Arq Bras Cardiol ; 120(7): e20220564, 2023 07.
Artigo em Inglês, Português | MEDLINE | ID: mdl-37585896

RESUMO

BACKGROUND: For practical and protective ventilation during cardiopulmonary resuscitation (CPR), a 150-grams mechanical ventilator (VLP2000E) that limits peak inspiratory pressure (PIP) during simultaneous ventilation with chest compressions was developed. OBJECTIVES: To evaluate the feasibility of VLP2000E ventilation during CPR and to compare monitored parameters versus bag-valve ventilation. METHODS: A randomized experimental study with 10 intubated pigs per group. After seven minutes of ventricular fibrillation, 2-minute CPR cycles were delivered. All animals were placed on VLP2000E after achieving return of spontaneous circulation (ROSC). RESULTS: Bag-valve and VLP2000E groups had similar ROSC rate (60% vs. 50%, respectively) and arterial oxygen saturation in most CPR cycles, different baseline tidal volume [0.764 (0.068) vs. 0.591 (0.123) L, p = 0.0309, respectively] and, in 14 cycles, different PIP [52 (9) vs. 39 (5) cm H2O, respectively], tidal volume [0.635 (0.172) vs. 0.306 (0.129) L], ETCO2[14 (8) vs. 27 (9) mm Hg], and peak inspiratory flow [0.878 (0.234) vs. 0.533 (0.105) L/s], all p < 0.0001. Dynamic lung compliance (≥ 0.025 L/cm H2O) decreased after ROSC in bag-valve group but was maintained in VLP2000E group [0.019 (0.006) vs. 0.024 (0.008) L/cm H2O, p = 0.0003]. CONCLUSIONS: VLP2000E ventilation during CPR is feasible and equivalent to bag-valve ventilation in ROSC rate and arterial oxygen saturation. It produces better respiratory parameters, with lower airway pressure and tidal volume. VLP2000E ventilation also prevents the significant decrease of dynamic lung compliance observed after bag-valve ventilation. Further preclinical studies confirming these findings would be interesting.


FUNDAMENTOS: Para ventilação prática e protetora durante a ressuscitação cardiopulmonar (RCP), desenvolveu-se um ventilador mecânico (VLP2000E) de 150 gramas que limita o pico de pressão inspiratória (PPI) durante ventilação e compressões torácicas simultâneas. OBJETIVOS: Avaliar a viabilidade da ventilação com VLP2000E durante RCP e comparar os parâmetros monitorados versus ventilação com bolsa-válvula. MÉTODOS: Estudo experimental randomizado com 10 porcos intubados por grupo. Após sete minutos de fibrilação ventricular, iniciaram-se ciclos de RCP de 2 minutos. Todos os animais foram ventilados com VLP2000E após o retorno da circulação espontânea (RCE). RESULTADOS: Os grupos bolsa-válvula e VLP2000E apresentaram taxa de RCE (60% vs. 50%, respectivamente) e saturação arterial de oxigênio similares na maioria dos ciclos de RCP, volume corrente basal diferente [0,764 (0,068) vs. 0,591 (0,123) L, p = 0,0309, respectivamente] e, em 14 ciclos, diferentes PPI [52 (9) vs. 39 (5) cm H2O, respectivamente], volume corrente [0,635 (0,172) vs. 0,306 (0,129) L], ETCO2 [14 (8) vs. 27 (9) mm Hg], e pico de fluxo inspiratório [0,878 (0,234) vs. 0,533 (0,105) L/s], todos p < 0,0001. A complacência pulmonar dinâmica (≥ 0,025 L/cm H2O) diminuiu após o RCE no grupo bolsa-válvula, mas se manteve no grupo VLP2000E [ 0,019 (0,006) vs. 0,024 (0,008) L/cm H2O, p = 0,0003]. CONCLUSÕES: Ventilação com VLP2000E durante RCP é viável e equivalente a ventilação com bolsa-válvula quanto à taxa de RCE e saturação arterial de oxigênio. Esse ventilador produz melhores parâmetros respiratórios, com pressão das vias aéreas e volume corrente menores. Ventilação com VLP2000E também previne a redução significante da complacência pulmonar dinâmica observada após ventilação com bolsa-válvula. Seria interessante realizar mais estudos pré-clínicos para confirmar esses resultados.


Assuntos
Reanimação Cardiopulmonar , Animais , Pulmão , Complacência Pulmonar , Respiração Artificial , Suínos , Ventiladores Mecânicos , Fibrilação Ventricular
2.
Arq. bras. cardiol ; 120(7): e20220564, 2023. tab, graf
Artigo em Português | LILACS, CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1447311

RESUMO

Resumo Fundamentos Para ventilação prática e protetora durante a ressuscitação cardiopulmonar (RCP), desenvolveu-se um ventilador mecânico (VLP2000E) de 150 gramas que limita o pico de pressão inspiratória (PPI) durante ventilação e compressões torácicas simultâneas. Objetivos Avaliar a viabilidade da ventilação com VLP2000E durante RCP e comparar os parâmetros monitorados versus ventilação com bolsa-válvula. Métodos Estudo experimental randomizado com 10 porcos intubados por grupo. Após sete minutos de fibrilação ventricular, iniciaram-se ciclos de RCP de 2 minutos. Todos os animais foram ventilados com VLP2000E após o retorno da circulação espontânea (RCE). Resultados Os grupos bolsa-válvula e VLP2000E apresentaram taxa de RCE (60% vs. 50%, respectivamente) e saturação arterial de oxigênio similares na maioria dos ciclos de RCP, volume corrente basal diferente [0,764 (0,068) vs. 0,591 (0,123) L, p = 0,0309, respectivamente] e, em 14 ciclos, diferentes PPI [52 (9) vs. 39 (5) cm H2O, respectivamente], volume corrente [0,635 (0,172) vs. 0,306 (0,129) L], ETCO2 [14 (8) vs. 27 (9) mm Hg], e pico de fluxo inspiratório [0,878 (0,234) vs. 0,533 (0,105) L/s], todos p < 0,0001. A complacência pulmonar dinâmica (≥ 0,025 L/cm H2O) diminuiu após o RCE no grupo bolsa-válvula, mas se manteve no grupo VLP2000E [ 0,019 (0,006) vs. 0,024 (0,008) L/cm H2O, p = 0,0003]. Conclusões Ventilação com VLP2000E durante RCP é viável e equivalente a ventilação com bolsa-válvula quanto à taxa de RCE e saturação arterial de oxigênio. Esse ventilador produz melhores parâmetros respiratórios, com pressão das vias aéreas e volume corrente menores. Ventilação com VLP2000E também previne a redução significante da complacência pulmonar dinâmica observada após ventilação com bolsa-válvula. Seria interessante realizar mais estudos pré-clínicos para confirmar esses resultados.


Abstract Background For practical and protective ventilation during cardiopulmonary resuscitation (CPR), a 150-grams mechanical ventilator (VLP2000E) that limits peak inspiratory pressure (PIP) during simultaneous ventilation with chest compressions was developed. Objectives To evaluate the feasibility of VLP2000E ventilation during CPR and to compare monitored parameters versus bag-valve ventilation. Methods A randomized experimental study with 10 intubated pigs per group. After seven minutes of ventricular fibrillation, 2-minute CPR cycles were delivered. All animals were placed on VLP2000E after achieving return of spontaneous circulation (ROSC). Results Bag-valve and VLP2000E groups had similar ROSC rate (60% vs. 50%, respectively) and arterial oxygen saturation in most CPR cycles, different baseline tidal volume [0.764 (0.068) vs. 0.591 (0.123) L, p = 0.0309, respectively] and, in 14 cycles, different PIP [52 (9) vs. 39 (5) cm H2O, respectively], tidal volume [0.635 (0.172) vs. 0.306 (0.129) L], ETCO2[14 (8) vs. 27 (9) mm Hg], and peak inspiratory flow [0.878 (0.234) vs. 0.533 (0.105) L/s], all p < 0.0001. Dynamic lung compliance (≥ 0.025 L/cm H2O) decreased after ROSC in bag-valve group but was maintained in VLP2000E group [0.019 (0.006) vs. 0.024 (0.008) L/cm H2O, p = 0.0003]. Conclusions VLP2000E ventilation during CPR is feasible and equivalent to bag-valve ventilation in ROSC rate and arterial oxygen saturation. It produces better respiratory parameters, with lower airway pressure and tidal volume. VLP2000E ventilation also prevents the significant decrease of dynamic lung compliance observed after bag-valve ventilation. Further preclinical studies confirming these findings would be interesting.

3.
Endosc Int Open ; 9(7): E1049-E1054, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34222629

RESUMO

Background and study aims In the last decade, gastroenterologists have been attempting to use endoscopy to reproduce the great success of traditional surgical suture techniques. Despite recent advances, we still lack a reliable method that results in a permanent suture with minimal incidence of suture failure. This was an experimental study in pigs with an innovative technique that applied basic surgical concepts to endoscopy to evaluate the effectiveness of a novel suture technique. Methods The procedures were performed on six live pigs under general anesthesia. Endoscopic mucosal resection (EMR) first was performed in the stomach, exposing the submucosal or muscularis propria layers. A novel device, a transparent chamber cap (DASE), was developed to aspirate the gastric wall, allowing the sutures to reach deep layers. The aspiration was performed with a standard gastroscope to which the novel cap was distally attached. Three sutures aligned were defined as a plication. Each pig received two or three plications and was placed on a liquid diet for 14 days after the procedure. The pigs were sacrificed at 4 and 8 weeks and the sutures were reviewed. Results The technique was feasible in all animals. Of 16 plications, only one failed. One perforation occurred after EMR. There were no other complications or adverse events. Permanent fusion of the gastric wall was confirmed by histology in all cases. Conclusions This study showed that basic principles of surgery can be applied endoscopically to ensure a permanent suture with reduced chances of failure. These findings can help to pave the way for more effective bariatric endoscopic techniques.

