Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Neurotoxicology ; 102: 96-105, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38582332

RESUMO

BACKGROUND: Manganese (Mn) is an essential micronutrient as well as a well-established neurotoxicant. Occupational and environmental exposures may bypass homeostatic regulation and lead to increased systemic Mn levels. Translocation of ultrafine ambient airborne particles via nasal neuronal pathway to olfactory bulb and tract may be an important pathway by which Mn enters the central nervous system. OBJECTIVE: To measure olfactory tract/bulb tissue metal concentrations in Mn-exposed and non-exposed mineworkers. METHODS: Using inductively coupled plasma-mass spectrometry (ICP-MS), we measured and compared tissue metal concentrations in unilateral olfactory tracts/bulbs of 24 Mn-exposed and 17 non-exposed South African mineworkers. We used linear regression to investigate the association between cumulative Mn exposures and olfactory tract/bulb Mn concentration. RESULTS: The difference in mean olfactory tract/bulb Mn concentrations between Mn-exposed and non-Mn exposed mineworkers was 0.16 µg/g (95% CI -0.11, 0.42); but decreased to 0.09 µg/g (95% CI 0.004, 0.18) after exclusion of one influential observation. Olfactory tract/bulb metal concentration and cumulative Mn exposure suggested there may be a positive association; for each mg Mn/m3-year there was a 0.05 µg/g (95% CI 0.01, 0.08) greater olfactory tract/bulb Mn concentration overall, but -0.003 (95% CI -0.02, 0.02) when excluding the three influential observations. Recency of Mn exposure was not associated with olfactory tract/bulb Mn concentration. CONCLUSIONS: Our findings suggest that Mn-exposed mineworkers might have higher olfactory tract/bulb tissue Mn concentrations than non-Mn exposed mineworkers, and that concentrations might depend more on cumulative dose than recency of exposure.

2.
Sci Total Environ ; 922: 171306, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38423310

RESUMO

Exhaust from diesel combustion engines is an important contributor to urban air pollution and poses significant risk to human health. Diesel exhaust contains a chemical class known as nitrated polycyclic aromatic hydrocarbons (nitro-PAHs) and is enriched in 1-nitropyrene (1-NP), which has the potential to serve as a marker of diesel exhaust. The isomeric nitro-PAHs 2-nitropyrene (2-NP) and 2-nitrofluoranthene (2-NFL) are secondary pollutants arising from photochemical oxidation of pyrene and fluoranthene, respectively. Like other important air toxics, there is not extensive monitoring of nitro-PAHs, leading to gaps in knowledge about relative exposures and urban hotspots. Epiphytic moss absorbs water, nutrients, and pollutants from the atmosphere and may hold potential as an effective biomonitor for nitro-PAHs. In this study we investigate the suitability of Orthotrichum lyellii as a biomonitor of diesel exhaust by analyzing samples of the moss for 1-NP, 2-NP, and 2-NFL in the Seattle, WA metropolitan area. Samples were collected from rural parks, urban parks, residential, and commercial/industrial areas (N = 22 locations) and exhibited increasing concentrations across these land types. Sampling and laboratory method performance varied by nitro-PAH, but was generally good. We observed moderate to moderately strong correlation between 1-NP and select geographic variables, including summer normalized difference vegetation index (NDVI) within 250 m (r = -0.88, R2 = 0.77), percent impervious surface within 50 m (r = 0.83, R2 = 0.70), percent high development land use within 500 m (r = 0.77, R2 = 0.60), and distance to nearest secondary and connecting road (r = -0.75, R2 = 0.56). The relationships between 2-NP and 2-NFL and the geographic variables were generally weaker. Our results suggest O. lyellii is a promising biomonitor of diesel exhaust, specifically for 1-NP. To our knowledge this pilot study is the first to evaluate using moss concentrations of nitro-PAHs as biomonitors of diesel exhaust.


Assuntos
Poluentes Atmosféricos , Bryopsida , Poluentes Ambientais , Hidrocarbonetos Policíclicos Aromáticos , Humanos , Emissões de Veículos/análise , Poluentes Atmosféricos/análise , Projetos Piloto , Hidrocarbonetos Policíclicos Aromáticos/análise , Monitoramento Ambiental/métodos
3.
Artigo em Inglês | MEDLINE | ID: mdl-38102301

RESUMO

BACKGROUND: Diesel exhaust (DE) exposures pose concerns for serious health effects, including asthma and lung cancer, in California communities burdened by multiple stressors. OBJECTIVE: To evaluate DE exposures in disproportionately impacted communities using biomonitoring and compare results for adults and children within and between families. METHODS: We recruited 40 families in the San Francisco East Bay area. Two metabolites of 1-nitropyrene (1-NP), a marker for DE exposures, were measured in urine samples from parent-child pairs. For 25 families, we collected single-day spot urine samples during two sampling rounds separated by an average of four months. For the 15 other families, we collected daily spot urine samples over four consecutive days during the two sampling rounds. We also measured 1-NP in household dust and indoor air. Associations between urinary metabolite levels and participant demographics, season, and 1-NP levels in dust and air were evaluated. RESULTS: At least one 1-NP metabolite was present in 96.6% of the urine samples. Detection frequencies for 1-NP in dust and indoor air were 97% and 74%, respectively. Results from random effect models indicated that levels of the 1-NP metabolite 6-hydroxy-1-nitropyrene (6-OHNP) were significantly higher in parents compared with their children (p-value = 0.005). Urinary 1-NP metabolite levels were generally higher during the fall and winter months. Within-subject variability was higher than between-subject variability (~60% of total variance versus ~40%, respectively), indicating high short-term temporal variability. IMPACT: Biomonitoring, coupled with air monitoring, improves understanding of hyperlocal air pollution impacts. Results from these studies will inform the design of effective exposure mitigation strategies in disproportionately affected communities.

4.
Rev Sci Instrum ; 94(10)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37823765

RESUMO

A novel setup for measuring magnetic fields of antiferromagnets (i.e., quadrupolar or higher-order magnetic fields) and generally weakly remanent magnetic materials is presented. The setup features a highly sensitive superconducting quantum interference device magnetometer with a magnetic field resolution of ∼ 10 fT and non-electric temperature control of the sample space for a temperature range of 1.5-65 K with a non-electric sample movement drive and optical position encoding. To minimize magnetic susceptibility effects, the setup components are degaussed and realized with plastic materials in sample proximity. Running the setup in magnetically shielded rooms allows for a well-defined ultra-low magnetic background field well below 150 nT in situ. The setup enables studies of inherently weak magnetic materials, which cannot be measured with high field susceptibility setups, optical methods, or neutron scattering techniques, giving new opportunities for the research on, e.g., spin-spiral multiferroics, skyrmion materials, and spin ices.

7.
J Biosci Bioeng ; 135(6): 493-499, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36966053

RESUMO

Cardiovascular disease, primarily caused by coronary artery disease, is the leading cause of death in the United States. While standard clinical interventions have improved patient outcomes, mortality rates associated with eventual heart failure still represent a clinical challenge. Macrorevascularization techniques inadequately address the microvascular perfusion deficits that persist beyond primary and secondary interventions. In this work, we investigate a photosynthetic oxygen delivery system that rescues the myocardium following acute ischemia. Using a simple microfluidic system, we encapsulated Synechococcus elongatus into alginate hydrogel microparticles (HMPs), which photosynthetically deliver oxygen to ischemic tissue in the absence of blood flow. We demonstrate that HMPs improve the viability of S. elongatus during the injection process and allow for simple oxygen diffusion. Adult male Wistar rats (n = 45) underwent sham surgery, acute ischemia reperfusion surgery, or a chronic ischemia reperfusion surgery, followed by injection of phosphate buffered saline (PBS), S. elongatus suspended in PBS, HMPs, or S. elongatus encapsulated in HMPs. Treatment with S. elongatus-HMPs mitigated cellular apoptosis and improved left ventricular function. Thus, delivery of S. elongatus encapsulated in HMPs improves clinical translation by utilizing a minimally invasive delivery platform that improves S. elongatus viability and enhances the therapeutic benefit of a novel photosynthetic system for the treatment of myocardial ischemia.


Assuntos
Cianobactérias , Hidrogéis , Ratos , Animais , Masculino , Microfluídica , Ratos Wistar , Miocárdio , Oxigênio
8.
J Vasc Access ; : 11297298231153716, 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36765464

RESUMO

INTRODUCTION: Central venous catheters (CVCs) are often trimmed during heart transplantation and pediatric cardiac surgery. However, the risk of endothelial injury caused by the cut tip of the CVC has not been evaluated. We hypothesized that there is no difference in the degree of endothelial injury associated with trimmed CVCs versus standard untrimmed CVCs. METHODS: In four adult male sheep, the left external jugular vein was exposed in three segments, one designated for an untouched control group, one for the trimmed CVC group, and one for the untrimmed CVC group. Trimmed and untrimmed CVC tips were rotated circumferentially within their respective segments to abrade the lumen of the vein. The vein samples were explanted, and two representative sections from each sample were analyzed using hematoxylin and eosin (H&E) staining, as well as with immunohistochemistry against CD31, von Willebrand factor (vWF), endothelial nitric oxide synthase (eNOS), and caveolin. Higher immunohistochemical stain distributions and intensities are associated with normal health and function of the venous endothelium. Data are presented as counts with percentages or as means with standard error. RESULTS: H&E staining revealed no evidence of endothelial injury in 6/8 (75%) samples from the untouched control group, and no injury in 4/8 (50%) samples from both the trimmed and untrimmed CVC groups (p = 0.504). In all remaining samples from each group, only mild endothelial injury was observed. Immunohistochemical analysis comparing trimmed CVCs versus untrimmed CVCs revealed no difference in the percentage of endothelial cells staining positive for CD31 (57.5% ± 7.2% vs 55.0% ± 9.2%, p = 0.982), vWF (73.8% ± 8.0% vs 62.5% ± 9.6%, p = 0.579), eNOS (66.3% ± 4.2% vs 63.8% ± 7.5%, p = 0.962), and caveolin (53.8% ± 5.0% vs 51.3% ± 4.4%, p = 0.922). There were no significant differences between the groups in the distributions of stain intensity for CD31, vWF, eNOS, and caveolin. CONCLUSION: Trimmed CVCs do not increase endothelial injury compared to standard untrimmed CVCs.

9.
Artigo em Inglês | MEDLINE | ID: mdl-36455710

RESUMO

We sought to understand how leaflet forces change in response to annular dilation and leaflet tethering (LT) in single ventricle physiology. Explanted fetal bovine tricuspid valves were sutured onto image-derived annuli and ventricular mounts. Control valves (CON) were secured to a size-matched hypoplastic left heart syndrome (HLHS)-type annulus and compared to: (1) normal tricuspid valves secured to a size-matched saddle-shaped annulus, (2) HLHS-type annulus with LT, (3) HLHS-type annulus with annular dilation (dilation valves), or (4) a combined disease model with both dilation and tethering (disease valves). The specimens were tested in a systemic heart simulator at various single ventricle physiologies. Leaflet forces were measured using optical strain sensors sutured to each leaflet edge. Average force in the anterior leaflet was 43.2% lower in CON compared to normal tricuspid valves (P < 0.001). LT resulted in a 6.6% increase in average forces on the anterior leaflet (P = 0.04), 10.7% increase on the posterior leaflet (P = 0.03), and 14.1% increase on the septal leaflet (P < 0.001). In dilation valves, average septal leaflet forces increased relative to the CON by 42.2% (P = 0.01). In disease valves, average leaflet forces increased by 54.8% in the anterior leaflet (P < 0.001), 37.6% in the posterior leaflet (P = 0.03), and 79.9% in the septal leaflet (P < 0.001). The anterior leaflet experiences the highest forces in the normal tricuspid annulus under single ventricle physiology conditions. Annular dilation resulted in an increase in forces on the septal leaflet and LT resulted in an increase in forces across all 3 leaflets. Annular dilation and LT combined resulted in the largest increase in leaflet forces across all 3 leaflets.

10.
ASAIO J ; 68(10): 1228-1230, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35667305

RESUMO

Infection with the novel coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), may cause viral pneumonia and acute respiratory distress syndrome (ARDS). Treatment of ARDS often requires mechanical ventilation and may take weeks for resolution. In areas with a large outbreaks, there may be shortages of ventilators available. While rudimentary methods for ventilator splitting have been described, given the range of independent ventilatory settings required for each patient, this solution is suboptimal. Here, we describe a device that can split a ventilator among up to four patients while allowing for individualized settings. The device has been validated in vitro and in vivo .


Assuntos
COVID-19 , Pneumonia Viral , Síndrome do Desconforto Respiratório , Humanos , Pneumonia Viral/terapia , Respiração Artificial , Síndrome do Desconforto Respiratório/terapia , SARS-CoV-2 , Ventiladores Mecânicos
11.
J Med Device ; 16(3): 031009, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35646225

RESUMO

Annuloplasty ring choice and design are critical to the long-term efficacy of mitral valve (MV) repair. DynaRing is a selectively compliant annuloplasty ring composed of varying stiffness elastomer segments, a shape-set nitinol core, and a cross diameter filament. The ring provides sufficient stiffness to stabilize a diseased annulus while allowing physiological annular dynamics. Moreover, adjusting elastomer properties provides a mechanism for effectively tuning key MV metrics to specific patients. We evaluate the ring embedded in porcine valves with an ex-vivo left heart simulator and perform a 150 million cycle fatigue test via a custom oscillatory system. We present a patient-specific design approach for determining ring parameters using a finite element model optimization and patient MRI data. Ex-vivo experiment results demonstrate that motion of DynaRing closely matches literature values for healthy annuli. Findings from the patient-specific optimization establish DynaRing's ability to adjust the anterior-posterior and intercommissural diameters and saddle height by up to 8.8%, 5.6%, 19.8%, respectively, and match a wide range of patient data.

12.
Ann Work Expo Health ; 66(8): 985-997, 2022 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-35652799

RESUMO

Wildland firefighters (WLFFs) are exposed to a mixture of chemicals found in wildland fire smoke and emissions from nonwildland-fuel smoke sources such as diesel. We investigated compositional differences in exposure to particulate matter and explored differences in ventilation rate and potential inhaled dose relative to the work tasks of WLFFs. Repeated measures on ten professional and two volunteer firefighters were collected on prescribed burn and nonburn days. Personal monitoring consisted of real-time and gravimetric fine particulate matter (PM2.5), carbon monoxide (CO), and accelerometer measurements to estimate ventilation rate and potential dose of PM2.5. The fine particulate matter was analyzed for levoglucosan (LG) and light absorbing carbon as a surrogate for black carbon (BC). Breathing zone personal exposure concentrations of PM2.5, LG, BC, and CO were higher on burn days (P < 0.05). Differences in exposure concentrations were observed between burn day tasks (P < 0.05) with firefighters managing fire boundaries (holders) being exposed to higher CO and LG concentrations and less BC concentrations than those conducting lighting (lighters). While no statistical difference in PM2.5 exposure measures was observed between the two tasks, holders in the study tended to be exposed to higher PM2.5 concentrations (~1.4×), while lighters tended to have more inhaled amounts of PM2.5 (~1.3×). Our findings demonstrate possible diversity in the sources of particulate matter exposure at the fireline and suggest the potential importance of using dose as a metric of inhalation exposure in occupational or other settings.


