Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36772626

RESUMO

The focus of this study is to design a backlit vision instrument capable of measuring surface roughness and to discuss its metrological performance compared to traditional measurement instruments. The instrument is a non-contact high-magnification imaging system characterized by short inspection time which opens the perspective of in-line implementation. We combined the use of the modulation transfer function to evaluate the imaging conditions of an electrically tunable lens to obtain an optimally focused image. We prepared a set of turned steel samples with different roughness in the range Ra 2.4 µm to 15.1 µm. The layout of the instrument is presented, including a discussion on how optimal imaging conditions were obtained. The paper describes the comparison performed on measurements collected with the vision system designed in this work and state-of-the-art instruments. A comparison of the results of the backlit system depends on the values of surface roughness considered; while at larger values of roughness the offset increases, the results are compatible with the ones of the stylus at lower values of roughness. In fact, the error bands are superimposed by at least 58% based on the cases analyzed.

2.
Artigo em Inglês | MEDLINE | ID: mdl-33557403

RESUMO

The first wave of the COVID-19 pandemic brought about a broader use of masks by both professionals and the general population. This resulted in a severe worldwide shortage of devices and the need to increase import and activate production of safe and effective surgical masks at the national level. In order to support the demand for testing surgical masks in the Italian context, Universities provided their contribution by setting up laboratories for testing mask performance before releasing products into the national market. This paper reports the effort of seven Italian university laboratories who set up facilities for testing face masks during the emergency period of the COVID-19 pandemic. Measurement set-ups were built, adapting the methods specified in the EN 14683:2019+AC. Data on differential pressure (DP) and bacterial filtration efficiency (BFE) of 120 masks, including different materials and designs, were collected over three months. More than 60% of the masks satisfied requirements for DP and BFE set by the standard. Masks made of nonwoven polypropylene with at least three layers (spunbonded-meltblown-spunbonded) showed the best results, ensuring both good breathability and high filtration efficiency. The majority of the masks created with alternative materials and designs did not comply with both standard requirements, resulting in suitability only as community masks. The effective partnering between universities and industries to meet a public need in an emergency context represented a fruitful example of the so-called university "third-mission".


Assuntos
COVID-19/prevenção & controle , Laboratórios , Máscaras/normas , Pandemias , Humanos , Itália
3.
Sensors (Basel) ; 20(11)2020 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-32531962

RESUMO

This paper presents the design and the characterization of a portable laser triangulation measurement system for measuring gap and flush in the car body assembly process. Targeting Human in the Loop (HILT) operations in the manufacturing sector, and in line with the vision of human empowerment with Industry 4.0 technologies, the instrument embeds features to ease operators' activity and compensate possible misuse that could affect the robustness and the quality of data acquired. The device is based on a smartphone integrated with a miniaturized laser triangulation system installed in a cover. The device embodies additional sensors and control systems in order to guarantee operators' safety (switching on and off the laser line based on specific conditions), support operators during the measurement execution task, and optimize the image acquisition process for minimizing the uncertainty associated to the measurement. The smartphone performs on-board processing and allows Wi-Fi communication with the plant IT infrastructure. Compliance to Industry 4.0 requirements is guaranteed using OPC-UA (Open Platform Communications-Unified Architecture) communication protocol enabling the exchange of live data with the plant middleware. The smartphone provides also an advanced high-resolution color display and well proven and ergonomic human-machine interfaces, which have been fully exploited in the design. The paper introduces the system optical layout and then presents the algorithms implemented to realize the gap and flush measurement. The paper finally presents the calibration of the instrument and estimates its calibration uncertainty in laboratory conditions. Then it discusses how performance decays when the operator handles the instrument on a reference car body. Finally, it shows the analysis of uncertainty when the device is used on real car bodies of different colors in a production line. It is observed that the measurement uncertainty of the whole measurement chain (measurand + instrument + operator + uncontrolled environmental conditions) is larger than the instrument calibration uncertainty because the measurement process is affected by the operator and the variable conditions of the production line.

4.
Appl Opt ; 57(4): 730-737, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29400740

RESUMO

The tetragonal PbWO4 (PWO) is one of the most important scintillating crystals, being used both in the Compact Muon Solenoid (CMS) experiment at the European Organization for Nuclear Research (CERN) and in the PANDA project at the Facility for Antiproton and Ion Research (FAIR). Light yield and other relevant scintillation properties depend, among many factors, also on the crystal mechanical quality. Accordingly, a detailed knowledge of crystal piezo-optic properties is a mandatory step toward understanding elasto-optic behavior and performing crystal quality control. In this paper, we evaluate for the first time, to the best of our knowledge, by means of both photoelastic and x-ray measurements, some components of the piezo-optic tensor; moreover, when the crystal is acted upon by a uniaxial stress, we obtain an evaluation for the rotation angle of the optic plane under stress as well as the photoelastic constant. These parameters are necessary to detect the residual stresses within the crystal, if any, and to give an overall quality measure. Such a methodology is in general suitable for any tetragonal crystals.

5.
Ultrasonics ; 81: 39-49, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28577414

RESUMO

The paper presents a technique to measure the speed of sound in fuels based on pulse-echo ultrasound. The method is applied inside the test chamber of a Zeuch-type instrument used for indirect measurement of the injection rate (Mexus). The paper outlines the pulse-echo method, considering probe installation, ultrasound beam propagation inside the test chamber, typical signals obtained, as well as different processing algorithms. The method is validated in static conditions by comparing the experimental results to the NIST database both for water and n-Heptane. The ultrasonic system is synchronized to the injector so that time resolved samples of speed of sound can be successfully acquired during a series of injections. Results at different operating conditions in n-Heptane are shown. An uncertainty analysis supports the analysis of results and allows to validate the method. Experimental results show that the speed of sound variation during an injection event is less than 1%, so the Mexus model assumption to consider it constant during the injection is valid.

6.
Hum Pathol ; 45(4): 745-52, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24565208

RESUMO

The aim of the study was to identify subtle changes in the so-called architectural predominant order in nonrecurrent and recurrent papillary urothelial neoplasm of low malignant potential (PUNLMP). Quantitative analysis was performed with a software package written in LabVIEW (National Instruments, Austin, TX) in DAXX-immunostained tissue sections. Twelve cases of PUNLMP with papillary fronds sectioned lengthwise through the core were investigated and subdivided as follows: 7 nonrecurrent and 5 recurrent PUNLMP cases. Six cases of normal urothelium (NU) were included. When an epithelial thickness threshold is set at 108 µm (ie, 400 pixels), there is a complete separation between NU and PUNLMP; however, nonrecurrent and recurrent cases fall in the same range of thickness. In setting a nuclear elongation factor threshold at 2.1, there are differences between the 2 PUNLMP groups, recurrent PUNLMP and NU cases, showing a somewhat similar proportion of elongated nuclei. The nuclear orientation separates nonrecurrent from recurrent PUNLMP groups; however, NU cases do not appear as a separate group from the 2 PUNLMP groups. In combining epithelial thickness, nuclear elongation, and orientation in a multivariate analysis, the 2 PUNLMP groups appear separate between them and from NU. NU is less thickened than the 2 PUNLMP groups and shows a combination of elongated and less elongated nuclei. Elongated nuclei are more numerous in nonrecurrent PUNLMP, whereas the nuclei in recurrent PUNLMP are less elongated and less polarized than in the other group. Such finding can be used routinely to identify those PUNLMP patients who will have recurrence.


Assuntos
Carcinoma Papilar/patologia , Interpretação de Imagem Assistida por Computador/métodos , Recidiva Local de Neoplasia/patologia , Neoplasias da Bexiga Urinária/patologia , Humanos , Imuno-Histoquímica
7.
Diagn Pathol ; 8: 111, 2013 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-23819605

RESUMO

BACKGROUND/AIMS: The chromatin remodeler DAXX, a predominantly nuclear protein, regulates the status of chromatin organization. The aim of this exploratory immunohistochemical study was to evaluate DAXX protein expression in high grade invasive urothelial carcinoma (UC) of the bladder as a biological regulator of aggressiveness. METHODS: Quantitative analysis was made on DAXX immunostained nuclei in tissue sections from 5 cases of bladder normal urothelium (NU) and 5 cases of bladder pT1 UC. Carcinoma in situ (CIS) and high grade papillary carcinoma (HGPCa) were identified in 2 out of 5 UC cases. RESULTS: The nuclei in UC show an open configuration of the chromatin composed of granules varying in size and distribution and a mean nuclear area 1.7 times greater than that in NU (UC: mean and SD 24.4 ± 11.4 square microns; NU: 14.8 6.5 square microns. The differences are statistically significant). 70% of the NU nuclei are immunostained, whereas 90% of UC nuclei are positive. The mean gray level value in UC, related to the intensity of nuclear immunostaining, is lower than in NU by a factor of 0.94 (UC: mean and SD 100 ± 15; NU: 106 ± 15. The differences are statistically significant). In particular, the value in the nuclei adjacent to the stroma in UC is slightly lower than in the intermediate cell layers by factor of 0.98, whereas in NU it is slightly greater by a factor 1.02 and 1.04 compared to the intermediate and superficial cell layers. The values in CIS and HGPCa are similar to those in UC. CONCLUSIONS: The quantitative immunohistochemical analysis shows an altered protein expression of chromatin remodeler DAXX in UC and in its preinvasive phases, when compared to NU. DAXX evaluation, if associated with markers related to global DNA methylation and histone acetylation, could be used in clinical practice as a marker of aggressiveness. VIRTUAL SLIDES: The virtual slides for this article can be found here:http://www.diagnosticpathology.diagnomx.eu/vs/1398457297102379.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/análise , Biomarcadores Tumorais/análise , Carcinoma in Situ/química , Carcinoma Papilar/química , Montagem e Desmontagem da Cromatina , Imuno-Histoquímica , Proteínas Nucleares/análise , Neoplasias da Bexiga Urinária/química , Urotélio/química , Carcinoma in Situ/patologia , Carcinoma Papilar/patologia , Núcleo Celular/química , Núcleo Celular/patologia , Tamanho do Núcleo Celular , Proteínas Correpressoras , Humanos , Chaperonas Moleculares , Gradação de Tumores , Invasividade Neoplásica , Valor Preditivo dos Testes , Neoplasias da Bexiga Urinária/patologia , Urotélio/patologia
8.
Int Arch Occup Environ Health ; 81(1): 31-40, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17410375

RESUMO

OBJECTIVES: Grip and push forces required for the use of vibrating tools are considered important influencing inputs for the assessment of hand-vibration transmissibility (TR). At present TR measurements are usually referred to the palm of the hand The aims of the present paper are: to present an original measurement procedure for non-contact assessment of the transmissibility of fingers; to report TR data measured on six points of the hand of nine subjects; to correlate TR with: grip, push, hand volume and BMI. METHODS: Tests have been carried out using a cylindrical handle mounted on an shaker. A laser Doppler vibrometer is used to measure the vibration velocity. Push force is measured using a force platform, whereas grip force is measured using a capacitive pressure sensor matrix wrapped around the handle. Tests have been conducted on nine healthy subjects. Proximal and distal regions of the second, fourth and fifth fingers have been investigated. Tests were carried out using a push force of: 25, 50 and 75 N. The excitation signal was a broadband random vibration in the band 16-400 Hz with un-weighted rms acceleration level of 6 m/s(2). RESULTS: Results show how in general TR values measured on distal points are higher respect to the proximal points. A resonance peak is present for all the measured points in the band 55-80 Hz. ANOVA analysis showed that TR is not significantly dependent on: BMI, hand volume and push force alone. While TR is significantly dependent on: grip force alone, measurement positions and grip and push force together. CONCLUSIONS: The proposed procedure shows the advantage to allow local vibration measurement directly on the fingers without the necessity to apply any contact sensor. Results demonstrate how the transmissibility is significantly different on the point where the acceleration is measured.


Assuntos
Mãos/fisiologia , Vibração , Adulto , Índice de Massa Corporal , Força da Mão , Humanos , Masculino , Exposição Ocupacional , Ultrassonografia Doppler
9.
J Occup Health ; 46(4): 253-9, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15308823

RESUMO

The haemodynamic effects, in terms of grip force and hand-transmitted accelerations, produced on the fingers of 10 healthy subjects by operation of a hydraulic breaker held with a low or a high grip were investigated with a new experimental set-up. A novel apparatus consisting of a capacitive sensor matrix and a laser Doppler vibrometer was used to measure the two parameters during breaker operation. Finger blood flow in basal conditions and after each test was evaluated in the four long fingers of both hands with a photoplethysmograph and superficial skin thermometry. The amplitude of the accelerations transmitted to the hand surface was greater during the test with the low grip. Photoplethysmographic and thermometric values were significantly lower than basal values after either test. The amplitude of photoplethysmographic values during the tests was significantly lower with the low than with the high grip in 6 subjects, in both index fingers, and in the right middle finger. The authors show that the level of grip force used for holding the breaker causes transmission of vibrations of wider amplitude, resulting in greater reduction in finger blood flow. In line with the literature, stimulus magnitude, frequency and duration affected finger blood flow, especially in the index finger.


Assuntos
Dedos/irrigação sanguínea , Força da Mão/fisiologia , Vasoconstrição/fisiologia , Vibração , Adulto , Humanos , Masculino , Pletismografia , Fluxo Sanguíneo Regional , Temperatura Cutânea
10.
Artif Organs ; 20(5): 546-552, 1996 May.
Artigo em Inglês | MEDLINE | ID: mdl-28868717

RESUMO

A laser Doppler anemometer (LDA) was used to obtain the mean velocity and the Reynolds stress fields in the inner channels of a well-known centrifugal vaneless pump (Bio-pump). Effects of the excessive flow resistance against which an occlusive pump operates in some surgical situations, such as cardiopulmonary bypass, are illustrated. The velocity vector field obtained from LDA measurements reveals that the constraint-forced vortex provides pumping action in a restricted area in the core of the pump. In such situations, recirculating zones dominate the flow and consequently increase the damage to blood cells and raise the risk of thrombus formation in the device. Reynolds normal and shear stress fields were obtained in the entry flow for the channel formed by two rotating cones to illustrate the effects of flow disturbances on the potential for blood cell damage.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...