Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin J Am Soc Nephrol ; 5(11): 2004-17, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20813858

RESUMO

BACKGROUND AND OBJECTIVES: Risk analysis for medical devices is a crucial process to grant adequate levels of safety. Identification of device exposure-related hazards is one of the main objectives. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Hazard analysis for hemodialysis devices has been performed by a multidisciplinary team involving engineers and clinical experts. A potential harm list was identified from clinical and technical experience, postproduction information, and literature. Various hazardous situations (circumstances when the use of the dialysis device may lead to described harms) were described. Such hazardous situations were correlated to the extent of the deviation of a specific device parameter from expected ranges. The clinical severity that was relevant to any specific harm was categorized for each hazardous situation using a descriptive and numerical scale with five levels (from negligible [i.e., discomfort only] to catastrophic [i.e., potentially lethal]). RESULTS: Harms in which the deviation of a parameter strictly coincides with the clinically measured effect on the patient are defined as "direct." Otherwise, when another clinical parameter must be involved to quantify severity, the related harm is considered "indirect." Two complete examples of multidisciplinary evaluation for severity of hazards (MESH) are given for a direct harm (air embolism) and for an indirect harm (hypothermia). For other harms, the maximum value of severity involved is provided. CONCLUSIONS: MESH represents a possible example of risk management for dialysis equipment in which, although the manufacturer is directly responsible, a multidisciplinary task force may contribute to a better link between engineering and clinical perspectives.


Assuntos
Embolia Aérea/etiologia , Hipotermia/etiologia , Diálise Renal/efeitos adversos , Diálise Renal/instrumentação , Doença Catastrófica , Estado Terminal , Embolia Aérea/prevenção & controle , Desenho de Equipamento , Falha de Equipamento , Segurança de Equipamentos , Humanos , Hipotermia/prevenção & controle , Comunicação Interdisciplinar , Diálise Renal/mortalidade , Medição de Risco , Fatores de Risco , Gestão da Segurança , Terminologia como Assunto
2.
Curr Opin Crit Care ; 8(6): 544-8, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12454539

RESUMO

The careful application of information technology to the field of acute dialysis may result in both a better understanding of the disease as well as an improvement in patient outcomes. Often these applications increase costs and complexity with little change in understanding or quality of care. To avoid this common trap, a targeted assessment of needs and possible solutions is mandatory. Our group was assembled to provide balanced perspectives and recommendations that address how information technology should be assessed and applied to acute dialysis therapy, with the intent to increase the understanding of the current practice and to improve patient care. To achieve these goals, five areas of focus were identified: patient safety, current practice pattern assessment, practice variation, patient assessment, and dialysis machine technology. To facilitate the assessment, we formulated five specific questions and developed answers based on the available literature and group consensus.


Assuntos
Injúria Renal Aguda/terapia , Sistemas de Apoio a Decisões Clínicas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Diálise Renal/normas , Humanos , Erros Médicos/prevenção & controle , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...