Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rapid Commun Mass Spectrom ; 34 Suppl 3: e8747, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32056289

RESUMO

RATIONALE: Ambient mass spectrometry techniques are much required in forensic chemistry to evaluate evidence with low analytical interference, high confidence, and accuracy. However, traditional methodologies, such as paper spray ionization, have been shown to present low sensitivity in the analysis of illicit drugs from biological matrices. METHODS: Fiber spray ionization mass spectrometry (FSI-MS) was developed using a capillary polypropylene (PP) hollow fiber. Seized samples of drugs, i.e. a tablet, blotter paper, hashish, and cocaine powder, were analyzed. Cocaine was quantified from whole urine by dipping the fiber directly into solution. FSI-MS was tested for the analysis of a sample of urine obtained from a drug abuse suspect. RESULTS: The FSI(+) analysis showed the detection of different types of synthetic drugs in tablet and blotter paper samples, e.g. amphetamine, cathinones, phenethylamines, and opioids, while pure cocaine and different types of coca alkaloids were identified from cocaine powder with good sensitivity and high mass accuracy. The hashish analysis by FSI(-) revealed signals of cannabinoids, cannabinoid acids, and cannabinoid derivatives, detected mainly as [M - H]- ions or chlorine adducts [M + Cl]- . The quantification of cocaine in whole urine showed good sensitivity and precision with limits of detection and quantification of 5.16 and 17.21 ng/mL, respectively, linearity above 0.999, and relative standard deviation below 2.71%. The evaluation of seized sample of urine showed the detection of cocaine with relative ion intensity greater than 36%, as well as the metabolites benzoylecgonine and cocaethylene with a relative intensity of 1.4% and 6%, respectively. CONCLUSIONS: The developed FSI-MS method has the potential to be applied to forensic sample evaluation as well as to determine illicit drugs from biological matrices in toxicological analysis. The use of a capillary PP fiber has advantages as an extractor agent and ionizing substrate, and also the feature of it being dipped directly into the sample, thus preserving the integrity of the sample, which makes this a very promising ambient mass spectrometry method and relevant to forensic chemistry.


Assuntos
Cocaína/urina , Drogas Ilícitas/análise , Espectrometria de Massas/métodos , Analgésicos Opioides/análise , Canabinoides/análise , Cannabis , Cocaína/análogos & derivados , Cocaína/análise , Ciências Forenses , Humanos , Drogas Ilícitas/urina , Limite de Detecção , N-Metil-3,4-Metilenodioxianfetamina/análise , Sensibilidade e Especificidade , Solventes/química , Detecção do Abuso de Substâncias/métodos , Comprimidos
2.
Neurotox Res ; 34(4): 834-847, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28914428

RESUMO

When burning crack cocaine, the pyrolysis of cocaine generates anhydroecgonine methyl ester (AEME). AEME has been shown to be highly neurotoxic but its effects on cognitive function and oxidative stress are still unknown. Thus, this study investigated the effects of AEME on spatial working memory and on parameters of oxidative stress in the prefrontal cortex, hippocampus, and striatum. First, 18 well-trained rats in 8-arm radial maze (8-RM) procedures received acute intracerebroventricular (icv) administration of AEME at doses of 10, 32, or 100 µg or saline (SAL) in a counterbalanced order and were tested 5 min later in 1-h delayed tasks in the 8-RM. Secondly, separated animals received acute icv administration of AEME at doses of 10 (n = 5), 32 (n = 5), or 100 µg (n = 5) or SAL (n = 5) for analysis of advanced oxidation protein products, thiobarbituric acid, catalase, glutathione peroxidase, and superoxide dismutase. A higher number of errors were seen in the 1-h post-delay performance after AEME 32 µg and AEME 100 µg when compared to SAL. In the striatum, animals receiving AEME 100 µg icv showed increased advanced oxidation protein products levels when compared to 10 µg, and also showed increased activity of glutathione peroxidase enzyme when compared to SAL but also comparing to AEME 32 µg and AEME 10 µg. These results showed that AEME impairs long-term spatial working memory and also induces greater protein oxidation and increased levels of antioxidant enzymes in the striatum.


