Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Anal Chim Acta ; 1266: 341324, 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37244657

RESUMO

Size-exclusion chromatography (SEC) employing aqueous mobile phases with volatile salts at neutral pH combined with native mass spectrometry (nMS) is a valuable tool to characterize proteins and protein aggregates in their native state. However, the liquid-phase conditions (high salt concentrations) frequently used in SEC-nMS hinder the analysis of labile protein complexes in the gas phase, necessitating higher desolvation-gas flow and source temperature, leading to protein fragmentation/dissociation. To overcome this issue, we investigated narrow SEC columns (1.0 mm internal diameter, I.D.) operated at 15-µL/min flow rates and their coupling to nMS for the characterization of proteins, protein complexes and higher-order structures (HOS). The reduced flow rate resulted in a significant increase in the protein-ionization efficiency, facilitating the detection of low-abundant impurities and HOS up to 230 kDa (i.e., the upper limit of the Orbitrap-MS instrument used). More-efficient solvent evaporation and lower desolvation energies allowed for softer ionization conditions (e.g., lower gas temperatures), ensuring little or no structural alterations of proteins and their HOS during transfer into the gas phase. Furthermore, ionization suppression by eluent salts was decreased, permitting the use of volatile-salt concentrations up to 400 mM. Band broadening and loss of resolution resulting from the introduction of injection volumes exceeding 3% of the column volume could be circumvented by incorporating an online trap-column containing a mixed-bed ion-exchange (IEX) material. The online IEX-based solid-phase extraction (SPE) or "trap-and-elute" set-up provided on-column focusing (sample preconcentration). This allowed the injection of large sample volumes on the 1-mm I.D. SEC column without compromising the separation. The enhanced sensitivity attained by the micro-flow SEC-MS, along with the on-column focusing achieved by the IEX precolumn, provided picogram detection limits for proteins.


Assuntos
Proteínas , Sais , Espectrometria de Massas/métodos , Cromatografia em Gel , Proteínas/análise , Cromatografia Líquida de Alta Pressão/métodos
3.
J Chromatogr A ; 1688: 463721, 2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36565654

RESUMO

Hydrophilic-interaction liquid chromatography (HILIC) of intact proteins offers high-resolution separations of glycoforms of glycoproteins differing in the number of (neutral) glycans. However, to obtain efficient separations it is essential that the positively charged sites of the proteins are shielded by acidic (negative) ion-pair reagents (IPRs), so as to enhance the contribution of the hydroxyl groups of the (neutral) sugars in the glycoprotein. Here, we studied the influence of various IPRs that differ in physico-chemical properties, such as hydrophobicity and acidity, on the capillary-scale HILIC separation of intact (glyco)proteins. We evaluated the use of fluoroacetic acid (MFA), difluoroacetic acid (DFA), trifluoroacetic acid (TFA), and heptafluorobutyric acid (HFBA) as diluents for sample preparation, as solvents for sample loading on a reversed-phase trap prior to the HILIC separation, and as mobile-phase components for HILIC and HILIC-MS. To reduce the contribution of ion-exchange interaction with the (silica-based) stationary phase, we used an acrylamide-based monolithic column. We studied the influence of the different IPRs on each step of the separation of a mixture of proteins of different size and hydrophilicity and on the separation of the five glycoforms of ribonuclease B. The content of IPR in the sample was shown not to affect the separation and the MS detection. However, a low content of TFA and DFA in the mobile phase is favourable, as it reduces adduct formation and leads to higher signal intensity. The optimized HILIC conditions successfully resolved nine major glycoforms groups of a ∼40 kDa glycoprotein horseradish peroxidase (HRP), as an example of a complex glycoprotein.


Assuntos
Glicoproteínas , Indicadores e Reagentes , Cromatografia Líquida/métodos , Glicoproteínas/química , Espectrometria de Massas , Íons , Interações Hidrofóbicas e Hidrofílicas
4.
Anal Chem ; 94(15): 5909-5917, 2022 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-35380435

RESUMO

SARS-CoV-2 cellular infection is mediated by the heavily glycosylated spike protein. Recombinant versions of the spike protein and the receptor-binding domain (RBD) are necessary for seropositivity assays and can potentially serve as vaccines against viral infection. RBD plays key roles in the spike protein's structure and function, and thus, comprehensive characterization of recombinant RBD is critically important for biopharmaceutical applications. Liquid chromatography coupled to mass spectrometry has been widely used to characterize post-translational modifications in proteins, including glycosylation. Most studies of RBDs were performed at the proteolytic peptide (bottom-up proteomics) or released glycan level because of the technical challenges in resolving highly heterogeneous glycans at the intact protein level. Herein, we evaluated several online separation techniques: (1) C2 reverse-phase liquid chromatography (RPLC), (2) capillary zone electrophoresis (CZE), and (3) acrylamide-based monolithic hydrophilic interaction chromatography (HILIC) to separate intact recombinant RBDs with varying combinations of glycosylations (glycoforms) for top-down mass spectrometry (MS). Within the conditions we explored, the HILIC method was superior to RPLC and CZE at separating RBD glycoforms, which differ significantly in neutral glycan groups. In addition, our top-down analysis readily captured unexpected modifications (e.g., cysteinylation and N-terminal sequence variation) and low abundance, heavily glycosylated proteoforms that may be missed by using glycopeptide data alone. The HILIC top-down MS platform holds great potential in resolving heterogeneous glycoproteins for facile comparison of biosimilars in quality control applications.


Assuntos
Medicamentos Biossimilares , COVID-19 , Cromatografia Líquida , Cromatografia de Fase Reversa/métodos , Glicoproteínas/química , Humanos , Interações Hidrofóbicas e Hidrofílicas , Espectrometria de Massas , Polissacarídeos/análise , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/química
5.
Anal Chem ; 93(48): 16000-16007, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34807576

RESUMO

In this study, we optimized a polymerization mixture to synthesize poly(acrylamide-co-N,N'-methylenebisacrylamide) monolithic stationary phases for hydrophilic-interaction chromatography (HILIC) of intact proteins. Thermal polymerization was performed, and the effects of varying the amount of cross-linker and the porogen composition on the separation performance of the resulting columns were studied. The homogeneity of the structure and the different porosities were examined through scanning electron microscopy (SEM). Further characterization of the monolithic structure revealed a permeable (Kf between 2.5 × 10-15 and 1.40 × 10-13 m2) and polar stationary phase suitable for HILIC. The HILIC separation performance of the different columns was assessed using gradient separation of a sample containing four intact proteins, with the best performing stationary phase exhibiting a peak capacity of 51 in a gradient of 25 min. Polyacrylamide-based materials were compared with a silica-based particulate amide phase (2.7 µm core-shell particles). The monolith has no residual silanol sites and, therefore, fewer sites for ion-exchange interactions with proteins. Thus, it required lower concentrations of ion-pair reagent in HILIC of intact proteins. When using 0.1% of trifluoroacetic acid (TFA), the peak capacities of the two columns were similar (30 and 34 for the monolithic and packed column, respectively). However, when decreasing the concentration of TFA to 0.005%, the monolithic column maintained similar separation performance and selectivity (peak capacity 23), whereas the packed column showed greatly reduced performance (peak capacity 12), lower selectivity, and inability to elute all four reference proteins. Finally, using a mobile phase containing 0.1% formic acid and 0.005% TFA, the HILIC separation on the monolithic column was successfully hyphenated with high-resolution mass spectrometry. Detection sensitivity for protein and glycoproteins was increased and the amount of adducts formed was decreased in comparison with separations performed at 0.1% TFA.


Assuntos
Acrilamidas , Resinas Acrílicas , Cromatografia Líquida , Interações Hidrofóbicas e Hidrofílicas , Espectrometria de Massas , Ácido Trifluoracético
6.
J Chromatogr A ; 1623: 461159, 2020 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-32505275

RESUMO

In the last decade, 3D-printing has emerged as a promising enabling technology in the field of analytical chemistry. Fused-deposition modelling (FDM) is a popular, low-cost and widely accessible technique. In this study, RPLC separations are achieved by in-situ fabrication of porous polymer monoliths, directly within the 3D-printed channels. Thermal polymerization was employed for the fabrication of monolithic columns in optically non-transparent column housings, 3D-printed using two different polypropylene materials. Both acrylate-based and polystyrene-based monoliths were created. Two approaches were used for monolith fabrication, viz. (i) in standard polypropylene (PP) a two-step process was developed, with a radical initiated wall-modification step 2,2'-azobis(2-methylpropionitrile) (AIBN) as the initiator, followed by a polymerization step to generate the monolith; (ii) for glass-reinforced PP (GPP) a silanization step or wall modification preceded the polymerization reaction. The success of wall attachment and the morphology of the monoliths were studied using scanning electron microscopy (SEM), and the permeability of the columns was studied in flow experiments. In both types of housings polystyrene-divinylbenzene (PS-DVB) monoliths were successfully fabricated with good wall attachment. Within the glass-reinforced polypropylene (GPP) printed housing, SEM pictures showed a radially homogenous monolithic structure. The feasibility of performing liquid-chromatographic separations in 3D-printed channels was demonstrated.


Assuntos
Cromatografia de Fase Reversa/métodos , Polipropilenos/química , Impressão Tridimensional , Microscopia Eletrônica de Varredura , Polimerização , Polímeros/química , Poliestirenos/química , Porosidade , Compostos de Vinila/química
7.
Anal Chem ; 92(3): 2589-2596, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-31876153

RESUMO

In this study, we have prepared thermally initiated polymeric monolithic stationary phases within discrete regions of 3D-printed titanium devices. The devices were created with controllable hot and cold regions. The monolithic stationary phases were first locally created in capillaries inserted into the channels of the titanium devices. The homogeneity of the monolith structure and the interface length were studied by scanning a capacitively coupled conductivity contactless detector (C4D) along the length of the capillary. Homogeneous monolithic structures could be obtained within a titanium device equipped with a hot and cold jacket connected to two water baths. The confinement method was optimized in capillaries. The sharpest interfaces (between monolith and empty channel) were obtained with the hot region maintained at 70 °C and the cold region at 4 or 10 °C, with the latter temperature yielding better repeatability. The optimized conditions were used to create monoliths bound directly to the walls of the titanium channels. The fabricated monoliths were successfully used to separate a mixture of four intact proteins using reversed-phase liquid chromatography. Further chromatographic characterization showed a permeability (Kf) of ∼4 × 10-15 m2 and a total porosity of 60%.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...