Black Carbon concentration (BC). Face mask performances were assessed in a typical traffic affected urban background environment in the city of Barcelona under three different simulated breathing rates to investigate the influence of flow rate. Results showed a median face mask effectiveness for PM2.5 equal to 48% in a range of 14-96%, 19% in a range of 6%-61% for BC concentration, 19% in a range of 4%-63% for PNC and 22% in a range of 5%-65% for LDSA. For each pollutant under investigation, the best performance was found always with the same mask (N7) although it is not the most expensive (in a range of price of 1 to 44, its cost was 20 euros), which has a filter on the entire surface except for the 2 exhalation valves where air cannot enter but just exit and shows a good fit on the dummy head.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar/estatística & dados numéricos , Exposição por Inalação/prevenção & controle , Máscaras , Material Particulado/análise , Cidades , Humanos , Exposição por Inalação/estatística & dados numéricos , Roupa de Proteção , Emissões de Veículos/análise
4.
Environ Pollut ; 240: 248-254, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29747109

RESUMO

Smoking activities were recognized as a main risk factor for population. Indeed, mainstream smoke aerosol is directly inhaled by smokers then delivering harmful compounds in the deepest regions of the lung. In order to reduce the potential risk of smoking, different nicotine delivery products have been recently developed. The latest device released is an electrically heated tobacco system (iQOS®, Philip Morris) which is able to warm the tobacco with no combustion. In the present paper a dimensional and volatility characterization of iQOS-generated particles was performed through particle number concentration and distribution measurements in the mainstream aerosol. The experimental analysis was carried out through a condensation particle counter, a fast mobility particle sizer and a thermo-dilution sampling system allowing aerosol samplings at different temperatures. Estimates of the particle surface area dose received by smokers were also carried out on the basis of measured data and typical smoking patterns. The particle number concentrations in the mainstream aerosols resulted lower than 1 × 108 part. cm-3 with particle number distribution modes of about 100 nm. Nonetheless, the volatility analysis showed the high amount of volatile fraction of iQOS-generated particles, indeed, samplings performed at 300 °C confirmed a significant particle shrinking phenomena (modes of about 20 nm). Anyway, the particle number concentration does not statistically decrease at higher sampling temperatures, then showing that a non-volatile fraction is always presents in the emitted particles. The dose received by smokers in terms of non-volatile amount of particle surface area was equal to 1-2 mm2 per puff, i.e. up to 4-fold larger than that received by electronic cigarette vapers.


Assuntos
Aerossóis/análise , Poluentes Atmosféricos/análise , Sistemas Eletrônicos de Liberação de Nicotina , Fumaça/análise , Eletricidade , Temperatura Alta , Humanos , Pulmão/química , Nicotina/análise , Tamanho da Partícula , Fumar , Nicotiana , Produtos do Tabaco , Fumar Tabaco , Volatilização
5.
Sci Total Environ ; 631-632: 1109-1116, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29727937

RESUMO

Combustion-generated nanoparticles are responsible for negative health effects due to their ability to penetrate in the lungs, carrying toxic compounds with them. In urban areas, the coexistence of nanoparticle sources and particular street-building configurations can lead to very high particle exposure levels. In the present paper, an innovative approach for the evaluation of lung cancer incidence in street canyon due to exposure to traffic-generated particles was proposed. To this end, the literature-available values of particulate matter, PAHs and heavy metals emitted from different kind of vehicles were used to calculate the Excess Lifetime Cancer Risk (ELCR) at the tailpipe. The estimated ELCR was then used as input data in a numerical CFD (Computational Fluid Dynamics) model that solves the mass, momentum, turbulence and species transport equations, in order to evaluate the cancer risk in every point of interest inside the street canyon. Thus, the influence of wind speed and street canyon geometry (H/W, height of building, H and width of the street, W) on the ELCR at street level was evaluated by means of a CFD simulation. It was found that the ELCR calculated on the leeward and windward sides of the street canyon at a breathable height of 1.5 m, for people exposed 15 min per day for 20 years, is equal to 1.5 × 10-5 and 4.8 × 10-6, respectively, for wind speed of 1 m/s and H/W equal to 1. The ELCR at street level results higher on the leeward side for aspect ratios equal to 1 and 3, while for aspect ratio equal to 2 it is higher on the windward side. In addition, the simulations showed that with the increasing of wind speed the ELCR becomes lower everywhere in the street canyon, due to the increased in dispersion.


Assuntos
Poluição do Ar/estatística & dados numéricos , Exposição Ambiental/estatística & dados numéricos , Neoplasias Pulmonares/epidemiologia , Modelos Teóricos , Poluentes Atmosféricos/análise , Cidades/epidemiologia , Humanos , Metais Pesados , Material Particulado/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Medição de Risco , Emissões de Veículos/análise , Vento
6.
Sci Total Environ ; 616-617: 720-729, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29089125

RESUMO

Schools represent a critical microenvironment in terms of air quality due to the proximity to outdoor particle sources and the frequent lack of proper ventilation and filtering systems. Moreover, the population exposed in schools (i.e. children) represents a susceptible population due to their age. Air quality-based studies involving students' exposure at schools are still scarce and often limited to mass-based particle metrics and may thus underestimate the possible effect of sub-micron particles and particle toxicity. To this purpose, the present paper aims to evaluate the exposure to different airborne particle metrics (including both sub- and super-micron particles) and attached carcinogenic compounds. Measurements in terms of particle number, lung-deposited surface area, and PM fraction concentrations were measured inside and outside schools in Barcelona (Spain) and Cassino (Italy). Simultaneously, PM samples were collected and chemically analysed to obtain mass fractions of carcinogenic compounds. School time airborne particle doses received by students in classrooms were evaluated as well as their excess lung cancer risk due to a five-year primary school period. Median surface area dose received by students during school time in Barcelona and Cassino resulted equal to 110mm2 and 303mm2, respectively. The risk related to the five-year primary school period was estimated as about 2.9×10-5 and 1.4×10-4 for students of Barcelona and Cassino, respectively. The risk in Barcelona is slightly higher with respect to the maximum tolerable value (10-5, according to the U.S. Environmental Protection Agency), mainly due to toxic compounds on particles generated from anthropogenic emissions (mainly industry). On the other hand, the excess lung cancer risk in Cassino is cause of concern, being one order of magnitude higher than the above-mentioned threshold value due to the presence of biomass burning heating systems and winter thermal inversion that cause larger doses and great amount of toxic compounds on particles.


Assuntos
Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Exposição Ambiental/estatística & dados numéricos , Neoplasias Pulmonares/epidemiologia , Material Particulado/análise , Poluentes Atmosféricos/análise , Poluição do Ar , Criança , Europa (Continente) , Humanos , Itália/epidemiologia , Instituições Acadêmicas , Espanha/epidemiologia
7.
Environ Pollut ; 232: 113-122, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28919325

RESUMO

In the present study, the daily dose in terms of particle surface area received by citizens living in five cities in Western countries, characterized by different lifestyle, culture, climate and built-up environment, was evaluated and compared. For this purpose, the exposure to sub-micron particle concentration levels of the population living in Barcelona (Spain), Cassino (Italy), Guilford (United Kingdom), Lund (Sweden), and Brisbane (Australia) was measured through a direct exposure assessment approach. In particular, measurements of the exposure at a personal scale were performed by volunteers (15 per each population) that used a personal particle counter for different days in order to obtain exposure data in microenvironments/activities they resided/performed. Non-smoking volunteers performing non-industrial jobs were considered in the study. Particle concentration data allowed obtaining the exposure of the population living in each city. Such data were combined in a Monte Carlo method with the time activity pattern data characteristics of each population and inhalation rate to obtain the most probable daily dose in term of particle surface area as a function of the population gender, age, and nationality. The highest daily dose was estimated for citizens living in Cassino and Guilford (>1000 mm2), whereas the lowest value was recognized for Lund citizens (around 100 mm2). Indoor air quality, and in particular cooking and eating activities, was recognized as the main influencing factor in terms of exposure (and thus dose) of the population: then confirming that lifestyle (e.g. time spent in cooking activities) strongly affect the daily dose of the population. On the contrary, a minor or negligible contribution of the outdoor microenvironments was documented.


Assuntos
Poluentes Atmosféricos/análise , Exposição Ambiental/análise , Material Particulado/análise , Poluição do Ar em Ambientes Fechados/análise , Austrália , Cidades , Culinária , Meio Ambiente , Exposição Ambiental/estatística & dados numéricos , Monitoramento Ambiental/métodos , Feminino , Humanos , Itália , Estilo de Vida , Masculino , Método de Monte Carlo , Tamanho da Partícula , Espanha , Suécia , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...