Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Cardiovasc Med ; 9: 838473, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35282384

RESUMO

Objective: To analyze if there are sex-related differences in patients with unexplained syncope and bundle branch block (BBB). Background: Despite increasing awareness that sex is a major determinant of the incidence, etiology, and the outcomes of different arrhythmias, no studies have examined differences in presentation and outcomes between men and women with syncope and BBB. Methods: Cohort study of consecutive patients with unexplained syncope and BBB was included from January 2010 to January 2021 with a median follow-up time of 3.4 years [interquartile range (IQR) 1.7-6.0 years]. They were evaluated by a stepwise workup protocol based on electrophysiological study (EPS) and long-term follow-up with an implantable cardiac monitor (ICM). Results: Of the 443 patients included in the study, 165 (37.2%) were women. Compared with men, women had less diabetes (25.5 vs. 39.9%, p = 0.002) and less history of ischemic heart disease (IHD; 13.3 vs. 25.9%, p = 0.002). Left bundle branch block (LBBB) was more frequent in women (55.2 vs. 27.7%, p < 0.001) while right bundle branch block (RBBB) was more frequent in men (41.5 vs. 67.7%, p < 0.001). His to ventricle (HV) interval in the EPS was shorter in women (58 ms [IQR 52-71] vs. 60 ms [IQR 52-73], p = 0.035) and less women had an HV interval longer than 70 ms (28.5 vs. 38.1%, p = 0.039), however, EPS and ICM offered a similar diagnostic yield in both sexes (40.6 vs. 48.9% and 48.4% vs. 51.1%, respectively). Women had a lower risk of developing atrioventricular block (AVB) (adjusted odds ratio [OR] 0.44-95% CI 0.26-0.74, p = 0.002) and of requiring permanent pacemaker implantation (adjusted hazard ratio [HR] 0.72-95% CI: 0.52-0.99, p = 0.046). The mortality rate was lower in women (4.5 per 100 person-years [95% CI 3.1-6.4 per 100 person-years] vs. 7.3 per 100 person-years [95% CI 5.9-9.1 per 100 person-years]). Conclusions: Compared to men, women with unexplained syncope and BBB have a lower risk of AVB and of requiring cardiac pacing. A stepwise diagnostic approach has a similar diagnostic yield in both sexes, and it seems appropriate to guide the treatment and avoid unnecessary pacemaker implantation, especially in women.

3.
Heart Rhythm ; 18(11): 1868-1875, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34098087

RESUMO

BACKGROUND: Three-dimensional (3D) substrate characterization by high-resolution late gadolinium enhancement cardiac magnetic resonance (LE-CMR) is useful for guiding ventricular tachycardia ablation of the left ventricle in ischemic heart disease. OBJECTIVE: The purpose of this study was to validate the substrate characterization and 3D reconstruction of LE-CMR images of the right ventricle (RV) in patients with repaired tetralogy of Fallot (rTOF) and to identify the algorithm that best fits with electroanatomic mapping (EAM). METHODS: RV LE-CMR images were compared with RV EAM in 10 patients with rTOF. RV LE-CMR images were postprocessed and analyzed to identify fibrotic tissue on 3D color maps. The 3D RV substrate reconstructions were created using an adjustable percentage of the maximum voxel signal intensity (MSI) of the scar region to define the threshold between core, transitional zone (TZ), and healthy tissue. Extensions of the core and TZ areas were compared with the scar (<0.5 mV) and low-voltage (0.5-1.5 mV) areas obtained by RV EAM. Agreement on anatomic isthmi identification was quantified. RESULTS: The best match between core and scar was obtained at 65% MSI cutoff (mean areas 17.4 ± 9.9 cm2 vs 16.9 ± 10.0 cm2, respectively; r = 0.954; P <.001). Agreement on anatomic isthmi identification was best at 60% MSI cutoff, which identified 95% of isthmi and achieved a total fit in 90% of patients. CONCLUSION: This study demonstrates that characterization of the RV substrate by postprocessing LE-CMR images in rTOF patients is feasible and validates the technique against RV EAM, which could help in planning target ablation.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Algoritmos , Meios de Contraste , Mapeamento Epicárdico , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...