Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38771161

RESUMO

BACKGROUND: The aim of this study was to compare mid-term clinical and morphological outcomes in patients undergoing open (OR) and endovascular aortic repair (EVAR) with a proximal wide neck abdominal aortic aneurysm (WN-AAA). METHODS: Between 2009 and 2014 data of all patients undergoing OR at IRCCS San Raffaele Hospital and EVAR at German Aortic Center Hamburg were retrospectively analyzed. Primary endpoints were aneurysm-related mortality at 5 years, reintervention, and overall mortality. Secondary endpoint was proximal neck enlargement. A 1:1 propensity score matching (PSM) was performed. Survival and freedom from AAA-related reintervention were investigated in matched OR and EVAR group by Kaplan-Meier analysis. RESULTS: Of all OR performed at IRCCS San Raffaele Hospital 70 were found to have a proximal neck >28 mm (mean age: 69.8±7.2 years, 67 [95.71%] male); of all consecutive EVAR performed at German Aortic Center Hamburg, 52 required an endograft size of at least 32 mm (mean age of 73.1±8.7 years, 49 [94.2%] male). After PSM, the study cohort consisted of 30 OR and EVAR. One early mortality was registered in both groups (P=NS). Mid-term freedom from reintervention compared in OR and EVAR, with no statistically significant differences (P=0.979). Eight (15.4%) patients treated with EVAR developed a significant proximal diameter enlargement (≥3 mm) while only 1 (1.4%) patient in the OR group had the same evolution (P<0.01). CONCLUSIONS: In WN-AAA neck enlargement is observed more frequently in patients undergoing EVAR, but reintervention rate was similar in the 2 groups, demonstrating that both options were safe and effective.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38705454

RESUMO

OBJECTIVE: This study aimed to report the initial experience with a novel bidirectional double cuff inner branch design for incorporation of renal and mesenteric arteries in patients undergoing fenestrated and branched endovascular aortic repair (F/BEVAR). METHODS: A retrospective review was undertaken of the experience of F/BEVAR with grafts integrating at least one bidirectional double cuffed inner branch implanted at three tertiary aortic centres between March 2022 and June 2023. All consecutive patients were included. Baseline characteristics, operative data, and follow up data were collected. Results were presented as number or median (interquartile range) unless otherwise stated. RESULTS: Thirteen patients (10 male; median age 72 [68, 77] years) had F/BEVAR using a total of 15 bidirectional double cuffed inner branches (30 cuffs). Indications for bidirectional doubled cuffed inner branches included cranial vessel orientation or double renal arteries in four patients each, common coeliomesenteric trunk in three patients, and early renal artery bifurcation, renal artery origin from a false lumen requiring a flexible route for catheterisation, and surplus configuration in one patient each. Twenty three of the 30 cuffs were used, whereas the remaining seven cuffs were intentionally occluded with vascular plugs. Target vessel incorporation was successful in all bidirectional branches. There was one technical failure related to unsuccessful catheterisation of a left renal artery targeted through a unidirectional caudal inner branch. During a median follow up of seven months there were no instances of target vessel instability or re-interventions and two patients died of causes unrelated to the bidirectional branches. CONCLUSION: The results of the use of bidirectional double cuff inner branches are promising, with high technical success and no short term branch related complications in this preliminary experience. This could potentially expand the applicability of branch endografting of complex endovascular aortic repairs, but long term results are still missing.

