1.
Photochem Photobiol ; 82(4): 844-9, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16724873

RESUMO

A solar radiometer (GUV-511 C, Biospherical Instruments Inc., San Diego, CA) with four UV channels has been operating at Trelew (43.2 degrees S, 65.3 degrees W), Argentina, since the austral spring of 1997. The instrument provides global (direct + diffuse) irradiance on the horizontal plane year-round, with a 1 min period. On 1 January 1999, an automatic shadow band was added to calculate diffuse and direct radiation. The period of the measurements was increased to 2 min to keep the same signal to noise (S:N) ratio. Once the direct radiation values were available for the 305 nm and 320 nm spectral bands, the total ozone value was calculated and results were compared with data provided by the U.S. National Aeronautics and Space Administration for the Total Ozone Mapping Spectrometer (TOMS) on the Earth Probe satellite. Results show a root-mean-square (RMS) deviation within 4% compared with that of TOMS, so the quality of results is considered to be quite good. The importance of regular calibration to maintain long-term accuracy is stressed.