Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultraschall Med ; 2024 Mar 21.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-38513687

RESUMO

Simulation-based training (SBT) is increasingly acknowledged worldwide and has become a popular tool for ultrasound education. Ultrasound simulation involves the use of technology and software to create a virtual training setting. Simulation-based training allows healthcare professionals to learn, practice, and improve their ultrasound imaging skills in a safe learning-based environment. SBT can provide a realistic and focused learning experience that creates a deep and immersive understanding of the complexity of ultrasound, including enhancing knowledge and confidence in specific areas of interest. Abdominal ultrasound simulation is a tool to increase patient safety and can be a cost-efficient training method. In this paper, we provide an overview of various types of abdominal ultrasound simulators, and the benefits, and challenges of SBT. We also provide examples of how to develop SBT programs and learning strategies including mastery learning. In conclusion, the growing demand for medical imaging increases the need for healthcare professionals to start using ultrasound simulators in order to keep up with the rising standards.

2.
Healthcare (Basel) ; 11(20)2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37893809

RESUMO

(1) Background: This study aims to comprehensively understand the motivations driving radiographers in five Arab countries to engage in research. (2) Methods: A cross-sectional study employing an anonymous online survey was conducted for 12 weeks from May to July 2023. The study sample consisted of 250 radiographers, with equal representation from Iraq, the Kingdom of Saudi Arabia, Palestine, Sudan, and the United Arab Emirates. (3) Results: Overall, the participants showed limited involvement in research-related activities in all five countries, particularly in presenting at conferences and publishing in peer-reviewed journals. Most participants believed research positively impacts their professional development (34.8%) and patient care and outcomes (40%). The participants perceived professional development (36.4%) as a key motivator for research engagement. A significant majority (81.6%) expressed motivation to start research in clinical practice. A total of 66.8% found research opportunities available during clinical practice. Barriers included time constraints (56%), limited resources (47.2%), and lack of support and skills (33.2% and 32%, respectively). (4) Conclusion: This study emphasises the need for targeted strategies to enhance research engagement among radiographers in the Arab region. Addressing barriers, such as time constraints and resource limitations, while leveraging intrinsic motivators, such as professional development, is crucial for fostering a culture of research-driven excellence in radiography.

3.
J Med Imaging Radiat Sci ; 54(4): 692-698, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37838500

RESUMO

BACKGROUND: Ultrasonography measurement of the testicles and subsequent calculation of the testicular volume is recommended as a part of a standard scrotal ultrasound examination. The interobserver variability of testicular volume measurement has implications for surgical recommendations. Therefore, this study aimed to investigate the interobserver variability in the measurement of testicular volume. METHODS: Interobserver variability was established by comparing testicular measurements performed by two observers on the same patient during the same clinical appointment. The observers were blinded to each other's measurements. Testicular volume was calculated using the Lambert formula: length x width x height x 0.71. A total of three observers, A, B and C, participated in the study. The observers had between 4 to 20 years' experience with scrotal ultrasound examinations. RESULTS: In total, 24 patients' were included (48 testicles). The patient´s mean age was 43 years (range 19-75 years). The overall mean right testicular volume was 19.8 ml (range 7.3-31.6 ml), and the left was 20.1 ml (range 7.1-36.1 ml). The interclass correlation coefficient (ICC) between observer A and B was excellent (ICC= 0.98, CI:0.92-0.99), between observer A and C, was excellent (ICC=0.91, CI: 0.77-0.97) and between B and C good (ICC=0.82, CI:0.51-0.93). CONCLUSION: Variability in estimating testicular volume is low, with interobserver agreement ranging from good to excellent. Ultrasound provides a highly reproducible tool to determine testicular volume.


Assuntos
Testículo , Masculino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Variações Dependentes do Observador , Ultrassonografia , Testículo/diagnóstico por imagem
4.
J Clin Imaging Sci ; 13: 39, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38205276

RESUMO

Objectives: Computed tomography (CT) of the wrist may be challenged, due to patients' inability to extend the arm for a "Superman pose" resulting in increased radiation dose due to scatter. Alternative positions and less dose administering modalities such as 3D Cone-beam CT (CBCT) and single-shot CT could be considered. This phantom study aimed to estimate scatter radiation dose in different phantom positions using helical and single-shot CT and 3D CBCT. Material and Methods: Wireless electronic dosimeters attached to the head and chest of an anthropomorphic phantom in various clinically relevant positions were used to measure scatter radiation. In helical CT, the following positions were used: Superman pose, semi-superman pose, wrist on the abdomen, and single-shot CT with the patient sitting in front of and behind the gantry. In 3D CBCT, the phantom was in a supine position with the arm extended laterally. Results: Helical CT using the Superman pose resulted in a total scattered radiation dose of 64.8 µGy. The highest total dose (269.7 µGy) was obtained with the wrist positioned on the abdomen while the lowest total dose was achieved in single-shot CT with the phantom sitting behind the gantry with the forearm placed inside the gantry (3.2 µGy). The total dose in 3D CBCT was 171.1 µGy. Conclusion: The commonly used semi-superman and wrist-on-abdomen positions in CT administer the highest scattered doses and should be avoided when either single-shot CT or 3D CBCT is available. Radiographers should carefully consider alternatives when a patient referred for wrist CT cannot comply with the Superman position.

5.
Cancers (Basel) ; 16(1)2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38201571

RESUMO

PURPOSE: To assess the use of quantitative diffusion-weighted MRI (DW-MRI) as a diagnostic imaging biomarker in differentiating between benign colon adenoma, early, and advanced cancer of the colon, as well as predicting lymph node involvement, and finally comparing mucinous-producing colon cancer with adenomas and non-mucinous colon cancer. METHOD: Patients with a confirmed tumor on colonoscopy were eligible for inclusion in this study. Using a 3.0 Tesla MRI machine, the main tumor mean apparent diffusion coefficient (mADC) was obtained. Surgically resected tumor specimens served as an endpoint, except in mucinous colon cancers, which were classified based on T2 images. RESULTS: A total of 152 patients were included in the study population. The mean age was 71 years. A statistically significant mADC mean difference of -282 × 10-6 mm2/s [-419--144 95% CI, p < 0.001] was found between colon adenomas and early colon cancer, with an AUC of 0.80 [0.68-0.93 95% CI] and an optimal cut off value of 1018 × 10-6 mm2/s. Only a small statistically significant difference (p = 0.039) in mADC was found between benign tumors and mucinous colon cancer. We found no statistical difference in mADC mean values between early and advanced colon cancer, and between colon cancer with and without lymph node involvement. CONCLUSION: Quantitative DW-MRI is potentially useful for determining whether a colonic tumor is benign or malignant. Mucinous colon cancer shows less diffusion restriction when compared to non-mucinous colon cancer, a potential pitfall.

6.
Diagnostics (Basel) ; 12(9)2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36140566

RESUMO

Purpose: To investigate the diagnostic performance of endorectal ultrasound (ERUS), shear-wave elastography (SWE), and magnetic resonance imaging (MRI) in patients with a complex rectal adenoma or an early rectal cancer, i.e., T1 or T2 adenocarcinoma in a clinical setting, and to evaluate the association between SWE and stromal fraction (SF) and apparent diffusion coefficient (ADC) and SF. Method: This prospective study included patients undergoing ERUS and SWE for a rectal tumor subsequently confirmed by histopathology to be an adenoma or a T1 or T2 adenocarcinoma. The accuracy of the imaging methods was assessed by comparing the T category as determined by ERUS and MRI with histopathology, which served as the gold standard. SF was assessed on surgical specimens. Results: A total of 86 patients were included. Of these, 62 patients had adenomas and 24 patients had carcinomas, of which 11 were T1 tumors and 13 were T2 tumors. ERUS and MRI yielded sensitivity, specificity, and accuracy of 0.79 and 0.73, 0.95 and 0.90, and 0.86 and 0.78, respectively, for discrimination between benign and malignant lesions. The area under the receiver operating characteristics curve for SWE was 0.88, and with a cut-off value of 40 kPa the sensitivity, specificity, and accuracy were 0.79, 0.89, and 0.86, respectively. There was a positive correlation between SF and SWE with a p-value of <0.001 and a negative correlation between SF and ADC with a p-value of 0.011. Conclusion: Both ERUS and MRI classified T categories with a high accuracy; however, ERUS classified more adenomas correctly than MRI. In this small population, SWE could differentiate an adenoma from early carcinoma. SF was correlated with both SWE and ADC, as increasing SF tended to yield higher SWE and lower ADC values.

7.
Cancers (Basel) ; 14(11)2022 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-35681613

RESUMO

BACKGROUND: Endorectal ultrasound (ERUS) is an important tool when evaluating complex rectal adenomas and rectal cancer, and the accuracy is improved by adding elastography measurements. A high interobserver agreement is imperative in clinical practice. Therefore, the aim of this study was to evaluate interobserver agreement assessed on real-time images. Additionally, we investigated the intra- and interobserver agreement between experienced and inexperienced observers. MATERIALS AND METHODS: We prospectively included patients referred to an ERUS at the Department of Radiology with a complex rectal polyp or suspected rectal malignancy. Two operators independently scanned each patient in turn. Furthermore, four observers assessed previously obtained images using three different methods for placing the region of interest (ROI). Three months later, the four observers reassessed the images to assess intraobserver variability. RESULTS: A total of 19 patients were included for live assessment. Agreement of tumor classification was substantial for T stage (kappa: 0.86) and fair for N stage (kappa: 0.73), with an absolute agreement for T and N stages of 84% and 89%, respectively. Agreement of SWE was good for Emean (ICC 0.94, 95% CI 0.86-0.98) and fair for Emax (ICC 0.85, 95% CI 0.66-0.94). Intra- and interobserver agreement between inexperienced and experienced observers showed good to excellent agreement with all ROI methods. CONCLUSION: Interobserver agreement is high in SWE when performed in a clinical setting. We found the best agreement using the mean value of several ROIs. Intra- and interobserver agreement was high regardless of operator experience.

8.
Cancers (Basel) ; 14(11)2022 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-35681783

RESUMO

Background: Colorectal cancer is the second most common cancer worldwide. The sigmoid takeoff is the landmark where the colon sigmoid curves toward the sacrum viewed from sagittal magnetic resonance imaging (MRI). The purpose of this study was to assess interobserver variability in the assessment of the anal verge and anorectal junction in patients diagnosed with rectal cancer on magnetic resonance imaging (MRI). Materials and Methods: The rectal MRI examinations were performed using a 1.5- or 3.0-tesla unit using an anterior coil and a standard scan protocol. Two senior radiologists assessed MRI scans from patients under investigation for rectal cancer. The two observers assessed the anal verge and takeoff in cm independently. Difference in agreement between the observers were evaluated using intraclass correlation (ICC) and graphically by Bland-Altman plots. Results: The study population (n = 122) included 68 (55.7%) female and 54 (44.3%) male subjects. The overall median age was 69.5 years (range 39-95 years). There was perfect agreement between the two observers when defining rectal tumor above or below the takeoff landmark. The reliability of measuring the distance from the anal verge to the sigmoid takeoff was 0.712. Conclusion: Overall, the study found a moderate reliability in assessing the location of the sigmoid takeoff, with a low difference in the distance measuring, as well as a good consensus concerning the determination of tumors in relation to the sigmoid takeoff. Routine implementation of this information within the report seems reasonable.

9.
Curr Oncol ; 29(2): 837-847, 2022 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-35200570

RESUMO

In general, magnetic resonance (MR) diffusion-weighted imaging (DWI) has shown potential in clinical settings. In testicles parenchyma, the DW imaging helps differentiate and characterize benign from malignant lesions. Placement and size of the region of interest (ROI) may affect the ADC value. Therefore, the aim of this study was to investigate the intra- and interobserver variability in testicular tumors when measuring ADC using various types of regions of interest (ROI). Two observers performed the ADC measurements in testicular lesions based on three ROI methods: (1) whole volume, (2) round, and (3) small sample groups. Intra- and interobserver variability was analyzed for all ROI methods using intraclass correlation coefficients (ICC) and bland-altman plots. The two observers performed the measurements twice, three months apart. A total of 26 malignant testicle tumors were included. Interobserver agreement was excellent in tumor length (ICC = 0.98) and tumor width (ICC = 0.98). In addition, intraobserver agreement was excellent in tumor length (ICC = 0.98) and tumor width (ICC = 0.99). The whole volume interobserver agreement in the first reading was excellent (ICC = 0.93). Round ADC had an excellent (ICC = 0.93) and fair (ICC = 0.58) interobserver agreement, in the first and second reading, respectively. Interobserver agreement in ADC small ROIs was good (ICC = 0.87), and good (ICC = 0.78), in the first and second reading, respectively. Intraobserver agreement varied from fair, good to excellent agreement. The ROI method showed varying inter- and intraobserver agreement in ADC measurement. Using multiple small ROI conceded the highest interobserver variability, and, thus, the whole volume or round seem to be the preferable methods.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias Testiculares , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Neoplasias Testiculares/diagnóstico por imagem
10.
Curr Oncol ; 29(2): 1069-1079, 2022 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-35200590

RESUMO

(1) Background: Computer tomography (CT) scanning is currently the standard method for staging of colon cancer; however, the CT based preoperative local staging is far from optimal. The purpose of this study was to investigate the sensitivity and specificity of magnetic resonance imaging (MRI) compared to CT in the T- and N-staging of colon cancer. (2) Methods: Patients underwent a standard contrast-enhanced CT examination. For the abdominal MRI scan, a 3 Tesla unit was used, including diffusion weighted imaging (DWI). Experienced radiologists reported the CT and MRI scans blinded to each other and the endpoint of the pathological report. (3) Results: From 2018 to 2021, 134 patients received CT and MRI scans. CT identified 118 of the 134 tumors, whereas MRI identified all tumors. For discriminating between stage T3ab and T3cd, the sensitivity of CT was 51.1% and of MRI 80.0% (p = 0.02). CT and MRI showed a sensitivity of 21.4% and 46.4% in detecting pT4 tumors and a specificity of 79.0% and 85.0%, respectively. (4) Conclusion: Compared to CT, the sensitivity of MRI was statistically significantly higher in staging advanced T3cd and T4 tumors. MRI has the potential to be used in the treatment planning of colon cancer.


Assuntos
Neoplasias do Colo , Imageamento por Ressonância Magnética , Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/patologia , Computadores , Humanos , Imageamento por Ressonância Magnética/métodos , Estadiamento de Neoplasias , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
11.
Cancers (Basel) ; 13(20)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34680269

RESUMO

Colorectal cancer is the second most common cancer in Europe, and accurate lymph node staging in rectal cancer patients is essential for the selection of their treatment. MRI lymph node staging is complex, and few studies have been published regarding its reproducibility. This study assesses the inter- and intraobserver variability in lymph node size, apparent diffusion coefficient (ADC) measurements, and morphological characterization among inexperienced and experienced radiologists. Four radiologists with different levels of experience in MRI rectal cancer staging analyzed 36 MRI scans of 36 patients with rectal adenocarcinoma. Inter- and intraobserver variation was calculated using interclass correlation coefficients and Cohens-kappa statistics, respectively. Inter- and intraobserver agreement for the length and width measurements was good to excellent, and for that of ADC it was fair to good. Interobserver agreement for the assessment of irregular border was moderate, heterogeneous signal was fair, round shape was fair to moderate, and extramesorectal lymph node location was moderate to almost perfect. Intraobserver agreement for the assessment of irregular border was fair to substantial, heterogeneous signal was fair to moderate, round shape was fair to moderate, and extramesorectal lymph node location was substantial to almost perfect. Our data indicate that subjective variables such as morphological characteristics are less reproducible than numerical variables, regardless of the level of experience of the observers.

12.
Cancers (Basel) ; 13(16)2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34439313

RESUMO

BACKGROUND: Rectal cancer is a common malignancy. Since the introduction of bowel-screening programs, the number of patients with advanced adenomas and early rectal cancer has increased. Despite improved diagnostics, the discrimination between rectal adenomas and early rectal cancer (i.e., pT1-T2) remains challenging. The purpose of this systematic review was to evaluate the diagnostic performance of endorectal ultrasound (ERUS) elastography in discriminating rectal adenomas from cancer. METHOD: Using PRISMA guidelines, a systematic search was performed on PubMed, Embase, and MEDLINE databases. Studies evaluating the primary staging of rectal adenomas and cancer using ERUS elastography were included. RESULTS: Six studies were identified; three evaluated the discrimination between adenomas and cancer; two evaluated adenomas and early rectal cancer (i.e., pT1-T2); one evaluated performance on different T categories. All studies reported increased diagnostic accuracy of ERUS elastography compared to ERUS. Sensitivity, specificity and accuracy ranged 0.93-1.00, 0.83-1.00 and 0.91-1.00, respectively, when discriminating adenomas from cancer. In the differentiation between adenomas and early rectal cancer, the sensitivity, specificity and accuracy were 0.82-1.00, 0.86-1.00 and 0.84-1.00, respectively. CONCLUSION: Elastography increases the accuracy of ERUS and may provide valuable information on malignant transformation of rectal lesions.

13.
Insights Imaging ; 12(1): 46, 2021 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-33846876

RESUMO

OBJECTIVE: To investigate the anogenital distance in patients with and without testicular microlithiasis (TML). METHODS: A total of 101 patients underwent a conventional standard clinical B-mode scrotal ultrasonography and scrotal MRI. The patients were divided into two groups: patients with TML and non-TML. The latter served as control group. The anogenital distance was measured by a straight line from center of the anus to the posterior base of scrotum using MRI. RESULTS: In the TML group, mean AGD was 5.4 (± 1.07) cm (range 29-79 mm), and in non-TML 5.9 (± 1.03) cm (range 35-85 mm) (p = 0.04). CONCLUSION: MRI is a useful tool to measure the AGD. It is easy to perform without any discomfort to patients. We found AGD to be lower in patients with TML.

14.
Dan Med J ; 68(11)2021 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-34983731

RESUMO

INTRODUCTION Use of an urgent fast-track pathway comprising contrast-enhanced computed tomography (CECT) is a recognised method for diagnostic evaluation of patients with non-specific symptoms. This study focused on a subgroup of patients with non-specific symptoms who are diagnosed outside of fast-track pathways. To investigate the cancer prevalence in patients with non-specific symptoms outside of fast-track pathways undergoing a thoracoabdominal CECT. METHODSThis was a retrospective observational study including patients referred for a thoracoabdominal CECT. Patients with non-specified symptoms were included. All pathology reports were reviewed to confirm histopathological findings. Data were collected during a one-year period from the Department of Radiology, Vejle Hospital. RESULTS A total of 238 patients were included; 125 (52.5%) women and 113 (47.5%) men. The median age was 69 years (range: 29-99 years). Fifty (21%) patients (25 men and 25 women) were diagnosed with malignant conditions by computed tomography (CT), all of which were confirmed by biopsy (median age = 68 years, range: 43-87 years). An additional ten patients had CT findings consistent with malignancies that were not confirmed by biopsy (median age = 86 years, range: 58-93 years). CONCLUSION We found a 21% prevalence of cancer. FUNDING none. TRIAL REGISTRATION not relevant.


Assuntos
Meios de Contraste , Neoplasias , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Encaminhamento e Consulta , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
16.
Radiol Case Rep ; 14(11): 1364-1367, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31516654

RESUMO

Colorectal cancer is one of the most common cancers in the developed countries, and colon cancer is well documented. However, it is very rare for a primary colon cancer to exist in a scrotal hernia, and even rarer for the scrotal hernia to perforate. Here, we describe an unusual case where a 75-year-old patient with a colon tumor that perforated in a scrotal hernia. The teaching point is to highlight the computed tomography scan imaging characteristics of this rare finding in patients with both abdominal and scrotal pain.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...