Assuntos
Cocaína/análogos & derivados , Corpo Estriado/efeitos dos fármacos , Transtornos da Memória/induzido quimicamente , Memória de Curto Prazo/efeitos dos fármacos , Estresse Oxidativo/efeitos dos fármacos , Memória Espacial/efeitos dos fármacos , Animais , Cocaína/química , Cocaína/toxicidade , Corpo Estriado/metabolismo , Relação Dose-Resposta a Droga , Hipocampo/efeitos dos fármacos , Hipocampo/metabolismo , Masculino , Transtornos da Memória/metabolismo , Memória de Curto Prazo/fisiologia , Estresse Oxidativo/fisiologia , Córtex Pré-Frontal/efeitos dos fármacos , Córtex Pré-Frontal/metabolismo , Ratos Wistar , Memória Espacial/fisiologia
3.
J Psychiatr Res ; 91: 57-63, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28314129

RESUMO

Crack cocaine (crack) addiction represents a major social and health burden, especially seeing as users are more prone to engage in criminal and violent acts. Crack users show a higher prevalence of psychiatric comorbidities - particularly antisocial personality disorders - when compared to powder cocaine users. They also develop cognitive deficits related mainly to executive functions, including working memory. It is noteworthy that stimulant drugs can induce psychotic states, which appear to mimic some symptoms of schizophrenia among users. Social withdraw and executive function deficits are, respectively, negative and cognitive symptoms of schizophrenia mediated by reduced dopamine (DA) tone in the prefrontal cortex (PFC) of patients. That could be explained by an increased expression of D2R short isoform (D2S) in the PFC of such patients and/or by hypofunctioning NMDA receptors in this region. Reduced DA tone has already been described in the PFC of mice exposed to crack smoke. Therefore, it is possible that behavioral alterations presented by crack users result from molecular and biochemical neuronal alterations akin to schizophrenia. Accordingly, we found that upon crack inhalation mice have shown decreased social interaction and working memory deficits analogous to schizophrenia's symptoms, along with increased D2S/D2L expression ratio and decreased expression of NR1, NR2A and NR2B NMDA receptor subunits in the PFC. Herein we propose two possible mechanisms to explain the reduced DA tone in the PFC elicited by crack consumption in mice, bringing also the first direct evidence that crack use may result in schizophrenia-like neurochemical, molecular and behavioral alterations.


Assuntos
Cocaína Crack/toxicidade , Regulação da Expressão Gênica/efeitos dos fármacos , Córtex Pré-Frontal/metabolismo , Receptores de Dopamina D2/metabolismo , Receptores de N-Metil-D-Aspartato/metabolismo , Esquizofrenia/induzido quimicamente , Animais , Modelos Animais de Doenças , Relações Interpessoais , Masculino , Aprendizagem em Labirinto , Transtornos da Memória/induzido quimicamente , Memória de Curto Prazo/efeitos dos fármacos , Camundongos , Camundongos Endogâmicos C57BL , Córtex Pré-Frontal/efeitos dos fármacos , Isoformas de Proteínas/metabolismo , Receptores de Dopamina D2/genética , Receptores de N-Metil-D-Aspartato/genética , Esquizofrenia/complicações , Esquizofrenia/patologia , Psicologia do Esquizofrênico
4.
Traffic Inj Prev ; 17(7): 663-7, 2016 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-26891425

RESUMO

OBJECTIVE: The objective of this study was to determine the prevalence of alcohol and illicit drug use among victims of fatal traffic accidents in the Metropolitan Region of Vitória, Brazil, during the period 2011-2012. METHODS: Blood samples were collected and analyzed for the presence of drugs from 391 deceased victims of traffic crashes that occurred in the Metropolitan Region of Vitória, Brazil. The victims included drivers, passengers, and pedestrians. Sociodemographic variables such as age, gender, day of the week, and period of the year in which the accidents occurred were recorded. The analyses were performed by a gas chromatography-flame ionization method for alcohol and by a gas chromatography-mass spectrometry for amphetamines, cocaine, and cannabis. RESULTS: The results showed that 44.8% (n = 175) of all cases were positive for alcohol and/or illicit drugs. The detection of alcohol and/or drugs was more frequent in young males, aged 17 to 34, whose samples were positive in 46.8% of cases. Small differences among drivers, passengers, and pedestrians were observed (drivers = 45.9%, passengers = 46.4%, and pedestrians = 45.6%). In general, the most prevalent drug was alcohol, with 141 positive cases (36.1%), followed by cocaine, with 47 positive cases (12%). Amphetamines and cannabis had positivity rates of 4.1 and 4.3%, with 16 and 17 positive cases, respectively. The combined use of alcohol and other drugs was found in 36 cases (9.2%). Crack cocaine use was observed in 27.7% of the positive cases for cocaine. CONCLUSIONS: For the effective reduction of traffic accidents related to driving under influence of drugs (DUID), we suggest the intensification of enforcement actions against the use of alcohol by drivers, the definition of which illicit drugs should be surveyed, as well the cutoff values, the promotion of changing legislation to oblige drivers to provide samples for toxicological testing, and the establishment of public information programs and specific actions aimed at young drivers to promote behavioral changes.