Assuntos
Bombeiros , Exposição Ocupacional , Monóxido de Carbono/análise , Humanos , Exposição Ocupacional/análise , Material Particulado , Ventilação Pulmonar , Fumaça
13.
Appl Radiat Isot ; 185: 110237, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35452904

RESUMO

The beta decay of 151Sm was measured by means of a metallic magnetic calorimeter. The measurement and subsequent analysis yielded a beta spectrum with an outstanding high-energy resolution of about 70 eV (FWHM) at 22 keV and a very low energy threshold well below 400 eV. The spectrum exhibited unexpectedly elevated beta emission probabilities at very low energy that we have not been able to reproduce in our theoretical study. The data analysis was thus scrutinized and an independent analysis of the same data set carried out. All new approaches have confirmed the previously found shape of the beta spectrum. The measured spectrum was compared to predictions from an advanced theoretical modeling that includes the atomic exchange effect, precise radiative corrections as well as the realistic nuclear structure that usually plays an important role in first forbidden non-unique transitions. The measured spectrum was then carefully analyzed to determine the maximum beta energy, which was found to be Q = 76.430(68) keV. The dominant beta decay of 151Sm populates the ground state of 151Eu, and a weak beta branch populates the first excited state of 151Eu. From our measurements, the probabilities of these two branches were determined to be 99.31(11)% and 0.69(11)%, respectively.

14.
Front Cardiovasc Med ; 9: 829546, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35355973

RESUMO

Newborn mammals, including piglets, exhibit natural heart regeneration after myocardial infarction (MI) on postnatal day 1 (P1), but this ability is lost by postnatal day 7 (P7). The electrophysiologic properties of this naturally regenerated myocardium have not been examined. We hypothesized that epicardial conduction is preserved after P1 MI in piglets. Yorkshire-Landrace piglets underwent left anterior descending coronary artery ligation at age P1 (n = 6) or P7 (n = 7), After 7 weeks, cardiac magnetic resonance imaging was performed with late gadolinium enhancement for analysis of fibrosis. Epicardial conduction mapping was performed using custom 3D-printed high-resolution mapping arrays. Age- and weight-matched healthy pigs served as controls (n = 6). At the study endpoint, left ventricular (LV) ejection fraction was similar for controls and P1 pigs (46.4 ± 3.0% vs. 40.3 ± 4.9%, p = 0.132), but significantly depressed for P7 pigs (30.2 ± 6.6%, p < 0.001 vs. control). The percentage of LV myocardial volume consisting of fibrotic scar was 1.0 ± 0.4% in controls, 9.9 ± 4.4% in P1 pigs (p = 0.002 vs. control), and 17.3 ± 4.6% in P7 pigs (p < 0.001 vs. control, p = 0.007 vs. P1). Isochrone activation maps and apex activation time were similar between controls and P1 pigs (9.4 ± 1.6 vs. 7.8 ± 0.9 ms, p = 0.649), but significantly prolonged in P7 pigs (21.3 ± 5.1 ms, p < 0.001 vs. control, p < 0.001 vs. P1). Conduction velocity was similar between controls and P1 pigs (1.0 ± 0.2 vs. 1.1 ± 0.4 mm/ms, p = 0.852), but slower in P7 pigs (0.7 ± 0.2 mm/ms, p = 0.129 vs. control, p = 0.052 vs. P1). Overall, our data suggest that epicardial conduction dynamics are conserved in the setting of natural heart regeneration in piglets after P1 MI.

15.
Ann Thorac Surg ; 114(2): 567-571, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35216987

RESUMO

PURPOSE: One major challenge in generating reproducible aortic valve (AV) repair results is the inability to assess AV morphology under physiologic pressure. A transparent intraoperative AV visualization device was designed and manufactured. DESCRIPTION: This device comprises an open proximal end, a cantilevered edge to allow attachment of the device to the aorta or graft, a distal viewing surface, and 2 side ports for fluid delivery and air removal. EVALUATION: The performance of the device was evaluated ex vivo using normal porcine AV in situ (n = 3), porcine AV after valve-sparing aortic root replacement (VSARR) (n = 3), porcine pulmonary valve in the Ross procedure (n = 3), and in 3 patients who underwent VSARR. AV morphology was clearly visualized using the device in all experiments. In human subjects, the use of this device successfully showed cusp prolapse after the initial VSARR and effectively guided additional cusp repair. CONCLUSIONS: This device successfully allows for direct visual assessment of the AV apparatus under physiologic pressure. The use of this device can potentially increase the adoptability of AV repair in clinical practice.


Assuntos
Insuficiência da Valva Aórtica , Procedimentos Cirúrgicos Cardíacos , Animais , Aorta/cirurgia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Suínos , Resultado do Tratamento
16.
BMC Cardiovasc Disord ; 22(1): 73, 2022 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-35219298

RESUMO

BACKGROUND: Mitral annuloplasty rings restore annular dimensions to increase leaflet coaptation, serving a fundamental component in mitral valve repair. However, biomechanical evaluations of annuloplasty rings are lacking. We aim to biomechanically analyze flexible and rigid annuloplasty rings using an ex vivo mitral annular dilation model. METHODS: Juvenile porcine mitral valves (n = 4) with intercommissural distance of 28 mm were dilated to intercommissural distances of 40 mm using a 3D-printed dilator and were sewn to an elastic mount. Fiber bragg grating sensors were anchored to native chordae to measure chordal forces. The valves were repaired using size 28 rigid and flexible annuloplasty rings in a random order. Hemodynamic data, echocardiography, and chordal force measurements were collected. RESULTS: Mitral annular dilation resulted in decreased leaflet coaptation height and increased mitral regurgitation fraction. Both the flexible and rigid annuloplasty rings effectively increased leaflet coaptation height compared to that post dilation. Rigid ring annuloplasty repair significantly decreased the mitral regurgitation fraction. Flexible annuloplasty ring repair reduced the chordal rate of change of force (7.1 ± 4.4 N/s versus 8.6 ± 5.9 N/s, p = 0.02) and peak force (0.6 ± 0.5 N versus 0.7 ± 0.6 N, p = 0.01) compared to that from post dilation. Rigid annuloplasty ring repair was associated with higher chordal rate of change of force (9.8 ± 5.8 N/s, p = 0.0001) and peak force (0.7 ± 0.5 N, p = 0.01) compared to that after flexible ring annuloplasty repair. CONCLUSIONS: Both rigid and flexible annuloplasty rings are effective in increasing mitral leaflet coaptation height. Although the rigid annuloplasty ring was associated with slightly higher chordal stress compared to that of the flexible annuloplasty ring, it was more effective in mitral regurgitation reduction. This study may help direct the design of an optimal annuloplasty ring to further improve patient outcomes.


Assuntos
Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Animais , Dilatação , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Desenho de Prótese , Suínos
17.
J Mech Behav Biomed Mater ; 126: 105074, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35030471

RESUMO

After myocardial infarction (MI), adult mammals exhibit scar formation, adverse left ventricular (LV) remodeling, LV stiffening, and impaired contractility, ultimately resulting in heart failure. Neonatal mammals, however, are capable of natural heart regeneration after MI. We hypothesized that neonatal cardiac regeneration conserves native biaxial LV mechanics after MI. Wistar rat neonates (1 day old, n = 46) and adults (8-10 weeks old, n = 20) underwent sham surgery or permanent left anterior descending coronary artery ligation. At 6 weeks after neonatal MI, Masson's trichrome staining revealed negligible fibrosis. Echocardiography for the neonatal MI (n = 15) and sham rats (n = 14) revealed no differences in LV wall thickness or chamber diameter, and both groups had normal ejection fraction (72.7% vs 77.5%, respectively, p = 0.1946). Biaxial tensile testing revealed similar stress-strain curves along both the circumferential and longitudinal axes across a full range of physiologic stresses and strains. The circumferential modulus (267.9 kPa vs 274.2 kPa, p = 0.7847), longitudinal modulus (269.3 kPa vs 277.1 kPa, p = 0.7435), and maximum shear stress (3.30 kPa vs 3.95 kPa, p = 0.5418) did not differ significantly between the neonatal MI and sham groups, respectively. In contrast, transmural scars were observed at 4 weeks after adult MI. Adult MI hearts (n = 7) exhibited profound LV wall thinning (p < 0.0001), chamber dilation (p = 0.0246), and LV dysfunction (ejection fraction 45.4% vs 79.7%, p < 0.0001) compared to adult sham hearts (n = 7). Adult MI hearts were significantly stiffer than adult sham hearts in both the circumferential (321.5 kPa vs 180.0 kPa, p = 0.0111) and longitudinal axes (315.4 kPa vs 172.3 kPa, p = 0.0173), and also exhibited greater maximum shear stress (14.87 kPa vs 3.23 kPa, p = 0.0162). Our study is the first to show that native biaxial LV mechanics are conserved after neonatal heart regeneration following MI, thus adding biomechanical support for the therapeutic potential of cardiac regeneration in the treatment of ischemic heart disease.


