Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anesth Analg ; 114(1): 193-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21965374

RESUMO

BACKGROUND: Dexmedetomidine (DEX) affects heart rate (HR), mean arterial blood pressure, cardiac index (CI), stroke index (SI), and systemic vascular resistance index (SVRI) in adults. In this study we sought to determine whether similar effects occur in children undergoing DEX sedation. METHODS: Hemodynamic changes in children were followed during IV DEX sedation for radiological procedures. One group of 8 patients (DEX-brief) received a bolus (2 mcg/kg bolus over 10 minutes) and completed the procedure within 10 minutes. The second group of 9 patients (DEX-prolong) received the bolus plus additional DEX as needed to maintain sedation for procedures lasting longer than 10 minutes (additional 1 mcg/kg/hr infusion with second bolus if needed). CI, SI, and SVRI were measured using a continuous noninvasive cardiac output monitor. Changes in hemodynamic variables at minutes 10, 20, and discharge (time at which patient achieved Aldrete Score ≥9) were compared to baseline by repeated measures ANOVA with effect sizes reported as mean [95% confidence interval]. RESULTS: Data were obtained during 8 DEX-brief and 9 DEX-prolong procedures. In DEX-brief, HR and CI decreased (18.9 [2.3 to 35.5] bpm and 0.74 [0.15 to 1.33] L/min/m(2); respectively) at T1. There was no change in any other hemodynamic variables and all hemodynamic variables returned to baseline at recovery. In DEX-prolong, both HR and CI remained decreased (24.0 [8.3 to 39.6] bpm, 1.51 [0.95 to 2.06] L/min/m(2); respectively) at recovery. In addition, SI was decreased (8.01 [1.71 to 14.31] mL/m(2)) and SVRI was increased (776.0 [271.9 to 1280.4] dynes-sec/cm(5)/m(2)) at recovery in the DEX-prolong group. There were no significant changes in mean arterial blood pressure in either group. CONCLUSION: DEX decreases CI in children and has a cumulative effect. For patients undergoing prolonged procedures HR and CI remained decreased at the time of discharge together with a decrease in SI and an increase in SVRI.


Assuntos
Sistema Cardiovascular/efeitos dos fármacos , Sedação Consciente , Dexmedetomidina/administração & dosagem , Hemodinâmica/efeitos dos fármacos , Hipnóticos e Sedativos/administração & dosagem , Fatores Etários , Análise de Variância , Pressão Sanguínea/efeitos dos fármacos , Boston , Débito Cardíaco/efeitos dos fármacos , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Sedação Consciente/efeitos adversos , Dexmedetomidina/efeitos adversos , Desenho de Equipamento , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Hipnóticos e Sedativos/efeitos adversos , Lactente , Masculino , Monitorização Fisiológica/instrumentação , Estudos Prospectivos , Fatores de Tempo , Tomografia Computadorizada de Emissão , Tomografia Computadorizada por Raios X , Resistência Vascular/efeitos dos fármacos
2.
J Diabetes Sci Technol ; 5(1): 93-8, 2011 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21303630

RESUMO

BACKGROUND: Standard care for infants on extracorporeal life support (ECLS) relies on intermittent measurement of blood glucose (BG); however, this can lead to significant changes in BG that go unrecognized for several hours. The present study was designed to assess performance and clinical applicability of a subcutaneous glucose sensor technology modified for use as a blood-contacting sensor within the ECLS circuit. METHODS: Twelve children, aged 3 years or less, requiring ECLS support were studied. Three continuous glucose sensors (Medtronic MiniMed) were inserted into hubs placed in line with the ECLS circuit. Blood glucose was assessed with a laboratory analyzer (BG(LAB); Bayer Rapidlab 860) approximately every 5 h (mean 4.9 ± 3.3 h) with more frequent samples obtained with a bedside monitor (HemoCue) as needed. Sensor current (I(SIG)) was transmitted to a laptop computer and retrospectively calibrated using BGLAB. Sensor performance was assessed by mean absolute relative difference (MARD), linear regression slope and intercept, and correlation, all with BGLAB as reference. RESULTS: The BGLAB averaged 107.6 ± 36.4 mg/dl (mean ± standard deviation) ranging from 58 to 366 mg/dl. The MARD was 11.4%, with linear regression slope (0.86 ± 0.030) and intercept (9.0 ± 3.2 mg/dl) different from 1 and 0, respectively (p < .05), and correlation (r² = 0.76; p < .001). The system was not associated with any adverse events, and placement and removal into the hubs was easily accomplished. Instances in which more frequent BG values were obtained using a bedside HemoCue (BGHEMO) monitor showed the sensor to respond rapidly to changes. CONCLUSIONS: We conclude that continuous sensors can be adapted for use in an ECLS circuit with accuracy similar to or better than that achieved with the subcutaneous site. Continuous glucose monitoring in this population can rapidly detect changes in BG that would not otherwise be observed. Further studies will be needed to assess the benefit of continuous glucose monitoring in this population.


Assuntos
Técnicas Biossensoriais/estatística & dados numéricos , Glicemia/análise , Circulação Extracorpórea , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/normas , Automonitorização da Glicemia , Calibragem , Pré-Escolar , Circulação Extracorpórea/instrumentação , Circulação Extracorpórea/métodos , Circulação Extracorpórea/normas , Feminino , Cardiopatias Congênitas/sangue , Cardiopatias Congênitas/terapia , Hérnia Diafragmática/sangue , Hérnia Diafragmática/terapia , Hérnias Diafragmáticas Congênitas , Humanos , Lactente , Recém-Nascido , Doenças do Recém-Nascido/sangue , Doenças do Recém-Nascido/terapia , Masculino , Monitorização Fisiológica/normas , Insuficiência Respiratória/sangue , Insuficiência Respiratória/congênito , Insuficiência Respiratória/terapia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...