1.
Eur J Radiol ; 55(2): 264-9, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16036158

RESUMO

OBJECTIVE: The aim of the present study was to evaluate the efficacy of two different computer aided detection (CAD) systems for mammography in improving radiological diagnosis in the search of microcalcification clusters. The CAD systems used are: the SecondLooktrade mark (CADx Medical Systems, Canada) commercial system and the CALMA (computer assisted library in MAmmography) research CAD system. Three radiologists were asked to read mammographic images with and without the support of the CAD systems. MATERIAL AND METHODS: Three radiologists with respectively 3, 5 and 7 years of practice in mammogram reading in an Italian public hospital analysed a dataset composed of 120 digitized mammograms of healthy subjects with no lesion (proven by a radiological follow up of at least 3 years) and 70 images of patients with malignant cluster of microcalcification (proven by histopathological examination) both with no CAD support as well as with the help of the SecondLooktrade mark system. After 3 months they were asked to observe the same digitized mammograms with the assistance of the CALMA system. The radiologists worked independently and were unaware of the final diagnosis. The values of the area A(z) under the ROC curve, diagnostic sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy were evaluated with and without the support of the CAD systems. The reading time and qualitative evaluations of each radiologist were also reported. RESULTS: With the support of the two CAD systems an improvement in A(z) area was obtained ranging from 0.01 to 0.04. Sensitivity increased from +8.6 to +15.7% and specificity decreased from 0.8 to 4.2%. CONCLUSION: In our study, not conditioned by the dataset, the CAD systems as second reader produced an increase in overall sensitivity of up to 15.7%, with a little decrease in specificity of up to 4.2%. Based on these results both CAD systems might be used in the current practise to improve the sensitivity values of conventional reading (radiologist alone). The results of this study show that no significant differences exist in term of A(z), sensitivity and specificity between CALMA and CADx.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Mamografia/instrumentação , Calcinose/diagnóstico por imagem , Diagnóstico por Computador , Feminino , Humanos , Valor Preditivo dos Testes , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade , Software
2.
Methods Inf Med ; 44(2): 244-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15924184

RESUMO

OBJECTIVES: The next generation of high energy physics (HEP) experiments requires a GRID approach to a distributed computing system: the key concept is the Virtual ORGANISATION (VO), a group of distributed users with a common goal and the will to share their resources. METHODS: A similar approach, applied to a group of hospitals that joined the GPCALMA project (Grid Platform for Computer Assisted Library for MAmmography), will allow common screening programs for early diagnosis of breast and, in the future, lung cancer. The application code makes use of neural networks for the image analysis and is useful in improving the radiologists' diagnostic performance. GRID services allow remote image analysis and interactive online diagnosis, with a potential for a relevant reduction of the delays presently associated with screening programs. RESULTS AND CONCLUSIONS: A prototype of the system, based on AliEn GRID Services [1], is already available, with a central server running common services [2] and several clients connecting to it. Mammograms can be acquired in any location; the related information required to select and access them at any time is stored in a common service called Data Catalogue, which can be queried by any client. Thanks to the PROOF facility [3], the result of a query can be used as input for analysis algorithms, which are executed on the nodes where the input images are stored,. The selected approach avoids data transfers for all the images with a negative diagnosis and allows an almost real time diagnosis for the set of images with high cancer probability.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Internet/instrumentação , Mamografia , Sistemas de Informação em Radiologia/instrumentação , Integração de Sistemas , Telerradiologia/instrumentação , Algoritmos , Sistemas de Gerenciamento de Base de Dados , Bases de Dados Factuais , Diagnóstico por Computador , Europa (Continente) , Feminino , Humanos , Internacionalidade , Itália , Sistemas Computadorizados de Registros Médicos , Desenvolvimento de Programas , Interface Usuário-Computador