3.
J Endovasc Ther ; : 15266028241251985, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38708984

RESUMO

PURPOSE: The treatment of thoracoabdominal aortic aneurysms (TAAAs) using branched endovascular aortic repair (BEVAR) is safe and effective. During deployment, the superior mesenteric artery (SMA) branch can unintentionally open into the celiac trunk (CT) ostium and switched catheterization of the SMA from the CT branch and the CT from the SMA branch can be used as an alternative technique in these cases. This study aimed to investigate the outcome of exchanging the intended target vessels (TVs) for the CT and SMA branches during BEVAR. MATERIALS AND METHODS: A single-center retrospective analysis of patients with TAAAs who underwent BEVAR, using off-the-shelf or custom-made devices (CMDs), with an unintended exchange of TVs for the CT and SMA branches was performed. RESULTS: Between 2014 and 2023, 397 patients were treated with BEVAR for TAAA. Eighteen (4.5%) of those patients were treated with an exchange of TVs for the CT and SMA branches. T-branch was used in 9 cases (50%) and the remaining patients were treated with CMDs. Twelve patients were treated electively, 3 were symptomatic and 3 presented with rupture. Of 36 mesenteric TVs in those 18 patients, 34 (94%) were catheterized successfully, including all 18 SMAs and 16 of the 18 CTs. No branch stenosis or occlusion of the switched mesenteric TVs was detected during follow-up. During 30-day follow-up, 3 patients died and during a median follow-up of 3 (interquartile range [IQR]: 1-15) months 3 more patients died. None of the deaths or the 2 unintended reinterventions was induced by the mesenteric TV exchange. The median hospital stay was 14 (IQR: 9-22) days with a median of 4 (IQR: 2-11) days at the intensive care unit. CONCLUSION: The exchange of the mesenteric TVs for the CT and SMA branches during BEVAR with off-the-shelf and CMD endografts is feasible with good TV patency and freedom from TV-related reinterventions. This alternative technique should be considered in selected cases when direct catheterization via the intended branch is deemed more time-consuming or not feasible. CLINICAL IMPACT: This is the first description of using an exchange of target vessels for the celiac trunk and the superior mesenteric artery branches in patients with thoracoabdominal aortic aneurysms undergoing BEVAR, using off-the-shelf or custom-made devices. The high success rate as well as the good clinical results without any branch stenosis or occlusion during follow-up highlight the feasibility of this alternative technique. It could help in challenging cases when catheterization of the intended target vessels is not possible or too time consuming, resulting in higher success rates of BEVAR and better clinical results.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38697255

RESUMO

OBJECTIVE: Fenestrated or branched endovascular repairs (f/bEVAR) are valuable treatments in patients with chronic post-dissection thoraco-abdominal aneurysms (PD-TAAA). This study aimed to analyse early and follow up outcomes of f/bEVAR. DESIGN: Thirty day and follow up outcomes of consecutive patients with PD-TAAA treated with f/bEVAR in a tertiary centre over 8 years were retrospectively analysed. METHODS: All patients presenting with PD-TAAA and managed with f/bEVAR, were eligible. Modified Crawford's classification system was used. Thirty day mortality and major adverse events (MAE) were analysed. Time to event data were estimated with Kaplan-Meier survival analysis. RESULTS: Fifty five patients (80% men, mean age 63.7 ± 7.7 years) were included: 12 (22%) were managed urgently; 25 (46%) for chronic type B aortic dissection; and the remainder for residual type A aortic dissection. Of these patients, 88% had undergone previous thoracic endovascular aortic repair. Prophylactic cerebrospinal fluid drainage (CSFD) was used in 91%. Fifteen (27%) patients were treated with fEVAR, nine (16%) with fenestrations and branches, and 31 (56%) with bEVAR. False lumen adjunctive procedures were used in 56%. Technical success was achieved in 96% of patients. Thirty day mortality was 7% and MAE rate was 20%. Spinal cord injury (SCI) grades 1 - 3 and grade 3 rates were 13% and 2%, respectively. Mean follow up was 33.0 ± 18.4 months. Survival and freedom from unscheduled re-intervention were 86% (SE 5%) and 55% (SE 8%) at 24 months, respectively. Freedom from target vessel stenosis and occlusion was higher in fEVAR at the 12 month follow up (p = .006) compared with bEVAR. CONCLUSION: Fenestrated or branched endovascular repairs in patients with PD-TAAA showed high technical success, with acceptable early mortality and MAE rates. The SCI rate was > 10%, despite CSFD use and staged procedures. Almost one-half of patients needed an unscheduled re-intervention within 24 months after f/bEVAR.

5.
Am J Cardiol ; 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38761964

RESUMO

"Full moon" is a central calcification that occludes the entire vessel on coronary computed tomography angiography (CCTA). We examined the association of "full moon" calcification as identified by CCTA, on clinical and procedural outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI). We studied patients who underwent elective CTO PCI in two European centers and had pre-procedural CCTA. The primary endpoint was the inability to cross the lesion and/or the need for extensive debulking techniques. Secondary endpoints were procedural success, in-hospital cardiac mortality, the need for extensive debulking techniques, myocardial infarction (MI), major adverse cardiac events (MACE, defined as in hospital death, MI and clinically driven target vessel revascularization) and stent thrombosis. Secondary procedural endpoints included procedural time, fluoroscopy time, number of guidewires and balloons, stent length, number and diameter and contrast volume. Multivariable logistic regression analysis was performed identifying potential covariates related to the primary outcome according to knowledge and prior studies. Subsequently, a stepwise selection approach was performed to select factors with the greatest predictive value. Among 140 patients included, 28 (20%) had a "full moon" calcified CTO-plaque. Patients in the full moon group were older and had more cardiovascular risk factors. There was not significant difference in the need for retrograde approach and antegrade dissection and re-entry (ADR) techniques in the "full moon" group vs the other groups (32.1% vs 37.5%, p=0.59 and 0% vs 1.7%, p=0.47 respectively). Compared with patients who did not have full moon morphology, full moon patients had higher incidence of the primary outcome (53.5% vs 12.5%;p<0.001). On multivariable analysis that included chronic kidney failure and prior coronary artery bypass surgery, full moon calcification was associated with higher incidence of the primary endpoint; OR 6.5;95% CI 2.1-20.5;p=0.001). Moreover, lower procedural success (71.4% vs 87.5%;p=0.03), higher incidence of coronary perforations (14.2% vs 3.5%;p<0.02) and higher procedural [172.5 (118.0-237.5) vs 144.0 (108.50-174.75); p=0.02] and fluoroscopic time [62.6 (38.1-83.0) vs 42.8 (29.5-65.7); p=0.03] were observed in the "full moon" group. Overall MACE did not differ between the two groups (1 patient in the "full moon" group vs 1 patient in the no "full moon" group; 3.5% vs 0.8%, p=0.29). In conclusion, "full moon" calcification on CCTA was independently associated with procedural complexity and adverse outcomes in CTO-PCI.

6.
J Endovasc Ther ; : 15266028241245341, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597263

RESUMO

OBJECTIVES: Electrosurgery has been long used in endovascular procedures, with only case reports in the aortic field. Our aim is to present a case series with the use of an electrified wire to perform catheter-based electrosurgery by applying external current through an electrocautery pen. METHODS: Single-center retrospective case series of all patients undergoing complex aortic surgery from October 2020 to August 2023, in whom the electrified wire technique was used: (1) Perforation of a dissection flap or left subclavian artery (LSA) in situ endograft fenestration-a 0.014" polytetrafluoroethylene (PTFE) insulated guidewire is detached from the insulation with a scalpel at the end and a cautery pen is here attached with a clamp. A curved tip catheter or sheath is positioned against the aortic flap or the endograft (through a left brachial access in this case) and the wire pushed, crossing the flap by activating the electrocautery pen and (2) slicing a dissection flap ("powered cheese-wire technique")-after same preparation as above, the middle section of the 0.014 guidewire is removed from the PTFE and bent into a V-shape. Once in the aorta, the guidewire crosses from the true lumen (TL) to the false lumen (FL) and a through-and-through access is obtained. Sheaths are positioned against the flap from both sides and moved up or down while the electricity is activated, slicing the flap and communicating both lumens. Technical success and technical-related complications were evaluated. RESULTS: Eleven cases concerning aortic dissections and 1 case of aortic atresia were treated. Four patients presented urgently, whereas the rest were planned procedures. Seven cases underwent perforation of a dissection flap, 2 cases underwent the powered cheese-wire technique, in 2 cases for an LSA in situ fenestration, and in 1 case to cross an aortic atresia at the aortic isthmus. The technique was in all cases successfully applied. No complications related to the technique occurred. CONCLUSIONS: The "electrified wire" technique is a feasible and ready-available tool that can be safely used in complex aortic interventions, especially to perforate aortic tissue like dissection flaps or to perform in situ fenestrated repairs by perforation of the endograft fabric. CLINICAL IMPACT: The electrified wire technique described herein is a straightforward technique that uses readily available tools to perform electrosurgery. We present its use in complex aortic procedures. However, it could be envisioned for any vascular procedure that requires crossing of the vessel or even prosthetic material. As we have described in this series, when used along with an adequate properative planning, it can be a safe tool of great utility, as has already been demonstarted in the field of the interventional cardiology.

7.
J Vasc Surg ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38580160

RESUMO

OBJECTIVE: Fenestrated and branched thoracic endovascular repair (f/bTEVAR) have been successfully applied in patients with diverse aortic arch pathologies. The aim of this study is to present the early and mid-term outcomes of patients with native proximal aortic landing (NPAL) managed with f/bTEVAR. METHODS: A single-center retrospective analysis of patients with NPAL, managed with f/bTEVAR, between September 1, 2011, and June 30, 2022, was conducted. All patients were treated with custom-made devices (Cook Medical) with landing within Ishimaru zones 0 to 2. Primary outcomes were technical success, mortality, stroke, and retrograde type A dissection at 30 days. Follow-up outcomes were considered secondary. RESULTS: A total of 126 patients were included (69.8% males; mean age, 70.8 ± 4.2 years; 18.3% urgent). The main indications (60.4%) for repair were aortic arch (29.4%) and thoracoabdominal aortic aneurysms (31.0%). Seventy-two patients (57.1%) were managed with fTEVAR. Proximal landing in zone 0 and 1 was chosen in 97.6%. Technical success was 94.4%, and 30-day mortality was 11.9%. Strokes were diagnosed in 13.5% of patients and major strokes were identified in 7.9% cases. Retrograde type A dissection rate was 3.9%. The multivariate analysis confirmed landing in Ishimaru zone 0 as an independently related factor for stroke (P = .005), whereas stroke (P < .001), pericardial effusion (P < .001), and acute kidney injury (P < .001) were independently related to 30-day mortality. Mean follow-up was 17.5 ± 9.3 months. The estimated survival rate and the freedom from reintervention rate were 72.6% (standard error, 4.4%) and 46.4% (standard error, 6.0%) at 24-month follow-up, respectively. CONCLUSIONS: Stroke rate after endovascular arch repair was alarming among patients with NPAL. Proximal landing to zone 0 was related to higher risk of stroke. Reinterventions were common within the 24-month follow-up.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38677467

RESUMO

OBJECTIVE: Female sex is a risk factor for adverse events after endovascular aortic repair. Sex comparative early and mid term outcomes of fenestrated and branched endovascular aortic arch repair (f/b-Arch) are presented. METHODS: Single centre retrospective sex comparative analysis of consecutive patients managed with f/b-Arch according to STROBE. Primary outcomes were sex comparative technical success, mortality, and cerebrovascular morbidity at 30 days. Kaplan-Meier estimates were used for follow up outcomes. RESULTS: Among 209 patients, 38.3% were women. Coronary artery disease (p < .001) and previous myocardial infarction (p = .001) were more common in women. Non- native proximal aortic landing was higher in women (women: 51.3%; men: 31.8%, p = .005) and aortic dissection rate was lower (28.8% vs. 48.1%, p = .005). Proximal landing to Ishimaru zones showed no difference (zone 0: p = .18; zone 1: p = .47; zone 2: p = .39). Graft configurations were equally distributed. In total, 416 supra-aortic trunks were bridged. Median number of revascularisations per patient was 2 (interquartile range 1, 3), with no difference between sexes (p = .54). Technical success (women: 97.5%; men: 96.7%, p = .80), 30 day mortality (women: 10%; men: 9.3%, p = .86), and cerebrovascular morbidity (women: 11.3%; men: 17.1%, p = .25) were similar. Women presented more access related complications (women: 32.5%; men: 16.3%, p = .006), without affecting access related re-interventions (p = .55). Survival (women: 81.1%, 95% confidence interval [CI] 76.3 - 85.9%; men: 79.8%, 95% CI 76.0 - 83.6%) and freedom from re-intervention (women: 56.6%, 95% CI 50.4 - 62.8%); men: 55.3%, 95% CI 50.1 - 60.5%) at 12 months were similar (log rank, p = .40 and p = .41, respectively). CONCLUSION: Both sexes presented similar outcomes after f/b-Arch. Appropriate patient selection may decrease the effect of sex in f/b-Arch outcomes.

9.
Ann Surg ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501239

RESUMO

OBJECTIVE: This study aimed to present the early and mid-term outcomes of fenestrated/branched thoracic endovascular aortic repair (f/bTEVAR) for aortic arch pathologies. BACKGROUND: f/bTEVAR represents a less invasive treatment option for aortic arch diseases. Previous published series showed decreased early mortality and morbidity compared to open repair. METHODS: A single-center retrospective analysis of consecutive patients, managed with f/bTEVAR (Cook Medical, Bloomington, IN, USA) between 01.09.11and 30.06.22 was conducted. Primary outcomes were technical success, 30-day mortality and stroke. Data during follow-up and factors affecting early mortality and stroke were analyzed. RESULTS: 209 patients were included (38.3% females; mean age 69.8±3.4years; mean aortic diameter 61±4.7 mm); 14.4% were managed urgently. Fenestrations/scallop configuration was used in 39.7%, branched devices in 55.5% and branch/scallop combination in 4.8%. Landing to zone 0 was performed in 65.5% and in zone 1 in 32.1%. Non-native aortas were used for landing in 39.2%. Technical success was 97.1% and 30-day mortality 9.5%. Strokes were identified in 10%; 5.7% major. Non-native proximal aortic landing zone was an independent protective factor for stroke (P=0.002). Post-operative stroke (P<0.001) and pericardial effusion (P<0.001) were independently related to 30-day mortality. The mean follow-up was 21±8 months. The estimated survival and freedom from reintervention rates were 79.5% (standard error; SE3.1%) and 47.1% (SE 4.3%) at 24months, respectively. CONCLUSIONS: f/bTEVAR presented high technical success and acceptable 30-day mortality. Non-native proximal landing zone was related to lower stroke rate. Half of patients needed a reintervention within the 24-month follow-up.

10.
J Vasc Surg ; 79(3): 457-468.e2, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38453660

RESUMO

BACKGROUND: Fenestrated and branched endovascular aortic repair (F/BEVAR) of thoracoabdominal aortic aneurysms (TAAAs) has shown high technical success and low early mortality rates. Aneurysm extent has been reported as a factor affecting outcomes. This study aimed to assess the early and midterm follow-up outcomes of patients managed by F/BEVAR for types I through III TAAAs. METHODS: A single-center retrospective analysis was conducted, including data from consecutive, elective and urgent (symptomatic and ruptured cases), patients treated for types I through III TAAAs, between October 1, 2011, and October 1, 2022, using F/BEVAR. Degenerative and postdissection TAAAs were included. Patients received prophylactic cerebrospinal fluid drainage (CSFD), except those under therapeutic anticoagulation, those who were hemodynamically unstable, or those with failed CSFD application. When an initial thoracic endovascular aortic repair was performed, as part of a staged procedure, no CSFD was used. Later stages and nonstaged procedures were performed under CSFD. Thirty-day mortality and major adverse events (MAEs) were analyzed. Kaplan-Meier estimates were used for follow-up outcomes. RESULTS: F/BEVAR for types I through III TAAAs was performed in 209 patients (56.9% males; mean age, 69.6 ± 3.2 years; mean aneurysm diameter, 65.2 ± 6.2 mm); 29.2% type I, 57.9% type II, and 12.9% type III. Urgent repair was performed in 26.7% of patients (56 cases; 23 ruptured and 33 symptomatic cases) and 153 were treated electively. Thirty-two patients (15.3%) were classified as American Society of Anesthesiologists (ASA) class IV. CSFD was used in 91% and staged thoracic endovascular aortic repair was performed in 51.2% of patients. Technical success was 93.8% (96.7% in elective vs 94.6% in urgent cases; P = .92). Thirty-day mortality was 11.0% (4.6% in elective vs 28.5% in urgent cases; P < .001) and MAEs were recorded in 17.2% of cases (7.8% in elective vs 42.8% in urgent cases; P < .001). Spinal cord ischemia rate was 20.5% (17.6% in elective vs 28.7% in urgent cases; P = .08), whereas 2.9% of patients presented paraplegia (1.3% in elective and 7.1% in urgent cases; P = .03). The mean follow-up was 16 ± 5 months. Survival was 75.0% (standard error, 4.0%) and freedom from reintervention was 73.3% (standard error, 4.4%) at 36 months. ASA IV and urgent repair were detected as independent factors related to early mortality and MAE, whereas ruptured aneurysm status was related to spinal cord ischemia evolution. CONCLUSIONS: Endovascular repair for types I through III TAAAs provides encouraging early outcomes in terms of mortality, MAE, and paraplegia, especially in an elective setting. Setting of repair and baseline ASA score should be taken into consideration during decision-making.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Masculino , Humanos , Idoso , Feminino , Correção Endovascular de Aneurisma , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Isquemia do Cordão Espinal/etiologia , Paraplegia/etiologia
11.
Artigo em Inglês | MEDLINE | ID: mdl-38320646

RESUMO

OBJECTIVE: Iliac branch devices (IBDs) have shown good results but there is little evidence for the risk of internal iliac artery (IIA) endoleak, so there are no clear recommendations on the maximum diameter it should be. Based on limited evidence, it was hypothesised that an IIA of ≥ 11 mm in diameter presents an increased risk of type Ic endoleak. METHODS: This was a single centre, retrospective case control study. Patients undergoing an IBD with the main trunk of the IIA as the target vessel, between 2015 and 2021, were identified. Two groups were created: those with a main trunk diameter of < 11 mm; and those with a diameter of ≥ 11 mm. Technical success, freedom from type Ic endoleak, and re-intervention rates were compared. A receiver operating characteristic (ROC) curve was performed to show a cutoff IIA diameter value for risk of type Ic endoleak. Multivariate analysis was performed to assess the risk of type Ic endoleak and the presence of calcification, stenosis, and landing zone length in the IIA. RESULTS: There were 182 IBDs identified. The dilated IIA group (54 IBDs) had significantly lower technical success (91% vs. 98.4%; p = .002), lower freedom from type Ic endoleak (77% vs. 97.1% at 24 months; p = .001), and lower freedom from re-interventions (70% vs. 92.4% at 24 months; p = .002). The ROC curve showed that 10.5 mm was the cutoff diameter for type Ic endoleak. Moderate or severe calcification as well as landing zone length < 5 mm also correlated with type Ic endoleak. CONCLUSION: IBDs have a statistically significantly higher rate of technical failure, lower freedom from type Ic endoleak, and lower freedom from re-intervention when the IIA is ≥ 11 mm in diameter.

12.
Ann Surg ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38323417

RESUMO

OBJECTIVE: To analyze the outcomes of urgent/emergent endovascular aortic repair of patients with free/contained ruptured thoracoabdominal aortic aneurysms (rTAAA). BACKGROUND: Endovascular repair of rTAAA has been scarcely described in emergent setting. METHODS: An international multicenter retrospective observational study (ClinicalTrials.govID:NCT05956873) from January-2015 to January-2023 in 6 European and 1 United States Vascular Surgery Centers. Primary end-points were technical success, 30-day and/or in-hospital mortality and follow-up survival. RESULTS: A total of 100 rTAAA patients were included (75 male; mean age 73 y). All patients (86 contained and 14 free ruptures) were symptomatic and treated within 24-hours from diagnosis: multi-branched off-the-shelf devices (Zenith t-branch,Cook Medical Inc.Bjaeverskov,Denmark) in 88 patients, physician-modified endografts in 8, patient-specific device or parallel grafts in two patients each. Primary technical success was achieved in 89 patients and 30-day and/or in-hospital mortality was 24%. Major adverse events (MAEs) occurred in 34% of patients (permanent dialysis and paraplegia in 4 and 8 patients, respectively). No statistical differences were detected in mortality rates between free and contained ruptured patients (43%vs.21%; P =0.075). Multivariate analysis revealed contained rupture favoring technical success (Odd-Ratio10.1;95%Confidence-Interval:3.0-33.6; P =<0.001). MAEs (OR9.4;95%C-I:2.8-30.5; P =<0.001) and pulmonary complications (OR11.3;95%CI:3.0-41.5; P =<0.001) were independent risk factors for 30-day and/or in-hospital mortality. Median follow-up time was 13 months (interquartile range 5-24); 1-year survival rate was 65%. Aneurysm diameter>80 mm (Hazard-Ratio:2.0;95%CI:1.0-30.5; P =0.037), technical failure (HR:2.6;95%CI:1.1-6.5; P =0.045) and pulmonary complications (HR:3.0;95%CI:1.2-7.9; P =0.021) were independent risk factors for follow-up mortality. CONCLUSION: Endovascular repair of rTAAA shows high technical success; the presence of free rupture alone appear not to correlate with early mortality. Effective prevention/management of post-operative complications is crucial for survival.

13.
J Endovasc Ther ; : 15266028241231905, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38380515

RESUMO

INTRODUCTION: Data on target vessel (TV)-related outcomes in patients managed with branched thoracic endovascular aortic repair (BTEVAR) are limited. This study aimed to present the TV-related outcomes of BTEVAR in patients managed for aortic arch pathologies at 30 days and during follow-up. METHODS: A retrospective analysis of consecutive patients, managed between September 1, 2011, and June 30, 2022, with custom-made aortic arch endografts (Cook Medical, Bloomington, IN, USA), presenting at least one branch configuration, were eligible. Primary outcomes were technical success, TV-related patency, and reinterventions at 30 days. RESULTS: In total, 255 TVs were revascularized using branches: 107 innominate arteries (IAs), 108 left common carotid arteries (LCCAs), and 40 left subclavian arteries (LSAs). Covered stents were used as bridging stents of which 10.2% were balloon expandable. Relining, using bare-metal stents (BMS), was performed in 14.0% of IAs, 35.2% of LCCAs, and 22.5% of LSAs. Technical success on case basis was 99.2%; no failure was related to unsuccessful TV bridging. At 30 day follow-up, no TV occlusion was detected. In 5.6% of cases, a type Ic or III endoleak, attributed to TVs, was recorded. Two patients needed early branch-related reintervention. The mean follow-up was 18.3±9.2 months. Freedom from TV instability was 94.6% (standard error [SE] 2.5%] at 12 months. No TV stenosis or occlusion was detected up to 48 months of follow-up. Freedom from TV-related reinterventions was 95.4% [SE 2.4%] at 12 months. CONCLUSION: TV stenosis or occlusion in BTEVAR cases is rare and TV-related reinterventions and instability events are mainly attributed to type Ic and III endoleak formation. CLINICAL IMPACT: Previous studies focusing on target vessel (TV) outcomes after endovascular aortic arch repair are limited. In this study, including 255 TVs revascularized using branched arch devices, bridging was performed with covered stents, of which 90% were self-expanding. Relining was at the discretion of the operator and was 14% for the innominate, 35.2% for the left common carotid and 22.5% for the left subclavian artery branches. No 30-day occlusion was detected. The freedom from TV instability was almost 95% at 12 months. TV instability and reintervention were mainly attributed to endoleaks type Ic and IIIc.

14.
Eur J Clin Invest ; 54(5): e14166, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38269600

RESUMO

BACKGROUND: Embolization of debris can complicate transcatheter aortic valve implantation (TAVI) causing stroke. Cerebral embolism protection (CEP) devices can divert or trap debris. PURPOSE: To evaluate the efficacy of CEP during TAVI vs the standard procedure. DATA SOURCES: PubMed, SCOPUS and DOAJ 1/01/2014-04/12/2023. STUDY SELECTION: Randomized and observational studies comparing CEP versus standard TAVI, according to PRISMA. PRIMARY OUTCOME: stroke. SECONDARY OUTCOMES: death, bleeding, vascular access complications, acute kidney injury and infarct area. DATA EXTRACTION: Two investigators independently assessed study quality and extracted data. DATA SYNTHESIS: Twenty-six articles were included (540.247 patients). The primary endpoint was significantly lower (RR = 0.800 95%CI:0.682-0.940; p = 0.007) with CEP. Similarly, death rates were significantly lower with CEP (RR = 0.610 95%CI:0.482-0.771; p < 0.001). No difference was found for bleeding (RR = 1.053 95%CI:0.793-1.398; p = 0.721), vascular complications (RR = 0.937 95%CI:0.820-1.070; p = 0.334) or AKI (RR = 0.982 95%CI:0.754-1.279; p = 0.891). CONCLUSIONS: Use of CEP during TAVI is associated with improved outcomes. Future studies will identify patients who benefit most from CEP.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Observacionais como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
15.
JACC Case Rep ; 29(1): 102152, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38223260

RESUMO

An 80-year-old post-coronary artery bypass graft (CABG) patient had an acute coronary syndrome with non-ST-segment elevation myocardial infarction (ACS-NSTE) with saphenous vein graft (SVG)-obtuse marginal stenosis. High-definition intravascular ultrasound revealed an underexpanded SVG stent with a hyperechoic structure. Optical coherence tomography confirmed surgical clip causing compression, resolved by post-dilation. This case underscores ACS-NSTE complexity post-CABG and the critical role of coronary imaging in optimizing interventions by addressing surgical clip-induced compression.

16.
Rofo ; 196(1): 52-61, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37699431

RESUMO

BACKGROUND: An abdominal aortic aneurysm (AAA) is defined as a localized dilatation of the abdominal aorta of ≥ 3 cm. With a prevalence of 4-8 %, AAA is one of the most common vascular diseases in Western society. Radiological imaging is an elementary component in the diagnosis, monitoring, and treatment planning of AAA patients. METHOD: This is a narrative review article on preoperative imaging strategies of AAA, incorporating expert opinions based on the current literature and standard-of-care practices from our own center. Examples are provided to illustrate clinical cases from our institution. RESULTS AND CONCLUSION: Radiological imaging plays a pivotal role in the initial diagnosis and monitoring of patients with AAA. Ultrasound is the mainstay imaging modality for AAA screening and surveillance. Contrast-enhanced CT angiography is currently considered the gold standard for preoperative imaging and image-based treatment planning in AAA repair. New non-contrast MR angiography techniques are robustly applicable and allow precise determination of aortic diameters, which is of critical importance, particularly with regard to current diameter-based surgical treatment guidelines. 3D imaging with multiplanar reformation and automatic centerline positioning enables more accurate assessment of the maximum aortic diameter. Modern imaging techniques such as 4D flow MRI have the potential to further improve individualized risk stratification in patients with AAA. KEY POINTS: · Ultrasound is the mainstay imaging modality for AAA screening and monitoring. · Contrast-enhanced CT angiography is the gold standard for preoperative imaging in AAA repair. · Non-contrast MR angiography allows for accurate monitoring of aortic diameters in AAA patients. · Measurement of aortic diameters is more accurate with 3D-CT/MRI compared to ultrasound. · Research seeks new quantitative imaging biomarkers for AAA risk stratification, e. g., using 4D flow MRI.


Assuntos
Aneurisma da Aorta Abdominal , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aorta Abdominal/diagnóstico por imagem , Ultrassonografia/métodos , Angiografia por Tomografia Computadorizada , Imageamento por Ressonância Magnética
17.
Int J Cardiol ; 395: 131572, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37913960

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) showed safety and efficacy in patients with severe aortic stenosis. Commissural alignment (CA) during TAVR has the potential to reduce the impact of the prostheses on accessibility of coronary arteries, as misalignment of the neocommissures could cause partial overlap with coronary ostia. Therefore, the aim of this study was to investigate the impact of CA on coronary overlap rates. METHODS: We examined the techniques of CA and their impact on coronary access. Eligible studies were searched for on Pubmed, SCOPUS and DOAJ and selected using PRISMA guidelines. The primary endpoint was the incidence of a severe coronary overlap or failed coronary re-access. Results of the analysis are expressed as Risk Ratio (RR) with 95% CI. RESULTS: Four studies were included in this analysis. In these, 681 patients underwent TAVR with CA and 210 underwent TAVR without CA. We examined Evolut valves and Acurate Neo valves. The primary endpoint occurred in 138 patients undergoing TAVR with CA and in 154 patients without CA (RR = 0.279; 95% CI 0.201-0.386; p < 0.001). Neither prosthesis-related, nor patient-related factors had a significant interaction with the measured effect. CONCLUSIONS: Commissural alignment was associated with significantly lower rates of commissure-to-coronary ostia overlap and failure of coronary access. Consequently, a modified insertion technique could reduce coronary overlap and coronary occlusion, particularly in supra-annular valves. Therefore, controlled orientation of prostheses by CA during TAVR could favour coronary access, especially in younger patients that could require coronary re-access after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Resultado do Tratamento , Fatores de Risco
18.
Hellenic J Cardiol ; 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37949356

RESUMO

OBJECTIVE: To provide a quantitative comparison between myocardial revascularization (REVASC) and optimal medical treatment (OMT) alone in patients with chronic coronary syndrome (CCS). METHODS: Pertinent studies were searched for in PubMed/Medline until 12/03/2023. Randomized controlled trials that compare REVASC to OMT reporting clinical outcomes were selected according to PRISMA guidelines. The primary outcome was cardiovascular death. Two investigators independently assessed the study quality and extracted data. RESULTS: Twenty-eight randomized controlled studies (RCTs) including 20692 patients were included in this meta-analysis. The rate of cardiovascular mortality was significantly lower among patients treated with myocardial revascularization [risk ratio (RR) 0.79, 95% CI 0.69-0.90]. Age (p = 0.03), multivessel disease (p < 0.001), and follow-up duration (p = 0.001) were significant moderators of CV mortality. Subgroup analyses showed a larger benefit in patients treated with drug-eluting stents and those without chronic total occlusion. Among secondary outcomes, myocardial infarction was less frequent in the REVASC group (RR = 0.74; p < 0.001), while no significant difference was found for all-cause mortality (p = 0.09) nor stroke (p = 0.26). CONCLUSIONS: The present analysis showed lower rates of CV mortality and myocardial infarction in CCS patients treated with myocardial revascularization compared to OMT. This benefit was larger with increasing follow-up duration. Personalized treatment based on patient characteristics and lesion complexity may optimize clinical outcomes in patients with CCS.

19.
J Vasc Surg Cases Innov Tech ; 9(4): 101343, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37965110

RESUMO

We describe the feasibility of covered endovascular reconstruction of the aortic bifurcation (CERAB) through a single femoral access and a steerable sheath. We present the technique, which we used for a patient with severe aortoiliac calcification and bilateral involvement of the common femoral artery. The patient underwent endarterectomy of the left common femoral artery plus CERAB with an aortic stent graft and bilateral covered stents for the common iliac artery with kissing dilatation with a steerable sheath using only left femoral access. CERAB can be performed using unilateral access with the aid of a steerable sheath, reducing the potential for access site complications.

20.
J Endovasc Ther ; : 15266028231206996, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37872769

RESUMO

PURPOSE: For aortic coarctation in adults endovascular repair is the treatment of choice with an acceptable safety profile. Aortic isthmus atresia is a related condition with a complete occlusion of the aorta not allowing catheterization across the isthmus. This technical note describes a recanalization of an aortic isthmus atresia using radiofrequency with an "electrified wire technique." TECHNIQUE: A guidewire was selectively denuded of PTFE (polytetrafluoroethylene) at the distal end and was placed through a catheter distal to the aortic isthmus atresia. The denuded end of the wire was clamped to an electrosurgery pencil. By pushing the wire toward a tulip-snare, which was placed as a target proximal of the occlusion via left trans-brachial access, and shortly activating of the electrosurgery pencil the electrified wire recanalized the occlusion and was snared and used to guide implantation of a balloon-expandable covered stent. CONCLUSION: The electrified wire puncture technique can be used to recanalize adult aortic isthmus atresia after failed conventional attempts. CLINICAL IMPACT: The electrified wire technique offers an off-the shelf option to modify standard guidewires for the use with radiofrequency to cross a complete aortic isthmus occlusion after failed conventional attempts. This new technique may be applied also in other situations like dissection flap fenestration, transcaval access and similar.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...