4.
J Zoo Wildl Med ; 47(1): 17-24, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27010260

RESUMO

Established immobilization protocols are required for safe procedures on wildlife and zoo animals. This study evaluated the cardiovascular, respiratory, and anesthetic effects of dexmedetomidine (40 µg/kg) with S-ketamine (5 mg/kg) and midazolam (0.5 mg/kg) with S-ketamine (5 mg/kg) in 12 specimens of oncilla (Leopardus tigrinus) at Quinzinho de Barros Municipal Zoo Park in Sorocaba, São Paulo, Brazil, between January and March 2010. Each animal underwent both protocols, totaling 24 anesthetic procedures. The dexmedetomidine-S-ketamine group (DK) showed a decrease in heart rate compared to initial values and significantly lower heart rate and oxyhemoglobin saturation values compared to Midazolam-S-Ketamine Group (MK). Four animals in DK had episodes of sinus pauses. Systemic blood pressure, respiratory frequency, and rectal temperature showed no significant differences between groups. The dexmedetomidine-S-ketamine group showed a greater degree of muscle relaxation and allowed for more thorough and longer oral evaluations. The dexmedetomidine-S-ketamine group had a shorter period of recumbency, longer period to return of muscle tone, and shorter recovery time. Two animals in MK did not reach recumbency. The dexmedetomidine-S-ketamine group had better qualities of induction and recovery. It may be concluded that both protocols can be safely used in oncillas. Midazolam-S-ketamine promotes effective chemical restraint for quick and minimally invasive procedures and dexmedetomidine-S-ketamine promotes effective chemical restraint for prolonged and more invasive procedures.


Assuntos
Dexmedetomidina/farmacologia , Felidae , Imobilização/veterinária , Ketamina/farmacologia , Midazolam/farmacologia , Anestésicos Dissociativos/administração & dosagem , Anestésicos Dissociativos/farmacologia , Animais , Animais de Zoológico , Estudos Cross-Over , Dexmedetomidina/administração & dosagem , Combinação de Medicamentos , Feminino , Hipnóticos e Sedativos/administração & dosagem , Hipnóticos e Sedativos/farmacologia , Ketamina/administração & dosagem , Masculino , Midazolam/administração & dosagem
5.
J Vet Emerg Crit Care (San Antonio) ; 22(4): 409-18, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22731982

RESUMO

OBJECTIVE: To evaluate the changes in tissue perfusion parameters in dogs with severe sepsis/septic shock in response to goal-directed hemodynamic optimization in the ICU and their relation to outcome. DESIGN: Prospective observational study. SETTING: ICU of a veterinary university medical center. ANIMALS: Thirty dogs with severe sepsis or septic shock caused by pyometra who underwent surgery and were admitted to the ICU. MEASUREMENTS AND MAIN RESULTS: Severe sepsis was defined as the presence of sepsis and sepsis-induced dysfunction of one or more organs. Septic shock was defined as the presence of severe sepsis plus hypotension not reversed with fluid resuscitation. After the presumptive diagnosis of sepsis secondary to pyometra, blood samples were collected and clinical findings were recorded. Volume resuscitation with 0.9% saline solution and antimicrobial therapy were initiated. Following abdominal ultrasonography and confirmation of increased uterine volume, dogs underwent corrective surgery. After surgery, the animals were admitted to the ICU, where resuscitation was guided by the clinical parameters, central venous oxygen saturation (ScvO(2)), lactate, and base deficit. Between survivors and nonsurvivors it was observed that the ScvO(2), lactate, and base deficit on ICU admission were each related independently to death (P = 0.001, P = 0.030, and P < 0.001, respectively). ScvO(2) and base deficit were found to be the best discriminators between survivors and nonsurvivors as assessed via receiver operator characteristic curve analysis. CONCLUSION: Our study suggests that ScvO(2) and base deficit are useful in predicting the prognosis of dogs with severe sepsis and septic shock; animals with a higher ScvO(2) and lower base deficit at admission to the ICU have a lower probability of death.


Assuntos
Doenças do Cão/terapia , Oxigênio/sangue , Piometra/veterinária , Sepse/veterinária , Choque Séptico/veterinária , Animais , Antibacterianos/uso terapêutico , Biomarcadores , Cefalotina/uso terapêutico , Doenças do Cão/etiologia , Doenças do Cão/mortalidade , Cães , Dopamina/farmacologia , Feminino , Hidratação , Unidades de Terapia Intensiva , Metronidazol/uso terapêutico , Piometra/complicações , Ressuscitação , Sepse/mortalidade , Sepse/terapia , Choque Séptico/mortalidade , Choque Séptico/terapia , Resultado do Tratamento