Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 227
Filtrar
1.
Heliyon ; 10(7): e28539, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38596055

RESUMO

Left atrial (LA) fibrosis plays a vital role as a mediator in the progression of atrial fibrillation. 3D late gadolinium-enhancement (LGE) MRI has been proven effective in identifying LA fibrosis. Image analysis of 3D LA LGE involves manual segmentation of the LA wall, which is both lengthy and challenging. Automated segmentation poses challenges owing to the diverse intensities in data from various vendors, the limited contrast between LA and surrounding tissues, and the intricate anatomical structures of the LA. Current approaches relying on 3D networks are computationally intensive since 3D LGE MRIs and the networks are large. Regarding this issue, most researchers came up with two-stage methods: initially identifying the LA center using a scaled-down version of the MRIs and subsequently cropping the full-resolution MRIs around the LA center for final segmentation. We propose a lightweight transformer-based 3D architecture, Usformer, designed to precisely segment LA volume in a single stage, eliminating error propagation associated with suboptimal two-stage training. The transposed attention facilitates capturing the global context in large 3D volumes without significant computation requirements. Usformer outperforms the state-of-the-art supervised learning methods in terms of accuracy and speed. First, with the smallest Hausdorff Distance (HD) and Average Symmetric Surface Distance (ASSD), it achieved a dice score of 93.1% and 92.0% in the 2018 Atrial Segmentation Challenge and our local institutional dataset, respectively. Second, the number of parameters and computation complexity are largely reduced by 2.8x and 3.8x, respectively. Moreover, Usformer does not require a large dataset. When only 16 labeled MRI scans are used for training, Usformer achieves a 92.1% dice score in the challenge dataset. The proposed Usformer delineates the boundaries of the LA wall relatively accurately, which may assist in the clinical translation of LA LGE for planning catheter ablation of atrial fibrillation.

2.
J Magn Reson Imaging ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38490945

RESUMO

BACKGROUND: Left atrial (LA) myopathy is thought to be associated with silent brain infarctions (SBI) through changes in blood flow hemodynamics leading to thrombogenesis. 4D-flow MRI enables in-vivo hemodynamic quantification in the left atrium (LA) and LA appendage (LAA). PURPOSE: To determine whether LA and LAA hemodynamic and volumetric parameters are associated with SBI. STUDY TYPE: Prospective observational study. POPULATION: A single-site cohort of 125 Participants of the multiethnic study of atherosclerosis (MESA), mean age: 72.3 ± 7.2 years, 56 men. FIELD STRENGTH/SEQUENCE: 1.5T. Cardiac MRI: Cine balanced steady state free precession (bSSFP) and 4D-flow sequences. Brain MRI: T1- and T2-weighted SE and FLAIR. ASSESSMENT: Presence of SBI was determined from brain MRI by neuroradiologists according to routine diagnostic criteria in all participants without a history of stroke based on the MESA database. Minimum and maximum LA volumes and ejection fraction were calculated from bSSFP data. Blood stasis (% of voxels <10 cm/sec) and peak velocity (cm/sec) in the LA and LAA were assessed by a radiologist using an established 4D-flow workflow. STATISTICAL TESTS: Student's t test, Mann-Whitney U test, one-way ANOVA, chi-square test. Multivariable stepwise logistic regression with automatic forward and backward selection. Significance level P < 0.05. RESULTS: 26 (20.8%) had at least one SBI. After Bonferroni correction, participants with SBI were significantly older and had significantly lower peak velocities in the LAA. In multivariable analyses, age (per 10-years) (odds ratio (OR) = 1.99 (95% confidence interval (CI): 1.30-3.04)) and LAA peak velocity (per cm/sec) (OR = 0.87 (95% CI: 0.81-0.93)) were significantly associated with SBI. CONCLUSION: Older age and lower LAA peak velocity were associated with SBI in multivariable analyses whereas volumetric-based measures from cardiac MRI or cardiovascular risk factors were not. Cardiac 4D-flow MRI showed potential to serve as a novel imaging marker for SBI. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

3.
JACC Clin Electrophysiol ; 10(4): 718-730, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38430088

RESUMO

BACKGROUND: Integrating patient-specific cardiac implantable electronic device (CIED)-detected atrial fibrillation (AF) burden with measures of health care cost and utilization allows for an accurate assessment of the AF-related impact on health care use. OBJECTIVES: The goal of this study was to assess the incremental cost of device-recognized AF vs no AF; compare relative costs of paroxysmal atrial fibrillation (pAF), persistent atrial fibrillation (PeAF), and permanent atrial fibrillation (PermAF) AF; and evaluate rates and sources of health care utilization between cohorts. METHODS: Using the de-identified Optum Clinformatics U.S. claims database (2015-2020) linked with the Medtronic CareLink database, CIED patients were identified who transmitted data ≥6 months postimplantation. Annualized per-patient costs in follow-up were analyzed from insurance claims and adjusted to 2020 U.S. dollars. Costs and rates of health care utilization were compared between patients with no AF and those with device-recognized pAF, PeAF, and PermAF. Analyses were adjusted for geographical region, insurance type, CHA2DS2-VASc score, and implantation year. RESULTS: Of 21,391 patients (mean age 72.9 ± 10.9 years; 56.3% male) analyzed, 7,798 (36.5%) had device-recognized AF. The incremental annualized increased cost in those with AF was $12,789 ± $161,749 per patient, driven by increased rates of health care encounters, adverse clinical events associated with AF, and AF-specific interventions. Among those with AF, PeAF was associated with the highest cost, driven by increased rates of inpatient and outpatient hospitalization encounters, heart failure hospitalizations, and AF-specific interventions. CONCLUSIONS: Presence of device-recognized AF was associated with increased health care cost. Among those with AF, patients with PeAF had the highest health care costs. Mechanisms for cost differentials include both disease-specific consequences and physician-directed interventions.


Assuntos
Fibrilação Atrial , Custos de Cuidados de Saúde , Aceitação pelo Paciente de Cuidados de Saúde , Humanos , Fibrilação Atrial/economia , Fibrilação Atrial/terapia , Masculino , Custos de Cuidados de Saúde/estatística & dados numéricos , Feminino , Idoso , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Estados Unidos , Desfibriladores Implantáveis/economia , Desfibriladores Implantáveis/estatística & dados numéricos , Hospitalização/economia , Hospitalização/estatística & dados numéricos , Efeitos Psicossociais da Doença , Idoso de 80 Anos ou mais
4.
Radiol Cardiothorac Imaging ; 6(2): e230148, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451190

RESUMO

Purpose To investigate associations between left atrial volume (LAV) and function with impaired three-dimensional hemodynamics from four-dimensional flow MRI. Materials and Methods A subcohort of participants from the Multi-Ethnic Study of Atherosclerosis from Northwestern University underwent prospective 1.5-T cardiac MRI including whole-heart four-dimensional flow and short-axis cine imaging between 2019 and 2020. Four-dimensional flow MRI analysis included manual three-dimensional segmentations of the LA and LA appendage (LAA), which were used to quantify LA and LAA peak velocity and blood stasis (% voxels < 0.1 m/sec). Short-axis cine data were used to delineate LA contours on all cardiac time points, and the resulting three-dimensional-based LAVs were extracted for calculation of LA emptying fractions (LAEFtotal, LAEFactive, LAEFpassive). Stepwise multivariable linear models were calculated for each flow parameter (LA stasis, LA peak velocity, LAA stasis, LAA peak velocity) to determine associations with LAV and LAEF. Results This study included 158 participants (mean age, 73 years ± 7 [SD]; 83 [52.5%] female and 75 [47.4%] male participants). In multivariable models, a 1-unit increase of LAEFtotal was associated with decreased LA stasis (ß coefficient, -0.47%; P < .001), while increased LAEFactive was associated with increased LA peak velocity (ß coefficient, 0.21 cm/sec; P < .001). Furthermore, increased minimum LAV indexed was most associated with impaired LAA flow (higher LAA stasis [ß coefficient, 0.65%; P < .001] and lower LAA peak velocity [ß coefficient, -0.35 cm/sec; P < .001]). Conclusion Higher minimum LAV and reduced LA function were associated with impaired flow characteristics in the LA and LAA. LAV assessment might therefore be a surrogate measure for LA and LAA flow abnormalities. Keywords: Atherosclerosis, Left Atrial Volume, Left Atrial Blood Flow, 4D Flow MRI Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Aterosclerose , Apêndice Atrial , Feminino , Masculino , Humanos , Idoso , Estudos Prospectivos , Hemodinâmica , Átrios do Coração/diagnóstico por imagem , Aterosclerose/diagnóstico por imagem
5.
Radiol Cardiothorac Imaging ; 6(1): e230107, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38358330

