Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
EJNMMI Res ; 10(1): 61, 2020 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-32533449

RESUMO

BACKGROUND: 4-[18F] fluorobenzyl dexetimide (F-DEX) is the first non-subtype selective fluorine-18 labelled tracer for muscarinic receptors (mAChR) used in humans. A recent first-in-human study found high regional brain uptake with low variation in normal subjects. Disturbance of mAChR has been reported in Alzheimer's and Parkinson's disease, schizophrenia and depression and various cardiac diseases. The following work assesses the biodistribution, organ tracer kinetics and radiation dose associated with F-DEX. METHOD: Dose calculations were based on activity uptake derived from multiple time point whole body PET CT imaging and the organ-specific dosimetric S-factors derived from the ICRP 133 standard man and woman mathematical phantoms. Effective doses were calculated using the latest ICRP tissue weighting factors. RESULTS: Serial images and time activity curves demonstrate high brain and left ventricular myocardial uptake (5% and 0.65% of injected activity, respectively) with greater retention in brain than myocardium. The mean effective dose was in concordance with other 18F labelled tracers at 19.70 ± 2.27 µSv/MBq. The largest absorbed doses were in the liver (52.91 ± 1.46 µGy/MBq) and heart wall (43.94 ± 12.88 µGy/MBq) for standard man and the liver (61.66 ± 13.61 µGy/MBq) and lungs (40.93 ± 3.11 µGy/MBq) for standard woman. The absorbed dose to all organs, most notably, the red bone marrow (20.03 ± 2.89 µGy/MBq) was sufficiently low to ensure no toxicity after numerous follow-up procedures. CONCLUSIONS: The radiation dose associated with an administration of F-DEX is comparable to that of other 18F labelled tracers such as FDG (19.0 µSv/MBq) and lower than tracers used for SPECT imaging of muscarinic receptors (I-DEX 28.5 µSv/MBq). Clinical use would likely result in an effective dose less than 4 mSv for the ICRP 133 standard phantoms after dose optimisation allowing justification for numerous follow-up procedures. Recent results from first in-human studies and a comparatively low radiation dose make F-DEX an attractive option for future applications of imaging muscarinic receptors in the brain. Further investigation of the potential of F-DEX for imaging parasympathetic innervation of the heart may be warranted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...