Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orthop Case Rep ; 14(6): 191-197, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38910981

RESUMO

Introduction: The use of image-free robotic systems for total knee arthroplasty (TKA) is gaining popularity. Although the surgical transepicondylar axis (sTEA) is considered the optimal femoral rotational reference during TKA, it is difficult to define intra-operatively. Conventional and image-free robot-assisted TKA (RA-TKA) therefore rely on the use of Whiteside's axis (WSA) or the posterior condylar axis (PCA) as surrogate references. The PCA is considered to be associated with less variability than the WSA. The authors present a simple technique to permit calibration of femoral component rotation (FCR) using the PCA as a reference for image-free robotic systems that do not permit this option. Technique: The image-free robotic systems used by the authors (Navio and CORI, Smith and Nephew, Memphis, TN, USA) permit calibration of FCR only when the perpendicular to WSA is used as a reference. When the PCA is selected as a reference, a fixed 3° of external rotation is set by the robot. The technique proposed by the authors involves the use of the former setting, followed by internal rotation of the perpendicular to the WSA to co-align it with the PCA. The planning menu subsequently permits virtual surgical planning using the PCA as the femoral rotational reference and permits adjustments in rotational positioning of the femoral component while displaying the effect of rotation on bony resection and vice versa in real time. In addition, coaligning the perpendicular to the anatomic trans-epicondylar axis (aTEA) displays the internal rotation of the PCA with respect to the aTEA. This information can be used for setting rotational boundaries with respect to the PCA while using various alternate alignment strategies, like functional alignment, since the relation between the aTEA and sTEA is less likely to be affected by dyplasia and wear when compared with the PCA or WSA. Conclusion: This simple technique permits optimally calibrated rotational positioning of the femoral component during image-free RA-TKA, using the PCA as a reference. It can be applied for optimizing surgery in knees with altered or outlier anatomy, as well as routinely, especially when alternate alignment strategies are used.

2.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38635780

RESUMO

CASE: A 47-year-old orthopaedic surgeon presented with acute volar left wrist pain. He performed over 250 robot-assisted knee arthroplasties each year. Color Doppler evaluation revealed bilateral persistent median arteries and bifid median nerves, with focal occlusive thrombosis of the left median artery. He was advised rest and oral aspirin. He could return to his professional activities after 1 month. He had no recurrence of symptoms at 1 year of follow-up. CONCLUSION: Orthopaedic surgeons use vibrating hand tools on a daily basis. The possibility of hand-arm vibration syndrome must be considered in the differential diagnosis of wrist pain among orthopaedic surgeons.


Assuntos
Artroplastia do Joelho , Síndrome do Túnel Carpal , Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgiões , Trombose , Humanos , Masculino , Pessoa de Meia-Idade , Artérias , Artralgia/cirurgia , Síndrome do Túnel Carpal/cirurgia , Nervo Mediano/cirurgia , Trombose/etiologia , Trombose/complicações
3.
Cureus ; 16(2): e55296, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38558674

RESUMO

Pilar cysts are derived from the outer layer of the root sheath of hair follicles. They were conventionally thought to arise from hair-bearing skin like the scalp. However, this notion has been refuted recently. Pilar cysts of the hand are extremely rare, with only a few case reports in the literature. We report the case of a 40-year-old male patient, with no known medical co-morbidities, who presented with a swelling over his left thumb. It was occasionally painful, and caused difficulty in grasping objects. Physical examination revealed a 2.5 x 1.5 cm swelling over the volar aspect of the thumb, at the level of the proximal phalanx. MRI revealed the presence of a well-defined cystic lesion superficial to the flexor tendons. The possibility of an epidermal cyst was considered, and the patient was advised surgery in view of his symptoms and progression in the size of the swelling. He underwent excision of the lesion along with a segment of adherent skin. Histopathological examination of the lesion revealed the presence of a pilar cyst. The patient did not have recurrence of symptoms following surgery, and was found to be doing well at the three-year follow-up. This case report urges a re-thinking of the possible origins of pilar cysts from atypical locations.

4.
J Robot Surg ; 18(1): 62, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38308659

RESUMO

The use of appropriately sized implants is critical for achieving optimal gap balance following total knee arthroplasty (TKA). Inappropriately sized implants could result in several complications. Robot-assisted TKA (RA-TKA) using CT-based pre-operative planning predicts implant sizes with high accuracy. There is scant literature describing the accuracy of image-free RA-TKA in predicting implant sizes. The purpose of this study was to assess the accuracy of an image-free robotic system in predicting implant sizes during RA-TKA. Patients who underwent cruciate-retaining RA-TKA for primary osteoarthritis, using an image-free hand-held robotic system were studied. The predicted and implanted sizes of the femoral component, tibial component and polyethylene insert, for 165 patients, were recorded. Agreement between robot-predicted and implanted component sizes was assessed in percentages, while reliability was assessed using Cohen's weighted kappa coefficient. The accuracy of the robotic system was 63% (weighted-kappa = 0.623, P < 0.001), 94% (weighted-kappa = 0.911, P < 0.001) and 99.4% (weighted-kappa = 0.995, P < 0.001), in predicting exact, ± 1 and ± 2 sizes of the femoral component, respectively. For the tibial component, an accuracy of 15.8% (weighted-kappa = 0.207, P < 0.001), 55.8% (weighted-kappa = 0.378, P < 0.001) and 76.4% (weighted-kappa = 0.568, P < 0.001) was noted, for predicting exact, ± 1 and ± 2 sizes respectively. An accuracy of 88.5%, 98.2% and 100%, was noted for predicting exact, ± 1 and ± 2 sizes of the polyethylene insert respectively. Errors in predicting accurate implant sizes could be multi-factorial. Though the accuracy of image-free RA-TKA with respect to alignment and component positioning is established, the surgeon's expertise should be relied upon while deciding appropriate implant sizes.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Reprodutibilidade dos Testes , Polietilenos
5.
Infection ; 50(4): 889-895, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35129788

RESUMO

PURPOSE: The rollout of COVID-19 vaccines began in India in January 2021, with healthcare professionals being the first to receive vaccination. The purpose of this research was to study the incidence and severity of COVID-19 infections among Indian doctors, following vaccination with ChAdOx1 nCoV-19 or BBV152. METHODS: We conducted an online voluntary survey among Indian doctors who received one or two doses of ChAdOx1 nCoV-19 or BBV152. Questions pertaining to the incidence and severity of COVID-19 infection following vaccination were asked. Data thus obtained were analysed. RESULTS: 9146 doctors were included in this study. 8301 of these received ChAdOx1 nCoV-19, while 845 received BBV152. 2842 (31.07%) respondents reported having a COVID-19 infection following vaccination. Presence of pre-existing medical comorbidities was associated with a higher incidence, while prior COVID-19 infection and two doses of either vaccine were associated with a lower incidence of COVID-19 infection post-vaccination. Exposure to COVID-19 patients on a daily basis did not increase the incidence of COVID-19 infection among doctors who were vaccinated. Increasing age, male gender, presence of pre-existing medical comorbidities, and daily exposure to COVID-19 patients were associated with increased severity of COVID-19 infection after vaccination. Two doses of either vaccine resulted in less severity of disease compared to one dose. CONCLUSION: ChAdOx1 nCoV-19 and BBV152 confer immunity against severe forms of COVID-19 infections. COVID-19 infections prior to vaccination result in a lower incidence of breakthrough infection. Presence of pre-existing medical comorbidities is associated with increased incidence and severity of breakthrough infections.


Assuntos
Vacinas contra COVID-19 , COVID-19 , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , ChAdOx1 nCoV-19 , Humanos , Incidência , Masculino , Inquéritos e Questionários , Vacinação/efeitos adversos
7.
Arthroplasty ; 2(1): 32, 2020 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-35236457

RESUMO

BACKGROUND: Trunnion fracture of the femoral prosthesis is an extremely rare complication following Total Hip Arthroplasty (THA). There are very few reports in literature on trunnion fracture. All previously reported cases are of prostheses with smaller heads, unlike the large metal-on-metal articulation in our case, which is unique. CASE PRESENTATION: A 29-year-old male patient with juvenile idiopathic arthropathy presented to us with a fracture of the trunnion of his left THA, with no history of trauma. He had undergone staged bilateral THA for avascular necrosis of the hips 10 years ago (with AML-A stem and large metal-on-metal articulation bilaterally). We revised the THA and exchanged both femoral and acetabular components. He had a good functional outcome at 3 years' follow up. CONCLUSION: The primary reason for the trunnion fracture in our case was the faulty stem design of the AML [with a small (9/10) taper, and a large head], causing excessive bending moment at the trunnion, worsening the cantilever effect and leading to subsequent cyclic fatigue failure. Whilst gross trunnion failure (GTF) with dissociation of the head from the taper is commonly reported, trunnion fracture per se is a rare and devastating complication. The AML-A stem has since been recalled by the company and there is a need to constantly monitor these patients for potential trunnion-related complications.

8.
J Clin Orthop Trauma ; 7(Suppl 2): 225-229, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28053389

RESUMO

INTRODUCTION: Epidemiologic data on the incidence of venous thromboembolism (VTE) in Indian population vary widely. Most studies show that the incidence of VTE is lower in Asian patients than in Western population. Screening tools to identify high-risk patients should enable us to reduce this complication. METHODS: The incidence of VTE in 101 patients who underwent knee or hip arthroplasty, or surgery for hip fractures, without chemoprophylaxis for deep vein thrombosis (DVT) was documented. Diagnosis of DVT was made with Duplex ultrasonography. We also assessed the usefulness of pre-operative assessment of the hypercoagulable status of the patient in predicting the occurrence of VTE, using the Thrombelastography (TEG) test. RESULTS: The incidence of DVT in the study population was 7%. Six of the 7 patients who developed DVT had surgery for hip fractures, while one had knee replacement. The thrombus was above the knee joint level in 6 of the 7 patients. Pre-operative TEG was positive in only one of the 7 patients, but was positive in 37 of the remaining 94 patients. CONCLUSION: Incidence of DVT in the study population is sufficiently high to recommend some form of prophylaxis to prevent VTE following hip and knee surgery. Pre-operative assessment of the patients' coagulation status with Thrombelastography does not predict the risk of VTE. The use of other lab parameters that could help in selective chemoprophylaxis needs to be explored.

9.
Indian J Radiol Imaging ; 23(1): 101-5, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23986625

RESUMO

This study describes a group of 26 patients with ochronotic spondyloarthropathy who were on regular treatment and follow-up at a tertiary level hospital and proposes a simplified staging system for ochronotic spondyloarthropathy based on radiographic findings seen in the thoracolumbar spine. This proposed classification makes it easy to identify the stage of the disease and start the appropriate management at an early stage. Four progressive stages are described: an inflammatory stage (stage 1), the stage of early discal calcification (stage 2), the stage of fibrous ankylosis (stage 3), and the stage of bony ankylosis (stage 4). To our knowledge, this is the largest reported series of radiological description of spinal ochronosis, and emphasizes the contribution of the spine radiograph in the diagnosis and staging of the disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...