Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biotechnol Appl Biochem ; 52(Pt 4): 293-301, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18844606

RESUMO

Endogenous and adventitious virus removal by size-exclusion membrane filtration is a critical dedicated step in an overall viral clearance strategy employed by biologics manufacturers as required by industry regulators. However, the addition of impurities from virus spike preparations used in validation studies can significantly reduce filter capacity, resulting in an oversized and suboptimal virus filtration step. The hydraulic filter performance and virus retention observed in conventional scaled-downed validation models may not necessarily represent performance observed during process development, nor be predictive of manufacturing performance. Using filter flow decay as a relevant processing endpoint, an alternative and more comprehensive approach to virus filter validation has been developed to overcome the limitations imposed by virus spike impurities. With a model feedstream, we have demonstrated comparable virus removal using the conventional virus spiking approach and a complementary preconditioned virus challenge. Similar to a currently accepted method used in the validation of sterilizing-grade filters, this method entails processing non-spiked feed to a volumetric throughput target, followed by processing virus-spiked feed to a final flow decay endpoint to determine viral clearance. This comprehensive approach yields predictive virus retention data under protein-dominant fouling conditions that better model the hydraulic performance of the manufacturing-scale virus filtration operation.


Assuntos
Bacteriófagos/isolamento & purificação , Bacteriófagos/fisiologia , Contaminação de Medicamentos/prevenção & controle , Modelos Biológicos , Ultrafiltração/instrumentação , Ultrafiltração/métodos , Simulação por Computador
2.
PDA J Pharm Sci Technol ; 62(5): 334-43, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19055229

RESUMO

Virus filters are membrane-based devices that remove large viruses (e.g., retroviruses) and/or small viruses (e.g., parvoviruses) from products by a size exclusion mechanism. In 2002, the Parenteral Drug Association (PDA) organized the PDA Virus Filter Task Force to develop a common nomenclature and a standardized test method for classifying and identifying viral-retentive filters. A test method based on bacteriophage PP7 retention was chosen based on developmental studies. The detailed final consensus filter method is published in the 2008 update of PDA Technical Report 41: Virus Filtration. Here, we evaluate the method and find it to be acceptable for testing scaled-down models of small virus-retentive filters from four manufacturers. Three consecutive lots of five filter types were tested (Pegasus SV4, Viresolve NFP, Planova 20N and 15N, Virosart CPV). Each passed the criteria specified in the test method (i.e., >4 log10 PP7 retention, >90% intravenous immunoglobulin passage, and passing integrity/installation testing) and was classified as PP7-LRV4.


Assuntos
Levivirus/isolamento & purificação , Membranas Artificiais , Filtros Microporos , Esterilização/instrumentação , Desenho de Equipamento , Guias como Assunto , Imunoglobulinas Intravenosas/análise , Teste de Materiais , Filtros Microporos/normas , Avaliação de Programas e Projetos de Saúde , Reprodutibilidade dos Testes , Esterilização/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...