Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38411177

RESUMO

OBJECTIVES: Even if the topic of the analytical quality required to provide laboratory results "fit for purpose" exists since the beginning of the modern medical laboratory, there is the suspect that the expression "Analytical Performance Specifications" (APS) is not well-known. To investigate this aspect a survey was conducted. METHODS: A questionnaire with seven questions related to the knowledge about the topic, the sources of information and the criteria used by the laboratories to set the APS and their applications was prepared. It was distributed to all the clinical pathology laboratories of Lombardy Region (143) and to the members of SIBioC Laboratory Medicine (excluding Lombardy). RESULTS: We received 201 replies: 127 from Lombardy and 74 from the rest of Italy. Fifteen percent declared to ignore the meaning of APS and only 64 % of those knowing the meaning of the term declared to use them in the daily practice. The state-of-the-art was the principle used more frequently to set APS (about 48 %) followed by biological variation (41 %), and APS were typically applied to set goals for Internal Quality Control for selected measurands. Usually imprecision or total error APS were used, much less frequently uncertainty APS. In fact only 27 % of the laboratories declared to have calculated the measurement uncertainty for part or the majority of their measurands. CONCLUSIONS: Even considering the limits of a survey that relies upon self-declarations, it appears clearly that, at list in Italy, there is some work to be done to promote the concept and the use of APS.

2.
Diagnostics (Basel) ; 12(6)2022 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-35741293

RESUMO

For diagnosing SARS-CoV-2 infection and for monitoring its spread, the implementation of external quality assessment (EQA) schemes is mandatory to assess and ensure a standard quality according to national and international guidelines. Here, we present the results of the 2020, 2021, 2022 EQA schemes in Lombardy region for assessing the quality of the diagnostic laboratories involved in SARS-CoV-2 diagnosis. In the framework of the Quality Assurance Programs (QAPs), the routinely EQA schemes are managed by the regional reference centre for diagnostic laboratories quality (RRC-EQA) of the Lombardy region and are carried out by all the diagnostic laboratories. Three EQA programs were organized: (1) EQA of SARS-CoV-2 nucleic acid detection; (2) EQA of anti-SARS-CoV-2-antibody testing; (3) EQA of SARS-CoV-2 direct antigens detection. The percentage of concordance of 1938 molecular tests carried out within the SARS-CoV-2 nucleic acid detection EQA was 97.7%. The overall concordance of 1875 tests carried out within the anti-SARS-CoV-2 antibody EQA was 93.9% (79.6% for IgM). The overall concordance of 1495 tests carried out within the SARS-CoV-2 direct antigens detection EQA was 85% and it was negatively impacted by the results obtained by the analysis of weak positive samples. In conclusion, the EQA schemes for assessing the accuracy of SARS-CoV-2 diagnosis in the Lombardy region highlighted a suitable reproducibility and reliability of diagnostic assays, despite the heterogeneous landscape of SARS-CoV-2 tests and methods. Laboratory testing based on the detection of viral RNA in respiratory samples can be considered the gold standard for SARS-CoV-2 diagnosis.

3.
Electrophoresis ; 34(6): 818-24, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23334940

RESUMO

Abnormalities in plasma von Willebrand factor (vWF) concentration and function result in von Willebrand disease (vWD). The diagnosis requires a battery of tests such as screening procedures, confirmatory tests, phenotypic characterization, and genotyping. The phenotypic testing (multimer pattern analysis) is important in order to subclassify the hereditary and the acquired forms of vWD. Only few laboratories are skilled to perform this analysis. The extreme range of protein size from 250 kDa monomer to over 20,000 kDa multimers requires a time-consuming procedure (3-4 days) and presents many technical difficulties. To standardize the method and to overcome technical difficulties, we developed a rapid and sensitive semi-automated method to visualize the multimeric structure of vWF. The semi-automated method we present performs the electrophoresis of patient's plasma in 120 min on a precast gel. Gels are suitable for the G26 Interlab instrumentation. After gel blotting, the method allows visualization of the vWF multimer pattern directly on the membrane. We reduced the time required from 72 to 8 h and we propose this test for the first level screening of vWF multimer deficiency.


Assuntos
Automação Laboratorial/métodos , Eletroforese em Gel de Ágar/métodos , Doenças de von Willebrand/diagnóstico , Fator de von Willebrand/análise , Estudos de Casos e Controles , Eletroforese em Gel de Ágar/instrumentação , Eletroforese em Gel de Ágar/normas , Humanos , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...