Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Int Urol Nephrol ; 56(6): 1983-1986, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38340262

RESUMO

Inspired by the Stewart-Figge acid-base approach, Gattinoni et al. recently introduced a new internal milieu parameter known as alactic base excess (ABE). The authors defined ABE as the sum of lactate and standard base excess. In the context of sepsis, ABE has been proposed as a valuable marker to discern between metabolic acidosis resulting from the accumulation of lactate and the retention of fixed acids, which can occur in cases of renal failure. Multiple studies have demonstrated that a negative ABE value (<-3 mmol/L) represents an early marker of renal dysfunction, and significantly correlates with higher mortality rates in septic patients. In conclusion, ABE is a simple and useful parameter that can be used to better interpret a patient's acid-base status, assess renal function, and general prognosis in sepsis. By incorporating ABE into clinical practice, healthcare professionals can enhance their understanding of the complex acid-base imbalances in their patients and tailor more individualized, effective treatment plans.


Assuntos
Equilíbrio Ácido-Base , Desequilíbrio Ácido-Base , Sepse , Humanos , Ácido Láctico/sangue , Acidose/diagnóstico , Biomarcadores/sangue , Prognóstico , Relevância Clínica
2.
Eur J Pediatr ; 183(3): 1037-1045, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38085280

RESUMO

Point-of-care ultrasound (POCUS) has been established as an essential bedside tool for real-time image guidance of invasive procedures in critically ill neonates and children. While procedural guidance using POCUS has become the standard of care across many adult medicine subspecialties, its use has more recently gained popularity in neonatal and pediatric medicine due in part to improvement in technology and integration of POCUS into physician training programs. With increasing use, emerging data have supported its adoption and shown improvement in pediatric outcomes. Procedures that have traditionally relied on physical landmarks, such as thoracentesis and lumbar puncture, can now be performed under direct visualization using POCUS, increasing success, and reducing complications in our most vulnerable patients. In this review, we describe a global and comprehensive use of POCUS to assist all steps of different non-vascular invasive procedures and the evidence base to support such approach. CONCLUSION: There has been a recent growth of supportive evidence for using point-of-care ultrasound to guide neonatal and pediatric percutaneous procedural interventions. A global and comprehensive approach for the use of point-of-care ultrasound allows to assist all steps of different, non-vascular, invasive procedures. WHAT IS KNOWN: • Point-of-care ultrasound has been established as a powerful tool providing for real-time image guidance of invasive procedures in critically ill neonates and children and allowing to increase both safety and success. WHAT IS NEW: • A global and comprehensive use of point-of-care ultrasound allows to assist all steps of different, non-vascular, invasive procedures: from diagnosis to semi-quantitative assessment, and from real-time puncture to follow-up.


Assuntos
Estado Terminal , Sistemas Automatizados de Assistência Junto ao Leito , Recém-Nascido , Adulto , Humanos , Criança , Estado Terminal/terapia , Testes Imediatos , Ultrassonografia/métodos , Previsões
3.
J Perinatol ; 41(7): 1645-1650, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33795791

RESUMO

OBJECTIVE: To assess the ability of point-of-care ultrasound (POCUS) to identify venous cannula position in neonates on extracorporeal membrane oxygenation (ECMO) and compare with conventional imaging. STUDY DESIGN: Retrospective review of 37 infants on ECMO with 51 POCUS studies between January 2017 and October 2019. Studies were reviewed for identification of venous cannula location and compared with plain radiography and echocardiography. Kappa statistic and predictive values were calculated. RESULTS: Venous cannula tip position was identified in 90% of POCUS studies. Fifty percent of the cannula tips were malpositioned. Plain radiography, the most commonly used method for evaluating tip position, showed poor agreement (57%) with POCUS (kappa 0.13). There was substantial agreement (89%) between echocardiography and POCUS (kappa 0.78). CONCLUSION: This study provides preliminary evidence that POCUS is more accurate than plain radiography for the evaluation of ECMO venous cannula position. Adoption of this practice may prevent potentially catastrophic ECMO complications.


Assuntos
Oxigenação por Membrana Extracorpórea , Cânula , Humanos , Lactente , Recém-Nascido , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Retrospectivos , Ultrassonografia
4.
J Thromb Haemost ; 18(12): 3352-3358, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32979018

RESUMO

BACKGROUND: Extreme thrombocytosis (EXT, platelet count > 1000 × 103 /µL) is an uncommon but potentially clinically significant finding. Primary EXT in the setting of myeloproliferative disorders is linked to thrombotic and/or bleeding complications more frequently than secondary EXT, which typically occurs in reaction to infection, inflammation, or iron deficiency. However, comorbidities have been reported in adults with secondary EXT. Clinical implications of EXT in children are not well defined, as prior studies targeted small and/or specialized pediatric populations. OBJECTIVES: Our objectives were to determine etiologies and sequelae of EXT in a hospitalized general pediatric patient population. PATIENTS AND METHODS: We retrospectively analyzed EXT cases from a single-center pediatric cohort of ~80 000 patients over 8 years. RESULTS: Virtually all cases (99.8%) were secondary in nature, and most were multifactorial. Many cases of EXT occurred in children under 2 years old (47%) and/or during critical illness (55%). No thrombotic or bleeding events directly resulted from EXT, confirming a paucity of clinical complications associated with EXT in pediatric patients. There were indications that neonatal hematopoiesis and individual genetic variation influenced some cases, in addition to certain diagnoses (eg, sickle cell anemia) and clinical contexts (eg, asplenia). CONCLUSION: Our findings confirm that thrombotic events related to EXT are rare in pediatric patients, which can inform the use of empiric anti-platelet therapy.


Assuntos
Transtornos Mieloproliferativos , Trombocitose , Adulto , Criança , Estado Terminal , Humanos , Lactente , Recém-Nascido , Contagem de Plaquetas , Estudos Retrospectivos , Trombocitose/diagnóstico , Trombocitose/epidemiologia
5.
Cardiol Young ; 27(1): 59-68, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28281411

RESUMO

BACKGROUND: Fontan survivors have depressed cardiac index that worsens over time. Serum biomarker measurement is minimally invasive, rapid, widely available, and may be useful for serial monitoring. The purpose of this study was to identify biomarkers that correlate with lower cardiac index in Fontan patients. Methods and results This study was a multi-centre case series assessing the correlations between biomarkers and cardiac magnetic resonance-derived cardiac index in Fontan patients ⩾6 years of age with biochemical and haematopoietic biomarkers obtained ±12 months from cardiac magnetic resonance. Medical history and biomarker values were obtained by chart review. Spearman's Rank correlation assessed associations between biomarker z-scores and cardiac index. Biomarkers with significant correlations had receiver operating characteristic curves and area under the curve estimated. In total, 97 cardiac magnetic resonances in 87 patients met inclusion criteria: median age at cardiac magnetic resonance was 15 (6-33) years. Significant correlations were found between cardiac index and total alkaline phosphatase (-0.26, p=0.04), estimated creatinine clearance (0.26, p=0.02), and mean corpuscular volume (-0.32, p<0.01). Area under the curve for the three individual biomarkers was 0.63-0.69. Area under the curve for the three-biomarker panel was 0.75. Comparison of cardiac index above and below the receiver operating characteristic curve-identified cut-off points revealed significant differences for each biomarker (p<0.01) and for the composite panel [median cardiac index for higher-risk group=2.17 L/minute/m2 versus lower-risk group=2.96 L/minute/m2, (p<0.01)]. CONCLUSIONS: Higher total alkaline phosphatase and mean corpuscular volume as well as lower estimated creatinine clearance identify Fontan patients with lower cardiac index. Using biomarkers to monitor haemodynamics and organ-specific effects warrants prospective investigation.


Assuntos
Biomarcadores/sangue , Débito Cardíaco/fisiologia , Técnica de Fontan/métodos , Cardiopatias Congênitas/sangue , Monitorização Fisiológica/métodos , Adolescente , Adulto , Criança , Feminino , Seguimentos , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Prognóstico , Estudos Prospectivos , Curva ROC , Adulto Jovem
6.
J Pediatr ; 167(2): 325-30.e1, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26033368

RESUMO

OBJECTIVES: To determine the cardiovascular effects of obesity on patients with tetralogy of Fallot (TOF) repair. STUDY DESIGN: Ventricular performance measures were compared between obese (body mass index [BMI] ≥95%), overweight (85% ≤BMI <95%), and normal weight subjects (BMI <85%) in a retrospective review of patients with TOF who underwent cardiac magnetic resonance from 2005-2010. Significance was P < .05. RESULTS: Of 260 consecutive patients with TOF, 32 were obese (12.3%), 48 were overweight (18.5%), and 180 were normal weight (69.2%). Biventricular mass was increased in obese compared with normal weight patients with right ventricular mass more affected than left ventricular mass. Obese patients demonstrated decreased biventricular end-diastolic volume (EDV) and stroke volume (SV) when indexed to body surface area (BSA) with an increased heart rate when compared with normal weight patients; cardiac index, ejection fraction, and pulmonary regurgitation fraction were similar. When indexed to ideal BSA, biventricular EDV and SV were similar. EDV and SV for overweight patients were nearly identical to normal weight patients with ventricular mass in between the other 2 groups. CONCLUSIONS: Approximately 12% of patients after TOF repair referred for cardiac magnetic resonance in a tertiary referral center are obese with increased biventricular mass. Obese patients and normal weight patients have similar cardiac indices, however, when indexed to actual BSA, obese patients demonstrate decreased EDV and SV with increased heart rate and similar cardiac indices. When indexed to ideal BSA, no differences in biventricular volumes were noted.


Assuntos
Frequência Cardíaca/fisiologia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Obesidade/complicações , Volume Sistólico/fisiologia , Tetralogia de Fallot/cirurgia , Adolescente , Índice de Massa Corporal , Criança , Pré-Escolar , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Obesidade/epidemiologia , Obesidade/fisiopatologia , Prevalência , Estudos Retrospectivos , Tetralogia de Fallot/complicações , Tetralogia de Fallot/fisiopatologia , Função Ventricular/fisiologia
7.
J Am Coll Cardiol ; 60(12): 1094-102, 2012 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-22974693

RESUMO

OBJECTIVES: This study investigated whether cardiac magnetic resonance (CMR) and echocardiography (echo) can replace catheterization (cath) for routine evaluation prior to Fontan and under what circumstances CMR and cath are used together. BACKGROUND: Routine cath prior to Fontan has been utilized for years; noninvasive methods, however, may be sufficient. METHODS: This study reviews clinical data in 119 consecutive patients investigating 3 groups: those who underwent CMR alone (MR; n = 41), cath alone (C; n = 41), or both cath and CMR (C+M; n = 37) prior to Fontan. RESULTS: No clinically significant differences were noted in patient characteristics, hemodynamics, or clinical status prior to or after surgery between the C and MR groups. CMR added information in 82%. There were no discrepant findings between CMR and cath data in the C+M group. Diagnostic success was ≥95% in all groups. Of those undergoing Fontan completion, the C+M group had similar outcomes to C and MR; C and CMR were utilized in combination to assess aortopulmonary collaterals or the need for an intervention or evaluate its success. Echo could not delineate pulmonary arterial anatomy in 46% to 53% of patients. The C+M and C groups were exposed to 6.8 ± 4.1 mSv of radiation. CONCLUSIONS: Single ventricle patients not requiring an intervention can undergo successful Fontan completion with CMR and echo alone with similar short-term outcomes to C, which was used as a control, preventing an invasive test and exposure to radiation. CMR can add information in a significant number of patients. Cath and CMR are utilized together for interventions and assessment of aortopulmonary collaterals.


Assuntos
Cateterismo Cardíaco/normas , Técnica de Fontan , Ventrículos do Coração/anormalidades , Imagem Cinética por Ressonância Magnética/normas , Cuidados Pré-Operatórios/normas , Cateterismo Cardíaco/métodos , Pré-Escolar , Feminino , Técnica de Fontan/métodos , Ventrículos do Coração/patologia , Humanos , Lactente , Recém-Nascido , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Cuidados Pré-Operatórios/métodos
8.
J Biomed Opt ; 17(3): 037007, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22502579

RESUMO

Diffuse correlation spectroscopy (DCS) is a novel optical technique that appears to be an excellent tool for assessing cerebral blood flow in a continuous and non-invasive manner at the bedside. We present new clinical validation of the DCS methodology by demonstrating strong agreement between DCS indices of relative cerebral blood flow and indices based on phase-encoded velocity mapping magnetic resonance imaging (VENC MRI) of relative blood flow in the jugular veins and superior vena cava. Data were acquired from 46 children with single ventricle cardiac lesions during a hypercapnia intervention. Significant increases in cerebral blood flow, measured both by DCS and by VENC MRI, as well as significant increases in oxyhemoglobin concentration, and total hemoglobin concentration, were observed during hypercapnia. Comparison of blood flow changes measured by VENC MRI in the jugular veins and by DCS revealed a strong linear relationship, R=0.88, p<0.001, slope=0.91±0.07. Similar correlations were observed between DCS and VENC MRI in the superior vena cava, R=0.77, slope=0.99±0.12, p<0.001. The relationship between VENC MRI in the aorta and DCS, a negative control, was weakly correlated, R=0.46, slope=1.77±0.45, p<0.001.


Assuntos
Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos , Análise Espectral/métodos , Aorta/fisiologia , Gasometria , Dióxido de Carbono/sangue , Pré-Escolar , Difusão , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Hipercapnia/fisiopatologia , Lactente , Veias Jugulares/fisiologia , Modelos Lineares , Masculino , Oxiemoglobinas/química , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Veia Cava Superior/fisiologia
9.
Am J Cardiol ; 108(1): 120-5, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21679782

RESUMO

The present project investigated whether cardiac magnetic resonance (CMR) of aortic arch anomalies can be performed successfully in infants <6 months of age without the use of cardiac anesthesia or deep sedation. We performed a retrospective review of infants ≤6 months old from 2005 to 2009 who underwent either CMR or computed tomography angiography to investigate aortic arch abnormalities. The CMR procedure used a "feed and swaddle" protocol without deep sedation or cardiac anesthesia. Of the 52 infants referred for CMR, 24 underwent the feed and swaddle protocol (aged 2.6 ± 1.4 months). One patient awoke during the study, and examination of the remaining 23 yielded a definitive diagnosis (success rate 96%). The scanning time was 6.2 ± 3.1 minutes, with the large airways evaluation accounting for 1/2 the time. Single-shot axial steady-state free precession, in which the definitive diagnosis was made, accounted for 0.59 ± 0.3 minutes. Fifteen infants were diagnosed with a vascular ring. Of the 8 infants who underwent surgery, the diagnostic accuracy was 100%. During the same period, 19 patients, who had undergone computed tomography angiography (aged 1.67 ± 1.20 months), were referred for aortic arch evaluation. Of these 19 patients, 6 (32%) underwent sedation or anesthesia. The imaging time was 0.08 ± 0.06 minutes, significantly different from the CMR times (p <0.01). However, the overall room times (31.3 ± 22.3 and 35.8 ± 3.86 minutes, respectively) were not different between the CMR and angiographic groups. The radiation dose was 1.41 ± 1.03 mSv. In conclusion, CMR evaluation of aortic arch anomalies in children <6 months old can be successfully completed quickly using a feed and swaddle approach with high diagnostic accuracy. This protocol avoids the risks of sedation, as well as the radiation associated with computed tomography angiography.


Assuntos
Anestesia , Angiografia/métodos , Aorta Torácica/anormalidades , Sedação Consciente , Imagem Cinética por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Malformações Vasculares/diagnóstico , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Diagnóstico Diferencial , Seguimentos , Humanos , Lactente , Recém-Nascido , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...