Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
3.
Int J Hyperthermia ; 36(1): 170-185, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30777497

RESUMO

BACKGROUND: Temperature distributions resulting from hyperthermia treatment of patients with high-risk soft-tissue sarcoma (STS) were quantitatively evaluated and globally compared with thermal simulations performed by a treatment planning system. The aim was to test whether the treatment planning system was able to predict correct temperature distributions. METHODS: Five patients underwent computed tomography (CT) fluoroscopy-guided placement of tumor catheters used for the interstitial temperature measurements. For the simulations, five 3 D patient models were reconstructed by segmenting the patient CT datasets into different tissues. The measured and simulated data were evaluated by calculating the temperature change ( ΔT ), T90, T50, T20, Tmean, Tmin and Tmax, as well as the 90th percentile thermal dose (CEM43T90). In order to measure the agreement between both methods quantitatively, the Bland-Altman analysis was applied. RESULTS: The absolute difference between measured and simulated temperatures were found to be 2°, 6°, 1°, 4°, 5° and 4 °C on average for Tmin, Tmax, T90, T50, T20 and Tmean, respectively. Furthermore, the thermal simulations exhibited relatively higher thermal dose compared to those that were measured. Finally, the results of the Bland-Altman analysis showed that the mean difference between both methods was above 2 °C which is considered to be clinically unacceptable. CONCLUSION: Given the current practical limitations on resolution of calculation grid, tissue properties, and perfusion information, the software SigmaHyperPlan™ is incapable to produce thermal simulations with sufficient correlation to typically heterogeneous tissue temperatures to be useful for clinical treatment planning.


Assuntos
Hipertermia Induzida/métodos , Sarcoma/terapia , Feminino , Humanos , Masculino
4.
Eur J Nucl Med Mol Imaging ; 44(7): 1185-1193, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28197686

RESUMO

PURPOSE: To determine pre-therapeutic predictive factors for overall survival (OS) after yttrium (Y)-90 radioembolization (RE). METHODS: We retrospectively analyzed the pre-therapeutic characteristics (sex, age, tumor entity, hepatic tumor burden, extrahepatic disease [EHD] and liver function [with focus on bilirubin and cholinesterase level]) of 389 consecutive patients with various refractory liver-dominant tumors (hepatocellular carcinoma [HCC], cholangiocarcinoma [CCC], neuroendocrine tumor [NET], colorectal cancer [CRC] and metastatic breast cancer [MBC]), who received Y-90 radioembolization for predicting survival. Predictive factors were selected by univariate Cox regression analysis and subsequently tested by multivariate analysis for predicting patient survival. RESULTS: The median OS was 356 days (95% CI 285-427 days). Stable disease was observed in 132 patients, an objective response in 71 (one of which was complete remission) and progressive disease in 122. The best survival rate was observed in patients with NET, and the worst in patients with MBC. In the univariate analyses, extrahepatic disease (P < 0.001), large tumor burden (P = 0.001), high bilirubin levels (>1.9 mg/dL, P < 0.001) and low cholinesterase levels (CHE <4.62 U/I, P < 0.001) at baseline were significantly associated with poor survival. Tumor entity, tumor burden, extrahepatic disease and CHE were confirmed in the multivariate analysis as independent predictors of survival. Sex, applied RE dose and age had no significant influence on OS. CONCLUSIONS: Pre-therapeutic baseline bilirubin and CHE levels, extrahepatic disease and hepatic tumor burden are associated with patient survival after RE. Such parameters may be used to improve patient selection for RE of primary or metastatic liver tumors.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/terapia , Adulto , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Análise de Sobrevida , Carga Tumoral , Radioisótopos de Ítrio/uso terapêutico
5.
Eur Radiol ; 27(1): 113-119, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27059858

