1.
J Clin Med ; 13(9)2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38731236

RESUMO

The implantation of cardiac electronic devices (CIEDs), including pacemakers and defibrillators, has become increasingly prevalent in recent years and has been accompanied by a significant rise in cardiac device infections (CDIs), which pose a substantial clinical and economic burden. CDIs are associated with hospitalizations and prolonged antibiotic therapy and often necessitate device removal, leading to increased morbidity, mortality, and healthcare costs worldwide. Approximately 1-2% of CIED implants are associated with infections, making this a critical issue to address. In this contemporary review, we discuss the burden of CDIs with their risk factors, healthcare costs, prevention strategies, and clinical management.

2.
J Clin Med ; 13(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38541971

RESUMO

Ventricular tachycardias (VTs) and electrical storms (ES) are life-threatening conditions mostly seen in the setting of structural heart disease (SHD). Traditional management strategies, predominantly centered around pharmacological interventions with antiarrhythmic drugs, have demonstrated limited efficacy in these cases, whereas catheter ablation is related with more favorable outcomes. However, patients with hemodynamically unstable, recurrent VT or ES may present cardiogenic shock (CS) that precludes the procedure, and catheter ablation in patients with SHD portends a multifactorial intrinsic risk of acute hemodynamic decompensation (AHD), that is associated with increased mortality. In this setting, the use of mechanical circulatory support (MCS) systems allow the maintenance of end-organ perfusion and cardiac output, improving coronary flow and myocardial mechanics, and minimizing the effect of cardiac stunning after multiple VT inductions or cardioversion. Although ablation success and VT recurrence are not influenced by hemodynamic support devices, MCS promotes diuresis and reduces the incidence of post-procedural kidney injury. In addition, MCS has a role in post-procedural mortality reduction at long-term follow-up. The current review aims to provide a deep overview of the rationale and modality of MCS in patients with refractory arrhythmias and/or undergoing VT catheter ablation, underlining the importance of patient selection and timing for MCS and summarizing reported clinical experiences in this field.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38519418

RESUMO

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.

5.
J Cardiovasc Electrophysiol ; 35(3): 379-388, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38185855

RESUMO

BACKGROUND: The mechanism of typical slow-fast atrioventricular nodal re-entrant tachycardia (AVNRT) and its anatomical and electrophysiological circuit inside the right atrium (RA) and Koch's Triangle (KT) are not well known. OBJECTIVE: To identify the potentials of the compact AV node and inferior extensions and to perform accurate mapping of the RA and KT in sinus rhythm (SR) and during AVNRT, to define the tachycardia circuit. METHODS: Consecutive patients with typical AVNRT were enrolled in 12 Italian centers and underwent mapping and ablation by means of a basket catheter with small electrode spacing for ultrahigh-density mapping and a modified signal-filtering toolset to record the potentials of the AV nodal structures. RESULTS: Forty-five consecutive cases of successful ablation of typical slow-fast AVNRT were included. The mean SR cycle length (CL) was 784.1 ± 6 ms and the mean tachycardia CL was 361.2 ± 54 ms. The AV node potential had a significantly shorter duration and higher amplitude in sinus rhythm than during tachycardia (60 ± 40 ms vs. 160 ± 40 ms, p < .001 and 0.3 ± 0.2 mV vs. 0.09 ± 0.12 mV, p < .001, respectively). The nodal potential duration extension was 169.4 ± 31 ms, resulting in a time-window coverage of 47.6 ± 9%. The recording of AV nodal structure potentials enabled us to obtain 100% coverage of the tachycardia CL during slow-fast AVNRT. CONCLUSION: Detailed recording of the potentials of nodal structures is possible by means of multipolar catheters for ultrahigh-density mapping, allowing 100% of the AVNRT CL to be covered. These results also have clinical implications for the ablation of right-septal and para-septal arrhythmias.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Nó Atrioventricular/cirurgia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , Eletrodos
6.
Artigo em Inglês | MEDLINE | ID: mdl-37985538

RESUMO

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly employed in atrial fibrillation (AF) ablation procedures, with the potential to enhance procedural efficacy. Nevertheless, there is currently a lack of evidence assessing the impact of ICE on the efficiency, effectiveness, and safety outcomes in the context of novel pulsed-field ablation (PFA) for AF. PURPOSE: We aimed to assess whether the use of ICE could improve procedural parameters in a large population undergoing AF ablation with FARAPULSE™ catheter. METHODS: Consecutive patients who had undergone PFA of AF from nine Italian centers were included. In procedures where the ICE catheter was employed for guidance (ICE-guided group), it was used to maneuver the PFA catheter within the left atrium to achieve optimal contact with atrial structures. RESULTS: We analyzed 556 patients: 357 (66%) with paroxysmal AF, 499 (89.7%) de novo PVI. ICE-guided procedures (n = 138) were propensity matched with patients with a standard approach (n = 138), and their outcomes were compared. During ICE-guided procedures, no improvement in procedural metrics was recorded (ICE vs Standard, 23 ± 6 min vs 18.5 ± 9 min for time to PVI, p < 0.0001; 38.8 ± 7 vs 32.5 ± 5 number of PFA deliveries to achieve PVI, p < 0.0001; 68.8 ± 19 min vs 71.8 ± 29 min for primary operator time, p = 0.5301; 16.1 ± 8 min vs 18.2 ± 10 min for fluoroscopy time, p = 0.5476) except for support time (76.8 ± 26 min vs 91.4 ± 37 min, p = 0.0046). No major procedure-related adverse events were reported. CONCLUSION: Our findings confirmed that PFA could be consistently performed in a rapid, safe, and efficacious manner. The use of ICE to guide PFA was not associated with an improvement in procedural metrics.

7.
Front Cardiovasc Med ; 10: 1169037, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37476572

RESUMO

Background: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have the potential to act as a reliable predictor of the durability of the lesions created. Objective: We aimed to collect data on the procedural parameters affecting LI-guided ablation in a large multicenter registry. Methods: A total of 212 consecutive patients enrolled in the CHARISMA registry and undergoing their first pulmonary vein (PV) isolation for paroxysmal and persistent AF were included. Results: In all, 13,891 radiofrequency (RF) applications of ≥3 s duration were assessed. The first-pass PV isolation rate was 93.3%. A total of 80 PV gaps were detected. At successful ablation spots, baseline LI and absolute LI drop were larger than at PV gap spots (161.4 ± 19â€…Ω vs. 153.0 ± 13 Ω, p < 0.0001 for baseline LI; 22.1 ± 9â€…Ω vs. 14.4 ± 5 Ω, p < 0.0001 for LI drop). On the basis of Receiver operating characteristic curve analysis, the ideal LI drop, which predicted successful ablation, was >21â€…Ω at anterior sites and >18â€…Ω at posterior sites. There was a non-linear association between the magnitude of LI drop and contact-force (CF) (r = 0.14, 95% CI: 0.13-0.16, p < 0.0001) whereas both CF and LI drop were inversely related with delivery time (DT) (-0.22, -0.23 to -0.20, p < 0.0001 for CF; -0.27, -0.29 to -0.26, p < 0.0001 for LI drop). Conclusion: An LI drop >21â€…Ω at anterior sites and >18â€…Ω at posterior sites predicts successful ablation. A higher CF was associated with an increased likelihood of ideal LI drop. The combination of good CF and adequate LI drop allows a significant reduction in RF DT. Clinical trial registration: http://clinicaltrials.gov/, identifier: NCT03793998.

8.
Heart Rhythm ; 20(4): 614-626, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36634901

RESUMO

Atrioventricular nodal reentrant tachycardia (AVNRT) is the most frequent regular tachycardia in humans. In this review, we describe the most recent discoveries regarding the anatomical, physiological, and molecular biological features of the atrioventricular junction that could underlie the typical slow-fast AVNRT mechanisms, as these insights could lead to the proposal of a new theory concerning the circuit of this arrhythmia. Despite several models have been proposed over the years, the precise anatomical site of the reentrant circuit and the pathway involved in the slow-fast AVNRT have not been conclusively defined. One possible way to evaluate all the hypotheses regarding the nodal tachycardia circuit in humans is to map this circuit. Thus, we tried to identify the slow potential of nodal and inferior extension structures by using automated mapping of atrial activation during both sinus rhythm and typical slow-fast AVNRT. This constitutes a first step toward the definition of nodal area activation in sinus rhythm and during slow-fast AVNRT. Further studies and technical improvements in recording the potentials of the atrioventricular node structures are necessary to confirm our initial results.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Humanos , Nó Atrioventricular , Imunoquímica , Átrios do Coração , Ablação por Cateter/métodos
9.
Minerva Cardiol Angiol ; 71(1): 91-99, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35080355

RESUMO

BACKGROUND: Catheter ablation (CA) of atrial fibrillation (AF) is used routinely to establish rhythm control. There is mounting evidence that CA procedures should be performed during continuous oral anticoagulation and direct oral anticoagulants (DOACs) are considered the first anticoagulation strategy. Few real-life data are now available and even less in the Italian panorama. METHODS: IRIS is an Italian multicenter, non-interventional, prospective study which will be enrolled consecutive AF patients eligible for CA and treated with Rivaroxaban; patients in treatment with Rivaroxaban proceeded directly to CA while Rivaroxaban-naive patients were scheduled for CA after 4 weeks of uninterrupted anticoagulation unless the exclusion of atrial thrombi. Rivaroxaban was uninterrupted or shortly uninterrupted (<24 hours) prior CA, in line with routinely practice of each operator. Patients will be followed on continuous anticoagulation for 1 month after the ablation. The primary efficacy outcome is the cumulative incidence of all-cause death and systemic embolism while the primary safety outcome is the incidence of major bleeding events. The secondary outcomes are represented by non-major bleeding events. All events must be occurred within the first 30 days after the procedure. RESULTS: Two hundred fifty patients are expected to be enrolled and the study is estimated to be completed by the end of 2022. Up to now 56 patients have been enrolled. CONCLUSIONS: This study is the first large Italian prospective study on the management of Rivaroxaban in patients undergoing CA of AF. It aims to depict a comprehensive view of anticoagulation strategy prior CA in several Italian electrophysiology labs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Rivaroxabana/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Inibidores do Fator Xa/efeitos adversos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Hemorragia/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros
10.
J Interv Card Electrophysiol ; 63(3): 749-758, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35322330

RESUMO

PURPOSE: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have emerged as a viable real-time indicator of tissue characteristics and the consequent durability of the lesions created. We investigated the impact of catheter-tissue contact force (CF) on LI behavior during pulmonary vein isolation (PVI). METHODS: Forty-five consecutive patients of the CHARISMA registry undergoing de novo AF radiofrequency (RF) catheter ablation with a novel open-irrigated-tip catheter endowed with CF and LI measurement capabilities (Stablepoint™ catheter, Boston Scientific) were included. RESULTS: A total of 2895 point-by-point RF applications were analyzed (RF delivery time (DT) = 8.7±4s, CF = 13 ±±8 g, LI drop = 23 ±±7 Ω). All PVs were successfully isolated in an overall procedure time of 118 ±±34 min (fluoroscopy time = 13 ±±8 min). The magnitude of LI drop weakly correlated with CF (r = 0.13, 95% confidence interval (CI): 0.09 to 0.16, p < 0.0001), whereas both CF and LI drop inversely correlated with DT (r = -0.26, 95%CI: -0.29 to -0.22, p < 0.0001 for CF; r = -0.36, 95%CI: -0.39 to -0.33, p < 0.0001 for LI). For each 10 g of CF, LI drop markedly increased from 22.4 ± 7 Ω to 24.0 ± 8 Ω at 5 to 25 g CF intervals (5-14 g of CF vs 15-24 g of CF, p < 0.0001), whereas it showed smooth transition over 25 g (24.8 ± 7Ω at ≥ 25 g CF intervals, p = 0.0606 vs 15-24 g of CF). No major complications occurred during the procedures or within 30 days. CONCLUSIONS: CF significantly affects LI drop and probable consequent lesion formation during RF PVI. The benefit of higher contact (> 25 g) between the catheter and the tissue appears to have less impact on LI drop. TRIAL REGISTRATION: Catheter Ablation of Arrhythmias With High Density Mapping System in the Real World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Impedância Elétrica , Humanos , Veias Pulmonares/cirurgia , Sistema de Registros , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 44(12): 2031-2040, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34606098

RESUMO

BACKGROUND: An early, comprehensive rhythm-control therapy is needed in order to treat atrial fibrillation (AF) effectively and to improve ablation outcomes. METHODS: A total of 153 consecutive patients from the CHARISMA registry undergoing AF ablation at eight centers were included. Patients with de novo PVI were classified as having undergone early treatment (ET) if the procedure was performed within 6 months after the first AF episode, and as having undergone delayed treatment (DT) if ablation was performed over 6 months after the first AF episode. RESULTS: One-hundred fifty-three patients were enrolled (69.9% male, 59 ± 10 years, 61.4% paroxysmal AF, 38.6% persistent AF). The time from the first AF episode to the ablation procedure was 1034 ± 1483 days. The ET group comprised 36 patients (25.3%), the DT group 60 (39.2%) and Redo cases were 57 (37.3%). During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/AT recurrence. More DT patients than ET patients suffered recurrences (15.7% vs. 2.2%, p = 0.0452) and the time to AT/AF recurrence was shorter in the group of patients who received an ablation treatment after 6 months (HR = 6.19, 95% CI: 1.7 to 21.9; p = 0.0474). On multivariate Cox analysis, only hypertension (HR = 4.86, 95% CI: 1.6 to 14.98, p = 0.0062) was independently associated with recurrences. Beyond the hypertension risk factor, ET was associated with a low risk of recurrence; recurrence rate ranged from 0% (ET patients without hypertension) to 25.0% (DT patients with hypertension). CONCLUSIONS: An early rhythm-control ablation therapy in the absence of common risk factors was associated with the lowest rate of recurrences.


Assuntos
Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros
12.
J Cardiovasc Electrophysiol ; 32(6): 1540-1548, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33851484

RESUMO

BACKGROUND: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have recently emerged as a viable real-time indicator of tissue characteristics and durability of the lesions created. We report the outcomes of acute and long-term clinical evaluation of the new DirectSense algorithm in AF ablation. METHODS: Consecutive patients undergoing AF ablation were included in the CHARISMA registry. RF delivery was guided by the DirectSense algorithm, which records the magnitude and time-course of the impedance drop. The ablation endpoint was pulmonary vein isolation (PVI), as assessed by the entrance and exit block. RESULTS: 3556 point-by-point first-pass RF applications of >10 s duration were analyzed in 153 patients (mean age=59 ± 10 years, 70% men, 61% paroxysmal AF, 39% persistent AF). The mean baseline LI was 105 ± 15 Ω before ablation and 92 ± 12 Ω after ablation (p < .0001). Both absolute drops in LI and the time to LI drop (LI drop/τ) were greater at successful ablation sites (n = 3122, 88%) than at ineffective ablation sites (n = 434, 12%) (14 ± 8 Ω vs 6 ± 4 Ω, p < .0001 for LI; 0.73 [0.41-1.25] Ω/s vs. 0.35[0.22-0.59 Ω/s, p < .0001 for LI drop/τ). No major complications occurred during or after the procedures. All PVs had been successfully isolated. During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/atrial tachycardia recurrence after the 90-day blanking period. CONCLUSION: The magnitude and time-course of the LI drop during RF delivery were associated with effective lesion formation. This ablation strategy for PVI guided by LI technology proved safe and effective and resulted in a very low rate of AF recurrence over 1-year follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
J Interv Card Electrophysiol ; 61(3): 487-497, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32766944

RESUMO

BACKGROUND: Atrial activation during typical atrioventricular nodal reentrant tachycardia (AVNRT) exhibits anatomic variability and spatially heterogeneous propagation inside the Koch's triangle (KT). The mechanism of the reentrant circuit has not been elucidated yet. Aim of this study is to describe the distribution of Jackman and Haïssaguerre potentials within the KT and to explore the activation mode of the KT, in sinus rhythm and during the slow-fast AVNRT. METHODS: Forty-five consecutive cases of successful slow pathway (SP) ablation of typical slow-fast AVNRT from the CHARISMA registry were included. RESULTS: The KT geometry was obtained on the basis of the electroanatomic information using the Rhythmia mapping system (Boston Scientific) (mean number of points acquired inside the KT = 277 ± 47, mean mapping time = 11.9 ± 4 min). The postero-septal regions bounded anteriorly by the tricuspid annulus and posteriorly by the lateral wall toward the crista terminalis showed a higher prevalence of Jackman potentials than mid-postero-septal regions along the tendon of Todaro and coronary sinus (CS) (98% vs. 16%, p < 0.0001). Haïssaguerre potentials seemed to have a converse distribution across the KT (0% vs. 84%, p < 0.0001). Fast pathway insertion, as located during AVNRT, was mostly recorded in an antero-septal position (n = 36, 80%), rather than in a mid-septal (n = 6, 13.3%) or even postero-septal (n = 3, 7%) location. During typical slow-fast AVNRT, two types of propagation around the CS were discernible: anterior and posterior, n = 31 (69%), or only anterior, n = 14 (31%). During the first procedure, the SP was eliminated, and acute procedural success was achieved (median of 4 [3-5] RF ablations). CONCLUSION: High-density mapping of KT in AVNRT patients both during sinus rhythm and during tachycardia provides new electrophysiological insights. A better understanding and a more precise definition of the arrhythmogenic substrate in AVNRT patients may have prognostic value, especially in high-risk cases. TRIAL REGISTRATION: Catheter Ablation of Arrhythmias With High Density Mapping System in the Real World Practice (CHARISMA) URL: http://clinicaltrials.gov/ Identifier: NCT03793998.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Ventricular , Fascículo Atrioventricular , Átrios do Coração , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
14.
J Cardiovasc Electrophysiol ; 31(9): 2319-2327, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32613661

RESUMO

INTRODUCTION: Recently, a novel technology able to measure local impedance (LI) and tissue characteristics has been made available for clinical use. This analysis explores the relationships among LI and generator impedance (GI) parameters in atrial fibrillation (AF) patients. Characterization of LI among different ablation spots and procedural success were also evaluated. METHODS AND RESULTS: Consecutive patients undergoing AF ablation from the CHARISMA registry at five Italian centers were included. A novel radiofrequency (RF) ablation catheter with a dedicated algorithm (DIRECTSENSE™) was used to measure LI and to guide ablation. The ablation endpoint was pulmonary vein (PV) isolation. We analyzed 2219 ablation spots created around PVs in 46 patients for AF ablation. The mean baseline tissue impedance was 105.8 ± 14 Ω for LI versus 91.8 ± 10 Ω for GI (p < .0001). Baseline impedance was homogenous across the PV sites and proved higher in high-voltage areas than in intermediate- and low-voltage areas and the blood pool (p < .001). Both LI and GI displayed a significant drop after RF delivery, and absolute LI drop values were significantly larger than GI drop values (14 ± 8 vs. 3.7 ± 5 Ω, p < .0001). Every 5-point increment in LI drop was associated with successful ablation (odds ratio = 3.05, 95% confidence interval: 2.3-4.1, p < .0001). Conversely, GI drops were not significantly different comparing successful versus unsuccessful sites (3.7 ± 5 vs. 2.8 ± 4 Ω, p = .1099). No steam pops or major complications occurred during or after the procedures. By the end of the procedures, all PVs had been successfully isolated in all patients. CONCLUSIONS: The magnitude of the LI drop was more closely associated with effective lesion formation than the GI drop.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Humanos , Projetos Piloto , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
15.
Clin Cardiol ; 42(10): 1041-1050, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31411347

RESUMO

Despite the technical improvements made in recent years, the overall long-term success rate of ventricular tachycardia (VT) ablation in patients with ischemic cardiomyopathy remains disappointing. This unsatisfactory situation has persisted even though several approaches to VT substrate ablation allow mapping and ablation of noninducible/nontolerated arrhythmias. The current substrate mapping methods present some shortcomings regarding the accurate definition of the true scar, the modality of detection in sinus rhythm of abnormal electrograms that identify sites of critical channels during VT and the possibility to determine the boundaries of functional re-entrant circuits during sinus or paced rhythms. In this review, we focus on current and proposed ablation strategies for VT to provide an overview of the potential/real application (and results) of several ablation approaches and future perspectives.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Isquemia Miocárdica/complicações , Taquicardia Ventricular/diagnóstico , Humanos , Isquemia Miocárdica/diagnóstico , Prognóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
16.
Pacing Clin Electrophysiol ; 42(7): 1056-1062, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31116439

RESUMO

The mechanisms of atrial fibrillation (AF) induction and maintenance, including those involved in paroxysmal atrial fibrillation, are not completely known; this limits our ablation strategies and prevents us from understanding what we are actually doing when performing pulmonary vein isolation. In this report, we focus on the commonly used ablation strategies for AF and question the importance of complete pulmonary vein isolation in achieving lasting success in the ablation of AF. We also discuss in detail the absence of durable pulmonary vein isolation in patients without arrhythmic recurrences after AF ablation and the possibility to cure paroxysmal AF without concomitant pulmonary vein isolation, provocatively questioning the dogma of pulmonary vein isolation as the cornerstone of AF ablation. Finally, a prospective personalized approach in the individual patient is advocated.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Humanos , Medicina de Precisão , Recidiva
17.
Circ Arrhythm Electrophysiol ; 11(3): e005592, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29874166

RESUMO

BACKGROUND: This multicenter, prospective study evaluated the determinants of zero-fluoroscopy (ZFL) ablation of supraventricular tachycardias. METHODS AND RESULTS: Four hundred thirty patients (215 male, 55.4±22.1 years) with indication to electrophysiological study or ablation of supraventricular tachycardias were enrolled. All participating physicians agreed to follow the as low as reasonably achievable policy. A procedure was defined as ZFL when no fluoroscopy was used. The total fluoroscopy time inversely correlated to the number of procedures previously performed by each operator since study start (r=-0.112; P=0.02). Two hundred eighty-nine procedures (67.2%) were ZFL; multivariable analysis identified as predictors of ZFL: procedure after the 30th for each operator, compared with procedures up to the ninth (P=0.011; hazard ratio, 3.49; 95% confidence interval [CI], 1.79-6.80); the type of arrhythmia (P=0.031; electrophysiological study and atrioventricular nodal reentry tachycardia ablation having the highest probability of ZFL; hazard ratio, 6.87; 95% CI, 2.08-22.7 and hazard ratio, 2.02; 95% CI, 1.04-3.91, respectively); the operator's (P=0.002) and patient's age (P=0.009). Among operators, achievement of ZFL varied from 0% to 100%; 8 (22.8%) operators achieved ZFL in <25% of their procedures; 17 (48.6%) operators achieved ZFL in >75% of their procedures. The probability of ZFL increased by 2.8% (hazard ratio, 0.98; 95% CI, 0.97-0.99) as patient's age decreased by 1 year. Acute procedural success was obtained in all cases. CONCLUSIONS: The use of 3-dimensional mapping system completely avoided the use of fluoroscopy in most cases, with very low fluoroscopy time in the remaining and high safety and effectiveness profiles. Achievement of ZFL was predicted by the type of arrhythmia, operator's experience, and patient's age.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Fluoroscopia/métodos , Cirurgia Assistida por Computador/métodos , Taquicardia Supraventricular/cirurgia , Feminino , Seguimentos , Humanos , Imageamento Tridimensional , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
18.
Circ J ; 82(4): 974-982, 2018 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-29415917

