Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38736248

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) with WATCHMAN currently requires preprocedural imaging, general anesthesia, and inpatient overnight admission. We sought to facilitate simplification of LAAO. AIMS: We describe and compare SOLO-CLOSE (single-operator LAA occlusion utilizing conscious sedation TEE, lack of outpatient pre-imaging, and same-day expedited discharge) with the conventional approach (CA). METHODS: A single-center retrospective analysis of 163 patients undergoing LAAO between January 2017 and April 2022 was conducted. The SOLO-CLOSE protocol was enacted on December 1, 2020. Before this date, we utilized the CA. The primary efficacy endpoint was defined as successful LAAO with ≤5 mm peri-device leak at time of closure. The primary safety endpoint was the composite incidence of all-cause deaths, any cerebrovascular accident (CVA), device embolization, pericardial effusion, or major postprocedure bleeding within 7 days of the index procedure. Procedure times, 7-day readmission rates, and cost analytics were collected as well. RESULTS: Baseline characteristics were similar in both cohorts. Congestive heart failure (37.5% vs. 11.1%) and malignancy (28.8% vs. 12.5%) were higher in SOLO-CLOSE. Median CHA2D2SVASc score was 5 in both cohorts. The primary efficacy endpoint was met 100% in both cohorts. Primary safety endpoint was similar between cohorts (p = 0.078). Mean procedure time was 30 min shorter in SOLO-CLOSE (p < 0.01). Seven-day readmissions for SOLO-CLOSE was zero. After SOLO-CLOSE implementation, there was a 188% increase in positive contribution margin per case. CONCLUSIONS: The SOLO-CLOSE methodology offers similar efficacy and safety when compared to the CA, while improving clinical efficiency, reducing procedural times, and increasing economic benefit.

2.
Eur Heart J Case Rep ; 7(8): ytad339, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37559785

RESUMO

Background: Contemporary procedural guidelines for percutaneous left atrial appendage occlusions (LAAO) with the WATCHMAN device often require the utilization of pre-screening imaging, general anaesthesia, intubation, a dedicated intra-procedural echocardiographer, and overnight observation. For these reasons, LAAO with the WATCHMAN is not economically feasible for many hospital systems. Thus, we sought to evaluate a newstrategy for implantation that may provide a more minimalistic and less cumbersome approach to LAAO. Case summary: We describe five cases utilizing single-operator left atrial appendage occlusion utilizing conscious sedation, transoesophageal echocardiography, lack of outpatient pre-imaging, and same-day expedited discharge (SOLO-CLOSE)-a novel single-operator procedural strategy for LAAO that safely foregoes the aforementioned procedural requirements and allows for same-day early discharge. All five patients were observed according to our newly devised SOLO-CLOSE protocol and were safely discharged home the same day. Follow-up transoesophageal echocardiography (TEE) at 45 days and 1 year revealed well-seated and well-anchored devices with no leaks (<5 mm) or device-related thrombi. Discussion: The SOLO-CLOSE series is the first ever documented WATCHMAN strategy that utilizes a single-operator, TEE-guided, nurse-driven conscious sedation protocol that defers pre-screening imaging and allows for same-day discharge. The versatility of this technique allows proceduralists to comfortably achieve successful LAAO despite a wide range of risk profiles. This single-operator technique has potential to become a widely accepted universal approach for non-pharmacological cardioembolic stroke prophylaxis due to its efficacy, safety, simplicity, and presumable cost-effectiveness.

3.
Eur Heart J Case Rep ; 7(4): ytad160, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37090745

RESUMO

Background: In patients with non-valvular atrial fibrillation, the vast majority of thrombi originate in the left atrial appendage (LAA). Thus, occluding the LAA significantly reduces one's risk for developing an ischaemic stroke. To date, many different surgical methodologies in LAA occlusion (LAAO)/exclusion have been studied and utilized. Unfortunately, patients are often left with incomplete closure of their LAA, leaving behind residual lobes that continue to allow thrombus formations. With the recent rise in percutaneous approaches and devices such as the WATCHMAN FLX, there have been proven success rates in achieving total closure of the LAA. Reports and investigations regarding the utilization of WATCHMAN FLX devices in patients with surgically incomplete LAAO remain limited. Case summary: We present three cases of patients who had previously undergone surgical exclusion of the LAA yet unfortunately were left with residual LAA that continued to place them at high risk for an ischaemic stroke. Percutaneous LAAO with the WATCHMAN FLX was utilized to successfully achieve complete sealing of the residual lobes in failed LAA surgical closures. Discussion: Our multicentre case series elucidates that an increased risk of stroke due to surgical LAAO failure is a real-world possibility that is likely to be encountered in clinical practice. We demonstrate in this series how the WATCHMAN FLX may provide a feasible and safe method to supplement a surgically incomplete LAAO to allow for improved ischaemic stroke and systemic embolization risk reduction.

4.
ESC Heart Fail ; 10(2): 1440-1444, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36480170

RESUMO

Amniotic fluid embolism (AFE) is a rare but potentially fatal complication of pregnancy. Prompt and aggressive resuscitative strategies are crucial in promoting survivability. We present a case of AFE resulting in cardiopulmonary collapse and subsequent cardiac arrest where we were able to safely deliver the baby and resuscitate the mother with veno-arterial extracorporeal membrane oxygenation and Impella CP-a novel combination known as ECPELLA. We discuss the implications of this approach as a more efficacious strategy in resuscitating AFE-induced cardiogenic shock and arrest.


Assuntos
Embolia Amniótica , Oxigenação por Membrana Extracorpórea , Parada Cardíaca , Coração Auxiliar , Gravidez , Feminino , Humanos , Embolia Amniótica/diagnóstico , Embolia Amniótica/terapia , Oxigenação por Membrana Extracorpórea/métodos , Coração Auxiliar/efeitos adversos , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Parada Cardíaca/etiologia , Parada Cardíaca/terapia
5.
JACC Case Rep ; 4(15): 950-954, 2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35935158

RESUMO

Current methodologies of diagnosing and managing venous thoracic outlet syndrome (vTOS) remain controversial, as pertinent studies using modern advancements in medicine are limited. We present a case in which we innovatively used a modified Wright's test during venography coupled with intravascular ultrasound, which allowed us to definitively determine the etiology of a vTOS. (Level of Difficulty: Intermediate.).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...