Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Int J Comput Dent ; 0(0): 0, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39011633

RESUMO

AIM: The current study aimed to compare the responses and satisfaction reported by users with varying levels of experience when using different types of computer-aided design (CAD) software programs to design crowns. MATERIALS AND METHODS: A questionnaire was used to evaluate user responses to five domains (software visibility, 3Dscanned data preparation, crown design and adjustment, finish line registration, and overall experience) of various CAD software programs. The study included 50 undergraduate dental students (inexperienced group) and 50 dentists or dental technicians from two hospitals (experienced group). The participants used four different CAD software programs (Meshmixer, Exocad, BlueSkyPlan, and Dentbird) to design crowns and recorded the features using the questionnaire. Statistical analyses included one-way and two-way analysis of variance (ANOVA) tests to compare scores and verify the interaction between user response and experience. RESULT: User evaluation scores in the domains of software visibility and 3D-scanned data preparation varied between software programs (P < 0.001), with Exocad being favored by the experienced group. When evaluating crown design and finish line registration, Dentbird and Exocad scored significantly higher than the other software in both groups as they offered automation of the process using deep learning (P < 0.001). Two-way ANOVA showed that prior experience of using CAD significantly affected the users' responses to all queries (P < 0.001). CONCLUSION: User response and satisfaction varied with the type of CAD software used to design dental prostheses, with prior experience of using CAD playing a significant role. Automation of design functions can enhance user satisfaction with the software.

2.
J Prosthodont ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39010644

RESUMO

PURPOSE: This study aimed to examine the satisfaction of dental professionals, including dental students, dentists, and dental technicians, with computer-aided design (CAD) software performance using deep learning (DL) and explainable artificial intelligence (XAI)-based behavioral analysis concepts. MATERIALS AND METHODS: This study involved 436 dental professionals with diverse CAD experiences to assess their satisfaction with various dental CAD software programs. Through exploratory factor analysis, latent factors affecting user satisfaction were extracted from the observed variables. A multilayer perceptron artificial neural network (MLP-ANN) model was developed along with permutation feature importance analysis (PFIA) and the Shapley additive explanation (Shapley) method to gain XAI-based insights into individual factors' significance and contributions. RESULTS: The MLP-ANN model outperformed a standard logistic linear regression model, demonstrating high accuracy (95%), precision (84%), and recall rates (84%) in capturing complex psychological problems related to human attitudes. PFIA revealed that design adjustability was the most important factor impacting dental CAD software users' satisfaction. XAI analysis highlighted the positive impacts of features supporting the finish line and crown design, while the number of design steps and installation time had negative impacts. Notably, finish-line design-related features and the number of design steps emerged as the most significant factors. CONCLUSIONS: This study sheds light on the factors influencing dental professionals' decisions in using and selecting CAD software. This approach can serve as a proof-of-concept for applying DL-XAI-based behavioral analysis in dentistry and medicine, facilitating informed software selection and development.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38811187

RESUMO

PURPOSE: This study aimed to propose a revision of the evaluation objectives of the Korean Dentist Clinical Skill Test by analyzing the opinions of those involved in the examination after a review of those objectives. METHODS: The clinical skill test objectives were reviewed based on the national-level dental practitioner competencies, dental school educational competencies, and the third dental practitioner job analysis. Current and former examinees were surveyed about their perceptions of the evaluation objectives. The validity of 22 evaluation objectives and overlapping perceptions based on area of specialty were surveyed on a 5-point Likert scale by professors who participated in the clinical skill test and dental school faculty members. Additionally, focus group interviews were conducted with experts on the examination. RESULTS: It was necessary to consider including competency assessments for "emergency rescue skills" and "planning and performing prosthetic treatment." There were no significant differences between current and former examinees in their perceptions of the clinical skill test's objectives. The professors who participated in the examination and dental school faculty members recognized that most of the objectives were valid. However, some responses stated that "oromaxillofacial cranial nerve examination," "temporomandibular disorder palpation test," and "space management for primary and mixed dentition" were unfeasible evaluation objectives and overlapped with dental specialty areas. CONCLUSION: When revising the Korean Dentist Clinical Skill Test's objectives, it is advisable to consider incorporating competency assessments related to "emergency rescue skills" and "planning and performing prosthetic treatment."


Assuntos
Competência Clínica , Avaliação Educacional , Grupos Focais , Humanos , Competência Clínica/normas , República da Coreia , Avaliação Educacional/métodos , Inquéritos e Questionários , Odontólogos , Educação em Odontologia/métodos , Masculino
4.
Int J Comput Dent ; 27(1): 9-18, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-36695628

RESUMO

AIM: To compare the accuracy of three impression methods by comparing the distance between the reference points of the implant fixture, especially in curved maxillary anterior teeth. MATERIALS AND METHODS: Implant fixtures were placed in the maxillary central incisor and canine regions. A maxillary master cast was made using a model scanner and 3D printer. Ten impressions were taken from the three experimental groups constructed (group P: pick-up impression coping; group I: scan body with an intraoral scanner; group B: bite impression coping). The distance between the reference points, the angle between the scan bodies, and displacement of the 3D surface area were measured. RESULTS: The distances between the reference points were significantly different between groups I and B in the maxillary incisors, and between group P and the other two groups in the maxillary canines. Group P had the least amount of displacement in both fixtures. Both fixtures showed the highest displacement in group B. Displacement of the 3D surface area in the maxillary incisors showed no significant difference between the groups. There was a significant difference in the maxillary canines between groups P and I. CONCLUSIONS: In the present study, all three implant impression methods showed changes in the position and angle of the fixture compared with the master cast. The highest accuracy was shown by the impression method using the pick-up impression coping, but the impression method using the intraoral scanner also showed clinically acceptable accuracy. It should be noted that errors may occur when taking impressions using a bite impression coping.


Assuntos
Implantes Dentários , Humanos , Técnica de Moldagem Odontológica , Modelos Dentários , Materiais para Moldagem Odontológica , Incisivo , Desenho Assistido por Computador
5.
Maxillofac Plast Reconstr Surg ; 45(1): 26, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37526800

RESUMO

BACKGROUND: This study aimed to analyze the clinical outcome and complications of narrow-diameter dental implants (NDIs) (diameter ≤3.5 mm). METHODS: The 274 NDIs that met the selection criteria from 2013 to 2018 were included in the retrospective study, and the survival rates (SVR) were compared. Mechanical complications included screw loosening and fractures of the implant components, such as the implant fixture, abutment, and prosthesis. In addition, marginal bone loss (MBL) was measured immediately after surgery and 1 year after loading. RESULTS: The 3-year cumulative SVR was 92.4%. Nineteen fixtures failed during the follow-up. The failure rate was significantly higher (OR=4.573, p<0.05) in smokers and was significantly higher in osteoporosis patients (OR=3.420, p<0.05). The vertical and horizontal values of MBL were 0.33±0.32 mm and 0.18±0.17 mm, respectively. Mechanical complications included screw loosening (5.5%) and porcelain fracture (2.2%), but no fractures of the fixture or components were observed. The choice of titanium and zirconium (TiZr) alloy implant was significantly more frequent in the posterior region. Bone graft was significantly more frequently done in the anterior region. CONCLUSIONS: According to the high SVR and stability of NDIs, the findings of the study suggest that NDIs may be a replacement for regular diameter dental implants (RDIs) and the use of TiZr alloy could extend the indication of NDIs. In the esthetic area, contour augmentation may be a reason for increasing the frequency of bone grafts.

6.
Int J Comput Dent ; 26(1): 37-47, 2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36825566

RESUMO

AIM: The present study aimed to evaluate the marginal and internal fit of lithium disilicate crowns at various locations. MATERIALS AND METHODS: A typodont maxillary left first molar was prepared for a lithium disilicate crown, scanned, and a master die fabricated. Three groups were created according to fabrication method (n = 10): conventional impression and press method (group C); scanning of definitive cast and milling method (group D); and intraoral scanning and milling method (group I). Assessment was performed using the triple-scan protocol. At the buccopalatal and mesiodistal sections, the absolute marginal discrepancy (AMD), marginal gap (MG), axial internal gap (AI), and line angle internal gap (LI) were measured. One-way analysis of variance (ANOVA) and post hoc Tukey HSD tests were used for statistical analysis (α = 0.05). RESULTS: AMD values were significantly lower in group C than in groups D and I (P < 0.05). MG values in group C were significantly lower than those in the buccal and distal areas in group D and all areas in group I (P < 0.05). AI values in the buccal and palatal areas in group D were significantly lower than those in the mesial and distal areas in group D and all areas in groups C and I (P < 0.05). LI values were significantly lower in group C than in groups D and I (P < 0.05). CONCLUSION: All three methods were clinically acceptable except for the marginal fit of the intraoral scanning and milling method, which was on the borderline of a clinically acceptable fit. (Int J Comput Dent 2023;26(1): 37-0; doi: 10.3290/j.ijcd.b3818305).


Assuntos
Cerâmica , Desenho Assistido por Computador , Humanos , Planejamento de Prótese Dentária/métodos , Adaptação Marginal Dentária , Técnica de Moldagem Odontológica , Porcelana Dentária , Coroas
7.
J Prosthodont ; 29(2): 185-189, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31919939

RESUMO

The articulator is a prerequisite device for the analysis of occlusion and prosthodontic treatment, and it is required to simulate patient jaw movements. This article describes the technique to obtain sagittal condylar inclination (SCI) using cone beam computed tomography (CBCT) data and intraoral scan of the protrusive interocclusal position. The SCI can be used on a virtual articulator in a computer-aided design software, and it can assist in the fabrication of prosthesis which is harmonious with the mandibular movement of individual patient.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Articuladores Dentários , Desenho Assistido por Computador , Oclusão Dentária , Humanos , Imageamento Tridimensional , Registro da Relação Maxilomandibular , Mandíbula , Côndilo Mandibular
8.
J Prosthet Dent ; 123(1): 20-26, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31079881

RESUMO

The recent evolution of digital technologies in dentistry has enabled virtual 3D diagnostic analysis of a dentition before treatment, allowing for virtual, minimally invasive treatment planning. In this report, an extensively worn dentition was 3D virtual analyzed at an increased vertical dimension of occlusion. Virtual waxing (exocad DentalCAD; Exocad) and subsequent analysis of the need for minimally invasive preparations were performed. Areas of each tooth without adequate clearance for the minimal thickness of a definitive restoration (set at 1.5 mm in the software), including the amount of tooth substance to be removed (GOM Inspect; GOM), were visualized in color. A preparation guide was virtually designed according to this diagnostic plan (3-matic; Materialise) and 3D printed (Connex3 Objet260; Stratasys) from resin (VeroMagenta RGD851; Stratasys). The teeth were minimally prepared using the guide, and the amount of preparation was validated by superimposing the scan of the prepared model on the initial scan and comparing it with the diagnostic plan.


Assuntos
Atrito Dentário , Desgaste dos Dentes , Humanos , Preparo do Dente , Dimensão Vertical , Fluxo de Trabalho
9.
J Prosthodont ; 28(5): 592-595, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30932267

RESUMO

The conventional method for impressions of flabby tissue uses modified trays and highly flowable materials, but mucostatic impressions are difficult to achieve due to the viscous and the elastic natures of impression materials. In this report, a technique is presented in which conventional impression and intraoral scanning for a fully edentulous patient with flabby tissue are combined. The definitive impression was obtained by applying appropriate pressure to each tissue area, and the denture can be maintained passively and stable at rest and during function.


