Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Am J Cardiol ; 208: 118-123, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37832208

RESUMO

Transcatheter patent foramen ovale (PFO) closure is indicated for patients with cryptogenic stroke. Although procedural safety is well established, there are limited data on the safety of same-day (SD) discharge. We aimed to review the outcomes of PFO closure with SD. Patients who underwent transcatheter PFO closure between January 2011 and May 2022 at 4 large US hospitals were retrospectively analyzed, comparing outcomes of SD versus delayed discharge (DD). The primary end point was a composite of access-site complication, stroke, device embolization, atrial arrhythmia, and bleeding. Secondary analysis comparing imaging modality and outcomes was performed. 554 patients (49.2% female) were analyzed (382 discharged SD). Average age was 54.3 ± 15. Baseline characteristics in both groups were broadly similar. Previous stroke (78.0% SD vs 76.2% DD, p = 0.32) was the commonest indication for PFO closure. In the SD group, there was less general anesthesia use (5.5% vs 16.9%, p <0.001). Intraprocedural intracardiac echocardiography was used more frequently in SD cases (95.0% vs 81.4%, p <0.001). In the DD group, median stay was 1 night, and 34.9% stayed beyond 1 night. At 30 days, there was no difference in the primary composite end point (14.9% vs 11.6%, p = 0.15). There was no inter-group difference in individual adverse events (all p >0.05). When comparing imaging modality and outcomes, there was no difference in composite end points between transesophageal and intracardiac echocardiography (6.5% vs 14.7%, p = 0.063). In conclusion, SD discharge after transcatheter PFO closure appears safe. This efficient approach may be advantageous in optimizing workflow and minimizing hospital occupancy.


Assuntos
Forame Oval Patente , Acidente Vascular Cerebral , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cateterismo Cardíaco/métodos , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Estudos Multicêntricos como Assunto , Recidiva Local de Neoplasia/complicações , Alta do Paciente , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/complicações , Resultado do Tratamento
2.
Methodist Debakey Cardiovasc J ; 19(3): 105-107, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37213873

RESUMO

Aortic stenosis is the most common valvular heart disease in the elderly population. Since the advent of transcatheter aortic valve implantation (TAVI) in 2002, the clinical indications for this alternative to a surgical replacement have continually expanded. While the treatment of octo- and nonagenarians can present significant challenges, here we present a case of TAVI in an elderly patient. Given her suitable anatomy and active lifestyle that had been limited by her disease state, the patient successfully underwent TAVI 3 weeks later and was discharged post-operative day 1. This case is the basis for providing five key points to remember about the work-up for TAVI for severe aortic stenosis in the elderly population.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco
4.
Blood ; 137(9): 1208-1218, 2021 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-33181835

RESUMO

Previous reports indicate that IL18 is a novel candidate gene for diastolic dysfunction in sickle cell disease (SCD)-related cardiomyopathy. We hypothesize that interleukin-18 (IL-18) mediates the development of cardiomyopathy and ventricular tachycardia (VT) in SCD. Compared with control mice, a humanized mouse model of SCD exhibited increased cardiac fibrosis, prolonged duration of action potential, higher VT inducibility in vivo, higher cardiac NF-κB phosphorylation, and higher circulating IL-18 levels, as well as reduced voltage-gated potassium channel expression, which translates to reduced transient outward potassium current (Ito) in isolated cardiomyocytes. Administering IL-18 to isolated mouse hearts resulted in VT originating from the right ventricle and further reduced Ito in SCD mouse cardiomyocytes. Sustained IL-18 inhibition via IL-18-binding protein resulted in decreased cardiac fibrosis and NF-κB phosphorylation, improved diastolic function, normalized electrical remodeling, and attenuated IL-18-mediated VT in SCD mice. Patients with SCD and either myocardial fibrosis or increased QTc displayed greater IL18 gene expression in peripheral blood mononuclear cells (PBMCs), and QTc was strongly correlated with plasma IL-18 levels. PBMC-derived IL18 gene expression was increased in patients who did not survive compared with those who did. IL-18 is a mediator of sickle cell cardiomyopathy and VT in mice and a novel therapeutic target in patients at risk for sudden death.


Assuntos
Anemia Falciforme/complicações , Cardiomiopatias/etiologia , Interleucina-18/sangue , Taquicardia Ventricular/etiologia , Adulto , Anemia Falciforme/sangue , Anemia Falciforme/fisiopatologia , Animais , Arritmias Cardíacas/sangue , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Cardiomiopatias/sangue , Cardiomiopatias/fisiopatologia , Humanos , Interleucina-18/análise , Masculino , Camundongos , Taquicardia Ventricular/sangue , Taquicardia Ventricular/fisiopatologia , Adulto Jovem
5.
JACC Case Rep ; 2(8): 1089-1092, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34317421

RESUMO

We present this case of a 22-year-old woman with congenital heart disease as the youngest reported patient, to the best of our knowledge, to successfully undergo treatment of medically refractory torrential tricuspid regurgitation with the MitraClip system as an adjunct to guideline directed therapy. (Level of Difficulty: Advanced.).

6.
Curr Treat Options Cardiovasc Med ; 21(1): 2, 2019 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-30685799

RESUMO

PURPOSE OF REVIEW: The purpose of this review is to identify the anatomical difficulties an operator may encounter during the transradial approach for cardiac catheterization and to offer tips and tricks to overcome those challenges. RECENT FINDINGS: With increasing implementation of the transradial approach for cardiac catheterization, many new techniques have been utilized to overcome anatomical challenges. This article also discusses the difficulties faced during transradial approach in patients with prior coronary artery bypass grafting (CABG). Numerous large randomized trials have demonstrated the value of the transradial approach over the transfemoral approach during cardiac catheterization. However, this technique is routinely avoided or aborted due to anatomical variations in the upper arm and chest. These obstacles have delayed adoption of transradial access by operators despite the apparent benefits. This article reviews some of the available tips and tricks described in the literature to overcome anatomical obstacles. By implementing some of these tools into practice, an operator may realize improved procedural success, decreased procedure time, and improved patient comfort with the transradial approach.

7.
PLoS One ; 11(10): e0164526, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27736922

RESUMO

Sudden death is a leading cause of mortality in sickle cell disease, implicating ventricular tachyarrhythmias. Prolonged QTc on an electrocardiogram (ECG), commonly seen with myocardial ischemia, is a known risk for polymorphic ventricular tachycardia (VT). We hypothesized that prolonged QTc is associated with mortality in sickle cell disease. ECG were analyzed from a cohort of 224 sickle patients (University of Illinois at Chicago, UIC) along with available laboratory, and echocardiographic findings, and from another cohort of 38 patients (University of Chicago, UC) for which cardiac MRI and free heme values were also measured. In the UIC cohort, QTc was potentially related to mortality with a hazard ratio (HR) of 1.22 per 10ms, (P = 0.015), and a HR = 3.19 (P = 0.045) for a QTc>480ms. In multivariate analyses, QTc remained significantly associated with survival after adjusting for inpatient ECG status (HR 1.26 per 10ms interval, P = 0.010) and genotype status [HR 1.21 per 10ms interval, P = 0.037). QTc trended toward association with mortality after adjusting for both LDH and hydroxyurea use (HR 1.21 per 10ms interval, P = 0.062) but was not significant after adjusting for TRV. In univariate analyses, QTc was related to markers of hemolysis including AST (P = 0.031), hemoglobin (P = 0.014), TR velocity (P = 0.036), higher in inpatients (P<0.001) and those with an SS compared to SC genotype (P<0.001) in the UIC cohort as well as to free heme in the UC cohort (P = 0.002). These findings support a relationship of prolonged QTc with hemolysis and potentially mortality in sickle cell disease.


Assuntos
Anemia Falciforme/diagnóstico , Síndrome do QT Longo/etiologia , Adulto , Anemia Falciforme/complicações , Anemia Falciforme/tratamento farmacológico , Aspartato Aminotransferases/metabolismo , Estudos de Coortes , Morte Súbita Cardíaca/etiologia , Ecocardiografia , Eletrocardiografia , Feminino , Genótipo , Coração/diagnóstico por imagem , Hemoglobinas/genética , Hemoglobinas/metabolismo , Hemólise , Humanos , Hidroxiureia/uso terapêutico , Estimativa de Kaplan-Meier , L-Lactato Desidrogenase/metabolismo , Síndrome do QT Longo/mortalidade , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Análise de Regressão , Fatores de Risco
8.
Proc Natl Acad Sci U S A ; 101(20): 7516-21, 2004 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-15136742

RESUMO

To achieve high mixing efficiency in microfluidic devices, complex designs are often required. Microfluidic devices have been evaluated with light and confocal microscopy, but fluid-flow characteristics at different depths are difficult to separate from the en face images produced. By using optical coherence tomography (OCT), an imaging modality capable of imaging 3D microstructures at micrometer-scale resolutions over millimeter-size scales, we obtained 3D dynamic functional and structural data for three representative microfluidic mixers: a Y channel mixer, a 3D serpentine mixer, and a vortex mixer. In the serpentine mixer, OCT image analysis revealed that the mixing efficiency was linearly dependent on the Reynolds number, whereas it appeared to have exponential dependence when imaged with light microscopy. The visual overlap of fluid flows in light-microscopy images leads to an overestimation of the mixing efficiency, an effect that was eliminated with OCT imaging. Doppler OCT measurements determined velocity profiles at various points in the serpentine mixer. Mixing patterns in the vortex mixer were compared with light-microscopy and OCT image analysis. These results demonstrate that OCT can significantly improve the characterization of 3D microfluidic device structure and function.


Assuntos
Microfluídica/métodos , Tomografia de Coerência Óptica , Microscopia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...