RESUMO

Purpose To achieve ultra-high temporal resolution (approximately 20 msec) in free-breathing, real-time cardiac cine MRI using golden-angle radial sparse parallel (GRASP) reconstruction amplified with view sharing (VS) and k-space-weighted image contrast (KWIC) filtering. Materials and Methods Fourteen pediatric patients with congenital heart disease (mean age [SD], 9 years ± 2; 13 male) and 10 adult patients with arrhythmia (mean age, 62 years ± 8; nine male) who underwent both standard breath-hold cine and free-breathing real-time cine using GRASP were retrospectively identified. To achieve high temporal resolution, each time frame was reconstructed using six radial spokes, corresponding to acceleration factors ranging from 24 to 32. To compensate for loss in spatial resolution resulting from over-regularization in GRASP, VS and KWIC filtering were incorporated. The blur metric, visual image quality scores, and biventricular parameters were compared between clinical and real-time cine images. Results In pediatric patients, the incorporation of VS and KWIC into GRASP (ie, GRASP + VS + KWIC) produced significantly (P < .05) sharper x-y-t (blur metric: 0.36 ± 0.03, 0.41 ± 0.03, 0.48 ± 0.03, respectively) and x-y-f (blur metric: 0.28 ± 0.02, 0.31 ± 0.03, 0.37 ± 0.03, respectively) component images compared with GRASP + VS and conventional GRASP. Only the noise score differed significantly between GRASP + VS + KWIC and clinical cine; all visual scores were above the clinically acceptable (3.0) cutoff point. Biventricular volumetric parameters strongly correlated (R2 > 0.85) between clinical and real-time cine images reconstructed with GRASP + VS + KWIC and were in good agreement (relative error < 6% for all parameters). In adult patients, the visual scores of all categories were significantly lower (P < .05) for clinical cine compared with real-time cine with GRASP + VS + KWIC, except for noise (P = .08). Conclusion Incorporating VS and KWIC filtering into GRASP reconstruction enables ultra-high temporal resolution (approximately 20 msec) without significant loss in spatial resolution. Keywords: Cine, View Sharing, k-Space-weighted Image Contrast Filtering, Radial k-Space, Pediatrics, Arrhythmia, GRASP, Compressed Sensing, Real-Time, Free-Breathing Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Adulto , Humanos , Masculino , Criança , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquipneia , Hiperventilação , Arritmias Cardíacas
7.
J Am Coll Cardiol ; 83(5): 611-631, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38296406

RESUMO

Direct-to-consumer (D2C) wearables are becoming increasingly popular in cardiovascular health management because of their affordability and capability to capture diverse health data. Wearables may enable continuous health care provider-patient partnerships and reduce the volume of episodic clinic-based care (thereby reducing health care costs). However, challenges arise from the unregulated use of these devices, including questionable data reliability, potential misinterpretation of information, unintended psychological impacts, and an influx of clinically nonactionable data that may overburden the health care system. Further, these technologies could exacerbate, rather than mitigate, health disparities. Experience with wearables in atrial fibrillation underscores these challenges. The prevalent use of D2C wearables necessitates a collaborative approach among stakeholders to ensure effective integration into cardiovascular care. Wearables are heralding innovative disease screening, diagnosis, and management paradigms, expanding therapeutic avenues, and anchoring personalized medicine.


Assuntos
Custos de Cuidados de Saúde , Humanos , Reprodutibilidade dos Testes
8.
Am Heart J ; 269: 25-34, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38072334

RESUMO

BACKGROUND: Objective data comparing the diagnostic performance of different ambulatory cardiac monitors (ACMs) are lacking. OBJECTIVES: To assess variation in monitoring strategy, clinical outcomes and healthcare utilization in patients undergoing ambulatory monitoring without a pre-existing arrhythmia diagnosis. METHODS: Using the full sample (100%) of Medicare claims data, we performed a retrospective cohort study of diagnostic-naïve patients who received first-time ACM in 2017 to 2018 and evaluated arrhythmia encounter diagnosis at 3-months, repeat ACM testing at 6 months, all-cause 90-day emergency department (ED) and inpatient utilization, and cost of different strategies: Holter; long-term continuous monitor (LTCM); non-continuous, event-based external ambulatory event monitor (AEM); and mobile cardiac telemetry (MCT). We secondarily performed a device-specific analysis by manufacturer, identified from unique claim modifier codes. RESULTS: ACMs were used in 287,789 patients (AEM = 10.3%; Holter = 53.8%; LTCM = 13.3%; MCT = 22.5%). Device-specific analysis showed that compared to Holter, AEM, MCT, or other LTCM manufacturers, a specific LTCM (ZioⓇ XT 14-day patch, iRhythm Technologies, San Francisco, CA) had the highest adjusted odds of diagnosis and lowest adjusted odds of ACM retesting. Findings were consistent for specific arrhythmia diagnoses of ventricular tachycardia, atrioventricular block, and paroxysmal atrial fibrillation. As a category, LTCM was associated with the lowest 1-year incremental health care expenditures (mean Δ$10,159), followed by Holter ($10,755), AEM ($11,462), and MCT ($12,532). CONCLUSIONS: There was large variation in diagnostic monitoring strategy. A specific LTCM was associated with the highest adjusted odds of a new arrhythmia diagnosis and lowest adjusted odds of repeat ACM testing. LTCM as a category had the lowest incremental acute care utilization. Different monitoring strategies may produce different results with respect to diagnosis and care.


Assuntos
Fibrilação Atrial , Eletrocardiografia Ambulatorial , Metacrilatos , Estados Unidos , Humanos , Idoso , Estudos Retrospectivos , Medicare , Fibrilação Atrial/diagnóstico , Gastos em Saúde , Aceitação pelo Paciente de Cuidados de Saúde
10.
J Am Heart Assoc ; 13(5): e032514, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-37930082

RESUMO

BACKGROUND: The temporal progression states of the molecular and structural substrate in atrial fibrillation (AF) are not well understood. We hypothesized that these can be detected by AF electrograms and magnetic resonance imaging parametric mapping. METHODS AND RESULTS: AF was induced in 43 dogs (25-35 kg, ≥1 year) by rapid atrial pacing (RAP) (3-33 weeks, 600 beats/min), and 4 controls were used. We performed high-resolution epicardial mapping (UnEmap, 6 atrial regions, both atria, 130 electrodes, distance 2.5 mm) and analyzed electrogram cycle length, dominant frequency, organization index, and peak-to-peak bipolar voltage. Implantable telemetry recordings were used to quantify parasympathetic nerve activity over RAP time. Magnetic resonance imaging native T1, postcontrast T1, T2 mapping, and extracellular volume fraction were assessed (1.5T, Siemens) at baseline and AF. In explanted atrial tissue, DNA oxidative damage (8-hydroxy-2'-deoxyguanosine staining) and percentage of fibrofatty tissue were quantified. Cycle length and organization index decreased (R=0.5, P<0.05; and R=0.5, P<0.05; respectively), and dominant frequency increased (R=0.3, P n.s.) until 80 days of RAP but not thereafter. In contrast, voltage continued to decrease throughout the duration of RAP (R=0.6, P<0.05). Parasympathetic nerve activity increased following RAP and plateaued at 80 days. Magnetic resonance imaging native T1 and T2 times increased with RAP days (R=0.5, P<0.05; R=0.6, P<0.05) in the posterior left atrium throughout RAP. Increased RAP days correlated with increasing 8-hydroxy-2'-deoxyguanosine levels and with fibrosis percentage (R=0.5, P<0.05 for both). CONCLUSIONS: A combination of AF electrogram characteristics and T1/T2 magnetic resonance imaging can detect early-stage AF remodeling (autonomic remodeling, oxidative stress) and advanced AF remodeling due to oxidative stress and fibrosis.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Animais , Cães , Fibrilação Atrial/diagnóstico , 8-Hidroxi-2'-Desoxiguanosina , Átrios do Coração/patologia , Imageamento por Ressonância Magnética , Fibrose
12.
Med Image Anal ; 92: 103065, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38113616

RESUMO

4D flow MRI is an emerging imaging modality that maps voxel-wise blood flow information as velocity vector fields that is acquired in 7-dimensional image volumes (3 spatial dimensions + 3 velocity directions + time). Blood flow in the cardiovascular system is often complex and composite involving multiple flow dynamics and patterns (e.g., vortex flow, jets, stagnating flow) that occur and interact simultaneously. The spectrum of such complex flow dynamics is embedded in the velocity vector field dynamics derived from 4D Flow MRI. However, current flow metrics cannot fully measure high-dimensional vector-field data and embedded complex composite flow data. Instead, these methods need to break down the vector-field data into secondary scalar fields of individual flow components using fluid dynamics operators. These methods are gradient-based and sensitive to data uncertainties, and only focus on individual flow components of the overall composite flow, therefore potentially underestimating the severity of overall flow changes associated with cardiovascular diseases. To address these limitations, in MICCAI 2021, we introduced a novel comprehensive stochastic 4D Flow vector-field signature technique that works directly on the entire spatiotemporal velocity vector field. This technique uses efficient stochastic gradient-free interrogation of multi-million flow vector-pairs per patient to derive the patient's unique flow profile of the complex composite flow alterations and in real-time processing. The signature technique's probabilistic gradient-free formulation should allow for highly robust quantification despite inherent errors in 4D flow MRI acquisitions. Here, we extend the application of the 4D flow vector-field signature technique to the left atrium to analyze complex composite flow changes in patients with atrial fibrillation. In 128 subjects, we performed extensive sensitivity testing and determined that the vector-field signature technique is highly robust to typical sources of data uncertainties in 4D flow MRI: degradation in spatiotemporal resolution, added Gaussian noise, and segmentation errors. We demonstrate the excellent generalizability of the stochastic convergence from the aorta to the left atrium and between different 4D Flow MRI acquisition protocols. We compare the robustness of our technique to existing advanced flow quantification metrics of kinetic energy, vorticity, and energy loss demonstrating a superior performance of up-to 14-fold. Our results show the potential diagnostic and clinical utility of our signature technique in identifying distinctly altered composite flow signatures in atrial fibrillation patients independent of existing flow metrics.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento Tridimensional/métodos , Átrios do Coração
13.
Artigo em Inglês | MEDLINE | ID: mdl-37866773

RESUMO

OBJECTIVE: New permanent pacemaker (PPM) implantation after concomitant atrial fibrillation (AF) ablation has been associated with surgical ablation (SA). We sought to determine factors for PPM use as well as early rhythm recovery. METHODS: From 2004 through 2019, 6135 patients underwent valve surgery and were grouped: No AF (n = 4584), AF no SA (n = 346), and AF with SA (n = 1205) to evaluate predischarge PPM and 3-month rhythm recovery (intrinsic heart rate >40 beats per minute). RESULTS: Overall, 282 (4.6%) patients required a predischarge PPM: atrioventricular node dysfunction in 75.3%, sick sinus syndrome in 19.1%, both (5%), and indeterminate (0.7%). Patients with AF had more PPMs: AF with SA (7.9%) versus AF no SA (6.9%) versus No AF (3.6%) (P < .001). For patients with AF, PPM rates were not significantly higher for ablation patients (7.6% SA vs 6.9% AF no SA; P = .56). There were differences in PPM by SA lesion set (biatrial 12.8%; left atrial only 6.1%; pulmonary vein isolation 3.0%; P < .001). Among patients with AF treated with 3-month PPM follow-up, rhythm recovery was common (35 out of 62 [56.5%]) and did not differ by lesion set. Rhythm recovery was seen in 63 out of 141 (44.7%) in the atrioventricular node dysfunction group versus 24 out of 35 (68.6%) in the sick sinus syndrome group (P = .011). In propensity score-matched groups, late survival was similar (P = .63) for new PPM patients. CONCLUSIONS: Avoiding conduction system trauma and delaying implantation reduces the need for postoperative PPM. Rhythm recovery within 3 months is frequent, especially for patients with sick sinus syndrome. A conservative approach to the implantation of a new PPMs is warranted.

14.
Radiol Cardiothorac Imaging ; 5(2): e220133, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37124639

RESUMO

Purpose: To compare maximum left atrial (LA) volume (LAV) from the routinely used biplane area-length (BAL) method with three-dimensional (3D)-based volumetry from late gadolinium-enhanced MRI (3D LGE MRI) and contrast-enhanced MR angiography (3D CE-MRA) in patients with atrial fibrillation (AF). Materials and Methods: Sixty-four patients with AF (mean age, 63 years ± 9 [SD]; 40 male patients) were retrospectively included from a prospective cohort acquired between October 2018 and February 2021. All patients underwent a research MRI examination that included standard two- and four-chamber cine acquisitions, 3D CE-MRA, and 3D LGE MRI performed prior to the atrial kick. Contour delineation on cine imaging and LA 3D segmentations were performed by a radiologist. Maximum LAV (BALmax) was extracted from the BAL volume-time curve and compared with LAV from 3D CE-MRA and 3D LGE MRI. The Kruskal-Wallis test was performed, followed by the Dunn post hoc test and Bland-Altman analyses. Interobserver variability was assessed in 10 patients. Results: BALmax underestimated LAV compared with 3D CE-MRA (bias: -23.5 mL ± 46.2, P < .001) and 3D LGE MRI (bias: -31.3 mL ± 58.3, P < .001), whereas 3D LGE MRI volumes showed no evidence of a difference from 3D CE-MRA (bias: 7.8 mL ± 45.7, P = .38). Interobserver variability yielded excellent agreement for each method (intraclass correlation coefficient, 0.96-0.98). Conclusion: BALmax underestimated LAV in patients with AF compared with 3D LGE MRI and 3D CE-MRA, suggesting that the geometric assumption of an ellipsoidal LA shape in BAL does not reflect LA geometry in patients with AF.Keywords: Left Atrial Volume, Biplane Area-Length, Late Gadolinium-enhanced 3D MRI, Contrast-enhanced 3D MR Angiography, Atrial Fibrillation Supplemental material is available for this article. © RSNA, 2023.

15.
J Cardiovasc Electrophysiol ; 34(5): 1103-1107, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36942773

RESUMO

INTRODUCTION: The Apple watch (AW) irregular rhythm notification (IRN) feature uses photoplethysmography to identify prolonged episodes of irregular rhythm suggestive of atrial fibrillation (AF). IRN is FDA cleared for those with no previous history of AF, however, these devices are increasingly being used for AF management.  The objective of the present study was to determine the accuracy of the IRN in subjects with a previous diagnosis of nonpermanent AF. METHODS: Subjects with a history of nonpermanent AF and either an insertable cardiac monitor (ICM) or cardiac implanted electronic device (CIED) with <5% ventricular pacing were fitted with an AW Series 5 for 6 months. AF episodes were compared between the ICM/CIED and IRN. The primary endpoints were sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the IRN by subject for AF ≥1 h. Secondary endpoints were sensitivity and PPV by AF episode ≥1 h. Analysis was limited to a maximum of 10 ICM/CIED episodes per subject and included only those AF episodes occurring during active AW use confirmed by activity data. RESULTS: Thirty participants were enrolled. Mean age was 65.4 ± 12.2 years and 40% were female. There were 10 ICMs and 20 CIEDs. Eleven subjects had AF on ICM/CIED while the AW was worn, of whom 8 were detected by IRN. There were no false positive IRN detections by subject ("by subject" 72% sensitivity, 100% specificity, 100% PPV, and 90% NPV). Five subjects had AF only when the AW was not worn. There were a total of 70 AF episodes on ICM/CIED, 35 of which occurred while the AW was being worn. Of these, 21 were detected by IRN with 1 false positive ("by episode" sensitivity = 60.0%, PPV = 95.5%). CONCLUSION: In a population with known AF, the AW IRN had a low rate of false positive detections and high specificity. Sensitivity for detection by subject and by AF episode was lower. The current IRN algorithm appears accurate for AF screening as currently cleared, but increased sensitivity and wear times would be necessary for disease management.


Assuntos
Fibrilação Atrial , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Eletrocardiografia Ambulatorial , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Algoritmos
16.
J Interv Card Electrophysiol ; 66(5): 1037-1039, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36735110
17.
JACC Basic Transl Sci ; 8(1): 68-84, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36777167

RESUMO

Traditional anatomically guided ablation and attempts to perform electrogram-guided atrial fibrillation (AF) ablation (CFAE, DF, and FIRM) have not been shown to be sufficient treatment for persistent AF. Using biatrial high-density electrophysiologic mapping in a canine rapid atrial pacing model of AF, we systematically investigated the relationship of electrogram morphology recurrence (EMR) (Rec% and CLR) with established AF electrogram parameters and tissue characteristics. Rec% correlates with stability of rotational activity and with the spatial distribution of parasympathetic nerve fibers. These results have indicated that EMR may therefore be a viable therapeutic target in persistent AF.

18.
J Interv Card Electrophysiol ; 66(8): 1859-1865, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36754907

RESUMO

BACKGROUND: To date, few risk models have been validated to predict recurrent atrial fibrillation (AF) >1 year after ablation. The SCALE-CryoAF score was previously derived to predict very late return of AF (VLRAF) >1 year following cryoballoon ablation (CBA), with strong predictive ability. In this study, we aim to validate the SCALE-CryoAF score for VLRAF after CBA in a novel patient cohort. METHODS: Retrospective analysis of a prospectively maintained single-center database was performed. Inclusion criteria were pulmonary vein isolation using CBA 2017-2020. Exclusion criteria included prior ablation, <1-year follow-up, lack of pre-CBA echocardiogram, additional ablation lesion sets, and documented AF recurrence 90-365 days post-CBA. The area under the curve (AUC) of SCALE-CryoAF was compared to the derivation value and other established risk models. RESULTS: Among 469 CBA performed, 241 (61% male, 62.8 ±11.7 years old) cases were included in analysis. There were 37 (15.4%) patients who developed VLRAF. Patients with VLRAF had a higher SCALE-CryoAF score (VLRAF 5.4 ± 2.7; no VLRAF 3.1 ± 2.9; p<0.001). SCALE-CryoAF was linearly associated with VLRAF (y=14.35x-11.72, R2=0.99), and a score > 5 had a 32.7% risk of VLRAF. The SCALE-CryoAF risk model predicted VLRAF with an AUC of 0.74, which was similar to the derivation value (AUCderivation: 0.73) and statistically superior to MB-LATER, CHA2DS2-VASc, and CHADS2 scores. CONCLUSIONS: The current analysis validates the ability of SCALE-CryoAF to predict VLRAF after CBA in a novel patient cohort. Patients with a high SCALE-CryoAF score should be monitored closely for recurrent AF >1 year following CBA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Risco , Ecocardiografia , Recidiva , Veias Pulmonares/cirurgia
19.
J Cardiovasc Electrophysiol ; 34(10): 2152-2157, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36806796

RESUMO

Uninterrupted anticoagulation for atrial fibrillation (AF), regardless of AF burden, is deeply rooted in practice since the early anticoagulation trials. However, uninterrupted anticoagulation is not without risks, and may not be beneficial for allcomers with a history of AF. Indeed, contemporary data that support a critical duration threshold of AF that benefits from anticoagulation, and a temporal association between stroke and multihour AF episodes, compel the study of a more targeted approach to AF anticoagulation. In this review, we discuss data that support further investigation of "pill in the pocket" anticoagulation for AF, and introduce the pivotal Rhythm Evaluation for Anticoagulation Therapy for Atrial Fibrillation (REACT-AF) trial that will robustly evaluate this strategy.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Anticoagulantes/efeitos adversos
20.
J Cardiovasc Electrophysiol ; 34(3): 502-506, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36640424

RESUMO

INTRODUCTION: Oral sotalol initiation requires a multiple-day, inpatient admission to monitor for QT prolongation during loading. A 1-day intravenous (IV) sotalol loading protocol was approved by the United States Food and Drug Administration in March 2020, but limited data on clinical use and administration currently exists. This study describes implementation of an IV sotalol protocol within an integrated health system, provides initial efficacy and safety outcomes, and examines length of stay (LOS) compared with oral sotalol initiation. METHODS: IV sotalol was administered according to a prespecified initiation protocol to adult patients with refractory atrial or ventricular arrhythmias. Baseline characteristics, safety and feasibility outcomes, and LOS were compared with patients receiving oral sotalol over a similar time period. RESULTS: From January 2021 to June 2022, a total of 29 patients (average age 66.0 ± 8.6 years, 27.6% women) underwent IV sotalol load and 20 patients (average age 60.4 ± 13.9 years, 65.0% women) underwent oral sotalol load. The load was successfully completed in 22/29 (75.9%) patients receiving IV sotalol and 20/20 (100%) of patients receiving oral sotalol, although 7/20 of the oral sotalol patients (35.0%) required dose reduction. Adverse events interrupting IV sotalol infusion included bradycardia (seven patients, 24.1%) and QT prolongation (three patients, 10.3%). No patients receiving IV or oral sotalol developed sustained ventricular arrhythmias before discharge. LOS for patients completing IV load was 2.6 days shorter (mean 1.0 vs. 3.6, p < .001) compared with LOS with oral load. CONCLUSION: IV sotalol loading has a safety profile that is similar to oral sotalol. It significantly shortens hospital LOS, potentially leading to large cost savings.


Assuntos
Síndrome do QT Longo , Sotalol , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Sotalol/efeitos adversos , Antiarrítmicos/uso terapêutico , Tempo de Internação , Estudos de Viabilidade , Arritmias Cardíacas/tratamento farmacológico , Síndrome do QT Longo/induzido quimicamente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...