Assuntos
Técnica de Moldagem Odontológica , Boca Edêntula , Materiais para Moldagem Odontológica , Prótese Total , Humanos
10.
J Adv Prosthodont ; 11(1): 55-64, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30847050

RESUMO

PURPOSE: The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS: The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at α=.05. RESULTS: No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P<.05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P<.05). CONCLUSION: The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.

11.
Int J Oral Maxillofac Implants ; 32(5): 1018­1022, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28518184

RESUMO

PURPOSE: Rotational errors of implants can occur during two stages: when connecting impression copings with implants, and when connecting impression copings with analogs. The aim of this study was to determine ways to minimize these rotational errors. MATERIALS AND METHODS: Three types of implants were prepared: a tissue-level implant with an internal octagon 8-degree Morse taper connection, a bone-level implant with an internal hex 11-degree Morse taper connection, and a bone-level implant with an external hex connection. Each complex (n = 10 per group) was composed of an implant, an impression coping, and an analog. Implants were embedded in resin blocks and connected with corresponding impression copings. Analogs that reproduced the position of the implants were created by means of a custom-made transfer jig, and rotational errors were measured between implants and analogs. Impression copings and analogs were connected by means of four methods: The impression coping was connected to the implant in a clockwise (CW) or a counterclockwise (CCW) direction before tightening, and the analogs were then connected with impression copings and tightened using a hemostat (Hs) or by hand (Hd). RESULTS: The CW-Hs and CCW-Hd groups exhibited low rotational error (mean ± standard deviation 0.11 ± 0.21 and 0.19 ± 0.34 degrees, respectively), whereas the CW-Hd and CCW-Hs groups exhibited high rotational error (-1.80 ± 0.67 and 2.07 ± 0.75, respectively) in different directions. A strong association was observed between the tightening method and rotational error, and a weak association was observed between the connection type and rotational error. CONCLUSION: The CW-Hs method was found to be the most suitable for minimizing rotational error between implants and analogs.

12.
J Prosthet Dent ; 118(5): 584-586, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28385447

RESUMO

Evaluating the cement space of various dental prostheses is important because it is related to the stability and retention of the prosthesis. However, a method for evaluating an overall cement space is complex. The purpose of this technique was to simplify the evaluation of prosthesis cement space by using a digital scanner. The form and thickness of the cement space could be simply recognized in any section the clinician or dental researcher wishes. Moreover, the cement space of several dental prostheses for the same abutment could also be precisely evaluated by superimposition. The method can be applied to various prosthodontic treatments.


Assuntos
Cimentos Dentários/uso terapêutico , Planejamento de Prótese Dentária/métodos , Prótese Dentária/métodos , Desenho Assistido por Computador , Retenção em Prótese Dentária/métodos , Humanos , Imageamento Tridimensional
13.
Implant Dent ; 25(5): 703-6, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27571351

RESUMO

A female patient in her mid-seventies was referred to our department for the removal of a displaced implant within the right posterior mandible. A trapezoidal window was made using a piezoelectric device. The implant was extracted, and the osteotomized window was replaced without fixation. Caution should be exercised during implant placement in patients with osteoporosis because of the risk of implant displacement. Displaced implants can be easily retrieved by piezoelectric trapezoidal osteotomy.


Assuntos
Implantação Dentária Endóssea/métodos , Piezocirurgia/métodos , Levantamento do Assoalho do Seio Maxilar/métodos , Implantação Dentária Endóssea/efeitos adversos , Endoscopia/métodos , Feminino , Humanos , Masculino , Seio Maxilar/patologia , Pessoa de Meia-Idade , Levantamento do Assoalho do Seio Maxilar/efeitos adversos
14.
Implant Dent ; 25(6): 770-774, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27571352

RESUMO

PURPOSE: The aim of this study was to determine the stability of computer-aided design and manufacturing (CAD/CAM) and prefabricated abutment by measuring removal torque before and after cyclic loading. MATERIALS AND METHODS: Three types of fixture and 2 types of abutments were used. Removable torque was measured after cyclic loading for 5000 cycles between 25 and 250 N for each group. The same procedure was performed twice. RESULTS: First, removal torque values (Newton centimeter) were measured for stock versus custom abutments as follows: group 1: 27.17 versus 26.67, group 2: 26.27 versus 26.33, and group 3: 37.33 versus 36.67. Second removal torque values (Newton centimeter) were also measured: group 1: 23 versus 23.5, group 2: 22.5 versus 22.33, and group 3: 32.67 versus 32.5. There was no significant difference between the stock and custom abutments in either the first or second removal torque values and also no significant difference among initial tightening torque, first or second removal torque (P > 0.05). CONCLUSION: With precise control of CAD/CAM abutments, good screw joint stability can be achieved.


Assuntos
Desenho Assistido por Computador , Dente Suporte , Projeto do Implante Dentário-Pivô/métodos , Planejamento de Prótese Dentária/métodos , Parafusos Ósseos , Falha de Restauração Dentária , Análise do Estresse Dentário , Humanos , Torque
15.
J Adv Prosthodont ; 8(4): 329-32, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27555903

RESUMO

Fabricating a surveyed prosthesis beneath an existing partial removable dental prosthesis (PRDP) is a challenging and time-consuming procedure. The computer-aided design/computer-assisted manufacturing (CAD/CAM) technology was applied to fabricate a retrofitted, surveyed zirconia prosthesis to an existing PRDP. CAD/CAM technology enabled precise and easy replication of the contour of the planned surveyed crown on the existing abutment tooth. This technology ensured excellent adaptation and fit of newly fabricated crown to the existing PRDP with minimal adjustments. In this case report, a seventy-year-old male patient presented with fractured existing surveyed crown. Because the existing PRDP was serviceable, new crown was fabricated to the existing PRDP.

16.
J Prosthet Dent ; 115(5): 637-42, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26774316

RESUMO

An obturator prosthesis with insufficient retention and support may be improved with implant placement. However, implant surgery in patients after maxillary tumor resection can be complicated because of limited visibility and anatomic complexity. Therefore, computer-guided surgery can be advantageous even for experienced surgeons. In this clinical report, the use of computer-guided surgery is described for implant placement using a bone-supported surgical template for a patient with maxillary defects. The prosthetic procedure was facilitated and simplified by using computer-aided design/computer-aided manufacture (CAD/CAM) technology. Oral function and phonetics were restored using a tooth- and implant-supported obturator prosthesis. No clinical symptoms and no radiographic signs of significant bone loss around the implants were found at a 3-year follow-up. The treatment approach presented here can be a viable option for patients with insufficient remaining zygomatic bone after a hemimaxillectomy.


Assuntos
Desenho Assistido por Computador , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante/métodos , Maxila/cirurgia , Procedimentos Cirúrgicos Pré-Protéticos Bucais/métodos , Obturação do Canal Radicular/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Implantação Dentária Endóssea/métodos , Humanos , Masculino
17.
J Adv Prosthodont ; 7(5): 406-10, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26576258

RESUMO

Russell-Silver syndrome (RSS) is a congenital disease characterized by short stature due to growth hormone deficiency, physical asymmetry, inverted triangular face, micrognathia, prominent forehead, and hypodontia. This case report presents a prosthetic management of a 6-year-old patient with Russell-Silver syndrome treated with overdentures on the maxilla and the mandible using the remaining primary teeth. Subsequent and comprehensive dental management considering the growth and development of a young patient will be necessary.