RESUMO

OBJECTIVES: Our aim was to provide further evidence for the efficacy/safety of radioembolization using yttrium-90-resin microspheres for unresectable chemorefractory liver metastases from colorectal cancer (mCRC). METHODS: We followed 104 consecutively treated patients until death. Overall survival (OS) was calculated from the day of the first radioembolization procedure. Response was defined by changes in tumour volume as defined by Response Evaluation Criteria in Solid Tumours (RECIST) v1.0 and/or a ≥30 % reduction in serum carcinoembryonic antigen (CEA) at 3 months. RESULTS: Survival varied between 23 months in patients who had a complete response to prior chemotherapy and 13 months in patients with a partial response or stable disease. Median OS also significantly improved (from 5.8 months to 17.1 months) if response durability to radioembolization extended beyond 6 months. Patients with a positive trend in CEA serum levels (≥30 % reduction) at 3 months post-radioembolization also had a survival advantage compared with those who did not: 15.0 vs 6.7 months. Radioembolization was well tolerated. Grade 3 increases in bilirubin were reported in 5.0 % of patients at 3 months postprocedure. CONCLUSIONS: After multiple chemotherapies, many patients still have a good performance status and are eligible for radioembolization. This single procedure can achieve meaningful survivals and is generally well tolerated. KEY POINTS: • After multiple chemotherapies, many patients are still eligible for radioembolization (RE). • RE can achieve meaningful survival in patients with chemorefractory liver-predominant metastatic colorectal cancer (mCRC). • Tumour responsiveness to prior systemic treatments is a significant determinant of overall survival (OS) after RE. • Radioembolization in patients with a good performance status is generally well tolerated.


Assuntos
Antineoplásicos/farmacologia , Neoplasias Colorretais/patologia , Resistencia a Medicamentos Antineoplásicos , Embolização Terapêutica/métodos , Neoplasias Hepáticas/secundário , Radioisótopos de Ítrio/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/métodos , Neoplasias Colorretais/terapia , Feminino , Humanos , Neoplasias Hepáticas/terapia , Masculino , Microesferas , Pessoa de Meia-Idade , Resultado do Tratamento
6.
Clin Hemorheol Microcirc ; 64(4): 711-719, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27814289

RESUMO

Currently methods to reduce radiation and contrast media application in endovascular repair of aortic aneurysms (EVAR) are investigated. First positive results for real-time contrast medium-enhanced ultrasonography (CEUS) guided endovascular aortic repair have been reported. A combination with image fusion of CEUS and preoperative multi-slice computed tomography (MS-CT) might offer added safety regarding stent-graft positioning and sealing of the landing zones.EVAR was performed in a patient with an asymptomatic infrarenal aortic aneurysm and a penetrating aortic ulcer in the neck region. The precise placement of the stent-graft was performed with CEUS using image fusion and native intraprocedural angiographic fluoroscopy and confirmed with digital subtraction angiography (DSA) using iondinated contrast media. At follow-up, CEUS was used to exclude endoleaks and stent-graft failure or malposition.The precise CEUS-guided placement of the stent-graft was technically successful. No artifacts due to electrical noise and metallic parts of the operating table and surgical instruments occurred. The amount of iodinated contrast media was reduced as intraoperative follow-up was performed using CEUS.CEUS with image fusion combined with intraprocedural angiographic fluoroscopy enables accurate stent-graft placement without use of any nephrotoxic contrast media. This allows EVAR in patients with renal insufficiency or allergic reactions to contrast media.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Meios de Contraste/uso terapêutico , Procedimentos Endovasculares/métodos , Transplante de Coração/métodos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Idoso , Humanos , Masculino , Espectrometria de Massas
7.
Anaesthesist ; 65(9): 655-62, 2016 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-27411524

RESUMO

Obesity leads to better survival in critically ill patients. Although there are several studies confirming this thesis, the "obesity paradox" is still surprising from the clinician's perspective. One explanation for the "obesity paradox" is the fact that the body mass index (BMI), which is used in almost all clinical evaluations to determine weight categories, is not an appropriate measure of fat and skeletal muscle mass and its distribution in critically ill patients. In addition, height and weight are frequently estimated rather than measured. Central obesity has been identified in many disorders as an independent risk factor for an unfavourable outcome. The first clues are to be found in intensive care. Along with obesity, an individual's entire muscle mass is a variable that has an influence on outcome. Central obesity can be measured relatively easily with an abdominal calliper, but the calculation of muscle mass is more complex. A valid and detailed measurement of this can be obtained using computed tomography (CT) images, acquired during routine care. For future clinical observation or interventional studies, single cross-sectional CT is a more sophisticated tool for measuring patients' anthropometry than a measuring tape and callipers. Patients with sarcopenic obesity, for example, who may be at a particular risk, can only be identified using imaging procedures such as single cross-sectional CT. Thus, BMI should take a back seat as an anthropometric tool, both in the clinic and in research.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Adiposidade , Índice de Massa Corporal , Estado Terminal/terapia , Músculo Esquelético/diagnóstico por imagem , Obesidade/diagnóstico por imagem , Gordura Abdominal/diagnóstico por imagem , Antropometria , Humanos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
9.
Rofo ; 188(2): 188-94, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26756934

RESUMO

PURPOSE: The aim of this study was to evaluate the clinical and functional outcomes in patients who underwent selective interventional embolization of renal pseudoaneurysms or arteriovenous fistulas at our center. MATERIALS AND METHODS: Our retrospective analysis included all consecutive patients who received selective transcatheter embolization of renal pseudoaneurysms or arteriovenous fistulas after partial nephrectomy in our department from January, 2003 to September, 2013. The technical and clinical success rate and functional outcome of every procedure was collected and analyzed. Furthermore, the change in renal parenchymal volume before and after embolization was determined in a subgroup. RESULTS: A total of 1425 patients underwent partial nephrectomy at our hospital. Of these, 39 (2.7 %) were identified with a pseudoaneurysm or an arteriovenous fistula after partial nephrectomy. The diagnosis of the vascular lesions was made by means of biphasic CT or CEUS. Technical success by means of selective microcoil embolization was achieved in all 39 patients (100 %). Clinical success, defined as no need for further operation or nephrectomy during follow-up, was achieved in 35 of 39 patients (85.7 %). Renal function, as measured by eGFR before and after the intervention, did not change significantly. However, a mean loss of parenchymal volume of 25.2 % was observed in a subgroup. No major or minor complications were attributable to the embolization procedure. CONCLUSION: Transcatheter embolization is a promising method for treating vascular complications which may occur after partial nephrectomy. We confirm the high success rate of this technique while discussing renal functional outcomes and potential safety aspects. KEY POINTS: Arterial pseudoaneurysms and arteriovenous fistulas are rare but severe complications after partial nephrectomy. Selective microcoil embolization is a safe and effective kidney-preserving procedure for treating these complications. Embolization leads to a significant loss of renal parenchymal volume but not to a loss of renal function.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/terapia , Fístula Arteriovenosa/diagnóstico por imagem , Fístula Arteriovenosa/terapia , Embolização Terapêutica/métodos , Doença Iatrogênica , Nefrectomia/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/terapia , Radiologia Intervencionista/métodos , Artéria Renal/lesões , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Resultado do Tratamento
10.
Clin Hemorheol Microcirc ; 61(2): 143-50, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26519228

RESUMO

PURPOSE: To evaluate the diagnostic benefits of multimodality imaging using image fusion with magnetic-resonance-imaging (MRI) and contrast-enhanced-ultrasound (CEUS) in an experimental small-animal-squamous-cell-carcinoma-model for the assessment of tissue hemodynamics and morphology. MATERIAL AND METHODS: Human hypopharynx-carcinoma-cells were injected subcutaneously into the left flank of 15 female athymic nude rats. After 10 daysof subcutaneous tumor growth, CEUS and MRI measurements were performed using a high-end-ultrasound-system and 3-T-MRI. After successful point-to-point or plan registration, the registered MR-images were simultaneously shown with the respective ultrasound sectional plane. Data evaluation was performed using the digitally stored video sequence data sets by two experienced radiologists using a subjective 5-point scale. RESULTS: CEUS and MRI are well-known techniques for the assessment of tissue hemodynamics (score: mean 3.8 ± 0.4 SD and score 3.8 ± 0.4 SD). Real-time image fusion of MRI and CEUS yielded a significant (p <  0.001) improvement in score (score 4.8 ± 0.4 SD). Reliable detection of small necrotic areas was possible in all animals with necrotic tumors. No significant intraobserver and interobserver variability was detected (kappa coefficient = +1). CONCLUSION: Image fusion of MRI and CEUS gives a significant improvement for reliable differentiation between different tumor tissue areas and simplifies investigations by showing the morphology as well as surrounding macro-/microvascularization.


