Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Commun Biol ; 7(1): 226, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38396068

RESUMO

The human brain can encode auditory regularities with fixed sound-to-sound intervals and with sound onsets locked to cardiac inputs. Here, we investigated auditory and cardio-audio regularity encoding during sleep, when bodily and environmental stimulus processing may be altered. Using electroencephalography and electrocardiography in healthy volunteers (N = 26) during wakefulness and sleep, we measured the response to unexpected sound omissions within three regularity conditions: synchronous, where sound and heartbeat are temporally coupled, isochronous, with fixed sound-to-sound intervals, and a control condition without regularity. Cardio-audio regularity encoding manifested as a heartbeat deceleration upon omissions across vigilance states. The synchronous and isochronous sequences induced a modulation of the omission-evoked neural response in wakefulness and N2 sleep, the former accompanied by background oscillatory activity reorganization. The violation of cardio-audio and auditory regularity elicits cardiac and neural responses across vigilance states, laying the ground for similar investigations in altered consciousness states such as coma and anaesthesia.


Assuntos
Eletroencefalografia , Vigília , Humanos , Vigília/fisiologia , Sono/fisiologia , Encéfalo/fisiologia , Som
2.
Artigo em Inglês | MEDLINE | ID: mdl-38082665

RESUMO

This study characterizes the neurophysiological mechanisms underlying electromagnetic imaging signals using stability analysis. Researchers have proposed that transitions between conscious awake and anaesthetised states, and other brain states more generally, may result from system stability changes. The concept of stability in dynamical systems theory provides a mathematical framework to describe this possibility. In particular, the degree to which a system's trajectory in phase space is affected by small perturbations determines the stability. Previous studies using linear or oscillator-based whole-brain models cannot represent complex cerebrocortical dynamics, or model parameters were pre-assumed or inferred from data but did not change over time. This study proposes a nonlinear neurophysiologically plausible whole-cortex modeling framework to analyze the stability of brain dynamics for the emergence and disappearance of consciousness using time-varying parameters estimated from the data.Clinical relevance- Depth of anaesthesia is typically measured through changes in EEG statistics like the bispectral index and spectral entropy. However, these monitors have been found to fail in preventing awareness during surgery and postoperative recall. Our whole-cortex stability analysis may be useful in measuring anaesthesia levels in clinical settings, as it changes with the level of consciousness and is independent of individual differences and anaesthetic agents. The proposed method can also be used to, for example, identify critical brain regions for consciousness, locate the epileptogenic zone and investigate the dominance of extrinsic or intrinsic factors in brain functions.


Assuntos
Anestesia , Anestésicos , Humanos , Xenônio , Eletroencefalografia/métodos , Encéfalo/fisiologia
3.
Brain Commun ; 5(4): fcad190, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37469860

RESUMO

Early prognostication of long-term outcome of comatose patients after cardiac arrest remains challenging. Electroencephalography-based power spectra after cardiac arrest have been shown to help with the identification of patients with favourable outcome during the first day of coma. Here, we aim at comparing the power spectra prognostic value during the first and second day after coma onset following cardiac arrest and to investigate the impact of sedation on prognostication. In this cohort observational study, we included comatose patients (N = 91) after cardiac arrest for whom resting-state electroencephalography was collected on the first and second day after cardiac arrest in four Swiss hospitals. We evaluated whether the average power spectra values at 4.6-15.2 Hz were predictive of patients' outcome based on the best cerebral performance category score at 3 months, with scores ranging from 1 to 5 and dichotomized as favourable (1-2) and unfavourable (3-5). We assessed the effect of sedation and its interaction with the electroencephalography-based power spectra on patient outcome prediction through a generalized linear mixed model. Power spectra values provided 100% positive predictive value (95% confidence intervals: 0.81-1.00) on the first day of coma, with correctly predicted 18 out of 45 favourable outcome patients. On the second day, power spectra values were not predictive of patients' outcome (positive predictive value: 0.46, 95% confidence intervals: 0.19-0.75). On the first day, we did not find evidence of any significant contribution of sedative infusion rates to the patient outcome prediction (P > 0.05). Comatose patients' outcome prediction based on electroencephalographic power spectra is higher on the first compared with the second day after cardiac arrest. Sedation does not appear to impact patient outcome prediction.

4.
Int J Neural Syst ; 33(5): 2350024, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37103982

RESUMO

Recent work presented a framework for space-time-resolved neurophysiological process imaging that augments existing electromagnetic source imaging techniques. In particular, a nonlinear Analytic Kalman filter (AKF) has been developed to efficiently infer the states and parameters of neural mass models believed to underlie the generation of electromagnetic source currents. Unfortunately, as the initialization determines the performance of the Kalman filter, and the ground truth is typically unavailable for initialization, this framework might produce suboptimal results unless significant effort is spent on tuning the initialization. Notably, the relation between the initialization and overall filter performance is only given implicitly and is expensive to evaluate; implying that conventional optimization techniques, e.g. gradient or sampling based, are inapplicable. To address this problem, a novel efficient framework based on blackbox optimization has been developed to find the optimal initialization by reducing the signal prediction error. Multiple state-of-the-art optimization methods were compared and distinctively, Gaussian process optimization decreased the objective function by 82.1% and parameter estimation error by 62.5% on average with the simulation data compared to no optimization applied. The framework took only 1.6[Formula: see text]h and reduced the objective function by an average of 13.2% on 3.75[Formula: see text]min 4714-source channel magnetoencephalography data. This yields an improved method of neurophysiological process imaging that can be used to uncover complex underpinnings of brain dynamics.


Assuntos
Algoritmos , Encéfalo , Simulação por Computador , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia
5.
Neuroimage ; 263: 119592, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36031185

RESUMO

Neural processes are complex and difficult to image. This paper presents a new space-time resolved brain imaging framework, called Neurophysiological Process Imaging (NPI), that identifies neurophysiological processes within cerebral cortex at the macroscopic scale. By fitting uncoupled neural mass models to each electromagnetic source time-series using a novel nonlinear inference method, population averaged membrane potentials and synaptic connection strengths are efficiently and accurately inferred and imaged across the whole cerebral cortex at a resolution afforded by source imaging. The efficiency of the framework enables return of the augmented source imaging results overnight using high performance computing. This suggests it can be used as a practical and novel imaging tool. To demonstrate the framework, it has been applied to resting-state magnetoencephalographic source estimates. The results suggest that endogenous inputs to cingulate, occipital, and inferior frontal cortex are essential modulators of resting-state alpha power. Moreover, endogenous input and inhibitory and excitatory neural populations play varied roles in mediating alpha power in different resting-state sub-networks. The framework can be applied to arbitrary neural mass models and has broad applicability to image neural processes of different brain states.


Assuntos
Ritmo alfa , Imageamento por Ressonância Magnética , Humanos , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Magnetoencefalografia , Mapeamento Encefálico
6.
Front Neurosci ; 16: 874023, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35527816

RESUMO

Purpose: We present a novel approach that allows the estimation of morphological features of axonal fibers from data acquired in vivo in humans. This approach allows the assessment of white matter microscopic properties non-invasively with improved specificity. Theory: The proposed approach is based on a biophysical model of Magnetic Resonance Imaging (MRI) data and of axonal conduction velocity estimates obtained with Electroencephalography (EEG). In a white matter tract of interest, these data depend on (1) the distribution of axonal radius [P(r)] and (2) the g-ratio of the individual axons that compose this tract [g(r)]. P(r) is assumed to follow a Gamma distribution with mode and scale parameters, M and θ, and g(r) is described by a power law with parameters α and ß. Methods: MRI and EEG data were recorded from 14 healthy volunteers. MRI data were collected with a 3T scanner. MRI-measured g-ratio maps were computed and sampled along the visual transcallosal tract. EEG data were recorded using a 128-lead system with a visual Poffenberg paradigm. The interhemispheric transfer time and axonal conduction velocity were computed from the EEG current density at the group level. Using the MRI and EEG measures and the proposed model, we estimated morphological properties of axons in the visual transcallosal tract. Results: The estimated interhemispheric transfer time was 11.72 ± 2.87 ms, leading to an average conduction velocity across subjects of 13.22 ± 1.18 m/s. Out of the 4 free parameters of the proposed model, we estimated θ - the width of the right tail of the axonal radius distribution - and ß - the scaling factor of the axonal g-ratio, a measure of fiber myelination. Across subjects, the parameter θ was 0.40 ± 0.07 µm and the parameter ß was 0.67 ± 0.02 µm-α. Conclusion: The estimates of axonal radius and myelination are consistent with histological findings, illustrating the feasibility of this approach. The proposed method allows the measurement of the distribution of axonal radius and myelination within a white matter tract, opening new avenues for the combined study of brain structure and function, and for in vivo histological studies of the human brain.

7.
Anesthesiology ; 132(5): 1017-1033, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32032094

RESUMO

BACKGROUND: Investigations of the electrophysiology of gaseous anesthetics xenon and nitrous oxide are limited revealing inconsistent frequency-dependent alterations in spectral power and functional connectivity. Here, the authors describe the effects of sedative, equivalent, stepwise levels of xenon and nitrous oxide administration on oscillatory source power using a crossover design to investigate shared and disparate mechanisms of gaseous xenon and nitrous oxide anesthesia. METHODS: Twenty-one healthy males underwent simultaneous magnetoencephalography and electroencephalography recordings. In separate sessions, sedative, equivalent subanesthetic doses of gaseous anesthetic agents nitrous oxide and xenon (0.25, 0.50, and 0.75 equivalent minimum alveolar concentration-awake [MACawake]) and 1.30 MACawake xenon (for loss of responsiveness) were administered. Source power in various frequency bands were computed and statistically assessed relative to a conscious/pre-gas baseline. RESULTS: Observed changes in spectral-band power (P < 0.005) were found to depend not only on the gas delivered, but also on the recording modality. While xenon was found to increase low-frequency band power only at loss of responsiveness in both source-reconstructed magnetoencephalographic (delta, 208.3%, 95% CI [135.7, 281.0%]; theta, 107.4%, 95% CI [63.5, 151.4%]) and electroencephalographic recordings (delta, 260.3%, 95% CI [225.7, 294.9%]; theta, 116.3%, 95% CI [72.6, 160.0%]), nitrous oxide only produced significant magnetoencephalographic high-frequency band increases (low gamma, 46.3%, 95% CI [34.6, 57.9%]; high gamma, 45.7%, 95% CI [34.5, 56.8%]). Nitrous oxide-not xenon-produced consistent topologic (frontal) magnetoencephalographic reductions in alpha power at 0.75 MACawake doses (44.4%; 95% CI [-50.1, -38.6%]), whereas electroencephalographically nitrous oxide produced maximal reductions in alpha power at submaximal levels (0.50 MACawake, -44.0%; 95% CI [-48.1,-40.0%]). CONCLUSIONS: Electromagnetic source-level imaging revealed widespread power changes in xenon and nitrous oxide anesthesia, but failed to reveal clear universal features of action for these two gaseous anesthetics. Magnetoencephalographic and electroencephalographic power changes showed notable differences which will need to be taken into account to ensure the accurate monitoring of brain state during anaesthesia.


Assuntos
Anestésicos Inalatórios/administração & dosagem , Córtex Cerebral/efeitos dos fármacos , Córtex Cerebral/diagnóstico por imagem , Estado de Consciência/efeitos dos fármacos , Óxido Nitroso/administração & dosagem , Xenônio/administração & dosagem , Adulto , Córtex Cerebral/fisiologia , Estado de Consciência/fisiologia , Estudos Cross-Over , Eletroencefalografia/efeitos dos fármacos , Eletroencefalografia/métodos , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética/métodos , Magnetoencefalografia/efeitos dos fármacos , Magnetoencefalografia/métodos , Masculino , Método Simples-Cego , Adulto Jovem
8.
J Vis Exp ; (131)2018 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-29364232

RESUMO

Anesthesia arguably provides one of the only systematic ways to study the neural correlates of global consciousness/unconsciousness. However to date most neuroimaging or neurophysiological investigations in humans have been confined to the study of γ-Amino-Butyric-Acid-(GABA)-receptor-agonist-based anesthetics, while the effects of dissociative N-Methyl-D-Aspartate-(NMDA)-receptor-antagonist-based anesthetics ketamine, nitrous oxide (N2O) and xenon (Xe) are largely unknown. This paper describes the methods underlying the simultaneous recording of magnetoencephalography (MEG) and electroencephalography (EEG) from healthy males during inhalation of the gaseous anesthetic agents N2O and Xe. Combining MEG and EEG data enables the assessment of electromagnetic brain activity during anesthesia at high temporal, and moderate spatial, resolution. Here we describe a detailed protocol, refined over multiple recording sessions, that includes subject recruitment, anesthesia equipment setup in the MEG scanner room, data collection and basic data analysis. In this protocol each participant is exposed to varying levels of Xe and N2O in a repeated measures cross-over design. Following relevant baseline recordings participants are exposed to step-wise increasing inspired concentrations of Xe and N2O of 8, 16, 24 and 42%, and 16, 32 and 47% respectively, during which their level of responsiveness is tracked with an auditory continuous performance task (aCPT). Results are presented for a number of recordings to highlight the sensor-level properties of the raw data, the spectral topography, the minimization of head movements, and the unequivocal level dependent effects on the auditory evoked responses. This paradigm describes a general approach to the recording of electromagnetic signals associated with the action of different kinds of gaseous anesthetics, which can be readily adapted to be used with volatile and intravenous anesthetic agents. It is expected that the method outlined can contribute to the understanding of the macro-scale mechanisms of anesthesia by enabling methodological extensions involving source space imaging and functional network analysis.


Assuntos
Anestésicos Inalatórios/administração & dosagem , Encéfalo/efeitos dos fármacos , Encéfalo/fisiologia , Eletroencefalografia/métodos , Magnetoencefalografia/métodos , Óxido Nitroso/administração & dosagem , Xenônio/administração & dosagem , Adulto , Anestésicos Inalatórios/farmacologia , Fenômenos Eletromagnéticos , Voluntários Saudáveis , Humanos , Masculino , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...