18.
J Adv Prosthodont ; 6(5): 406-14, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25352963

RESUMO

PURPOSE: The objective of this study was to investigate the biologic effects of enamel matrix derivative (EMD) with different concentrations on cell viability and the genetic expression of human gingival fibroblasts (HGF) to zirconia surfaces. MATERIALS AND METHODS: Immortalized human gingival fibroblasts (HGF) were cultured (1) without EMD, (2) with EMD 25 µg/mL, and (3) with EMD 100 µg/mL on zirconia discs. MTT assay was performed to evaluate the cell proliferation activity and SEM was carried out to examine the cellular morphology and attachment. The mRNA expression of collagen type I, osteopontin, fibronectin, and TGF-ß1 was evaluated with the real-time polymerase chain reaction (RT-PCR). RESULTS: From MTT assay, HGF showed more proliferation in EMD 25 µg/mL group than control and EMD 100 µg/mL group (P<.05). HGFs showed more flattened cellular morphology on the experimental groups than on the control group after 4h culture and more cellular attachments were observed on EMD 25 µg/mL group and EMD 100 µg/mL group after 24h culture. After 48h of culture, cellular attachment was similar in all groups. The mRNA expression of type I collagen increased in a concentration dependent manner. The genetic expression of osteopontin, fibronectin, and TGF-ß1 was increased at EMD 100 µg/mL. However, the mRNA expression of proteins associated with cellular attachment was decreased at EMD 25 µg/mL. CONCLUSION: Through this short term culture of HGF on zirconium discs, we conclude that EMD affects the proliferation, attachment, and cell morphology of HGF cells. Also, EMD stimulates production of extracellular matrix collagen, osteopontin, and TGF-ß1 in high concentration levels. CLINICAL RELEVANCE: With the use of EMD, protective barrier between attached gingiva and transmucosal zirconia abutment may be enhanced leading to final esthetic results with implants.

19.
J Adv Prosthodont ; 6(2): 96-102, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24843393

RESUMO

PURPOSE: This study was performed to characterize the effects of zirconia coated with calcium phosphate and hydroxyapatite compared to smooth zirconia after bone marrow-derived osteoblast culture. MATERIALS AND METHODS: Bone marrow-derived osteoblasts were cultured on (1) smooth zirconia, (2) zirconia coated with calcium phosphate (CaP), and (3) zirconia coated with hydroxyapatite (HA). The tetrazolium-based colorimetric assay (MTT test) was used for cell proliferation evaluation. Scanning electron microscopy (SEM) and alkaline phosphatase (ALP) activity was measured to evaluate the cellular morphology and differentiation rate. X-ray photoelectron spectroscopy (XPS) was employed for the analysis of surface chemistry. The genetic expression of the osteoblasts and dissolution behavior of the coatings were observed. Assessment of the significance level of the differences between the groups was done with analysis of variance (ANOVA). RESULTS: From the MTT assay, no significant difference between smooth and surface coated zirconia was found (P>.05). From the SEM image, cells on all three groups of discs were sporadically triangular or spread out in shape with formation of filopodia. From the ALP activity assay, the optical density of osteoblasts on smooth zirconia discs was higher than that on surface treated zirconia discs (P>.05). Most of the genes related to cell adhesion showed similar expression level between smooth and surface treated zirconia. The dissolution rate was higher with CaP than HA coating. CONCLUSION: The attachment and growth behavior of bone-marrow-derived osteoblasts cultured on smooth surface coated zirconia showed comparable results. However, the HA coating showed more time-dependent stability compared to the CaP coating.

20.
J Prosthet Dent ; 111(2): 159-62, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24286639

RESUMO

With conventional fixed dental prostheses, the interim restoration is a valuable diagnostic tool in the evaluation of esthetics and function. To achieve predictable definitive esthetic results, information about the subgingival and the supragingival contour of a properly designed restoration should be communicated to the dental laboratory technician. The technique described enables the accurate transfer of the soft tissue morphology developed with an interim prosthesis to the definitive cast. This modified definitive cast allows the dental laboratory technician to fabricate a restoration with an emergence profile identical to that of the interim prosthesis.


Assuntos
Coroas , Planejamento de Prótese Dentária , Restauração Dentária Temporária , Gengiva/anatomia & histologia , Modelos Dentários , Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica , Técnicos em Prótese Dentária , Estética Dentária , Técnicas de Retração Gengival/instrumentação , Laboratórios Odontológicos , Metilmetacrilatos/química , Polivinil , Siloxanas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA