Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Clin Radiol ; 77(3): e208-e214, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34887070

RESUMO

AIM: To compare the machine learning computed tomography (CT) quantification tool, Computer-Aided Lung Informatics for Pathology Evaluation and Ratings (CALIPER) to pulmonary function testing (PFT) in assessing idiopathic pulmonary fibrosis (IPF) for patients undergoing treatment and determine the effects of limited (LD) and ultra-low dose (ULD) CT on CALIPER performance. MATERIALS AND METHODS: Thirty-eight IPF patients underwent PFT and standard, LD, and ULD CT. CALIPER classified each CT voxel into either vessel-related structures (VRS), normal, reticular (R), honeycomb (HC) or ground-glass (GG) features. CALIPER-derived interstitial lung disease (ILD) extent represented the sum of GG, R and HC values. Repeated-measures correlation coefficient (ρrm) and 95% confidence interval (CI) evaluated CALIPER features correlation with PFT. Lin's concordance correlation coefficient (CCC) assessed concordance of CALIPER parameters across different CT dosages. RESULTS: Twenty patients completed 12 months of follow-up. CALIPER ILD correlated significantly with percent predicted (%) forced vital capacity (FVC) and forced expiratory volume in 1 second (%FEV1; p=0.004, ρrm -0.343, 95% CI [-0.547, -0.108] and 0.008, -0.321, [-0.518, -0.07], respectively). VRS significantly correlated with %FVC and %FEV1 (p=0.000, ρrm -0.491, 95% CI [-0.685, -0.251] and -0.478, 0.000, [-0.653, -0.231], respectively). There was near perfect LD and moderate ULD concordance with standard dose CT for both ILD (CCC 0.995, 95% CI 0.988-0.999 and 0.9, 0.795-0.983, respectively) and VRS (CCC 0.989, 95% CI 0.963-0.997 and 0.915, 0.806-0.956, respectively). CONCLUSIONS: CALIPER parameters correlate well with PFTs for evaluation of IPF in patients undergoing anti-fibrotic treatment without being influenced by dose variation. CALIPER may serve as a robust, objective adjunct to PFTs in assessing anti-fibrotic treatment related changes.


Assuntos
Fibrose Pulmonar Idiopática/diagnóstico por imagem , Fibrose Pulmonar Idiopática/radioterapia , Aprendizado de Máquina , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Volume Expiratório Forçado , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Capacidade Vital
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA