Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Reprod Domest Anim ; 45(5): e199-200, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19788524

RESUMO

In this study, two unusual presentations of canine prostatitis are described; in the first case a 10-years-old neutered Boxer dog was presented to the Veterinary Teaching Hospital of the University of Extremadura with a complaint of anorexia, apathy and preputial discharge. In the second case, a local veterinarian referred an 8-years-old male Labrador to the Veterinary Teaching Hospital of the University of Extremadura. The dog had a history of pain in the caudal abdomen and preputial oedema. The final diagnosis in both cases was acute prostatitis. It is concluded that although canine prostatitis is a common disease, sometimes can have presentations that may differ from those classically described in the literature.


Assuntos
Doenças do Cão/patologia , Orquiectomia/veterinária , Prostatite/veterinária , Infecções Estreptocócicas/veterinária , Inibidores de 5-alfa Redutase/uso terapêutico , Animais , Antibacterianos/uso terapêutico , Cães , Enrofloxacina , Antagonistas de Estrogênios/uso terapêutico , Finasterida/uso terapêutico , Fluoroquinolonas/uso terapêutico , Masculino , Prostatite/patologia , Infecções Estreptocócicas/tratamento farmacológico , Tamoxifeno/uso terapêutico
2.
Rev. esp. med. nucl. (Ed. impr.) ; 23(6): 387-393, nov. 2004. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-147807

RESUMO

Objetivo: Evaluar el efecto de la corrección de atenuación y de dispersión (CA-CS) sobre la exactitud diagnóstica de la SPET de perfusión miocárdica (PMI) postesfuerzo. Material y métodos: Se analizaron de forma retrospectiva 121 pacientes en los que se practicó una SPET de PMI postesfuerzo con Tetrofosmina-Tc99m sin corrección (NC) y con CA-CS. El ventrículo izquierdo fue dividido en 13 segmentos. Dos observadores realizaron un análisis visual de la PMI en cada segmento siguiendo una escala del 0 (defecto de captación) al 3 (normal). Se estableció un consenso acerca de las coincidencias y discrepancias entre las imágenes NC y CA-CS. El diagnóstico definitivo de enfermedad coronaria (EC) se estableció por la coronariografía (CANG) (estenosis 70 %). Resultados: El análisis de las imágenes NC y CA-CS produjo 93 coincidencias y 28 discrepancias. Ambos estudios fueron anormales en 67 de las 93 coincidencias (CANG anormal en 57) y normales en 26 (CANG normal en 20). Las 28 discrepancias fueron 23 NC anormal/CA-CS normal (CANG normal en 18) y 5 NC normal/CA-CS anormal. En estos 5 pacientes la CA-CS generó defectos de perfusión en cara anterior pero la CANG fue normal. Globalmente, los resultados de las imágenes NC y CA-CS coincidieron con la CANG en el 72% (87/121) y 78 % (95/121) de los pacientes respectivamente. De los 90 pacientes con NC anormales, 67 tenían CA-CS anormales (CANG anormal en 57) y 23 CA-CS normales (CANG normal en 18). Por tanto la imagen CA-CS coincidió con los hallazgos de la CANG en el 83 % (75/90) de los pacientes con NC patológicas. Las alteraciones de PMI en NC normalizadas por la CA-CS se localizaron preferentemente en la cara inferior. Conclusión: La aplicación de la CA-CS mejora la exactitud diagnóstica de la SPET NC de PMI postesfuerzo en el diagnóstico de la EC. Con estos resultados consideramos que la CA-CS tiene valor clínico en la corrección de los artefactos por atenuación que observamos con más frecuencia en la cara inferior. La aparición en las imágenes CA-CS de defectos de perfusión antero-apicales con imágenes NC normales no significa significa EC. Por ello es necesario ajustar el patrón de normalidad de la SPET de PMI cuando se trabaja con CA-CS (AU)


Objective: To evaluate the effect of attenuation and scatter correction (AC-SC) on the diagnostic accuracy of post-stress myocardial perfusion (MP) SPECT. Material and methods: The retrospective analysis included 121 patients who had a non-corrected (NC) and AC-SC 99mTc- Tetrofosmin MP SPECT after stress. The left ventricle was divided into 13 segments. Two observers performed a visual assessment of the MP on a scale from 0 (perfusion defect) to 3 (normal uptake). A consensus on concordances and discordances between the NC and AC-SC images was established. Final diagnosis of coronary artery disease (CAD) was established by coronary angiography (CANG) (stenosis 70%). Results: The combined analysis of NC and AC-SC images produced 93 concordances and 28 discordances. Of the 93 concordances, both studies were abnormal in 67 patients (abnormal CANG in 57) and normal in 26 patients (normal CANG in 20). Among the 28 discordances, 23 were abnormal NC/normal AC-SC (normal CANG in 18) and 5 normal NC/abnormal AC-SC. In these 5 patients AC-SC generated anterior perfusion defects but the CANG was normal. Overall, the appearance of NC and AC-SC images were in agreement with the CANG findings in the 72 % (87/121) and 78 % (95/121) of the patients, respectively. Sixty-seven of the 90 patients with abnormal NC had also abnormal AC-SC (abnormal CANG in 57) and the other 23 had normal AC-SC (normal CANG in 18). The appearance of AC-SC was in agreement with CANG finding in the 83 % (75/90) of patients with abnormal NC. MP abnormalities in NC normalized by AC-SC were more frequently located in inferior wall Conclusion: AC-SC improves the diagnostic accuracy of post stress NC MP SPECT for the diagnosis of CAD. From these results we consider that AC-SC is of clinical value for the correction of attenuation artifacts, more frequently observed in the inferior wall. The presence of antero-apical perfusion defects in AC-SC with normal NC does not mean CAD. So it is necessary to adjust the normalcy pattern of MP SPECT when AC-SC is performed (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana , Tomografia Computadorizada de Emissão de Fóton Único , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Teste de Esforço , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Rev. esp. med. nucl. (Ed. impr.) ; 23(1): 15-21, ene. 2004.
Artigo em Es | IBECS | ID: ibc-29326