RESUMO

BACKGROUND: Our aim was to evaluate the clinical outcome of paroxysmal atrial fibrillation (AF) ablation with contact force technology, using an automated lesion tagging system (VISITAGTM module) with strict criteria of catheter stability.Methods and Results:We enrolled 200 consecutive patients who underwent pulmonary vein isolation (PVI) in 11 centers and were followed up for 12 months. The stability setting was within 3 mm for ≥10 s and for ≥15 s in 47% and 53% of patients, respectively. A mean of 67.2±21.9 VISITAGs was acquired. Freedom from atrial tachyarrhythmias at follow-up was 77.5% (155/200), and the contiguity between lesions was associated with a higher chronic success rate (96% vs. 77.1%; log-rank P=0.036). Radiofrequency (RF), fluoroscopy times, and recurrence rates at the 12-month follow-up were significantly lower than in a comparison group of 80 patients without VISITAGTM module (42.7±14.5 vs. 50.9±23.6 min; P=0.032; 11.6±7.8 vs. 18.4±12.8 min; P=0.003 and 22.5% vs. 41.2%; P=0.02). Two major complications (1 cardiac tamponade and 1 minor stroke) were observed only in the control group. CONCLUSIONS: Paroxysmal AF ablation with contact force technology and strict criteria of stability using the VISITAG module was a safe procedure, associated with an improvement in efficiency and a reduction of atrial tachyarrhythmia recurrence at the 12-month follow-up compared with manual annotation. Contiguity between lesions seemed to enhance effectiveness outcomes.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Veias Pulmonares/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Taquicardia/patologia , Taquicardia/prevenção & controle , Resultado do Tratamento , Adulto Jovem
19.
J Atr Fibrillation ; 9(6): 1533, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29250288

RESUMO

BACKGROUND: Cryoablation procedures for pulmonary veins isolation have proved to be a successful treatment of atrial fibrillation, but exposure of surrounding organs to excessively low temperatures is potentially dangerous. Hence the importance of monitoring esophageal temperature and at the same time predicting the thermal field induced by the procedure, so to provide clinicians with a valuable tool to take critical decisions. METHODS AND RESULTS: We formulate a mathematical model for computing the temperature in the relevant region and we use numerical simulations to interpret recorded clinical data. The temperature at the outer esophageal surface can be much lower than the luminal one. Observing the esophageal lumen cooling rate at the early stage of the procedure it is possible to forecast whether temperature is bound to reach dangerous values; the same quantity has a correlation with the steepness of the transesophageal thermal gradient. CONCLUSION: Monitoring the time evolution of luminal esophageal temperature is of fundamental importance not only to realize but also to predict well in advance critical developments of the procedure.

20.
J Atr Fibrillation ; 7(1): 1075, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-27957085

RESUMO

The discrimination between ventricular (VT) and supraventricular tachycardia (SVT) and the evaluation of their hemodynamic impact are essential issues in the arrhythmia management. A new pacing device features a tachycardia diagnostic system relying on simultaneous recording of the transvalvular impedance (TVI) and a special integrated electric signal derived by the whole set of endocardial electrodes (iECG). The iECG waveform is sensitive to the pattern of ventricular activation, similarly to the surface ECG. The TVI increases in systole and decreases in diastole and the amplitude of this cyclic fluctuation is an expression of the effectiveness of the pump function. In order to test the value of these signals in the analysis of a tachycardia, we have assessed the iECG and TVI modifications induced by different SVTs and tolerated and non-tolerated VTs, during electrophysiological (EP) studies. In case of SVT, the ventricular component of the iECG maintained the same morphology as in sinus rhythm. The peak-peak amplitude of the TVI fluctuation was reduced to 66 ± 11 % of the individual sinus rhythm reference, but the signal was present at every beat and showed a remarkable stability (variation coefficient 0.19 ± 0.01). In case of VT, the ventricular component of the iECG was strikingly different than in sinus rhythm. Regular TVI fluctuation was observed with tolerated VTs (peak-peak amplitude 74 ± 6 %; variation coefficient 0.21 ± 0.04). In contrast, with non-tolerated VTs the TVI amplitude was depressed below 40%, and the signal was virtually absent in the event of very fast VT or VF. Our results confirm that the iECG is a reliable tool to quickly discriminate VTs from SVTs and that TVI can provide information on the severity of the hemodynamic impairment produced by a tachycardia, with potential clinical benefit in the follow-up of pacemaker patients. Furthermore, the application of these signals to automatic algorithms of arrhythmia recognition might improve the specificity of therapy administration by an implantable defibrillator (ICD).