Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Biomed Tech (Berl) ; 68(6): 553-561, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37406349

RESUMO

Proximal humeral shaft fractures can be treated with helically deformed bone plates to reduce the risk of iatrogenic nerve lesion. Controversially to this common surgical technique that was first established in 1999, no biomechanical investigation on humeral helical plating is recorded by other reviews, which focus on proximal fractures exclusively. Does an additional scope for shaft fractures reveal findings of helical testing? The present systematic literature review was performed based on guidelines by Kitchenham et al. to systematically search and synthesize literature regarding biomechanical testing of osteosynthetic systems for proximal humeral shaft fractures. Therefore, a systematic approach to search and screen literature was defined beforehand and applied on the findings of the database PubMed®. Synthesized information of the included literature was categorized, summarized and analyzed via descriptive statistics. Out of 192 findings, 22 publications were included for qualitative synthesis. A wide range of different test methods was identified, leading to a suboptimal comparability of specific results between studies. Overall, 54 biomechanical test scenarios were identified and compared. Physiological based boundary conditions (PB-BC) were referenced in 7 publications only. One study of testing straight and helical dynamic compression plates without PB-BCs was identified, showing significant differences under compressional loading. The absence of test standards of specific fields like humeral fractures lead to a high variance in biomechanical testing of osteosynthetic locking plates for proximal humeral shaft fractures. Physiological approaches offer realistic test scenarios but need to be uniformed for enhanced comparability between studies. The impact of helically deformed locking plates under PB-BC was not identified in literature.


Assuntos
Fixação Interna de Fraturas , Fraturas do Úmero , Humanos , Fixação Interna de Fraturas/métodos , Fraturas do Úmero/cirurgia , Placas Ósseas , Bases de Dados Factuais , Úmero , Resultado do Tratamento
2.
Foot Ankle Spec ; : 19386400221136757, 2022 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-36418935

RESUMO

INTRODUCTION: Biomechanical studies have proved that locking plates have better primary stability besides versatility regarding fracture pattern while reducing bone contact and bridging the gap, whereas conventional nonlocking plates (plus lag screw) depend on bone-plate compression. The clinical benefit of locking plates over nonlocking plates remains unanswered, however. Therefore, this retrospective cohort study was set up to test the hypothesis that the use of locking plates for unstable ankle fractures will result in fewer re-displacements, superior bony healing, and functional and clinical outcomes better than observed in the nonlocking cohort. METHODS: Bimalleolar ankle fractures (AO 44-B2) without syndesmotic injury treated with either a locking or a nonlocking plate were included. Groups were compared for complications, bone healing, secondary dislocation, progressions of osteoarthritis, and clinical outcome using patient-reported outcome measures. RESULTS: Data revealed no clinical outcome differences (Olerud-Molander Ankle Score: nonlocking 88.2 ± 14.4, locking 88.8 ± 12.3, P = .69, robust two 1-sided test for equality (RTOST): P = .03; American Orthopaedic Foot and Ankle Score: nonlocking 91.2 ± 12.9, locking 91.8 ± 11.3, P = .96, RTOST: P = .04). Nevertheless, a significant postoperative progression of osteoarthritis was detected in both groups (P = .04). This was independent of implant (P = .16). Although difference was not significant, locking plates were preferred in older (P = .78) and sicker patients (P = .63) and in cases with severer osteoarthritis (P = .16), and were associated with a higher complication rate (P = .42) and secondary dislocation (nonlocking 9.4%, locking 18.2%; P = .42). Re-displacement, however, was not a compelling reason for revision. CONCLUSIONS: The present study shows statistically significant equality of both types of implants. Contrary to our expectation, locking plates seemed to be associated with a higher risk for re-displacement. Overall, the use of either locking or nonlocking plates for unstable AO 44-B2 fractures is safe and successful despite significant progression of osteoarthritis. LEVEL OF EVIDENCE: III, Retrospective observational cohort study.

3.
Medicine (Baltimore) ; 101(3): e28626, 2022 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-35060540

RESUMO

ABSTRACT: Guided growth by temporary hemiepiphysiodesis (HEPD) is established for the alignment of lower limb angular deformities. This retrospective cohort study was designed to assess the effect of HEPD in idiopathic coronal plane deformities around the knee and on the frontal knee joint line orientation, and to test the frontal knee joint line as predictive means for recurrence.Fourty-four patients (78 deformities: valgus n = 64, varus n = 14) were enrolled in the retrospective observational study. Mechanical axis deviation, mechanical lateral distal femoral angle, and mechanical medial proximal tibial angle were assessed prior to surgery and during follow-up. The facultative frontal knee joint line angle (FKJLA) was used as predictive tool. Cases of remaining growth potential (n = 45/78) after implant removal were followed to assess rebound deformity.Pre-operative angles of the mechanical axis were corrected average 9.0 months after HEPD. Pre-operative assessment of the frontal knee joint line revealed a mean of 3.9° in valgus, and -1.0° in varus deformities. At time of complete deformity correction, mean FKJLA was -0.2° in valgus, and -0.8° in varus deformities. Mean shift of FKJLA was significantly higher after singleHEPD compared to combiHEPD (P < .001). Patients having an unphysiological FKJLA (>/<0°-3°) after correction of mechanical axis had a significantly higher risk of rebound deformity (P = .01). Regression analysis showed a 60.5% higher risk of rebound deformity per each degree deviating from the FKJLA physiological range. Age, gender, or body mass index had no impact.Temporary HEPD offers great potential for the correction of the mechanical axis and the frontal knee joint line. An unphysiological change of the frontal knee joint line is associated with a high risk of recurrent angular deformities. CombiHEPD instead of singleHEPD seems to be safer to prevent detrimental frontal knee joint line shift.Level of Evidence: Retrospective comparative therapeutic study, Level III.


Assuntos
Doenças do Desenvolvimento Ósseo/diagnóstico por imagem , Doenças do Desenvolvimento Ósseo/cirurgia , Articulação do Joelho/cirurgia , Extremidade Inferior/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Tíbia/cirurgia , Adolescente , Criança , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Extremidade Inferior/cirurgia , Masculino , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Resultado do Tratamento
4.
Oncotarget ; 6(18): 16517-26, 2015 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-26203049

RESUMO

Cancer proteomics provide a powerful approach to identify biomarkers for personalized medicine. Particularly, biomarkers for early detection, prognosis and therapeutic intervention of bone cancers, especially osteosarcomas, are missing. Initially, we compared two-dimensional gel electrophoresis (2-DE)-based protein expression pattern between cell lines of fetal osteoblasts, osteosarcoma and pulmonary metastasis derived from osteosarcoma. Two independent statistical analyses by means of PDQuest® and SameSpot® software revealed a common set of 34 differentially expressed protein spots (p < 0.05). 17 Proteins were identified by mass spectrometry and subjected to Ingenuity Pathway Analysis resulting in one high-ranked network associated with Gene Expression, Cell Death and Cell-To-Cell Signaling and Interaction. Ran/TC4-binding protein (RANBP1) and Cathepsin D (CTSD) were further validated by Western Blot in cell lines while the latter one showed higher expression differences also in cytospins and in clinical samples using tissue microarrays comprising osteosarcomas, metastases, other bone malignancies, and control tissues. The results show that protein expression patterns distinguish fetal osteoblasts from osteosarcomas, pulmonary metastases, and other bone diseases with relevant sensitivities between 55.56% and 100% at ≥87.50% specificity. Particularly, CTSD was validated in clinical material and could thus serve as a new biomarker for bone malignancies and potentially guide individualized treatment regimes.


Assuntos
Neoplasias Ósseas/patologia , Catepsina D/biossíntese , Neoplasias Pulmonares/secundário , Proteínas Nucleares/biossíntese , Osteossarcoma/patologia , Biomarcadores Tumorais/biossíntese , Biomarcadores Tumorais/genética , Catepsina D/genética , Linhagem Celular Tumoral , Eletroforese em Gel Bidimensional , Perfilação da Expressão Gênica , Humanos , Neoplasias Pulmonares/patologia , Espectrometria de Massas , Proteínas de Neoplasias/genética , Proteínas Nucleares/genética , Osteoblastos/metabolismo , Proteômica , Análise Serial de Tecidos
5.
Surg Innov ; 20(6): 607-13, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23470557

RESUMO

Total hip replacements for older patients are usually cemented to ensure high postoperative primary stability. Curing temperatures vary with implant material and cement thickness (30°C to 70°C), whereas limits for the initiation of thermal bone damage are reported at 45°C to 55°C. Thus, optimizing surgical treatment and the implant material are possible approaches to lower the temperature. The aim of this study was to investigate the influence of water cooling on the temperature magnitude at the acetabulum cement interface during curing of a modular cobalt-chromium cup and a monoblock polyethylene acetabular cup. The curing temperature was measured for SAWBONE and human acetabuli at the cement-bone interface using thermocouples. Peak temperature for the uncooled condition reached 70°C for both cup materials but was reduced to below 50°C in the cooled condition for the cobalt-chromium cup (P = .027). Cooling is an effective method to reduce curing temperature with metal implants, thereby avoiding the risk of thermal bone damage.


Assuntos
Ligas de Cromo/química , Prótese de Quadril , Polietileno/química , Cimentos Ósseos , Temperatura Baixa , Teste de Materiais , Desenho de Prótese
6.
Open Orthop J ; 6: 419-23, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23002413

RESUMO

Osteosynthesis of intraarticular tibial pilon fractures is preferably achieved using locking plates via a minimally invasive technique. If combined with severe soft tissue damage there is a high risk of wound-healing deficits after plate osteosynthesis. Thus our aim was to find an alternative method of treatment for those cases with combined soft tissue injuries.We report on five cases with comminuted fractures of the joint surface combined with critical soft tissue condition that were treated with lag screws and external fixation (AO) applied across the ankle joint. All five patients were followed up, undergoing clinical and radiological examination.Using this approach we achieved fracture healing of comminuted fractures without further complications. Clinical follow-up after an average of 55.6 (36-75) months revealed a mean AOFAS score of 81 (62-100).We therefore propose combined treatment using lag screws with external fixation as a practical treatment option for those fractures for which lag screws combined with a locking plate are not feasible or when there is a high risk of wound-healing deficits due to severe soft tissue damage.

7.
BMC Musculoskelet Disord ; 13: 141, 2012 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-22873207

RESUMO

BACKGROUND: A minimal invasive approach for elective hip surgery has been implemented in our institution in the past. It is widely hypothesized that implanting artificial hips in a minimal invasive fashion decreases surgical trauma and is helpful in the rehabilitation process in elective hip surgery. Thereby geriatric patients requiring emergency hip surgery also could theoretically benefit from a procedure that involves less tissue trauma. METHODS: Sixty patients who sustained a fractured neck of femur were randomly assigned into two groups. In the minimal invasive arm, the so called "direct anterior approach" (DAA) was chosen, in the conventional arm the Watson-Jones-Approach was used for implantation of a bipolar hemi-arthroplasty.Primary outcome parameter was the mobility as measured by the four-item-Barthel index. Secondary outcome parameters included pain, haemoglobin-levels, complications, duration of surgery, administration of blood transfusion and external length of incision. Radiographs were evaluated. RESULTS: A statistically significant difference (p = 0,009) regarding the mobility as measured with the four-item Barthel index was found at the 5th postoperative day, favouring the DAA. Evaluation of the intensity of pain with a visual analogue scale (VAS) showed a statistically significant difference (p = 0,035) at day 16. No difference was evident in the comparison of radiographic results. CONCLUSIONS: Comparing two different approaches to the hip joint for the implantation of a bipolar hemi-arthroplasty after fractured neck of femur, it can be stated that mobilization status is improved for the DAA compared to the WJA when measured by the four-item Barthel index, there is less pain as measured using the VAS. There is no radiographic evidence that a minimal invasive technique leads to inferior implant position. LEVEL OF EVIDENCE: Level II therapeutic study.


Assuntos
Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/métodos , Articulação do Quadril/cirurgia , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Avaliação da Deficiência , Feminino , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/fisiopatologia , Consolidação da Fratura , Alemanha , Hemiartroplastia/efeitos adversos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos , Limitação da Mobilidade , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Radiografia , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento
8.
J Orthop Surg Res ; 7: 20, 2012 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-22607715

RESUMO

BACKGROUND: Non-union continues to be one of the orthopedist's greatest challenges. Despite effective culture methods, the detection of low-grade infection in patients with non-union following tibial fracture still presents a challenge. We investigated whether "aseptic" tibial non-union can be the result of an unrecognized infection. METHODS: A total of 23 patients with non-union following tibial shaft fractures without clinical signs of infection were investigated. Intraoperative biopsy samples obtained from the non-union site were examined by means of routine culture methods and by polymerase chain reaction (PCR) for the detection of 16 S ribosomal RNA (rRNA). Control subjects included 12 patients with tibial shaft fractures. RESULTS: 23 patients (8 women and 15 men; mean age: 47.4 years) were included into this study. Preoperative C-reactive protein levels (mean: 20.8 mg/l) and WBC counts (mean: 8,359/µl) in the study group were not significantly higher than in the control group. None of the samples of non-union routine cultures yielded microorganism growth. Bacterial isolates were found by conventional culturing methods in only 1 case of an open fracture from the control group. In this case, PCR yielded negative results. 16 S rRNA was detected in tissue specimens from 2 patients (8.7%) with non-union. The analysis of these variable species-specific sequences enabled the identification of specific microorganisms (1x Methylobacterium species, 1x Staphylococcus species). Both PCR-positive patients were culture-negative. CONCLUSIONS: The combination of microbiological culture and broad-range PCR seems to substantially add to the number of microbiological diagnoses obtained and may improve the clinician's ability to tailor therapy to the individual patient's needs.


Assuntos
Técnicas de Tipagem Bacteriana/métodos , Fraturas não Consolidadas/microbiologia , Methylobacterium/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Staphylococcus/isolamento & purificação , Fraturas da Tíbia/microbiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Tipagem Bacteriana/normas , Técnicas de Cultura/métodos , Técnicas de Cultura/normas , Feminino , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase/normas , Radiografia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia
9.
Cases J ; 2: 8545, 2009 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-19830080

RESUMO

INTRODUCTION: Diaphragmatic ruptures are a rare condition with an incidence of about 0.8-5.8% after blunt thoracoabdominal trauma. Right sided ruptures accompanied by a displacement of intraabdominal organs are very uncommon and account for approximately 5-19% of all diaphragmatic ruptures. The majority of diaphragmatic ruptures are based on high speed motor vehicle accidents (MVA) and high falls. CASE PRESENTATION: Herein we report a case of a 58-year old woman after a high-speed MVA with a right-sided diaphragmatic rupture and displacement of the liver into the thorax, mimicking a pleural effusion. CONCLUSION: Due to the low incidence and frequently present masking injuries, diagnosis is difficult and virtually always delayed. Thus, a high index of suspicion is important in cases of blunt thoracoabdominal trauma, as the 24 h mortality-rate of a right sided diaphragmatic rupture is up to 30%. In these situations a spiral CT-scan is the diagnostic tool of choice. Surgical intervention using an abdominal approach via a hockey-stick shaped incision is necessary even for small tears. Part of the polytrauma management following high speed MVAs is a critical review of the radiologic imaging.

10.
J Pediatr Orthop B ; 18(6): 296-301, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19620894

RESUMO

Twenty-eight patients with 31 closed fractures (27 acute fractures and four with malalignment after conservative treatment) of the metacarpal bones 2-5 were treated with only one elastic stable intramedullary nail and followed prospectively. Treatment protocol was without immobilization or physiotherapy. These patients were reviewed at a mean follow-up time of 15 months for ultrasound results as well as functional outcome concerning complications, pain, range of motion, and grip strength measured with a Vernier-Dynamometer. Satisfaction of the patients was investigated by Clients Satisfaction Questionnaire. Radiographs before nail removal, ultrasound, and clinical examination always showed complete union of the fracture without deviation of axis. All patients gained full range of motion without any limits in daily activity and sports. There was no loss of grip strength compared with the other hand. Patients' satisfaction was very high, especially because of almost no postoperative pain and lack of immobilization. This method can be offered as an effective and safe alternative in the treatment of closed displaced fractures of the 2-5 metacarpus without significant complications.


Assuntos
Fixação Intramedular de Fraturas/métodos , Fraturas Fechadas/cirurgia , Ossos Metacarpais/lesões , Adolescente , Pinos Ortopédicos , Criança , Feminino , Fixação Intramedular de Fraturas/instrumentação , Fraturas Fechadas/diagnóstico por imagem , Força da Mão/fisiologia , Humanos , Masculino , Ossos Metacarpais/diagnóstico por imagem , Ossos Metacarpais/cirurgia , Satisfação do Paciente , Estudos Prospectivos , Radiografia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Inquéritos e Questionários , Resultado do Tratamento
11.
Eur J Med Res ; 14(6): 264-71, 2009 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-19541587

RESUMO

INTRODUCTION: At present there are no reliable non-traumatic and non- invasive methods to analyse the healing process and loosening status after total hip replacement. Therefore early as well as late loosening of prosthesis and interface component problems are difficult to be found or diagnosed at any time. METHODS: In a cadaver study the potential application of Resonance Frequency Monitoring (RFM) will be evaluated as a non-invasive and non-traumatic method to monitor loosening and interface problems in hip replacement. In a 65 year old female cadaver different stability scenarios for a total hip replacement (shaft, head/modular head and cup, ESKA, Luebeck, Germany) are simulated in cemented and cement less prosthesis and then analysed with RFM. The types of stability vary from secure/press-fit to interface-shaft disruption. RESULTS: The RFM shows in cemented as well as cement less prosthesis significant intra-individual differences in the spectral measurements with a high dynamic (20 dB difference corresponding to the factor 100 (10000%)), regarding the simulated status of stability in the prosthesis system. CONCLUSION: The results of the study demonstrate RFM as a highly sensitive non-invasive and non-traumatic method to support the application of RFM as a hip prosthesis monitoring procedure. The data obtained shows the possibility to use RFM for osteointegration surveillance and early detection of interface problems, but will require further evaluation in clinical and experimental studies.


Assuntos
Acústica , Artroplastia de Quadril , Prótese de Quadril , Teste de Materiais/métodos , Falha de Prótese , Idoso , Cimentos Ósseos , Cadáver , Cimentação , Feminino , Humanos , Teste de Materiais/instrumentação
12.
Eur J Trauma Emerg Surg ; 34(4): 391-6, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26815817

RESUMO

The objective of this study is to determine the treatment result of severe fractures of the tibial pilon using a two-stage treatment plan with a singular implant type. The setting is a level 1 trauma centre, the design a consecutive series of patients with a retrospective data evaluation. Due to anatomical circumstances, soft-tissue treatment is extremely important for fractures of the tibial plafond. After promising results reported about a two-staged treatment plan with external fixation and secondary internal fixation, we incorporated this method in our treatment protocol. This consisted in a second stage of internal fixation with a specifically developed locked pilon plate with multi-directional applicable screws. Between March 2000 and February 2005, 42 patients with high-energy fractures of the tibial plafond were treated using a two-staged treatment plan: firstly the fracture was stabilized with an external fixator immobilizing the ankle joint. Secondly, after stabilization of the soft-tissue situation (mean 9.2 days) open reduction and internal fixation with a locked-screw plate was performed. Complications experienced included three cases of superficial wound necrosis, in two cases a deep vein thrombosis occurred. All fractures healed but two patients needed an early bone graft because of insufficient bony consolidation. At follow-up, six Patients had no deficit in the range of movement of the ankle compared with the unaffected side, 19 patients experienced a deficit of movement of less then one third compared to the opposite side. In 27 cases no or only mild posttraumatic arthritis of the ankle occurred. There was no secondary loss of reduction or need for arthrodesis. The mean AOFAS score was 73.4 (52-97). A two-stage treatment plan in fractures of the distal lower limb with external fixation followed by locked-plate osteosynthesis reduces local complications with a good functional result.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...