Assuntos
Infarto do Miocárdio , Animais , Animais Recém-Nascidos , Fenômenos Biomecânicos , Cicatriz/patologia , Modelos Animais de Doenças , Infarto do Miocárdio/patologia , Miocárdio/patologia , Ratos , Ratos Wistar , Remodelação Ventricular
18.
Interact Cardiovasc Thorac Surg ; 34(5): 822-830, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35022737

RESUMO

OBJECTIVES: The severity of acute papillary muscle (PM) rupture varies according to the extent and site of the rupture. However, the haemodynamic effects of different rupture variations are still poorly understood. Using a novel ex vivo model, we sought to study acute PM rupture to improve clinical management. METHODS: Using porcine mitral valves (n = 32) mounted within an ex vivo left heart simulator, PM rupture was simulated. The mitral valve was divided into quadrants for analysis according to the PM heads. Acute PM rupture was simulated by incrementally cutting from 1/3 to the total number of chordae arising from 1 PM head of interest. Haemodynamic parameters were measured. RESULTS: Rupture >2/3 of the chordae from 1 given PM head or regurgitation fraction >60% led to markedly deteriorated haemodynamics. Rupture at the anterolateral PM had a stronger negative effect on haemodynamics than rupture at the posteromedial PM. Rupture occurring at the anterior head of the anterolateral PM led to more marked haemodynamic instability than rupture occurring at the other PM heads. CONCLUSIONS: The haemodynamic effects of acute PM rupture vary considerably according to the site and extent of the rupture. Rupture of ≤2/3 of chordae from 1 PM head or rupture at the posteromedial PM lead to less marked haemodynamics effects, suggesting a higher likelihood of tolerating surgery. Rupture at the anterolateral PM, specifically the anterior head, rupture of >2/3 of chordae from 1 PM head or regurgitation fraction >60% led to marked haemodynamic instability, suggesting the potential benefit from bridging strategies prior to surgery.


Assuntos
Cordas Tendinosas , Insuficiência da Valva Mitral , Doença Aguda , Animais , Cordas Tendinosas/cirurgia , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Músculos Papilares/cirurgia , Impressão Tridimensional , Ruptura , Suínos
19.
J Thorac Cardiovasc Surg ; 163(2): e161-e171, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-32747120

RESUMO

OBJECTIVE: The objective was to design and evaluate a clinically relevant, novel ex vivo bicuspid aortic valve model that mimics the most common human phenotype with associated aortic regurgitation. METHODS: Three bovine aortic valves were mounted asymmetrically in a previously validated 3-dimensional-printed left heart simulator. The non-right commissure and the non-left commissure were both shifted slightly toward the left-right commissure, and the left and right coronary cusps were sewn together. The left-right commissure was then detached and reimplanted 10 mm lower than its native height. Free margin shortening was used for valve repair. Hemodynamic status, high-speed videography, and echocardiography data were collected before and after the repair. RESULTS: The bicuspid aortic valve model was successfully produced and repaired. High-speed videography confirmed prolapse of the fused cusp of the baseline bicuspid aortic valve models in diastole. Hemodynamic and pressure data confirmed accurate simulation of diseased conditions with aortic regurgitation and the subsequent repair. Regurgitant fraction postrepair was significantly reduced compared with that at baseline (14.5 ± 4.4% vs 28.6% ± 3.4%; P = .037). There was no change in peak velocity, peak gradient, or mean gradient across the valve pre- versus postrepair: 293.3 ± 18.3 cm/sec versus 325.3 ± 58.2 cm/sec (P = .29), 34.3 ± 4.2 mm Hg versus 43.3 ± 15.4 mm Hg (P = .30), and 11 ± 1 mm Hg versus 9.3 ± 2.5 mm Hg (P = .34), respectively. CONCLUSIONS: An ex vivo bicuspid aortic valve model was designed that recapitulated the most common human phenotype with aortic regurgitation. These valves were successfully repaired, validating its potential for evaluating valve hemodynamics and optimizing surgical repair for bicuspid aortic valves.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Procedimentos Cirúrgicos Cardiovasculares , Modelos Anatômicos , Animais , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/patologia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/patologia , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/cirurgia , Procedimentos Cirúrgicos Cardiovasculares/educação , Procedimentos Cirúrgicos Cardiovasculares/métodos , Bovinos , Ecocardiografia , Hemodinâmica , Humanos
20.
J Thorac Cardiovasc Surg ; 164(6): e389-e405, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34649718

RESUMO

OBJECTIVES: Neonatal rodents and piglets naturally regenerate the injured heart after myocardial infarction. We hypothesized that neonatal rabbits also exhibit natural heart regeneration after myocardial infarction. METHODS: New Zealand white rabbit kits underwent sham surgery or left coronary ligation on postnatal day 1 (n = 94), postnatal day 4 (n = 11), or postnatal day 7 (n = 52). Hearts were explanted 1 day postsurgery to confirm ischemic injury, at 1 week postsurgery to assess cardiomyocyte proliferation, and at 3 weeks postsurgery to assess left ventricular ejection fraction and scar size. Data are presented as mean ± standard deviation. RESULTS: Size of ischemic injury as a percentage of left ventricular area was similar after myocardial infarction on postnatal day 1 versus on postnatal day 7 (42.3% ± 5.4% vs 42.3% ± 4.7%, P = .9984). Echocardiography confirmed severely reduced ejection fraction at 1 day after postnatal day 1 myocardial infarction (33.7% ± 5.3% vs 65.2% ± 5.5% for postnatal day 1 sham, P = .0001), but no difference at 3 weeks after postnatal day 1 myocardial infarction (56.0% ± 4.0% vs 58.0% ± 3.3% for postnatal day 1 sham, P = .2198). Ejection fraction failed to recover after postnatal day 4 myocardial infarction (49.2% ± 1.8% vs 58.5% ± 5.8% for postnatal day 4 sham, P = .0109) and postnatal day 7 myocardial infarction (39.0% ± 7.8% vs 60.2% ± 5.0% for postnatal day 7 sham, P &lt; .0001). At 3 weeks after infarction, fibrotic scar represented 5.3% ± 1.9%, 14.3% ± 4.9%, and 25.4% ± 13.3% of the left ventricle area in the postnatal day 1, postnatal day 4, and postnatal day 7 groups, respectively. An increased proportion of peri-infarct cardiomyocytes expressed Ki67 (15.9% ± 1.8% vs 10.2% ± 0.8%, P = .0039) and aurora B kinase (4.0% ± 0.9% vs 1.5% ± 0.6%, P = .0088) after postnatal day 1 myocardial infarction compared with sham, but no increase was observed after postnatal day 7 myocardial infarction. CONCLUSIONS: A neonatal leporine myocardial infarction model reveals that newborn rabbits are capable of age-dependent natural heart regeneration.


Assuntos
Infarto do Miocárdio , Função Ventricular Esquerda , Animais , Coelhos , Cicatriz , Coração/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Miócitos Cardíacos , Regeneração , Volume Sistólico , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...