Assuntos
Acidentes de Trânsito/mortalidade , Dirigir sob a Influência/estatística & dados numéricos , Etanol/sangue , Drogas Ilícitas/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Brasil/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Adulto Jovem
5.
J Anal Toxicol ; 38(6): 341-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24782143

RESUMO

A gas chromatography-mass spectrometric (GC-MS) method was developed and validated for the simultaneous detection and quantification in postmortem whole blood samples of cocaine (COC), amphetamines (AMPs) and cannabis; the main drugs involved in cases of impaired driving in Brazil. The analytes were extracted by solid-phase extraction by means of Bond-Elute Certify cartridges, derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide at 80°C for 30 min and analyzed by GC-MS. Linearity ranged from 10 to 500 ng/mL, except for ecgonine methyl ester, for which linearity ranged from 10 to 100 ng/mL. Inter- and intra-day imprecision ranged from 2.8 to 18.4% and from 1.5 to 14.9%, respectively. Accuracy values lay between 86.9 and 104.4%. The limit of quantitation for all drugs was 10 ng/mL and recoveries were >74% for all analytes, except for cannabinoids, which showed poor recovery (∼30%). The developed method was applied to real samples collected from deceased victims due to traffic accidents. These samples were selected according to the results obtained in immunoassay screening on collected urine samples. Five samples were positive for the presence of COC and metabolites, four samples were positive for cannabinoids, six samples were positive for AMPs and two samples were drug negative. Some samples were positive for more than one class of drug. Results obtained from whole blood samples showed good agreement with urine screening. The developed method proved capable of quantifying all three classes of drugs of abuse proposed in this study, through a one-step extraction procedure.


Assuntos
Anfetaminas/sangue , Canabinoides/sangue , Cocaína/sangue , Extração em Fase Sólida , Detecção do Abuso de Substâncias/métodos , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Limite de Detecção , Mudanças Depois da Morte , Reprodutibilidade dos Testes , Detecção do Abuso de Substâncias/instrumentação
6.
J Anal Toxicol ; 38(1): 39-45, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24225634

RESUMO

A GC-MS method for simultaneous analysis of cocaine (COC), amphetamines (AMPs), opiates, cannabinoids and their metabolites in vitreous humor (VH) was developed and fully validated. VH samples were extracted using solid phase extraction and injected into the GC-MS, using a selected ion monitoring mode. Linearity ranged from 10 to 1000 ng/mL; the exception was anhydroecgonine methyl ester (AEME), for which linearity ranged from 10 to 750 ng/mL. Inter-assay imprecision lay from 1.2 to 10.0%, intra-assay imprecision was <10.4% for all the analytes and accuracy ranged from 95.6 to 104.0%. An limit of quantitation for all drugs was 10 ng/mL and recoveries ranged from 70.4 to 100.1% for basic and neutral compounds; the acid compounds had poor recovery--<40%. The validated method was applied to 10 VH samples taken from individuals whose blood had screened positive for drugs of abuse. All the individuals screened positive for COC in the blood (seven samples) also had positive results in VH; COC concentration ranged from 30.81 to 283.97 ng/mL (mean 186.98 ng/mL) and benzoylecgonine concentration ranged from 11.47 to 460.98 ng/mL (mean 133.91 ng/mL). It was also noticed that, in five cases, cocaethylene was detected. AEME was also quantified in one case. The use of AMP detected by blood analysis was confirmed in the VH of one individual (24.31 ng/mL). However, samples taken from three individuals whose blood tested positive for carboxy-tetrahydrocannabinol presented negative results. The results demonstrated that VH is a suitable alternative biological sample to determine COC, AMPs, opiates and their metabolites.


Assuntos
Anfetaminas/análise , Analgésicos Opioides/análise , Canabinoides/análise , Cocaína/análogos & derivados , Corpo Vítreo/química , Calibragem , Cocaína/análise , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Extração em Fase Sólida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...