Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Heart Rhythm ; 20(2): 233-240, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-37283031

RESUMO

BACKGROUND: Elevated resting heart rate is a risk factor for cardiovascular events. OBJECTIVE: The purpose of this study was to investigate the clinical significance of nocturnal heart rate (nHR) and 24-hour mean heart rate (24h-HR) obtained by continuous remote monitoring (RM) of implantable devices. METHODS: We analyzed daily-sampled trends of nHR, 24h-HR, and physical activity in patients on ß-blocker therapy for chronic heart failure and with implantable cardioverter-defibrillators or cardiac resynchronization therapy defibrillators (CRT-Ds). Patients were grouped by average nHR and 24h-HR quartile during follow-up to estimate the respective incidence of nonarrhythmic death and device-treated ventricular tachycardia/fibrillation (VT/VF). RESULTS: The study cohort included 1330 patients (median age 69 years [interquartile range 61-77 years]; 41% [n = 550] with CRT-D; median follow-up 25 months [interquartile range 13-42 months]). Compared with patients in the lowest nHR quartile (≤57 beats/min) group, patients in the highest quartile group (>65 beats/min) had an increased risk of nonarrhythmic death (adjusted hazard ratio [AHR] 2.25; 95% confidence interval [CI] 1.13-4.50; P = .021) and VT/VF (AHR 1.98; 95% CI 1.40-2.79; P < .001) and were characterized by the lowest level of physical activity (P ≤ .0004 vs every other nHR quartiles). The highest 24h-HR quartile group (>75 beats/min) showed an increased risk of VT/VF (AHR 2.13; 95% CI 1.52-2.99; P < .001) and a weaker though significant association with nonarrhythmic mortality (AHR 1.80; 95% CI 1.00-3.22; P = .05) as compared with the lowest 24h-HR quartile group (≤65 beats/min). CONCLUSION: In remotely monitored patients with implantable cardioverter-defibrillator/CRT-D on ß-blocker therapy for heart failure, elevated heart rates (nHR >65 beats/min and 24h-HR >75 beats/min) were associated with increased mortality and VT/VF risk. nHR showed a stronger association than 24h-HR with worst prognosis and lowest physical activity.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Disfunção Ventricular Esquerda , Humanos , Pessoa de Meia-Idade , Idoso , Frequência Cardíaca , Prognóstico , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Arritmias Cardíacas/terapia , Fatores de Risco , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Disfunção Ventricular Esquerda/complicações
2.
JACC Clin Electrophysiol ; 8(12): 1553-1562, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36543505

RESUMO

BACKGROUND: Causes of sex differences in incidence of sustained ventricular arrhythmias (SVAs) are poorly understood. OBJECTIVES: This study aims to investigate sex-specific risk of SVAs and device therapies by balancing sex groups in relation to several baseline characteristics with the propensity score (PS). METHODS: We used a large remote monitoring dataset from implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds). Study endpoints were time to the first appropriate SVA, time to the first device therapy for SVA, and time to the first ICD shock. Results were compared between females and a PS-matched male subgroup. RESULTS: In a cohort of 2,532 patients with an ICD or CRT-D (median age, 70 years), 488 patients (19.3%) were women. After selecting 488 men PS-matched for 19 variables relative to baseline demographics, implant indications, principal comorbidities, and concomitant therapy, yet the SVA rate at the 2.1-year median follow-up was significantly lower in women than in man (adjusted HR: 0.65; 95% CI: 0.51-0.81; P < 0.001). Women also showed a reduced risk of any device therapy (HR: 0.59; 95% CI: 0.45-0.76; P < 0.001) and shocks (HR: 0.66; 95% CI: 0.47-0.94; P = 0.021). Differences in sex-specific SVA risk profile were not confirmed in CRT-D patients (HR: 0.78; 95% CI: 0.55-1.09; P = 0.14) nor in those with an ejection fraction <30% (HR: 0.80; 95% CI: 0.52-1.23; P = 0.31). CONCLUSIONS: After matching demographics, indications, principal comorbidities, and concomitant therapy, women still exhibited a lower SVA risk profile than men, except in the subgroups of CRT-D or/and ejection fraction <30%.


Assuntos
Desfibriladores Implantáveis , Humanos , Masculino , Feminino , Idoso , Desfibriladores Implantáveis/efeitos adversos , Pontuação de Propensão , Resultado do Tratamento , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Cardioversão Elétrica
3.
J Interv Card Electrophysiol ; 64(3): 607-619, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34709504

RESUMO

PURPOSE: The purpose of this study was to assess the available mortality risk stratification models for implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) patients. METHODS: We conducted a review of mortality risk stratification models and tested their ability to improve prediction of 1-year survival after implant in a database of patients who received a remotely controlled ICD/CRT-D device during routine care and included in the independent Home Monitoring Expert Alliance registry. RESULTS: We identified ten predicting models published in peer-reviewed journals between 2000 and 2021 (Parkash, PACE, MADIT, aCCI, CHA2DS2-VASc quartiles, CIDS, FADES, Sjoblom, AAACC, and MADIT-ICD non-arrhythmic mortality score) that could be tested in our database as based on common demographic, clinical, echocardiographic, electrocardiographic, and laboratory variables. Our cohort included 1,911 patients with left ventricular dysfunction (median age 71, 18.3% female) from sites not using any risk stratification score for systematic patient screening. Patients received an ICD (53.8%) or CRT-D (46.2%) between 2011 and 2017, after standard physician evaluation. There were 56 deaths within 1-year post-implant, with an all-cause mortality rate of 2.9% (95% confidence interval [CI], 2.3-3.8%). Four predicting models (Parkash, MADIT, AAACC, and MADIT-ICD non-arrhythmic mortality score) were significantly associated with increased risk of 1-year mortality with hazard ratios ranging from 3.75 (CI, 1.31-10.7) to 6.53 (CI 1.52-28.0, p ≤ 0.014 for all four). Positive predictive values of 1-year mortality were below 25% for all models. CONCLUSION: In our analysis, the models we tested conferred modest incremental predicting power to ordinary screening methods.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Medição de Risco , Fatores de Risco , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34252991

RESUMO

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 32(5): 1296-1304, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33783875

RESUMO

BACKGROUND: No data exist on the ability of the novel Rhythmia 3-D mapping system to minimize fluoroscopy exposure during transcatheter ablation of arrhythmias. We report data on the feasibility and safety of a minimal fluoroscopic approach using this system in supraventricular tachycardia (SVT) procedures. METHODS: Consecutive patients were enrolled in the CHARISMA registry at 12 centers. All right-sided procedures performed with the Rhythmia mapping system were analyzed. The acquired electroanatomic information was used to reconstruct 3-D cardiac geometry; fluoroscopic confirmation was used whenever deemed necessary. RESULTS: Three hundred twenty-five patients (mean age = 56 ± 17 years, 57% male) were included: 152 atrioventricular nodal reentrant tachycardia, 116 atrial flutter, 41 and 16 right-sided accessory pathway and atrial tachycardia, respectively. Overall, 27 481 s of fluoroscopy were used (84.6 ± 224 s per procedure, equivalent effective dose = 1.1 ± 3.7 mSv per patient). One hundred ninety-two procedures (59.1%) were completed without the use of fluoroscopy (zero fluoroscopy, ZF). In multivariate analysis, the presence of a fellow in training (OR = 0.15, 95% CI: 0.05-0.46; p = .0008), radiofrequency application (0.99, 0.99-1.00; p = .0002), and mapping times (0.99, 0.99-1.00; p = .042) were all inversely associated with ZF approach. Acute procedural success was achieved in 97.8% of the cases (98.4 vs. 97% in the ZF vs. non-ZF group; p = .4503). During a mean of 290.7 ± 169.6 days follow-up, no major adverse events were reported, and recurrence of the primary arrhythmia was 2.5% (2.1 vs. 3% in the ZF vs. non-ZF group; p = .7206). CONCLUSIONS: The Rhythmia mapping system permits transcatheter ablation of right-sided SVT with minimal fluoroscopy exposure. Even more, in most cases, the system enables a ZF approach, without affecting safety and efficacy.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
6.
G Ital Cardiol (Rome) ; 20(1): 8-19, 2019 Jan.
Artigo em Italiano | MEDLINE | ID: mdl-30638211

RESUMO

Cardiac magnetic resonance is an accurate and versatile tool for multiparametric morphologic and functional evaluation of the heart and great vessels, with a wide range of clinical applications: from acute and chronic ischemic heart disease to the assessment of the substrate of complex ventricular arrhythmias and the follow-up of patients with valvular and congenital heart disease. The accuracy in cardiac volume and ejection fraction quantification, tissue characterization, valvular regurgitant fraction and cardiac shunt assessment, pharmachologic stress myocardial perfusion and three-dimensional reconstruction of great vessels are the points of strength that have made Cardiac magnetic resonance an invaluable tool for diagnostic, classification and follow-up of patients with various cardiac diseases.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Volume Cardíaco/fisiologia , Doenças Cardiovasculares/fisiopatologia , Humanos , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Volume Sistólico/fisiologia
7.
G Ital Cardiol (Rome) ; 19(12): 679-691, 2018 Dec.
Artigo em Italiano | MEDLINE | ID: mdl-30520882

RESUMO

Cardiac magnetic resonance (CMR) has proved to be a powerful tool in the assessment of several cardiac diseases, thanks to its capability to offer multiparametric morphologic and functional evaluation of the heart and great vessels, using neither ionizing radiations nor nephrotoxic contrast medium. The accuracy in quantification of cardiac volumes and ejection fraction (gold standard) together with native and post-contrast myocardial tissue characterization have made CMR an invaluable tool for the diagnosis, prognosis and therapeutic planning in patients with heart failure and cardiomyopathy.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Humanos , Prognóstico , Reprodutibilidade dos Testes
8.
Circ Arrhythm Electrophysiol ; 11(3): e005592, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29874166

RESUMO

BACKGROUND: This multicenter, prospective study evaluated the determinants of zero-fluoroscopy (ZFL) ablation of supraventricular tachycardias. METHODS AND RESULTS: Four hundred thirty patients (215 male, 55.4±22.1 years) with indication to electrophysiological study or ablation of supraventricular tachycardias were enrolled. All participating physicians agreed to follow the as low as reasonably achievable policy. A procedure was defined as ZFL when no fluoroscopy was used. The total fluoroscopy time inversely correlated to the number of procedures previously performed by each operator since study start (r=-0.112; P=0.02). Two hundred eighty-nine procedures (67.2%) were ZFL; multivariable analysis identified as predictors of ZFL: procedure after the 30th for each operator, compared with procedures up to the ninth (P=0.011; hazard ratio, 3.49; 95% confidence interval [CI], 1.79-6.80); the type of arrhythmia (P=0.031; electrophysiological study and atrioventricular nodal reentry tachycardia ablation having the highest probability of ZFL; hazard ratio, 6.87; 95% CI, 2.08-22.7 and hazard ratio, 2.02; 95% CI, 1.04-3.91, respectively); the operator's (P=0.002) and patient's age (P=0.009). Among operators, achievement of ZFL varied from 0% to 100%; 8 (22.8%) operators achieved ZFL in <25% of their procedures; 17 (48.6%) operators achieved ZFL in >75% of their procedures. The probability of ZFL increased by 2.8% (hazard ratio, 0.98; 95% CI, 0.97-0.99) as patient's age decreased by 1 year. Acute procedural success was obtained in all cases. CONCLUSIONS: The use of 3-dimensional mapping system completely avoided the use of fluoroscopy in most cases, with very low fluoroscopy time in the remaining and high safety and effectiveness profiles. Achievement of ZFL was predicted by the type of arrhythmia, operator's experience, and patient's age.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Fluoroscopia/métodos , Cirurgia Assistida por Computador/métodos , Taquicardia Supraventricular/cirurgia , Feminino , Seguimentos , Humanos , Imageamento Tridimensional , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
9.
Clin Cardiol ; 41(4): 494-501, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29663442

RESUMO

BACKGROUND: Late gadolinium enhancement (LGE) assessed with cardiovascular magnetic resonance (CMR) correlates with ventricular arrhythmias and survival in patients with structural heart disease. Whether some LGE characteristics may specifically improve prediction of arrhythmic outcomes is unknown. HYPOTHESIS: We sought to evaluate scar characteristics assessed with CMR to predict implantable cardioverter-defibrillator (ICD) interventions in dilated cardiomyopathy of different etiology. METHODS: 96 consecutive patients evaluated with CMR received an ICD. Biventricular volumes, ejection fraction, and myocardial LGE were evaluated. LGE was defined as "complex" (Cx-LGE) in presence of ≥1 of the following: ischemic pattern, involving ≥2 different coronary territories; epicardial pattern; global endocardial pattern; and presence of ≥2 different patterns. The primary endpoint was occurrence of any appropriate ICD intervention. A composite secondary endpoint of cardiovascular death, cardiac transplantation, or ventricular assist device implantation was also considered. RESULTS: During a median follow-up of 75 months, 30 and 25 patients reached the primary and secondary endpoints, respectively. Cx-LGE was correlated with a worse primary endpoint survival (log-rank P < 0.001). Cx-LGE and right ventricular end-diastolic volume were independently associated with the primary endpoint (HR: 3.22, 95% CI: 1.56-6.65, P = 0.002; and HR: 1.06, 95% CI: 1.00-1.12, P = 0.045, respectively), but not with the secondary endpoint. CONCLUSIONS: Cx-LGE identified at CMR imaging seems promising as an independent and specific prognostic factor of ventricular arrhythmias requiring ICD therapy in dilated cardiomyopathy of different etiologies.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Cardiomiopatia Dilatada/diagnóstico por imagem , Cicatriz/diagnóstico por imagem , Tomada de Decisão Clínica , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Imagem Cinética por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Cardiomiopatia Dilatada/etiologia , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatia Dilatada/terapia , Cicatriz/etiologia , Cicatriz/fisiopatologia , Cicatriz/terapia , Meios de Contraste/administração & dosagem , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Progressão da Doença , Intervalo Livre de Doença , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
J Arrhythm ; 33(5): 494-496, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29021856

RESUMO

In patients with left ventricular assist device (LVAD), a minority of post-operative ventricular tachycardias (VTs) is caused by contact between the inflow cannula and the endocardium. Currently, electrophysiologic characteristics and pathologic features of this condition are lacking. We report on a case of a successfully ablated mechanical VT. After VT recurrence, heart transplantation took place. Pathologic observations were consistent with direct tissue injury and inflammation, eventually contributing to persisting arrhythmias. Radiofrequency catheter ablation can be a safe and effective option to treat arrhythmias caused by inflow cannula interference in the short term, although a high recurrence rate is expected.

11.
Eur Heart J Cardiovasc Imaging ; 18(2): 130-137, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27625368

RESUMO

AIMS: The aim of the present study was to assess the association of the presence and amount of late gadolinium enhancement (LGE) at cardiac magnetic resonance (CMR) with cardiovascular adverse events in patients with orthotopic heart transplantation (HTx). METHODS AND RESULTS: We enrolled 48 patients (mean age, 54.7 ± 14.6 years; 37 men) at various stages after HTx. All patients underwent standard CMR at 1.5 T, to characterize both cardiac anatomy and LGE. Late gadolinium enhancement was detected in 26 patients (54%). All-cause and cardiovascular mortalities, and a composite of major adverse cardiovascular events (MACE) recurrence were evaluated during the follow-up period for a median of 5.16 years. Ten patients (21%) died and 26 (54%) were readmitted because of MACE. Multivariate Cox analysis identified as independent predictors of MACE a diagnosis of cardiac allograft vasculopathy (CAV) (HR 3.63; 1.5-8.7 95% CI; P = 0.0039), left ventricular end systolic volume index (HR 1.04; 95% CI 1.01-1.079; P = 0.008), LGE mass (HR 1.04; 1.01-1.06 95% CI; P = 0.0007), LGE % of left ventricular mass (HR 1.083; 1.03-1.13 95% CI; P = 0.0002). Independent predictors of all-cause death were CAV (HR 6.33; 95% CI 1.33-30.03; P = 0.0201), LGE mass (HR 1.04; 1.01-1.07 95% CI; P = 0.005), LGE % of left ventricular mass (HR 1.075; 1.02-1.13 95% CI; P = 0.007). Patients with CAV had a risk of MACE by 5 years of 67% (95% CI 0.309-0.851%); the addition of 7.9 LGE % to the risk model increased the predicted risk to 88% (95% CI 0.572-0.967%). CONCLUSIONS: The current study demonstrated that the presence of CAV and the total amount of LGE have a significant independent association with MACE and mortality in HTx patients.


Assuntos
Gadolínio DTPA , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Transplante de Coração/métodos , Imagem Cinética por Ressonância Magnética/métodos , Intensificação de Imagem Radiográfica/métodos , Adulto , Análise de Variância , Causas de Morte , Estudos de Coortes , Feminino , Rejeição de Enxerto , Sobrevivência de Enxerto , Insuficiência Cardíaca/diagnóstico por imagem , Transplante de Coração/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Risco Ajustado , Estatísticas não Paramétricas , Análise de Sobrevida , Fatores de Tempo
12.
J Arrhythm ; 31(6): 401-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26702324

RESUMO

A 77-year-old man with ischemic cardiomyopathy and a cardiac resynchronization therapy-defibrillator (CRT-D) device came to our attention due to incessant ventricular tachycardia and multiple implantable cardioverter defibrillator (ICD) shocks. An electrocardiogram showed non-sustained monomorphic ventricular tachycardias (NSVTs) constantly occurring after each biventricular stimulation. During an electrophysiological study, NSVTs reproducibly recurred only after right ventricular (RV) pacing; LV pacing did not induce any NSVTs. The activation map was consistent with a localized reentry at the interventricular septum, and a double exit; at the LV exit site, a single radiofrequency energy application immediately interrupted the occurrence of the NSVTs. Current evidence supports LV pacing to be pro-arrhythmogenic in few CRT patients. This unusual case shows that RV pacing during CRT could produce frequent ventricular arrhythmias and arrhythmic storm. Catheter ablation can be considered an effective therapeutic option, especially when CRT maintenance is highly advisable.

13.
Int J Cardiol ; 172(1): 64-71, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24456869

RESUMO

BACKGROUND: Reverse remodeling and increased LVEF after CRT correlate with survival and heart failure hospitalizations, but their relationship with the risk of SCD is unclear. We aimed to evaluate whether exceeding a threshold value of 35% for left ventricular ejection fraction (LVEF) 1 year after cardiac resynchronization therapy (CRT) predicts survival and freedom from sudden cardiac death (SCD). METHODS: 330 patients who survived ≥ 6 months after CRT (males 80%, age 62 ± 11 years) were grouped according to 1-year LVEF ≤ 35% (Group 1, n=187, 57%) or >35% (Group 2, n=143, 43%). According to changes vs. baseline (reduction of left end-systolic volume [LVESV] ≥ 10% or increase of LVEF% > 10 units), patients were also classified as echocardiographic (Echo) non-responders (Group A, n=152, 46%) or responders (Group B, n=178, 54%). RESULTS: At baseline, LVESV volume was larger and LVEF was lower in Group 1 vs. Group 2 (p<0.001). After 1 year, echocardiographic improvement was greater in Group 2 vs. Group 1 (p<0.001 for changes in both LVESV and LVEF). Over a median follow-up of 49 months, 47 patients (14%) died, 36 in Group 1 vs. 11 in Group 2 (19% vs. 8%, p=0.004). A significantly higher rate of freedom from all-cause mortality (p=0.002), cardiovascular mortality (p<0.001) and SCD (p<0.001) was observed in Group 2. Multivariate analysis demonstrated that only 1-year LVEF >35% was associated with freedom from SCD/VF. CONCLUSIONS: LVEF >35% after 1 year of CRT characterizes a favorable long-term outcome, with a very low risk for SCD.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/mortalidade , Volume Sistólico , Função Ventricular Esquerda , Idoso , Morte Súbita Cardíaca/epidemiologia , Intervalo Livre de Doença , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Prognóstico , Fatores de Risco
14.
G Ital Cardiol (Rome) ; 13(10 Suppl 2): 36S-40S, 2012 Oct.
Artigo em Italiano | MEDLINE | ID: mdl-23096373

RESUMO

A large number of studies have demonstrated that remote control of implantable devices (home monitoring, HM) is beneficial for patients, as it allows strict and tailored controls with earlier identification of potential problems, by avoiding unnecessary visits. HM is also beneficial for hospitals, as it progressively reduces the resources necessary for routine controls and contributes to a better management of critical patients. According to current European and Italian guidelines, HM can replace standard ambulatory monitoring, thereby decreasing the number of outpatient visits for each individual patient (it is possible to schedule a comprehensive clinical evaluation at 1 year rather than every 6-8 months, while performing controls at 1 and 3 months by remote transmission). At present, however, reimbursement of HM services is not covered by the National Health System and, as a consequence, cannot be performed as an institutional activity within the hospital. In addition, many critical issues remain to be resolved before the HM system can be fully implemented into daily clinical management, particularly in patients with heart failure at higher risk for sudden cardiac death.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca/terapia , Monitorização Ambulatorial , Telemedicina , Humanos
15.
Ann Thorac Surg ; 94(2): 649-51, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22818314

