Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomed Res Int ; 2017: 5496196, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29349078

RESUMO

Researchers are increasingly attempting to undertake electroencephalography (EEG) recordings in novel environments and contexts outside of the traditional static laboratory setting. The term "mobile EEG," although commonly used to describe many of these undertakings, is ambiguous, since it attempts to encompass a wide range of EEG device mobility, participant mobility, and system specifications used across investigations. To provide quantitative parameters for "mobile EEG," we developed a Categorisation of Mobile EEG (CoME) scheme based upon scoring of device mobility (D, from 0, off-body, to 5, head-mounted with no additional equipment), participant mobility (P, from 0, static, to 5, unconstrained running), system specification (S, from 4, lowest, to 20, highest), and number of channels (C) used. The CoME scheme was applied to twenty-nine published mobile EEG studies. Device mobility scores ranged from 0D to 4D, participant mobility scores from 0P to 4P, and system specification scores from 6S to 17S. The format of the scores for the four parameters is given, for example, as (2D, 4P, 17S, 32C) and readily enables comparisons across studies. Our CoME scheme enables researchers to quantify the degree of device mobility, participant mobility, and system specification used in their "mobile EEG" investigations in a standardised way.


Assuntos
Eletroencefalografia/métodos , Aplicativos Móveis , Monitorização Ambulatorial/métodos , Pesquisa Biomédica , Humanos , Smartphone
2.
Ultrasonics ; 54(2): 502-15, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23993746

RESUMO

A non-linear control method, known as Variable Structure Control (VSC), is employed to reduce the duration of ultrasonic (US) transducer transients. A physically realizable system using a simplified form of the VSC algorithm is proposed for standard piezoelectric transducers and simulated. Results indicate a VSC-controlled transmitter reduces the transient duration to less than a carrier wave cycle. Applications include high capacity ultrasound communication and localization systems.


Assuntos
Algoritmos , Aumento da Imagem/instrumentação , Sistemas Microeletromecânicos/instrumentação , Transdutores , Ultrassonografia/instrumentação , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Retroalimentação , Modelos Teóricos
3.
IEEE Trans Biomed Eng ; 51(10): 1838-44, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15490831

RESUMO

In this paper, we describe the theory and practical implementation of an electrical impedance probe for making in vivo measurements of the electrical admittance of living tissue. The probe uses concentric annular electrodes and is shown to sample a more localized, yet greater, volume of tissue than the standard four-electrode probe. We have developed a mathematical model for the conduction of current between the probe electrodes assuming that we are investigating a uniform, isotropic, semi-infinite region and taking into account the contact impedance between the electrodes and the organ. The electric fields produced by the probe have been calculated by solving a weakly singular Fredholm integral equation of the second kind. The size and position of the probe electrodes have been optimized to maximize both the accuracy in the admittance measurement and insensitivity to contact impedance. A probe and driving hardware have been constructed and experimental results are provided showing the accuracy of admittance measurements at 50 and 640 KHz.


Assuntos
Desenho Assistido por Computador , Tecido Conjuntivo/fisiologia , Impedância Elétrica , Eletrodos , Análise de Falha de Equipamento , Modelos Biológicos , Transdutores , Vísceras/fisiologia , Simulação por Computador , Campos Eletromagnéticos , Desenho de Equipamento/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA