Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Trauma Acute Care Surg ; 93(2S Suppl 1): S102-S109, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35609333

RESUMO

BACKGROUND: The two approaches to vascularized tissue machine perfusion use either the open (nonpressurized) or closed (pressurized) perfusion system. Most studies describing isolated limb perfusion preservation rely on open perfusion systems and report tissue edema exceeding 40% after 12 to 14 hours of preservation. A variant of machine perfusion places the limb and perfusate into a reservoir closed to atmosphere. It is hypothesized that the reservoir pressure, acting as a transmural pressure, has the advantage of reducing edema formation by counteracting the hydrostatic pressure gradient from the perfusion pressure. This proof-of-concept study aim was to demonstrate feasibility of the Universal Limb Stasis System for Extended Storage (ULiSSES) device (closed, vertical perfusion system) to preserve forelimbs of Sus scrofa swine for 24 hours of subnormothermic perfusion compared with an open, horizontal perfusion system. The ULiSSES is a compact, practical device that applies pulsatile, pressurized perfusion through the novel use of a diaphragm pump powered by compressed oxygen. METHODS: Forelimbs from swine were preserved in ULiSSES device (closed perfusion system) (n = 9) and in an open perfusion system (n = 4) using subnormothermic modified Krebs-Henseleit solution. Physiological parameters were measured at the start and every 3 hours for 24 hours. Limbs were weighed before and after perfusion to compare weight gain. Edema and cellular integrity were evaluated using histopathology pre and post perfusion. RESULTS: Closed perfusion system showed superiority compared with the open perfusion system in terms of oxygen consumption, reduction in vascular resistance, and overall tissue integrity. The closed perfusion system demonstrated a 21% reduction in weight gain compared with the open perfusion system and significantly reduced intracellular edema. CONCLUSION: The ULiSSES closed, pressurized perfusion technology has translatable military applications with the potential to preserve porcine limbs for 24 hours with improved results compared with an open perfusion system.


Assuntos
Circulação Extracorpórea , Preservação de Órgãos , Animais , Preservação de Órgãos/métodos , Perfusão/métodos , Estudo de Prova de Conceito , Aumento de Peso
2.
Steroids ; 75(13-14): 1106-12, 2010 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-20654641

RESUMO

BACKGROUND: The accurate measurement of 25-hydoxy vitamin D (25OH-D) in serum has been a challenge for many years. We developed a liquid chromatography tandem mass spectrometry (LC Tandem MS) assay for the quantitative determination of 25OH-D(2) and 25OH-D(3) in serum. The new method was compared with two widely used commercially available immunoassays. METHODS: Sample preparation involved protein precipitation with acetonitrile containing deuterated forms of the target species as internal standards. An API 5000 mass spectrometer coupled with a photoionization source was used for quantitation. The performance of the new LC Tandem MS assay was compared with a radioimmunoassay (RIA, Diasorin) and a chemiluminescence immunoassay (ECLIA, Roche Diagnostics), analysing serum obtained from 152 individuals. RESULTS: Using 100 µl of serum, the LC Tandem MS assay had a limit of quantitation of 1.3 nmol/L for both 25OH-D(2) and 25OH-D(3) with a linear response between 1.3 and 625 nmol/L and accuracy of between 95 and 124%. Intra- and inter-assay precision were ≤7% and ≤4%, respectively. Measurement of 25OH-D levels in 152 serum samples gave run averages of 71, 56 and 62 nmol/L for LC Tandem MS, ECLIA and RIA, respectively. Correlations between the various methods were: LC Tandem MS vs. RIA: r=0.931; LC Tandem MS vs. ECLIA: r=0.784; RIA vs. ECLIA: r=0.787. The LC Tandem MS method had a positive proportional bias of 26% over the RIA, whereas the ECLIA showed variable differences. CONCLUSION: The new LC Tandem MS assay is accurate and precise at physiologically relevant 25OH-D concentrations, and compares favourably with the RIA. In contrast, the ECLIA shows variable bias with the other assays tested.


Assuntos
25-Hidroxivitamina D 2/sangue , Análise Química do Sangue/métodos , Calcifediol/sangue , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...