Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Int J Audiol ; : 1-7, 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37129585

RESUMO

OBJECTIVE: The purpose of this pilot study was to evaluate the magnitude of the medial olivocochlear reflex (MOCR) estimated by the reduction in tone-burst evoked otoacoustic emissions (TBOAEs) measured at three levels and at three frequencies in response to fixed contralateral white noise. Results were compared with commonly used click-evoked otoacoustic emissions (CEOAEs). DESIGN: TBOAEs and CEOAEs, with and without contralateral 60 dB SPL white noise, were measured in response to stimulation at 55, 65, and 75 dB peSPL. In each subject, the set of measurements was performed twice. Of particular interest were the MOCR and its repeatability. STUDY SAMPLE: 15 normally hearing persons (13 women, average age 32.3 years, SD = 8.1). RESULTS: For both CEOAE and TBOAEs, the reliability of the MOCR was much better for broadband measurements than for half-octave-band filtered estimates. At the same time, the reliability of MOCR in half-octave bands was higher for TBOAEs than for CEOAEs, especially at 2 and 4 kHz. CONCLUSIONS: For general applications where broadband MOCR is of interest, the highest magnitude and reliability is provided by CEOAEs. However, TBOAEs may be better if a particular frequency band is of interest.

2.
J Acoust Soc Am ; 152(4): 2150, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36319248

RESUMO

The medial olivocochlear reflex (MOCR), usually assessed by the inhibition of transiently evoked otoacoustic emissions (TEOAEs) with contralateral noise, is a very small effect. In understanding the origin of the MOCR, it is crucial to obtain data of the highest accuracy, i.e., with a high signal-to-noise ratio (SNR), which in turn largely depends on the number of signal averages. This study investigates how the reliability of MOCR measures is affected by the number of averages. At the same time, the effect of the presence of synchronized spontaneous otoacoustic emissions (SSOAEs) is taken into account, as it is known that this factor significantly affects TEOAE amplitudes and SNRs. Each recording session consisted of two series of four measurements, allowing comparison of MOCR magnitude based on 250, 500, 750, and 1000 averages. Reliability was based on comparing the two series. The results show that, for a good quality MOCR measure (i.e., intraclass correlation above 0.9), the required number of averages is at least double that obtainable from a standard TEOAE test (i.e., 500 compared to 250). Ears without SSOAEs needed a higher number of averages to reach a correlation of 0.9 than ears with SSOAEs.


Assuntos
Emissões Otoacústicas Espontâneas , Reflexo , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Estimulação Acústica , Cóclea
3.
Audiol Res ; 12(5): 508-517, 2022 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-36136858

RESUMO

The purpose of the study was to measure the variability of transiently evoked otoacoustic emissions (TEOAEs) and the medial olivocochlear reflex (MOCR) over a long period of time in one person. TEOAEs with and without contralateral acoustic stimulation (CAS) by white noise were measured, from which MOCR strength could be derived as either a dB or % change. In this longitudinal case study, measurements were performed on the right and left ears of a young, normally hearing adult female once a week for 1 year. The results showed that TEOAE level and MOCR strength fluctuated over the year but tended to remain close to a baseline level, with standard deviations of around 0.5 dB and 0.05 dB, respectively. The TEOAE latencies at frequencies from 1 to 4 kHz were relatively stable, with maximum changes ranging from 0.5 ms for the 1 kHz band to 0.08 ms for the 4 kHz band. TEOAE levels and MOCR strengths were strongly and negatively correlated, meaning that the higher the TEOAE level, the lower the MOCR. Additionally, comparison of fluctuations between the ears revealed positive correlation, i.e., the higher the TEOAE level or MOCR in one ear, the higher in the second ear.

4.
Audiol Res ; 12(1): 79-86, 2022 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-35200258

RESUMO

The aim of this study was to compare the reliability of the medial olivocochlear reflex (MOCR) between men and women. The strength of the MOCR was measured in terms of the suppression of transiently evoked otoacoustic emissions (TEOAEs) by contralateral acoustic stimulation (CAS). The difference between TEOAEs with and without CAS (white noise) was calculated as raw decibel TEOAE suppression as well as normalized TEOAE suppression expressed in percent. In each subject, sets of measurements were performed twice. Reliability was evaluated by calculating the intraclass correlation coefficient, the standard error of measurement, and the minimum detectable change (MDC). The study included 40 normally hearing subjects (20 men; 20 women). The estimates of MOCR for both genders were similar. Nevertheless, the reliability of the MOCR was poorer in men, with an MDC around twice that of women. This can be only partially attributed to slightly lower signal-to-noise ratios (SNRs) in men, since we used strict procedures calling for high SNRs (around 20 dB on average). Furthermore, even when we compared subgroups with similar SNRs, there was still lower MOCR reliability in men.

5.
Artigo em Inglês | MEDLINE | ID: mdl-33919574

RESUMO

(1) Background: The purpose of this study was to assess the prevalence of hearing loss in school-age children from rural and urban areas of mid-eastern Poland using standard audiological tests-pure tone audiometry (PTA), impedance audiometry (IA), and otoacoustic emissions (OAEs). (2) Methods: Data were collected from a group of 250 children aged 8 to 13, made up of 122 children from urban areas and 128 children from rural areas of mid-eastern Poland. Hearing was assessed in each of the subjects by means of PTA, IA (tympanometry), and transient-evoked OAEs (TEOAEs). Otoscopy was also performed. (3) Results: There were significantly fewer abnormal results in children from urban than rural areas: they were, respectively, 10.1% and 23.1% for IA, 3% and 9.7% for PTA, and 17.3% and 31.8% for TEOAEs. For hearing-impaired ears in rural areas (failed TEOAE), hearing thresholds were, on average, 11.5 dB higher at 0.5 kHz than for children in urban areas. Comparison of each PTA result with the corresponding IA showed that all cases of hearing loss were related to malfunction of the middle ear. (4) Conclusions: The results of all three hearing tests were significantly worse in children from rural areas compared to those from urban areas. This indicates that audiological healthcare in rural areas needs improvement and that universal hearing screening programs for school-age children would be helpful.


Assuntos
Audição , Emissões Otoacústicas Espontâneas , Adolescente , Audiometria de Tons Puros , Criança , Humanos , Polônia/epidemiologia , Instituições Acadêmicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...