Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Card Anaesth ; 24(4): 500-502, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34747766

RESUMO

A 69-year-old patient underwent an urgent aortic valve replacement because of Streptococcus agalactiae endocarditis of his native aortic valve. Since a rapid progression of the former abscess cavity into an aortic root pseudoaneurysm with increasing paravalvular regurgitation during postoperative follow-up, reoperation was performed. In the preoperative transesophageal echocardiography (TEE) images the pseudoaneurysm completely surrounds the left coronary artery (LCA) without any signs of myocardial ischemia.


Assuntos
Falso Aneurisma , Endocardite Bacteriana , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Reoperação
2.
Eur Heart J ; 38(26): 2048-2056, 2017 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-28065906

RESUMO

AIMS: Adult congenital heart disease (ACHD) predisposes to infective endocarditis (IE). Surgical advancements have changed the ACHD population, whereas associated prosthetic material may constitute additional IE targets. We aimed to prospectively determine contemporary incidence, risk factors, and predictors of IE in a nationwide ACHD cohort, focusing on the presence of prosthetics. METHODS AND RESULTS: We identified 14 224 patients prospectively followed in the CONCOR ACHD registry (50.5% female, median age 33.6years). IE incidence was determined using Poisson regression, risk factors and predictors using Cox regression. Overall incidence was 1.33 cases/1000 person-years (124 cases in 93 562 person-years). For risk-factor analysis, presence of prosthetics was forced-as separate time-updated variables for specific prosthetics-into a model with baseline characteristics univariably associated with IE. Valve-containing prosthetics were independently associated with greater risk both short- and long term after implantation [0-6 months: hazard ratio (HR) = 17.29; 7.34-40.70, 6-12 months: HR = 15.91; 6.76-37.45, beyond 12 months: HR = 5.26; 3.52-7.86], non-valve-containing prosthetics, including valve repair, only in the first 6 months after implantation (HR = 3.34; 1.33-8.41), not thereafter. A prediction model was derived and validated using bootstrapping techniques. Independent predictors of IE were baseline valve-containing prosthetics, main congenital heart defect, multiple defects, previous IE, and sex. The model had fair discriminative ability and provided accurate predictions up to 10 years. CONCLUSIONS: This study provides IE incidence estimates, and determinants of IE risk in a nationwide ACHD cohort. Our findings, essentially informing IE prevention guidelines, indicate valve-containing prosthetics as a main determinant of IE risk whereas other prosthetics, including valve-repair, are not associated with increased risk long term after implantation.


Assuntos
Endocardite/epidemiologia , Cardiopatias Congênitas/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Adulto , Estudos de Coortes , Endocardite/complicações , Europa (Continente)/epidemiologia , Feminino , Cardiopatias Congênitas/complicações , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/epidemiologia , Sistema de Registros , Fatores de Risco , Adulto Jovem
3.
Clin Res Cardiol ; 103(2): 133-40, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24136290

RESUMO

BACKGROUND: In this study, we sought to determine the effect of the mean transprosthetic pressure gradient (TPG), measured at 6 weeks after aortic valve replacement (AVR) or AVR with coronary artery bypass grafting (CABG) on late all-cause mortality. METHODS: Between January 1998 and March 2012, 2,276 patients (mean age 68 ± 11 years) underwent TPG analysis at 6 weeks after AVR (n = 1,318) or AVR with CABG (n = 958) at a single institution. Mean TPG was 11.6 ± 7.8 mmHg and median TPG 11 mmHg. Based on the TPG, the patients were split into three groups: patients with a low TPG (<10 mmHg), patients with a medium TPG (10-19 mmHg) and patients with a high TPG (≥ 20 mmHg). Cox proportional-hazard regression analysis was used to determine univariate predictors and multivariate independent predictors of late mortality. RESULTS: Overall survival for the entire group at 1, 3, 5, and 10 years was 97, 93, 87 and 67%, respectively. There was no significant difference in long-term survival between patients with a low, medium or high TPG (p = 0.258). Independent predictors of late mortality included age, diabetes, peripheral vascular disease, renal dysfunction, chronic obstructive pulmonary disease, a history of a cerebrovascular accident and cardiopulmonary bypass time. Prosthesis-patient mismatch (PPM), severe PPM and TPG measured at 6 weeks postoperatively were not significantly associated with late mortality. CONCLUSIONS: TPG measured at 6 weeks after AVR or AVR with CABG is not an independent predictor of all-cause late mortality and there is no significant difference in long-term survival between patients with a low, medium or high TPG.


Assuntos
Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Distribuição de Qui-Quadrado , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Feminino , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Países Baixos , Modelos de Riscos Proporcionais , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
J Cardiothorac Surg ; 8: 96, 2013 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-23594366

RESUMO

BACKGROUND: The influence of prosthesis-patient mismatch (PPM) on survival after aortic valve replacement (AVR) remains controversial. In this study, we sought to determine the effect of PPM on early (≤30 days) and late mortality (>30 days) after AVR or AVR combined with coronary artery bypass grafting (AVR with CABG). METHODS: Between January 1998 and March 2012, 2976 patients underwent AVR (n= 1718) or AVR with CABG (n=1258) at a single institution. PPM was defined as an indexed effective orifice area (EOAI) ≤0.85 cm2/m2 and patients were divided into two groups based on the existence of PPM. Cumulative probability values of survival were estimated with Kaplan-Meier method and compared between groups using Breslow test. Univariate and multivariate independent predictors of early mortality were identified using logistic regression. Cox proportional-hazard regression analysis was used to determine univariate and multivariate independent predictors of late mortality. RESULTS: Early mortality was 6.7% in the PPM group vs 4.7% in the group with no PPM (p=0.013). Late mortality for the PPM group at 1, 5 and 10 years was 4%, 16% and 43%, respectively. Late mortality for the group with no PPM at 1, 5 and 10 years was 4%, 15% and 33% respectively. Independent predictors of early mortality included age, severely impaired left ventricular (LV) function, endocarditis, renal dysfunction, chronic obstructive pulmonary disease (COPD) and cardiopulmonary bypass (CPB) time. Multivariate independent predictors of late mortality included age, severely impaired LV function, diabetes, peripheral vascular disease (PVD), renal dysfunction, history of a cerebrovascular accident (CVA), CPB time and a history of previous cardiac surgery. PPM was not an independent predictor of early or late mortality. CONCLUSION: PPM is not an independent predictor of both early and late mortality after AVR or AVR combined with CABG.


Assuntos
Valva Aórtica/cirurgia , Ponte de Artéria Coronária/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Próteses Valvulares Cardíacas/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...