RESUMO

La eficacia de los algoritmos de reconstrucción es un factor importante a fin de garantizar la calidad de imágenes tomográficas de Medicina Nuclear. Existen dos grupos de algoritmos, los analíticos y los de carácter estadístico. El algoritmo de Retroproyección Filtrada (RPF) pertenece al primer grupo mientras que Ordered Subsets Expectation Maximization (OSEM) es uno de los algoritmos del segundo grupo.El objetivo del presente trabajo fue comparar ambos algoritmos utilizando la Transformada Wavelet (TW). Se eligió este instrumento dada su capacidad de separar la imagen en distintos niveles de frecuencia sin perder información posicional de los mismos. La misma se aplicó con base Haar y sin decimación por niveles, a fin de poder comparar matrices de igual tamaño. Se prestó atención a la presencia relativa de tres perturbaciones típicas: el ruido de Poisson, los artificios anulares que expresan una deficiente corrección de la uniformidad planar y el fenómeno de la atenuación.Con este propósito se estudiaron cortes transversales homólogos de distribuciones homogéneas de actividad. Se comprobó, que el algoritmo OSEM no solamente introduce importantes mejoras, en cuanto a filtrar el ruido de Poisson, sino que también disminuye los artificios anulares, en particular en la zona de la imagen coincidente con el centro de rotación. El fenómeno de la atenuación, para el caso de estas imágenes, mostró igual intensidad con ambos algoritmos a excepción de la zona periférica donde OSEM produjo un aumento aparente de la concentración de actividad ligeramente más importante que RPF.Estas observaciones alientan el interés de continuar en la idea de utilizar la TW no sólo para identificar, sino también para tratar de disminuir la presencia de artificios característicos de éstas imágenes (AU)


Assuntos
Tomografia Computadorizada de Emissão de Fóton Único , Imagens de Fantasmas
4.
Rev. esp. med. nucl. (Ed. impr.) ; 21(6): 417-425, nov. 2002.
Artigo em Es | IBECS | ID: ibc-17459

RESUMO

FUNDAMENTO Y OBJETIVOS: Este trabajo pretende conocer la prevalencia de infección por Francisella tularensis en la población de Castilla y León previa al brote de tularemia humana de finales de 1997. SUJETOS Y MÉTODO: Se obtuvieron 4.825 sueros (entre abril de 1996 y abril de 1997) de residentes en Castilla y León. Se realizó una prueba de microaglutinación en placa para detectar anticuerpos anti-F. tularensis. En los sueros positivos se llevaron a cabo seroaglutinaciones en tubo frente a Brucella, Yersinia enterocolitica y Proteus. RESULTADOS: Se detectaron anticuerpos anti-F.tularensis en 9 (0,19 per cent) de los 4.825 sueros.De esos 9 sueros, uno fue positivo en la seroaglutinación frente a Brucella, siendo todos negativos frente a las otras bacterias. CONCLUSIONES: Antes de 1997 la seroprevalencia de anticuerpos anti-F. tularensis en la población de Castilla y León era baja (0,19 per cent).... (AU)


Assuntos
Pessoa de Meia-Idade , Adulto , Masculino , Feminino , Humanos , Tomografia Computadorizada de Emissão de Fóton Único , Artefatos , Espalhamento de Radiação , Variações Dependentes do Observador , Compostos Radiofarmacêuticos , Isquemia Miocárdica , Tecnécio Tc 99m Sestamibi , Glândulas Paratireoides , Valores de Referência , Mama , Processamento de Imagem Assistida por Computador , Reações Falso-Positivas , Motilidade Gastrointestinal , Coração , Septos Cardíacos
5.
Rev. esp. med. nucl. (Ed. impr.) ; 20(5): 377-385, ago. 2001.
Artigo em Es | IBECS | ID: ibc-778

RESUMO

Se presenta un tumor óseo localizado en el 6º arco costal derecho cuya imagen en la gammagrafía ósea fue de una lesión hipercaptadora única. Aunque la radiografía de tórax y la TAC fueron normales, en la RMN se observó una lesión hipointensa en secuencias T1 e hipertensa en T2.El diagnóstico histológico postcirugía fue de osteoblastoma. Se realiza una revisión sobre el significado clínico de las lesiones costales únicas que aparecen hipercaptadoras en la gammagrafía ósea. El osteoblastoma debe de ser considerado cuando se realiza un diagnóstico diferencial de las lesiones costales únicas que aparecen en la gammagrafía ósea (AU)


Assuntos
Pessoa de Meia-Idade , Feminino , Humanos , Costelas , Osteoblastoma , Diagnóstico Diferencial , Imageamento por Ressonância Magnética , Síndrome de Tietze , Neoplasias Ósseas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...