Assuntos
Carcinoma de Células Escamosas/diagnóstico , Neoplasias Hipofaríngeas/diagnóstico , Animais , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Meios de Contraste , Feminino , Neoplasias Hipofaríngeas/diagnóstico por imagem , Neoplasias Hipofaríngeas/patologia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Microbolhas , Modelos Animais , Imagem Multimodal , Transplante de Neoplasias , Ratos Nus , Ultrassonografia
12.
Zentralbl Chir ; 140(5): 500-6, 2015 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-26212620

RESUMO

After edovascular repair of infrarenal aortic aneurysms (EVAR) endoleaks may occur necessitating further therapy. Therefore a reliable method for follow-up imaging after EVAR for detection and control of endoleaks is of high importance. Contrast-enhanced sonography (CEUS) does not require the application of nephrotoxid contrast media and does not stress the patient. CEUS is increasingly used and enables a quick, non-invasive follow-up examination for patient after EVAR. In addition, interventions as therapy for endoleaks may be executed using ultrasound. Initial experience with CEUS-guided aortic stenting shows that the amount of contrast media as well as X-ray time may be reduced.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/terapia , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares/métodos , Aumento da Imagem/métodos , Ultrassonografia de Intervenção/métodos , Endoleak/diagnóstico por imagem , Endoleak/terapia , Humanos , Imageamento Tridimensional/métodos , Sensibilidade e Especificidade , Ultrassonografia Doppler em Cores/métodos
13.
Cardiovasc Intervent Radiol ; 38(4): 946-56, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25986465

RESUMO

PURPOSE: To evaluate the safety of radioembolization (RE) with (90)Yttrium ((90)Y) resin microspheres depending on coiling or no-coiling of aberrant/high-risk vessels. MATERIALS AND METHODS: Early and late toxicity after 566 RE procedures were analyzed retrospectively in accordance with the National Cancer Institute's Common Terminology Criteria for Adverse Events (CTCAE v3.0). For optimal safety, aberrant vessels were either coil embolized (n = 240/566, coiling group) or a more peripheral position of the catheter tip was chosen to treat right or left liver lobes (n = 326/566, no-coiling group). RESULTS: Clinically relevant late toxicities (≥ Grade 3) were observed in 1% of our overall cohort. The no-coiling group had significantly less "any" (P = 0.0001) or "clinically relevant" (P = 0.0003) early toxicity. There was no significant difference (P > 0.05) in delayed toxicity in the coiling versus the no-coiling group. No RE-induced liver disease was noted after all 566 procedures. CONCLUSION: RE with (90)Y resin microspheres is a safe and effective treatment option. Performing RE without coil embolization of aberrant vessels prior to treatment could be an alternative for experienced centers.


Assuntos
Braquiterapia/efeitos adversos , Embolização Terapêutica/métodos , Neoplasias Hepáticas/radioterapia , Radioisótopos de Ítrio/uso terapêutico , Humanos , Fígado/efeitos da radiação , Microesferas , Estudos Retrospectivos , Resultado do Tratamento
14.
Clin Hemorheol Microcirc ; 57(2): 101-10, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24577380

RESUMO

PURPOSE: To evaluate the ultrasound tissue elasticity imaging by comparison to multimodality imaging using image fusion with Magnetic Resonance Imaging (MRI) and conventional grey scale imaging with additional elasticity-ultrasound in an experimental small-animal-squamous-cell carcinoma-model for the assessment of tissue morphology. METHOD AND MATERIALS: Human hypopharynx carcinoma cells were subcutaneously injected into the left flank of 12 female athymic nude rats. After 10 days (SD ± 2) of subcutaneous tumor growth, sonographic grey scale including elasticity imaging and MRI measurements were performed using a high-end ultrasound system and a 3T MR. For image fusion the contrast-enhanced MRI DICOM data set was uploaded in the ultrasonic device which has a magnetic field generator, a linear array transducer (6-15 MHz) and a dedicated software package (GE Logic E9), that can detect transducers by means of a positioning system. Conventional grey scale and elasticity imaging were integrated in the image fusion examination. After successful registration and image fusion the registered MR-images were simultaneously shown with the respective ultrasound sectional plane. Data evaluation was performed using the digitally stored video sequence data sets by two experienced radiologist using a modified Tsukuba Elasticity score. The colors "red and green" are assigned for an area of soft tissue, "blue" indicates hard tissue. RESULTS: In all cases a successful image fusion and plan registration with MRI and ultrasound imaging including grey scale and elasticity imaging was possible. The mean tumor volume based on caliper measurements in 3 dimensions was ~323 mm3. 4/12 rats were evaluated with Score I, 5/12 rates were evaluated with Score II, 3/12 rates were evaluated with Score III. There was a close correlation in the fused MRI with existing small necrosis in the tumor. None of the scored II or III lesions was visible by conventional grey scale. CONCLUSION: The comparison of ultrasound tissue elasticity imaging enables a secure differentiation between different tumor tissue areas in comparison to image fusion with MRI in our small study group. Therefore ultrasound tissue elasticity imaging might be used for fast detection of tumor response in the future whereas conventional grey scale imaging alone could not provide the additional information. By using standard, contrast-enhanced MRI images for reliable and reproducible slice positioning, the strongly user-dependent limitation of ultrasound tissue elasticity imaging may be overcome, especially for a comparison between baseline and follow-up measurements.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Imagem Multimodal/métodos , Animais , Feminino , Humanos , Imageamento por Ressonância Magnética , Modelos Animais , Ratos , Ratos Nus
15.
Oncology ; 86(1): 24-32, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24401529

RESUMO

OBJECTIVE: To analyze the clinical efficacy of (90)Y radioembolization in liver metastases from pancreatic cancer, to describe treatment toxicities and to identify biomarkers as predictors of outcome. METHODS: Data from 19 pancreatic cancer patients (9 females/10 males) who had received (90)Y radioembolization for metastatic liver disease between 06/2004 and 01/2011 were analyzed retrospectively. RESULTS: The median age at (90)Y radioembolization was 63 years (range 43-77). In 16 patients, previous palliative gemcitabine-based chemotherapy was given for metastatic disease. Objective response in the liver after (90)Y radioembolization was 47%. Median local progression-free survival in the liver was 3.4 months (range 0.9-45.0). Median overall survival (OS) was 9.0 months (range 0.9-53.0) and 1-year survival was 24%. Cox regression models for baseline biomarkers at (90)Y radioembolization revealed correlations of increased carbohydrate antigen 19-9 (p = 0.02) and C-reactive protein (p = 0.03) with shorter OS. Short-term adverse events (nausea, vomiting, fatigue, fever and abdominal pain) did not exceed grade 3. As long-term adverse events, liver abscesses, gastroduodenal ulceration, cholestasis and cholangitis, ascites and spleen infarction were observed. CONCLUSION: (90)Y radioembolization is able to induce an encouraging local response rate of liver metastases of pancreatic cancer patients. Most short-term toxicities are manageable; however, patients should be followed up carefully for severe long-term toxicities.


Assuntos
Embolização Terapêutica/métodos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Microesferas , Neoplasias Pancreáticas/patologia , Radioisótopos de Ítrio/administração & dosagem , Adulto , Idoso , Embolização Terapêutica/efeitos adversos , Feminino , Humanos , Neoplasias Hepáticas/mortalidade , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Radioisótopos de Ítrio/efeitos adversos
16.
Radiologe ; 53(11): 974-85, 2013 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-24231823

RESUMO

Although ultrasound and magnetic resonance imaging are competitive imaging modalities for the guidance of needle-based interventions, computed tomography (CT) is the only modality suitable for image-guided interventions in all regions of the body, including the lungs and bone. The ongoing technical development of CT involves accelerated image acquisition, significantly improved spatial resolution, CT scanners with an extended gantry diameter, acceleration of the procedure through joystick control of relevant functions of interventional CT by the interventional radiologist and tube current modulation to protect the hands of the examiner and radiosensitive organs of the patient. CT fluoroscopy can be used as a real-time method (the intervention is monitored under continuous CT fluoroscopy) or as a quick check method (repeated acquisitions of individual CT fluoroscopic images after each change of needle or table position). For the two approaches, multislice CT fluoroscopy (MSCTF) technique with wide detectors is particularly useful because even in the case of needle deviation from the center slice the needle tip is simultaneously visualised in the neighboring slices. With the aid of this technique a precise placement of interventional devices is possible even in angled access routes and in the presence of pronounced respiratory organ movements. As the reduction of CT fluoroscopy time significantly reduces radiation exposure for the patient and staff, the combination of a quick check technique and a low milliampere technique with multislice CT fluoroscopy devices is advantageous.


Assuntos
Fluoroscopia/métodos , Intensificação de Imagem Radiográfica/métodos , Radiografia Intervencionista/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos
17.
Semin Ultrasound CT MR ; 34(3): 196-203, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23768886

RESUMO

Ultrasound examination is the imaging procedure with the best predictive diagnostic capability for the salivary glands. Due to the salivary glands' relatively superficial anatomical location, clear boundary from surrounding tissue and comparatively typical echogenicity, therefore sonography is ideal for diagnosis. In addition, the technical advances in recent years, including higher resolution, color Doppler sonography, contrast-enhanced ultrasound, elastography, and tissue harmonic have lead to an improvement in diagnostic accuracy of sonography further resulting in an expansion of the range of indications. Sonography allows detection of obstructive salivary gland diseases such as stenosis or sialolithiasis, as well as sialadenosis such as Sjögren syndrome. Ultrasound examination alone is sufficient to diagnose benign tumors. However, in the case of malignant tumors, computer tomography or MRI may be also required, especially to determine the question of infiltration of the skull base.


Assuntos
Aumento da Imagem/métodos , Doenças das Glândulas Salivares/diagnóstico por imagem , Glândulas Salivares/diagnóstico por imagem , Ultrassonografia/métodos , Humanos
18.
Digestion ; 86(4): 338-48, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23207185

RESUMO

PURPOSE: To evaluate the efficiency of a multimodality approach consisting of transcatheter arterial chemoembolization (TACE) and radiofrequency ablation (RFA) as bridging therapy for patients with hepatocellular carcinoma (HCC) awaiting orthotopic liver transplantation (OLT) and to evaluate the histopathological response in explant specimens. MATERIALS AND METHODS: Between April 2001 and November 2011, 36 patients with 50 HCC nodules (1.4-5.0 cm, median 2.8 cm) on the waiting list for liver transplantation were treated by TACE and RFA. The drop-out rate during the follow-up period was recorded. The local efficacy was evaluated by histopathological examination of the explanted livers. RESULTS: During a median follow-up time of 29 (4.0-95.3) months the cumulative drop-out rate for the patients on the waiting list was 0, 2.8, 5.5, 11.0, 13.9 and 16.7% at 3, 6, 12, 24, 36 and 48 months, respectively. 16 patients (with 26 HCC lesions) out of 36 (44.4%) were transplanted by the end of study with a median waiting list time of 13.7 (2.5-37.8) months. The histopathological examination of the explanted specimens revealed a complete necrosis in 20 of 26 HCCs (76.9%), whereas 6 (23.1%) nodules showed viable residual tumor tissue. All transplanted patients are alive at a median time of 29.9 months. Imaging correlation showed 100% specificity and 66.7% sensitivity for the depiction of residual or recurrent tumor. CONCLUSION: We conclude that TACE combined with RFA could provide an effective treatment to decrease the drop-out rate from the OLT waiting list for HCC patients. Furthermore, this combination therapy results in high rates of complete tumor necrosis as evaluated in the histopathological analysis of the explanted livers. Further randomized trials are needed to demonstrate if there is a benefit in comparison with a single-treatment approach.


Assuntos
Carcinoma Hepatocelular/terapia , Ablação por Cateter , Quimioembolização Terapêutica , Neoplasias Hepáticas/terapia , Transplante de Fígado , Recidiva Local de Neoplasia/diagnóstico , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Terapia Combinada , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neoplasia Residual , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo , Listas de Espera
19.
Clin Hemorheol Microcirc ; 52(2-4): 107-14, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22960296

