Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Cardiovasc Imaging ; 29(7): 1537-45, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23925712

RESUMO

Adequate vascular access for femoral trans-catheter aortic valve replacement is fundamental to the success of the procedure. Assessment of vascular calibre, tortuosity and calcification is performed by angiography and multi-slice computed tomography (MSCT). Can DynaCT provide the same information as MSCT? 15 Patients underwent MSCT, angiography and DynaCT. Vessel diameter measurements were taken in three positions of the left and right ilio-femoral arteries. Tortuosity was assessed using an index of the direct distance and the distance taken by the artery between two points. Calcification was assessed in MSCT and DynaCT using a simple scoring system. Concordance correlation coefficient of arterial calibre between angiography and MSCT was 0.96 (95 % CI 0.94-0.97). DynaCT and angiography was 0.94 (95 % CI 0.91-0.96) and Dyna CT and MSCT, 0.95 (95 % CI 0.92-0.97). Bland-Altman tests demonstrate a mean difference between the angiogram and the MSCT of 0.06 mm (+0.97, -1.42), angiogram and DynaCT, 0.13 mm, (+1.00, -0.87), DynaCT and MSCT, 0.2 mm, (+1.15, -0.76). Tortuosity comparisons gave a median tortuosity index for MSCT 1.29 and DynaCT 1.23 (p = 0.472). Calcification comparisons of MSCT and DynaCT using correlation coefficients demonstrate a correlation of 0.245 (p = 0.378). Effective radiation doses were: DynaCT; 3.63 ± 0.65 mSv and angiography; 0.57 ± 0.72 mSv, MSCT; 7.15 ± 2.58 mSv. DynaCT is equal to MSCT and angiography in assessing femoral artery calibre. Like MSCT, it can assess tortuosity and can produce 3D images but is inferior in the assessment of calcification.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco , Artéria Femoral/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/métodos , Artéria Ilíaca/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Seleção de Pacientes , Calcificação Vascular/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Masculino , Valor Preditivo dos Testes , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Índice de Gravidade de Doença
2.
J Med Radiat Sci ; 60(2): 67-70, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26229610

RESUMO

A patient with a medial and posterior dislocation of the right sterno-clavicular (SC) joint and displacement of the trachea and brachiocephalic artery by the medial head of the clavicle underwent general anaesthetic in the operating theatre for an open reduction procedure. The surgeon initially attempted a closed reduction, but this required imaging to check SC alignment. The patient was transferred to an adjacent hybrid operating theatre for imaging. Cone beam computed tomography (CBCT) was performed, which successfully demonstrated a significant reduction in the dislocation of the SC joint. The trachea and brachiocephalic artery were no longer compressed or displaced. This case study demonstrates an alternative to the patient being transferred to the medical imaging department for multi-slice CT. It also describes a novel use of the hybrid operating theatre and its CBCT capabilities.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA