Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Neurosci ; 26(4): 579-593, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36997759

RESUMO

Cortical state, defined by population-level neuronal activity patterns, determines sensory perception. While arousal-associated neuromodulators-including norepinephrine (NE)-reduce cortical synchrony, how the cortex resynchronizes remains unknown. Furthermore, general mechanisms regulating cortical synchrony in the wake state are poorly understood. Using in vivo imaging and electrophysiology in mouse visual cortex, we describe a critical role for cortical astrocytes in circuit resynchronization. We characterize astrocytes' calcium responses to changes in behavioral arousal and NE, and show that astrocytes signal when arousal-driven neuronal activity is reduced and bi-hemispheric cortical synchrony is increased. Using in vivo pharmacology, we uncover a paradoxical, synchronizing response to Adra1a receptor stimulation. We reconcile these results by demonstrating that astrocyte-specific deletion of Adra1a enhances arousal-driven neuronal activity, while impairing arousal-related cortical synchrony. Our findings demonstrate that astrocytic NE signaling acts as a distinct neuromodulatory pathway, regulating cortical state and linking arousal-associated desynchrony to cortical circuit resynchronization.


Assuntos
Astrócitos , Norepinefrina , Camundongos , Animais , Astrócitos/metabolismo , Norepinefrina/metabolismo , Neurônios/fisiologia , Nível de Alerta/fisiologia , Neurotransmissores/metabolismo
2.
Neurophotonics ; 8(1): 015003, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33437848

RESUMO

Significance: To expand our understanding of the roles of astrocytes in neural circuits, there is a need to develop optical tools tailored specifically to capture their complex spatiotemporal Ca 2 + dynamics. This interest is not limited to 2D, but to multiple depths. Aim: The focus of our work was to design and evaluate the optical performance of an enhanced version of a two-photon (2P) microscope with the addition of a deformable mirror (DM)-based axial scanning system for live mammalian brain imaging. Approach: We used a DM to manipulate the beam wavefront by applying different defocus terms to cause a controlled axial shift of the image plane. The optical design and performance were evaluated by an analysis of the optical model, followed by an experimental characterization of the implemented instrument. Results: Key questions related to this instrument were addressed, including impact of the DM curvature change on vignetting, field of view size, image plane flatness, wavefront error, and point spread function. The instrument was used for imaging several neurobiological samples at different depths, including fixed brain slices and in vivo mouse cerebral cortex. Conclusions: Our implemented instrument was capable of recording z -stacks of 53 µ m in depth with a fine step size, parameters that make it useful for astrocyte biology research. Future work includes adaptive optics and intensity normalization.

3.
Opt Express ; 24(21): 24032-24044, 2016 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-27828235

RESUMO

The aim of this article is to determine the best dielectric between SiO2, Si3N4 and TiO2 for quantum cascade laser (QCL) passivation layers depending on the operation wavelength. It relies on both Mueller ellipsometry measurement to accurately determine the optical constants (the refractive index n and the extinction coefficient k) of the three dielectrics, and optical simulations to determine the mode overlap with the dielectric and furthermore the modal losses in the passivation layer. The impact of dielectric thermal conductivities are taken into account and shown to be not critical on the laser performances.

4.
ACS Appl Mater Interfaces ; 8(23): 14701-8, 2016 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-27188403

RESUMO

Recent improvement in the performance of the n-type organic semiconductors as well as thin gate dielectrics based on cross-linked polymers offers new opportunities to develop high-performance low-voltage n-type OFETs suitable for organic complementary circuits. Using TIPS-tetracyanotriphenodioxazine (TIPS-TPDO-tetraCN) and cross-linked poly(methyl methacrylate) (c-PMMA), respectively as n-type organic semiconductor and gate dielectric, linear regime field-effect mobility (1.8 ± 0.2) × 10(-2) cm(2) V(-1)s(-1), small spatial standard deviation of threshold voltage (∼0.1 V), and operating voltage less than 3 V are attainable with the same device structure and contact materials used commonly for p-type OFETs. Through comparative static and dynamic characterizations of c-PMMA and PMMA gate dielectrics, it is shown that both smaller thickness and larger relative permittivity of c-PMMA contributes to reduced operating voltage. Furthermore, negligible hysteresis brings evidence to small trap states in the semiconductor near gate dielectric of the n-type OFETs with c-PMMA. The use of TIPS-TPDO-tetraCN and c-PMMA is fully compatible with polyethylene terephthalate substrate, giving promise to various flexible applications.

5.
Opt Lett ; 40(16): 3790-3, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-26274661

RESUMO

An optical setup able to generate arbitrary states of polarization (SOPs) with customized degree of polarization is presented in this Letter. Compared with the few alternatives existing in literature, it presents an easy-to-build optical setup and leads to a superior performance. In fact, experimental results are presented, providing an accurate control for the generation of SOPs (maximum error of 1.7% and 3.3% for ellipticity and azimuth, respectively) as well as for the associated degree of polarization (full experimental variation from 1 up to 0.003, with a 1.7% maximum error). The system proposed may be useful for different applications, for example, for polarimeters testing, speckle metrology, and biological applications.

6.
Opt Express ; 23(14): 18080-91, 2015 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-26191867

RESUMO

The interest on the conical refraction (CR) phenomenon in biaxial crystals has revived in the last years due to its prospective for generating structured polarized light beams, i.e. vector beams. While the intensity and the polarization structure of the CR beams are well known, an accurate experimental study of their phase structure has not been yet carried out. We investigate the phase structure of the CR rings by means of a Mach-Zehnder interferometer while applying the phase-shifting interferometric technique to measure the phase at the focal plane. In general the two beams interfering correspond to different states of polarization (SOP) which locally vary. To distinguish if there is an additional phase added to the geometrical one we have derived the appropriate theoretical expressions using the Jones matrix formalism. We demonstrate that the phase of the CR rings is equivalent to that one introduced by an azimuthally segmented polarizer with CR-like polarization distribution. Additionally, we obtain direct evidence that the Poggendorff dark ring is an annular singularity, with a π phase change between the inner and outer bright rings.

7.
Opt Express ; 23(5): 5636-52, 2015 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-25836795

RESUMO

Recently, we introduced the basic concepts behind a new polarimeter device based on conical refraction (CR), which presents several appealing features compared to standard polarimeters. To name some of them, CR polarimeters retrieve the polarization state of an input light beam with a snapshot measurement, allow for substantially enhancing the data redundancy without increasing the measuring time, and avoid instrumental errors owing to rotating elements or phase-to-voltage calibration typical from dynamic devices. In this article, we present a comprehensive study of the optimization, robustness and parameters tolerance of CR based polarimeters. In addition, a particular CR based polarimetric architecture is experimentally implemented, and some concerns and recommendations are provided. Finally, the implemented polarimeter is experimentally tested by measuring different states of polarization, including fully and partially polarized light.

8.
Opt Lett ; 39(3): 659-62, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24487892

RESUMO

We propose a new technique that is able to generate a light beam with a controlled state of polarization (SoP) and a customized degree of polarization (DoP). The technique relies on the fact that effective depolarization can be achieved by temporally averaging a time-dependent SoP. Our proposed setup is based on a ferroelectric liquid crystal panel of retardance λ/2, with a fast polarization switching capability (33 Hz). A mathematical basis describing the experiment is given. In addition, simulation data is discussed, showing the possibility of generating any SoP with full control of the DoP. Finally, to prove the potential of the invention proposed, experimental results are provided as well, reaching an experimental minimum DoP of 0.14.

9.
Opt Lett ; 38(20): 4100-3, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24321933

RESUMO

A method for polarization metrology based on the conical refraction (CR) phenomenon, occurring in biaxial crystals, is reported. CR transforms an input Gaussian beam into a light ring whose intensity distribution is linked to the incoming polarization. We present the design of a division-of-amplitude complete polarimeter composed of two biaxial crystals, whose measurement principle is based on the CR phenomenon. This design corresponds to a static polarimeter, that is, without mechanical movements or electrical signal addressing. Only one division-of-amplitude device is required, besides the two biaxial crystals, to completely characterize any state of polarization, including partially polarized and unpolarized states. In addition, a mathematical model describing the system is included. Experimental images of the intensity distribution related to different input polarization states are provided. These intensity patterns are compared with simulated values, proving the potential of polarimeters based on biaxial crystals.

10.
Appl Opt ; 52(23): 5748-57, 2013 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-23938428

RESUMO

We present the design of Stokes and Mueller polarimeters based on ferroelectric liquid crystal (FLC) panels. The instrument is complete and takes time-sequential measurements. A FLC device is modeled as a uniaxial birefringent waveplate with two stable optical axis orientations switchable by a squared electrical signal. The optical parameters of the LC device (retardance and the two stable orientations of the fast axis) are calibrated. Then the orientations of the optical elements of the setup are optimized in order to minimize the propagation of the noise. We also provide a tolerance study to achieve 2% accuracy for the Stokes vector and Mueller matrix metrology. These analyses are conducted as a function of the incident state of polarization and of the Mueller matrix to be measured, respectively. The optimized system is implemented and calibrated in the laboratory. We evaluate its repeatability over 24 h of operation, and the dependence with the temperature is discussed. In addition, we include a study related to the speed of taking the measurements. Finally, we provide some experimental measurements of different Stokes vectors and Mueller matrices, validating the proposed prototypes.

11.
Opt Express ; 20(25): 27393-409, 2012 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-23262690

RESUMO

A division-of-focal-plane polarimeter based on a dichroic dye and liquid crystal polymer guest-host system is presented. Two Stokes polarimeters are demonstrated: a linear Stokes and the first ever Full-Stokes division-of-focal-plane polarimeter. The fabrication, packaging, and characterization of the systems are presented. Finally, optimized polarimeter designs are discussed for future works.


Assuntos
Modelos Teóricos , Polímeros , Refratometria/instrumentação , Refratometria/métodos , Compostos de Boro/química , Calibragem , Desenho de Equipamento , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Silicatos/química
12.
Appl Opt ; 50(28): 5437-45, 2011 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22016210

RESUMO

This work evidences the suitability of applying a single twisted nematic liquid-crystal (TN-LC) device to obtain dynamic polarimeters with high accuracy and repeatability. Different Stokes polarimeter setups based on a TN-LC device are optimized, leading to the minimization of the noise propagated from intensity measurements to the Stokes vector calculations. To this aim, we revise the influence of working out of normal incidence and of performing a double pass of the light beam through the LC device. In addition, because transmissive TN-LC devices act as elliptical retarders, an extra study is performed. It analyzes the influence of projecting the light exiting from the TN-LC device over elliptical states of polarization. Finally, diverse optimized polarimeters are experimentally implemented and validated by measuring different states of partially and fully polarized light. The analysis is conducted both for monochromatic (He-Ne laser) and LED light sources, proving the potential of polarimeters based on a single TN-LC device.

13.
Opt Express ; 18(10): 9815-30, 2010 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-20588831

RESUMO

In this paper we present the analysis, optimization and implementation of several Stokes polarimeter configurations based on a set-up including two variable retarders. The polarimeter analysis is based on the Mueller-Stokes formalism, and as a consequence, it is suitable to deal with depolarized light. Complete Stokes polarimeters are optimized by minimizing the amplification of simulated errors into the final solution. Different indicators useful to achieve this aim, as the condition number or the equally weighted variance, are compared in this paper. Moreover, some of the optimized polarimeters are experimentally implemented and it is studied the influence of small deviations from the theoretical ones on the amplification of the Stokes component error. In addition, the benefit of using incomplete polarimeters, when detecting specific ranges of states of polarization, is discussed.


Assuntos
Dispositivos Ópticos , Refratometria/métodos , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Modelos Teóricos , Refratometria/instrumentação , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA