Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Semin Radiat Oncol ; 34(4): 418-425, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39271276

RESUMO

The implementation and early adoption of online adaptive radiotherapy (oART) has required the presence of clinicians, physicists and radiation therapists (RTT) at the treatment console. The impact on each of them is unique to their profession and must be considered for safe and efficient implementation. In the short term future, widespread adoption will depend on the development of innovative workflows, and rethinking of traditional roles and responsibilities may be required. For the future, technologies such as artificial intelligence promise to change the workflow significantly in terms of speed, automation and decision-making. However, overall communication within the team will persist in being one of the most important aspects.


Assuntos
Equipe de Assistência ao Paciente , Humanos , Equipe de Assistência ao Paciente/organização & administração , Neoplasias/radioterapia , Neoplasias/terapia , Inteligência Artificial , Radioterapia (Especialidade) , Fluxo de Trabalho , Planejamento da Radioterapia Assistida por Computador/métodos
2.
Phys Med Biol ; 62(4): 1327-1341, 2017 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-28114115

RESUMO

Radio-opaque fiducial markers of different shapes are often implanted in or near abdominal or thoracic tumors to act as surrogates for the tumor position during radiotherapy. They can be used for real-time treatment adaptation, but this requires a robust, automatic segmentation method able to handle arbitrarily shaped markers in a rotational imaging geometry such as cone-beam computed tomography (CBCT) projection images and intra-treatment images. In this study, we propose a fully automatic dynamic programming (DP) assisted template-based (TB) segmentation method. Based on an initial DP segmentation, the DPTB algorithm generates and uses a 3D marker model to create 2D templates at any projection angle. The 2D templates are used to segment the marker position as the position with highest normalized cross-correlation in a search area centered at the DP segmented position. The accuracy of the DP algorithm and the new DPTB algorithm was quantified as the 2D segmentation error (pixels) compared to a manual ground truth segmentation for 97 markers in the projection images of CBCT scans of 40 patients. Also the fraction of wrong segmentations, defined as 2D errors larger than 5 pixels, was calculated. The mean 2D segmentation error of DP was reduced from 4.1 pixels to 3.0 pixels by DPTB, while the fraction of wrong segmentations was reduced from 17.4% to 6.8%. DPTB allowed rejection of uncertain segmentations as deemed by a low normalized cross-correlation coefficient and contrast-to-noise ratio. For a rejection rate of 9.97%, the sensitivity in detecting wrong segmentations was 67% and the specificity was 94%. The accepted segmentations had a mean segmentation error of 1.8 pixels and 2.5% wrong segmentations.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico/métodos , Marcadores Fiduciais , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Automação , Suspensão da Respiração , Simulação por Computador , Humanos , Curva ROC
3.
Phys Med Biol ; 55(1): 65-82, 2010 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-19949260

RESUMO

Electromagnetic tracking technology is primarily used for continuous prostate localization during radiotherapy, but offers potential value for evaluation of dosimetric coverage and adequacy of treatment for dynamic targets. We developed a highly automated method for daily computation of cumulative dosimetric effects of intra- and inter-fraction target motion for prostate cancer patients using fiducial-based electromagnetic tracking. A computer program utilizing real-time tracking data was written to (1) prospectively determine appropriate rotational/translational motion limits for patients treated with continuous isocenter localization; (2) retrospectively analyze dosimetric target coverage after daily treatment, and (3) visualize three-dimensional rotations and translations of the prostate with respect to the planned target volume and dose matrix. We present phantom testing and a patient case to validate and demonstrate the utility of this application. Gamma analysis of planar dose computed by our application demonstrated accuracy within 1%/1 mm. Dose computation of a patient treatment revealed high variation in minimum dose to the prostate (D(min)) over 40 fractions and a drop in the D(min) of approximately 8% between a 5 mm and a 3 mm PTV margin plan. The infrastructure has been created for patient-specific treatment evaluation using continuous tracking data. This application can be used to increase confidence in treatment delivery to targets influenced by motion.


Assuntos
Automação/métodos , Campos Eletromagnéticos , Neoplasias da Próstata/radioterapia , Radioterapia/métodos , Automação/instrumentação , Humanos , Masculino , Modelos Biológicos , Movimento (Física) , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Radioterapia/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos , Rotação , Software , Fatores de Tempo
4.
Phys Med Biol ; 54(8): 2541-55, 2009 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-19349658

RESUMO

In their classic paper, Yu et al (1998 Phys. Med. Biol. 43 91) investigated the interplay between tumor motion caused by breathing and dynamically collimated, intensity-modulated radiation delivery. The paper's analytic model assumed an idealized, sinusoidal pattern of motion. In this work, we investigate the effect of tumor motion based on patients' breathing patterns for typical tomotherapy treatments with field widths of 1.0 and 2.5 cm. The measured breathing patterns of 52 lung- and upper-abdominal-cancer patients were used to model a one-dimensional motion. A convolution of the measured beam-dose profiles with the motion model was used to compute the dose-distribution errors, and the positive and negative dose errors were recorded for each simulation. The dose errors increased with increasing motion magnitude, until the motion was similar in magnitude to the field width. For the 1.0 cm and 2.5 cm field widths, the maximum dose-error magnitude exceeded 10% in some simulations, even with breathing-motion magnitudes as small as 5 mm and 10 mm, respectively. Dose errors also increased slightly with increasing couch speed. We propose that the errors were due to subtle drifts in the amplitude and frequency of breathing motion, as well as changes in baseline (exhalation) position, causing both over- and under-dosing of the target. The results of this study highlight potential breathing-motion-induced dose delivery errors in tomotherapy. However, for conventionally fractionated treatments, the dose delivery errors may not be co-located and may average out over many fractions, although this may not be true for hypofractionated treatments.


Assuntos
Movimento , Neoplasias/fisiopatologia , Neoplasias/radioterapia , Radiometria/métodos , Respiração , Humanos , Modelos Biológicos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Fatores de Tempo , Água
5.
Med Phys ; 34(12): 4706-16, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18196798

RESUMO

A novel small animal conformal radiation therapy system has been designed and prototyped: MicroRT. The microRT system integrates multimodality imaging, radiation treatment planning, and conformal radiation therapy that utilizes a clinical 192Ir isotope high dose rate source as the radiation source (teletherapy). A multiparameter dose calculation algorithm based on Monte Carlo dose distribution simulations is used to efficiently and accurately calculate doses for treatment planning purposes. A series of precisely machined tungsten collimators mounted onto a cylindrical collimator assembly is used to provide the radiation beam portals. The current design allows a source-to-target distance range of 1-8 cm at four beam angles: 0 degrees (beam oriented down), 90 degrees, 180 degrees, and 270 degrees. The animal is anesthetized and placed in an immobilization device with built-in fiducial markers and scanned using a computed tomography, magnetic resonance, or positron emission tomography scanner prior to irradiation. Treatment plans using up to four beam orientations are created utilizing a custom treatment planning system-microRTP. A three-axis computer-controlled stage that supports and accurately positions the animals is programmed to place the animal relative to the radiation beams according to the microRTP plan. The microRT system positioning accuracy was found to be submillimeter. The radiation source is guided through one of four catheter channels and placed in line with the tungsten collimators to deliver the conformal radiation treatment. The microRT hardware specifications, the accuracy of the treatment planning and positioning systems, and some typical procedures for radiobiological experiments that can be performed with the microRT device are presented.


Assuntos
Radioisótopos de Irídio/uso terapêutico , Teleterapia por Radioisótopo , Radioterapia Conformacional/instrumentação , Algoritmos , Animais , Simulação por Computador , Camundongos , Método de Monte Carlo , Doses de Radiação , Água
6.
Indian J Malariol ; 32(1): 1-5, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8549834

RESUMO

50 patients (45 males + 5 females) suffering from acute uncomplicated attack of Plasmodium falciparum (Pf) malaria were treated with 1500 mg of halofantrine divided in three doses of 500 mg each given at an interval of 6 h. Results showed there were no primary treatment failures. Average Parasite Clearance Time (av. PCT) was 51.12 h and average Fever Clearance Time (av. FCT) was 31.25 h. Adverse Drug Reactions (ADR) were mild and self limiting. We conclude that halofantrine is a quite safe and effective new antimalarial agent in the treatment of Pf malaria cases.


Assuntos
Antimaláricos/uso terapêutico , Malária Falciparum/tratamento farmacológico , Fenantrenos/uso terapêutico , Doença Aguda , Adolescente , Adulto , Antimaláricos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fenantrenos/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA