Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 249(9): 1353-7, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21720815

RESUMO

BACKGROUND: The purpose of this paper is to study the differences between central subfield macular thickness (CSMT) measurements obtained by time-domain Stratus optical coherence tomography (OCT) and Cirrus spectral domain OCT (Carl Zeiss Meditec, Dublin, CA) and to formulate an equation to convert CSMT values from one to the other. METHODS: CSMT were measured by both Stratus Macula OCT and Cirrus Macula OCT in 46 healthy subjects. Agreement between measurements was calculated using Lin's concordance coefficient. RESULTS: The average age of our group was 30 with the logMAR visual acuity of -0.015. The Stratus CSMT measurement (mean ± standard deviation) 193.91 ± 21.7 was statistically significant from the Cirrus CSMT measurement 252.82 ± 28.4 (p < 0.001). The transformation equation 0.76×-0.51 from Cirrus to Stratus resulted in values that best agreed with the observed Stratus OCT values. CONCLUSIONS: We identified a significant difference of CSMT measurements between Stratus and Cirrus. The Cirrus typically gave a higher value of CSMT. We derived a linear equation to convert the measurements from Cirrus to Stratus which resulted in transformed values that concord with the observed Stratus OCT values.


Assuntos
Diagnóstico por Computador , Macula Lutea/anatomia & histologia , Erros de Refração/patologia , Tomografia de Coerência Óptica , Adulto , Calibragem/normas , Diagnóstico por Computador/instrumentação , Diagnóstico por Computador/métodos , Diagnóstico por Computador/normas , Feminino , Humanos , Modelos Lineares , Masculino , Valores de Referência , Software , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/normas
2.
J Orthop Res ; 27(6): 701-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19051247

RESUMO

Peri-prosthetic infection remains a serious complication of joint replacement surgery. Herein, we demonstrate that a vancomycin-containing sol-gel film on Ti alloy rods can successfully treat bacterial infections in an animal model. The vancomycin-containing sol-gel films exhibited predictable release kinetics, while significantly inhibiting S. aureus adhesion. When evaluated in a rat osteomyelitis model, microbiological analysis indicated that the vancomycin-containing sol-gel film caused a profound decrease in S. aureus number. Radiologically, while the control side showed extensive bone degradation, including abscesses and an extensive periosteal reaction, rods coated with the vancomycin-containing sol-gel film resulted in minimal signs of infection. MicroCT analysis confirmed the radiological results, while demonstrating that the vancomycin-containing sol-gel film significantly protected dense bone from resorption and minimized remodeling. These results clearly demonstrate that this novel thin sol-gel technology can be used for the targeted delivery of antibiotics for the treatment of periprosthetic as well as other bone infections.


Assuntos
Antibacterianos/farmacocinética , Materiais Revestidos Biocompatíveis , Osteomielite/tratamento farmacológico , Infecções Relacionadas à Prótese/tratamento farmacológico , Vancomicina/farmacocinética , Animais , Densidade Óssea , Pinos Ortopédicos/microbiologia , Reabsorção Óssea/diagnóstico por imagem , Modelos Animais de Doenças , Fêmur/microbiologia , Fêmur/cirurgia , Géis , Osteogênese , Osteomielite/diagnóstico por imagem , Infecções Relacionadas à Prótese/diagnóstico por imagem , Radiografia , Ratos , Infecções Estafilocócicas/diagnóstico por imagem , Infecções Estafilocócicas/tratamento farmacológico , Staphylococcus aureus/efeitos dos fármacos , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...