RESUMO

PURPOSE: To evaluate "bolus-tracking" (BT) and "flash-replenishment" (FR) for the assessment of tissue hemodynamics by contrast-enhanced ultrasound (CEUS) in an experimental small-animal-squamous-cell-carcinoma-model. Since the underlying tissue is the same, strong correlations between parameter outcomes of both techniques are expected. METHODS AND MATERIALS: Human hypopharynx-carcinoma-cells were subcutaneously injected into the left flank of 18 female athymic-nude-rats. After 10 days of subcutaneous tumour growth, bolus tracking and flash-replenishment measurements were performed consecutively in the same imaging plane in each rat after bolus-injection of SonoVue via the lateral tail vein using a high-end ultrasound system with a 15 MHz probe. Video-sequences were analysed with dedicated software (VueBox®, Bracco-Suisse®). From BT measurements, the parameters peak enhancement (PEBT), wash-in area-under-the-curve (Wi-AUCBT), mean transit time (MTTBT), wash-in-rate (WiRBT) and perfusion-index (Wi-PIBT) were derived; FR yielded estimates of relative-blood-volume (rBVFR), mean transit time MTTFR, relative blood flow rBFFR and wash-in rate Wi-RFR. RESULTS: In all rats, BT and FR measurements could be completed successfully. Highly significant correlations were observed between rBVFR and PEBT, rBVFR and Wi-AUCBT, rBVFR and MTTBT, rBVFR and WiPIBT, MTTFR and MTTBT, rBFFR and PEBT, rBFFR and Wi-AUCBT, rBFFR and WiRBT, rBFFR and WiPIBT, WiRFR and PEBT, WiRFR and Wi-AUCBT, WiRFR and WiRBT and WiRFR and WiPIBT. CONCLUSION: Whereas bolus tracking can be used in a wide range of modalities including CEUS, CT and MR, FR as a technique for the assessment of tissue hemodynamics is unique to CEUS. Although BT and FR yield different parameters, the underlying tissue hemodynamics are equal. In this work, we were able to demonstrate strong correlations between different parameters of both modalities in a small-animal-tumor-model, indicating that flash-replenishment is a valid alternative to the more established bolus-tracking technique. Although the lack of absolute, quantitative parameters hinders a direct comparison of both modalities, FR and BT should both be suitable for a relative comparison, e.g. between baseline and follow-up examinations.


Assuntos
Carcinoma de Células Escamosas/irrigação sanguínea , Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias Hipofaríngeas/irrigação sanguínea , Neoplasias Hipofaríngeas/diagnóstico por imagem , Animais , Meios de Contraste , Modelos Animais de Doenças , Feminino , Hemodinâmica , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Ratos , Ratos Nus , Transplante Heterólogo , Ultrassonografia/métodos
20.
Clin Hemorheol Microcirc ; 52(2-4): 205-16, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22960300

RESUMO

PURPOSE: The purpose of this study was to evaluate whether image fusion with contrast enhanced ultrasound (CEUS) and CT is effective in the pre-, intra- and post-interventional management of liver lesions during microwave or radiofrequency ablation. METHODS AND MATERIALS: Fifteen patients with a single hepatocellular carcinoma (HCC) up to 3 cm diameter, identified on both contrast-enhanced CT (Siemens Somatom Definition AS and Definition Edge, Siemens Healthcare, Erlangen, Germany) and ultrasound (Siemens ACUSON S2000™ or S3000™, Siemens Healthcare, Erlangen, Germany) were retrospectively enrolled between July 2011 and May 2012. Either automatic registration or plane match registration was chosen on CT and ultrasound for the pre-, intra- and postinterventional management of all treated liver lesions during microwave or radiofrequency ablation. Using conventional ultrasound B-mode, CEUS and image fusion including B-mode and CEUS the detectability of the liver lesions was evaluated semi-quantitatively by comparing the image sequences in a consensus reading. Eight patients underwent radiofrequency ablation and seven patients underwent microwave ablation. RESULTS: All patients were examined using all diagnostic ultrasound tools of the study. The results show that the procedure is easy and convenient to perform, as well as efficient. The co-registration procedure took approximately 5 to 10 minutes depending on the amount of DICOM volume-data and the habitus of the patient. The results show that the use of image fusion with CT and contrast-enhanced ultrasound could improve the diagnostic assessment capabilities in comparison to the examination without image fusion in the pre-, intra- and postinterventional management of malignant liver lesions during thermal ablation. CONCLUSION: Percutaneous thermal ablation guided by contrast-enhanced ultrasound and image fusion seems to be an efficient approach for malignant liver lesions especially if these are not clearly demarcated by B-mode. The use of the image fusion technique in the pre-, intra- and postinterventional management can increase operator confidence, the accuracy of the procedure, and technical success in real time.


Assuntos
Técnicas de Ablação/métodos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Idoso , Carcinoma Hepatocelular/terapia , Meios de Contraste , Feminino , Ablação por Ultrassom Focalizado de Alta Intensidade , Humanos , Hipertermia Induzida/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...