RESUMO

Several patterns of anomalous pulmonary venous drainage have been described in the literature, and bilateral partial pulmonary anomalous vein connection (PAPVC) has been described as a rare congenital cardiac anomaly. We report an unusual type of bilateral PAPVC, involving both the superior right and left pulmonary veins draining into the left brachiocephalic vein in a young adult who was symptomatic with dyspnea and a dry cough.


Assuntos
Anormalidades Múltiplas/diagnóstico , Veias Braquiocefálicas/anormalidades , Veias Pulmonares/anormalidades , Adulto , Feminino , Humanos
16.
Int J Cardiol ; 158(3): 394-9, 2012 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-21345500

RESUMO

BACKGROUND: Isolated ventricular non-compaction (IVNC) is frequently, but not invariably, associated with left ventricular (LV) systolic dysfunction. Factors impacting on regional and global LV function are unknown. The aim of the study was to apply magnetic resonance imaging (MRI) to evaluate the impact of extent and severity of ventricular non-compaction on LV systolic function in patients with IVNC. METHODS: Sixteen adult patients with IVNC as defined by previously validated MRI criteria [ratio between end-diastolic thickness of non-compacted and compacted myocardium (NC/C ratio)> 2.3 in ≥ 1 LV segment] were enrolled. Short-axis cine images were employed for analysis. Applying a 16-segment LV model, regional systolic performance was assessed qualitatively (wall motion score, WMS; 1 = normal, 2 = mild hypokinesia, 3 = moderate-to-severe hypokinesia, and 4 = a/dyskinesia) as well as quantitatively [fractional wall thickening, FWT (%)=100 × (end-diastolic wall thickness-end-systolic wall thickness)/end-diastolic wall thickness)]. RESULTS: Mean LV ejection fraction was 43.8 ± 15.4% (range, 17-68%). Regional disease severity, as expressed by the NC/C ratio, revealed a significant correlation with WMS (r=0.26; p=0.018) and FWT (r=-0.30; p=0.006). The total number of non-compacted segments/patient (NoNC) as an index of disease extent was a significant independent correlate of LV ejection fraction by multivariate regression analysis (ß=-5.24; p=0.038) and an excellent predictor of global LV dysfunction (ROC analysis, AUC=0.98; p<0.0001). CONCLUSIONS: In patients with IVNC, disease severity correlates with the degree of LV dysfunction at a regional level. The extent of myocardial non-compaction is an independent predictor of global LV dysfunction.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Miocárdio Ventricular não Compactado Isolado/patologia , Miocárdio Ventricular não Compactado Isolado/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Sístole/fisiologia , Adulto , Idoso , Técnicas de Imagem Cardíaca/normas , Técnicas de Imagem Cardíaca/estatística & dados numéricos , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética/normas , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Adulto Jovem
17.
G Ital Cardiol (Rome) ; 11(10 Suppl 1): 12S-16S, 2010 Oct.
Artigo em Italiano | MEDLINE | ID: mdl-21416820

RESUMO

Treatment of atrial fibrillation is still an ongoing issue, due to the continuous development of new therapeutic options. As regards pharmacological prophylaxis, dronedarone, a non-iodinated derivative of amiodarone, has recently been evaluated in patients affected by atrial fibrillation and demonstrated a good safety and efficacy profile; it could be particularly beneficial in patients with advanced age, hypertension, diabetes, previous stroke, or left atrial enlargement, due to its association with lower mortality and hospital admissions, while it is not indicated in patients with advanced heart failure. Much more has been developed in the field of ablation, leading to a huge variability in technical approach and patient characteristics. In general, ablation can be considered an effective procedure for appropriately selected patients and shows an acceptable safety profile when performed by trained operators. On the basis of the available evidence, ablation should be the first choice in young patients with lone atrial fibrillation, and a second choice (after failed pharmacological prevention) in older patients or when a mild structural heart disease coexists, particularly when the arrhythmic burden is high and the patient is symptomatic; in patients with a major heart disease, ablation can be considered on a case by case basis.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Amiodarona/administração & dosagem , Amiodarona/análogos & derivados , Amiodarona/uso terapêutico , Antiarrítmicos/administração & dosagem , Ensaios Clínicos como Assunto , Dronedarona , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Recidiva , Fatores de Tempo , Resultado do Tratamento
18.
G Ital Cardiol (Rome) ; 10(2): 101-7, 2009 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-19348147

RESUMO

BACKGROUND: Protocols of cardiac magnetic resonance imaging (CMR) during pharmacological stress with adenosine may include scanning sequences for the evaluation of both myocardial perfusion and contractility. The aim of this study was to define the feasibility and diagnostic accuracy of a stress CMR protocol including the combined evaluation of regional myocardial perfusion and contractility in the identification of patients with significant coronary artery disease. METHODS: A total of 184 consecutive patients with known or suspected coronary artery disease underwent stress CMR (adenosine, 140 microg/kg/min). The employed protocol included the application of the following sequences for image acquisition: 1) cine imaging at rest; 2) perfusion imaging (Gd-DTPA, 0.05 mmol/kg) during pharmacological stress; 3) cine imaging during pharmacological stress; 4) perfusion imaging (Gd-DTPA, 0.05 mmol/kg) at rest. RESULTS: Stress CMR was completed in 182 patients (99%). Minor complications were observed in 12 patients (7%) during adenosine infusion, while one patient developed severe bronchospasm and another patient experienced persistent myocardial ischemia. Good/excellent-quality images were obtained in 91% of stress CMR exams. In a subgroup of 37 patients, when compared with the use of perfusion images alone, combination of perfusion and contractility data provided higher levels of sensitivity (74 vs 89%, p < 0.05) and of negative predictive value (71 vs 85%, p < 0.05) in identifying patients with significant coronary artery disease by invasive angiography. CONCLUSIONS: Adenosine stress CMR including the evaluation of both myocardial perfusion and contractility is feasible and improves diagnostic performance in the recognition of patients with significant coronary artery disease.


Assuntos
Adenosina , Doença da Artéria Coronariana/diagnóstico , Teste de Esforço/métodos , Imageamento por Ressonância Magnética , Contração Miocárdica , Imagem de Perfusão do Miocárdio , Vasodilatadores , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade
20.
Ann Thorac Surg ; 86(5): 1466-71; discussion 1472, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19049732

RESUMO

BACKGROUND: Pulmonary regurgitation (PR) occurs frequently after tetralogy of Fallot (TOF) repair, impairing long-term prognosis and necessitating reinterventions. Myocardial damage, invasiveness, and the risks of pulmonary valve replacement (PVR) therefore need to be minimized. The new Shelhigh Injectable Stented Pulmonic Valve (Shelhigh Inc, Union, NJ) allows implantation without cardiopulmonary bypass (CPB) under direct control. METHODS: Twelve symptomatic patients (age, 21.3 +/- 12.5; range, 5.8 to 53.5 years) with severe PR and progressive right ventricular (RV) dilatation with dysfunction received the Shelhigh valve in sizes 21 (n = 1), 25 (n = 4), 27 (n = 3), 29 (n = 2), and 31 mm (n = 2). RESULTS: Valve insertion was successful and hemodynamic performance excellent in all: peak systolic gradient, 14.5 +/- 4.6 (range, 10 to 20) mm Hg; mean gradient, 6.3 +/- 1.6 (range, 4 to 8) mm Hg. Four patients underwent concomitant procedures on CPB: one reduction plasty of a dilated main pulmonary artery, two tricuspid valve repairs, and one VSD closure. Early recovery was uneventful. There were no reoperations. During a mean follow-up of 5.4 +/- 4.3 months (range, 0.3 to 10.6 months) echocardiography showed good results, with low gradients and recovered RV function in all. All presented in New York Heart Association functional class 1 at the latest follow-up. CONCLUSIONS: The Shelhigh valve allows easy PVR without CPB up to large valve sizes, with less invasiveness compared with a conventional approach. Further follow-up is needed to assess its durability and long-term performance.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Adolescente , Adulto , Criança , Pré-Escolar , Ecocardiografia , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/cirurgia , Próteses Valvulares Cardíacas , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Stents , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...