Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Cardiol ; 21(10): 769-71, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9789701

RESUMO

This paper reports a patient in atrial flutter who spontaneously converted to sinus rhythm while undergoing a transesophageal echocardiogram. Atrial appendage flow velocities were noted to be significantly decreased after conversion to sinus rhythm. Spontaneous contrast also developed in the left atrium shortly after conversion. Spontaneous cardioversion may be associated with decreased mechanical activity of the left atrium and appendage, resulting in "stunning." This provides a possible explanation for the occurrence of thromboembolic events in patients without apparent thrombus before cardioversion.


Assuntos
Flutter Atrial , Função do Átrio Esquerdo , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Ecocardiografia Transesofagiana , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia Doppler de Pulso
2.
Am Heart J ; 136(4 Pt 1): 724-33, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9778078

RESUMO

BACKGROUND: Accurate identification of patients at high risk for acute coronary syndromes among those seen in the emergency department (ED) with possible myocardial ischemia and nonischemic electrocardiograms is problematic. Both 2-dimensional echocardiography and myocardial perfusion imaging with technetium-99m sestamibi can identify patients at low and high risk; however, comparative studies are lacking. METHODS AND RESULTS: Patients initially considered at low or moderate risk for myocardial ischemia on the basis of the presenting history, physical examination, and electrocardiogram underwent both echocardiography and myocardial perfusion imaging within 4 hours of ED presentation. Positive echocardiography was defined as the presence of segmental wall motion abnormalities or moderate to severe global systolic dysfunction; positive perfusion imaging was defined as a perfusion defect in association with abnormal wall motion, thickening, or both. End points included MI, percutaneous transluminal coronary angioplasty, and positive stress perfusion imaging. Both imaging procedures were performed in the ED on 185 patients. Six patients had MI, and an additional 4 patients underwent percutaneous transluminal coronary angioplasty. Echocardiography and perfusion imaging were positive in all 10. Overall agreement between the 2 techniques was high (concordance 89%, kappa coefficient 0.74) in the 27 patients who had MI or underwent coronary angiography. For all patients, concordance was 89%, with a kappa coefficient of 0.66. CONCLUSIONS: Agreement between echocardiography and perfusion imaging with technetium-99m sestamibi is high when used in patients in the ED with possible myocardial ischemia. Both techniques identified patients at high risk who required admission and those who could be safely discharged directly from the ED.


Assuntos
Ecocardiografia Doppler , Infarto do Miocárdio/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Adulto , Idoso , Fatores de Confusão Epidemiológicos , Ecocardiografia Doppler/métodos , Eletrocardiografia , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Sensibilidade e Especificidade , Virginia
3.
Ann Emerg Med ; 31(5): 550-7, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9581137

RESUMO

STUDY OBJECTIVE: Accurate diagnosis in emergency department patients with possible myocardial ischemia is problematic. Two-dimensional echocardiography has a high sensitivity for identifying patients with myocardial infarction (MI); however, few studies have investigated its diagnostic ability when used acutely in ED patients with possible myocardial ischemia. Therefore we investigated the ability of ED echocardiography for predicting cardiac events in patients with possible myocardial ischemia. METHODS: Echocardiography was performed within 4 hours of ED presentation in 260 patients with possible myocardial ischemia, and was considered positive if there were segmental wall motion abnormalities or the ejection fraction was less than 40%. ECGs were considered abnormal if there was an ST-segment elevation or depression of greater than or equal to 1 mm, or ischemic T-wave inversion. Cardiac events included MI and revascularization. RESULTS: Of the 260 patients studied, 45 had cardiac events (23 MI, 19 percutaneous transluminal angioplasty, 3 coronary bypass surgery). The sensitivity of echocardiography for predicting cardiac events was 91% (95% confidence interval 79% to 97%]), which was significantly higher than the ECG (40% [95% CI 27% to 55%]: P < .0001), although specificity was lower (75% [95% CI 69% to 81%] versus 94% [95% CI 90% to 97%]; P < .001). Addition of the echocardiography results to baseline clinical variables and the ECG added significant incremental diagnostic value (P < .001). With use of multivariate analysis, only male gender (P < .03, odds ratio [OR] 2.4 [1.1 to 5.3]), and a positive echocardiographic finding (P < .0001, OR 24 [9 to 65]) predicted cardiac events. Excluding patients with abnormal ECGs (N = 30) did not affect sensitivity (85%) or specificity (74%) of echocardiography. CONCLUSION: Echocardiography performed in ED patients with possible myocardial ischemia identifies those who will have cardiac events, is more sensitive than the ECG, and has significant incremental value when added to baseline clinical variables and the ECG.


Assuntos
Dor no Peito/etiologia , Isquemia Miocárdica/complicações , Isquemia Miocárdica/diagnóstico por imagem , Idoso , Ecocardiografia/normas , Eletrocardiografia , Serviço Hospitalar de Emergência , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Isquemia Miocárdica/fisiopatologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico , Fatores de Tempo
4.
Cathet Cardiovasc Diagn ; 29(2): 122-7, 1993 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8348596

RESUMO

Dobutamine infusion was performed in 16 patients following cardiac catheterization, and non-invasive assessment was performed with thallium SPECT and echocardiography. Dobutamine thallium scintigraphy was abnormal in 93% of patients with significant coronary artery disease. In addition, individual epicardial vessel involvement was identified by a corresponding perfusion defect with 88% sensitivity and 93% specificity. Dobutamine echocardiography revealed segmental wall motion abnormalities in 62% of patients with significant coronary disease. However, in six patients baseline segmental wall motion abnormalities on echocardiography improved during dobutamine infusion. Dobutamine thallium SPECT is a safe and useful test for the detection and localization of coronary artery disease. Dobutamine echocardiography is less useful in screening for coronary disease, but may detect areas of abnormally functioning myocardium having retained viability.


Assuntos
Doença das Coronárias/diagnóstico , Dobutamina , Ecocardiografia , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Angiografia Coronária , Circulação Coronária/efeitos dos fármacos , Circulação Coronária/fisiologia , Doença das Coronárias/fisiopatologia , Dobutamina/efeitos adversos , Ecocardiografia/efeitos dos fármacos , Teste de Esforço/efeitos dos fármacos , Feminino , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia , Radioisótopos de Tálio
5.
J Am Coll Cardiol ; 7(3): 681-7, 1986 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-3950245

RESUMO

Doppler echocardiographic characteristics of normally functioning Hancock and Björk-Shiley prostheses in the mitral and aortic positions were studied in 50 patients whose valvular function was considered normal by clinical evaluation. Doppler studies were also performed in 46 patients with suspected malfunction of Hancock and Björk-Shiley valves and who subsequently underwent cardiac catheterization. Mean gradients were estimated for both mitral and aortic valve prostheses and valve area was calculated for the mitral prostheses. Doppler prosthetic mitral valve gradient and valve area showed good correlation with values obtained with cardiac catheterization (r = 0.93 and 0.97, respectively) for both types of prosthetic valves. The correlation coefficient (r = 0.93) for mean prosthetic aortic valve gradient was also good, although Doppler echocardiography overestimated the mean gradient at lower degrees of obstruction. Regurgitation of Hancock and Björk-Shiley prostheses in the mitral and aortic positions was correctly diagnosed. These results suggest that Doppler echocardiography is a reliable method for the characterization of normal and abnormal prosthetic valve function.


Assuntos
Bioprótese , Ecocardiografia , Próteses Valvulares Cardíacas , Adulto , Idoso , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Bioprótese/efeitos adversos , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA