Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
2.
JAMA Cardiol ; 8(12): 1131-1139, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37851434

RESUMO

Importance: Early detection of atrial fibrillation (AF) may help prevent adverse cardiovascular events such as stroke. Deep learning applied to electrocardiograms (ECGs) has been successfully used for early identification of several cardiovascular diseases. Objective: To determine whether deep learning models applied to outpatient ECGs in sinus rhythm can predict AF in a large and diverse patient population. Design, Setting, and Participants: This prognostic study was performed on ECGs acquired from January 1, 1987, to December 31, 2022, at 6 US Veterans Affairs (VA) hospital networks and 1 large non-VA academic medical center. Participants included all outpatients with 12-lead ECGs in sinus rhythm. Main Outcomes and Measures: A convolutional neural network using 12-lead ECGs from 2 US VA hospital networks was trained to predict the presence of AF within 31 days of sinus rhythm ECGs. The model was tested on ECGs held out from training at the 2 VA networks as well as 4 additional VA networks and 1 large non-VA academic medical center. Results: A total of 907 858 ECGs from patients across 6 VA sites were included in the analysis. These patients had a mean (SD) age of 62.4 (13.5) years, 6.4% were female, and 93.6% were male, with a mean (SD) CHA2DS2-VASc (congestive heart failure, hypertension, age, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age, sex category) score of 1.9 (1.6). A total of 0.2% were American Indian or Alaska Native, 2.7% were Asian, 10.7% were Black, 4.6% were Latinx, 0.7% were Native Hawaiian or Other Pacific Islander, 62.4% were White, 0.4% were of other race or ethnicity (which is not broken down into subcategories in the VA data set), and 18.4% were of unknown race or ethnicity. At the non-VA academic medical center (72 483 ECGs), the mean (SD) age was 59.5 (15.4) years and 52.5% were female, with a mean (SD) CHA2DS2-VASc score of 1.6 (1.4). A total of 0.1% were American Indian or Alaska Native, 7.9% were Asian, 9.4% were Black, 2.9% were Latinx, 0.03% were Native Hawaiian or Other Pacific Islander, 74.8% were White, 0.1% were of other race or ethnicity, and 4.7% were of unknown race or ethnicity. A deep learning model predicted the presence of AF within 31 days of a sinus rhythm ECG on held-out test ECGs at VA sites with an area under the receiver operating characteristic curve (AUROC) of 0.86 (95% CI, 0.85-0.86), accuracy of 0.78 (95% CI, 0.77-0.78), and F1 score of 0.30 (95% CI, 0.30-0.31). At the non-VA site, AUROC was 0.93 (95% CI, 0.93-0.94); accuracy, 0.87 (95% CI, 0.86-0.88); and F1 score, 0.46 (95% CI, 0.44-0.48). The model was well calibrated, with a Brier score of 0.02 across all sites. Among individuals deemed high risk by deep learning, the number needed to screen to detect a positive case of AF was 2.47 individuals for a testing sensitivity of 25% and 11.48 for 75%. Model performance was similar in patients who were Black, female, or younger than 65 years or who had CHA2DS2-VASc scores of 2 or greater. Conclusions and Relevance: Deep learning of outpatient sinus rhythm ECGs predicted AF within 31 days in populations with diverse demographics and comorbidities. Similar models could be used in future AF screening efforts to reduce adverse complications associated with this disease.


Assuntos
Fibrilação Atrial , Aprendizado Profundo , Acidente Vascular Cerebral , Veteranos , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Eletrocardiografia
4.
JACC Clin Electrophysiol ; 9(2): 219-228, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36858688

RESUMO

BACKGROUND: The difference between the right ventricular (RV) apical stimulus-atrial electrogram (SA) interval during resetting of supraventricular tachycardia (SVT) versus the ventriculoatrial (VA) interval during SVT (ΔSA-VAapex) is an established technique for discerning SVT mechanisms but is limited by a significant diagnostic overlap. OBJECTIVES: This study hypothesized that the difference between the RV SA interval during resetting of SVTs versus the VA interval during SVTs (ΔSA-VA) would yield a more robust differentiation of atrioventricular nodal re-entrant tachycardia (AVNRT) from atrioventricular reciprocating tachycardia (AVRT) when using the RV basal septal stimulation (ΔSA-VAbase) as compared to the RV apical stimulation (ΔSA-VAapex). Moreover, it was predicted that the ΔSA-VAbase might distinguish septal from free wall accessory pathways (APs) effectively. METHODS: In this prospective study, 105 patients with AVNRTs (age 48 ± 20 years, 44% male) and 130 with AVRTs (age 26 ± 18 years, 54% male) underwent programmed ventricular extrastimuli delivered from both the RV basal septum and RV apex. The ΔSA-VA values were compared between the 2 sites. RESULTS: The ΔSA-VAbase was shorter than the ΔSA-VAapex during AVRT (44 ± 30 ms vs 58 ± 29 ms; P < 0.001), and the opposite occurred during AVNRT (133 ± 31 ms vs 125 ± 25 ms; P = 0.03). A ΔSA-VAbase of ≧85 milliseconds had a sensitivity of 97% and specificity of 96% for identifying AVNRT. Furthermore, a ΔSA-VAbase of 45-85 milliseconds identified AVRT with left free wall APs (sensitivity 86%, specificity 95%), 20-45 milliseconds for posterior septal APs (sensitivity 72%, specificity 96%), and <20 milliseconds for right free wall or anterior/mid septal APs (sensitivity 86%, specificity 98%). CONCLUSIONS: The ΔSA-VAbase during programmed ventricular extrastimuli produced a robust differentiation between AVNRT and AVRT regardless of the AP location with ≧85 milliseconds as an excellent cutoff point. This straightforward technique further allowed localizing 4 general AP sites.


Assuntos
Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Septo Interventricular , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Criança , Adolescente , Adulto Jovem , Feminino , Estudos Prospectivos , Ventrículos do Coração
5.
J Interv Card Electrophysiol ; 66(7): 1679-1691, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36737506

RESUMO

BACKGROUND: Implantable cardioverter defibrillators (ICDs) are typically programed with both ventricular tachycardia (VT) and ventricular fibrillation (VF) treatment zones. Biotronik and Abbott ICDs do not increment the VT counter when the tachycardia accelerates to the VF zone, which could result in a prolonged delay in tachycardia detection. METHODS: Patients with Biotronik and Abbott ICDs receiving care at Veterans Affairs facilities in Northern California were identified. Patient information and device tracings for patients with any ICD therapies were examined to assess for possible delayed tachycardia detection. RESULTS: Among 52 patients with Biotronik ICDs, 8 (15%) experienced appropriate ICD therapy over a median follow-up of 29 months. Among 68 patients with Abbott ICDs, 26 (38%) experienced appropriate ICD therapy over a median follow-up of 83 months. Three of the patients with Biotronik ICDs who received appropriate therapy experienced a delay in VT/VF detection due to the tachycardia rate oscillating between the VT and VF treatment zones (longest 31.2 s on detection), compared with four of the patients with Abbott ICDs (longest 4.1 s on the detection and 8 s on redetect). One of the patients with a Biotronik ICD experienced recurrent syncope associated with delayed detection and another died on the day of delayed detection. One of the patients with an Abbott ICD experienced syncope. CONCLUSIONS: Because contemporary Biotronik and Abbott ICDs freeze the VT counters when tachycardia is in the VF zone, ICD therapies can be markedly delayed when the tachycardia oscillates between the VT and VF zone.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Desfibriladores Implantáveis/efeitos adversos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia , Fibrilação Ventricular/etiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiologia , Cardioversão Elétrica/efeitos adversos , Síncope/etiologia
7.
Heart ; 109(8): 606-611, 2023 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-36549682

RESUMO

OBJECTIVE: Obesity and dysmetabolism are major risk factors for atrial fibrillation (AF). Fasting and postload levels of glucose and non-esterified fatty acids (NEFAs) reflect different facets of metabolic regulation. We sought to study their respective contributions to AF risk concurrently. METHODS: We assessed levels of fasting and postload glucose and NEFA in the Cardiovascular Health Study to identify associations with AF incidence and, secondarily, with ECG parameters of AF risk available at baseline. Linear and Cox regressions were performed. RESULTS: The study included 1876 participants (age 77.7±4.4). During the median follow-up of 11.4 years, 717 cases of incident AF occurred. After adjustment for potential confounders, postload glucose showed an association with incident AF (HR per SD increment of postload glucose=1.11, 95% CI 1.02 to 1.21, p=0.017). Both glucose measures, but not NEFA, were positively associated with higher P wave terminal force in V1 (PTFV1); the association remained significant only for postload glucose when the two measures were entered together (ß per SD increment=138 µV·ms, 95% CI 15 to 260, p=0.028). Exploratory analyses showed significant interaction by sex for fasting NEFA (pinteraction=0.044) and postload glucose (pinteraction=0.015) relative to AF, with relationships stronger in women. For postload glucose, the association with incident AF was observed among women but not among men. CONCLUSIONS: Among older adults, postload glucose was positively associated with incident AF, with consistent findings for PTFV1. In exploratory analyses, the relationship with AF appeared specific to women. These findings require further study but suggest that interventions to address postprandial dysglycaemia late in life might reduce AF.


Assuntos
Fibrilação Atrial , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Metabolismo dos Lipídeos , Seguimentos , Estudos Prospectivos , Eletrocardiografia , Fatores de Risco , Glucose , Incidência
8.
J Gerontol A Biol Sci Med Sci ; 78(7): 1164-1171, 2023 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-36373954

RESUMO

BACKGROUND: Glucose and non-esterified fatty acids (NEFA) are myocardial fuels whose fasting and post-prandial levels are under different homeostatic regulation. The relationships of fasting and post-load glucose and NEFA with incident heart failure (HF) remain incompletely defined. METHODS: Serum glucose and NEFA were measured during fasting and 2 hours post-oral glucose tolerance test, performed in Cardiovascular Health Study participants not receiving hypoglycemic medication. Participants with prevalent HF or lacking relevant data were excluded. Outcomes were incident HF (primary), and HF with preserved (HFpEF) and reduced (HFrEF) ejection fraction (secondary). RESULTS: Among 2 238 participants (age 78 ± 4) with a median follow-up of 9.9 years, there were 737 HF events. After adjustment for demographic and lifestyle factors, both fasting (hazard ratio [HR] = 1.11 per SD [95% confidence interval {CI} = 1.01-1.23], p = .040) and post-load (HR = 1.14 per SD [1.05-1.24], p = 0.002) glucose were significantly associated with incident HF. No association was seen for fasting or post-load NEFA. Upon mutual adjustment, only post-load glucose (HR = 1.11 [1.003-1.22], p = .044), but not fasting glucose (HR = 1.06 [0.94-1.20], p = .340), remained associated with HF. Further adjustment for cardiovascular disease and other risk factors in the causal pathway did not affect the association for post-load glucose, but eliminated that for fasting glucose. Associations for fasting and post-load glucose appeared stronger with higher adiposity and were observed specifically for HFrEF but not HFpEF. CONCLUSIONS: Fasting and post-load glucose, but not NEFA, were associated with incident HF. The association was especially robust for post-load glucose, suggesting that pathways involved in post-prandial dysglycemia could offer new targets for HF prevention late in life.


Assuntos
Glucose , Insuficiência Cardíaca , Humanos , Idoso , Idoso de 80 Anos ou mais , Insuficiência Cardíaca/epidemiologia , Volume Sistólico/fisiologia , Fatores de Risco , Ácidos Graxos , Prognóstico
9.
Heart Rhythm ; 19(5): 807-811, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35501106

RESUMO

BACKGROUND: Cardiac electrophysiology (EP) has few women physicians. OBJECTIVE: The purpose of this study was to determine temporal and geographical trends in the proportion of women EP operators in the United States. METHODS: We extracted data from the Medicare Provider Utilization and Payment Database from 2013 to 2019 using procedure codes for atrial fibrillation (AF) ablation, supraventricular tachycardia/atrial flutter (SVT/AFL) ablation, and cardiac device implantation. The Medicare Provider Utilization and Payment Database excludes operators who perform ≤10 procedures annually for a given individual procedure code. The proportion of women operators was compared across the 7-year period. RESULTS: On average annually between 2013 and 2019, 5% (n = 187) of the 3524 EP operators were women. Procedure-specific analyses demonstrated a similarly low proportion of women EP operators across each procedure type. Despite a 137% increase in the total number of AF ablationists over the 7-year period, the proportion of women remained unchanged (P = .3966). The number of SVT/AFL ablationists and device operators remained constant over time as did the proportion of women operators (P = .9709 and .3583, respectively). In 2019, 10 states (20%) had no women EP operators who performed >10 of any given EP procedure annually, 20 states (39%) had no women who performed >10 of either AF or SVT/AFL ablation procedures annually, and 10 states (20%) had no women device operators who performed >10 of any given type of device implantation annually. CONCLUSION: Women EP operators remain underrepresented, and the proportion of women is stagnant even in areas of major clinical growth such as AF ablation. One-fifth of states had no women operators who performed >10 of any given EP procedure annually.


Assuntos
Fibrilação Atrial , Flutter Atrial , Taquicardia Paroxística , Taquicardia Supraventricular , Idoso , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Flutter Atrial/epidemiologia , Flutter Atrial/cirurgia , Eletrofisiologia Cardíaca , Feminino , Humanos , Masculino , Medicare , Taquicardia Supraventricular/cirurgia , Estados Unidos/epidemiologia
10.
J Cardiopulm Rehabil Prev ; 42(4): 258-265, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35235540

RESUMO

PURPOSE: Atrial fibrillation (AF) is associated with the comorbidities of a sedentary lifestyle. Endurance athletes also show an increased incidence of AF. The role of exercise in the treatment of AF is unknown so this study aimed to examine the effects of supervised exercise on AF. METHODS: A meta-analysis of randomized controlled trials (RCTs) examining supervised exercise training in participants with AF was performed. The primary outcome was AF recurrence and burden. Secondary outcomes included AF symptoms, quality of life, and cardiorespiratory fitness (CRF). RESULTS: Thirteen RCTs, involving 1155 participants, were included. Paroxysmal AF was present in 34% and persistent AF in 64%. The types of exercise were diverse and included cardiac rehabilitation (64%), aerobic training (7%), Qi Gong (4%), interval training (11%), and yoga (15%). Exercise training reduced AF recurrence (relative risk = 0.77: 95% CI, 0.60-0.99), improved quality of life in 5 of the 10 components of the Short Form 36 survey, and improved CRF (standardized mean difference [SMD] = 0.56: 95% CI, 0.27-0.85). The AF burden was reduced only in studies that included continuous ambulatory monitoring (SMD =-0.49: 95% CI, -0.96 to -0.01) but not when all studies were included (SMD =-0.12: 95% CI, -0.61 to 0.38). There was no difference in adverse events between exercise and control. CONCLUSIONS: Supervised exercise training is safe, reduces AF recurrence, and improves quality of life and CRF in participants with AF. Further large RCTs with ambulatory monitoring and robust exercise regimens are needed to assess the effects of exercise training on AF burden and AF symptoms.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/reabilitação , Exercício Físico , Tolerância ao Exercício , Humanos , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Comportamento Sedentário
11.
JACC Case Rep ; 3(4): 610-613, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34317587

RESUMO

Catheter entrapment is a rare complication during catheter ablation that may require surgical intervention. Use of adenosine to prolong diastole can be a safe and effective strategy to free the catheter and avoid significant morbidity. (Level of Difficulty: Advanced.).

12.
Heart ; 107(22): 1805-1812, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33483356

RESUMO

OBJECTIVE: Obesity and dysmetabolism are major risk factors for atrial fibrillation (AF). Expansion of fat depots is associated with increased circulating total non-esterified fatty acids (NEFAs), elevated levels of which are associated with incident AF. We undertook comprehensive serum measurement of individual NEFA to identify specific associations with new-onset AF late in life. METHODS: The present study focused on participants with available serum and free of AF selected from the Cardiovascular Health Study, a community-based longitudinal investigation of older US adults. Thirty-five individual NEFAs were measured by gas chromatography. Cox regression was used to evaluate the association of individual NEFAs with incident AF. RESULTS: The study sample included 1872 participants (age 77.7±4.4). During median follow-up of 11.3 years, 715 cases of incident AF occurred. After concurrent adjustment of all NEFAs and full adjustment for potential confounders, higher serum concentration of nervonic acid (24:1 n-9), a long-chain monounsaturated fatty acid, was associated with higher risk of AF (HR per SD: 1.18, 95% CI 1.08 to 1.29; p<0.001). Conversely, higher serum concentration of gamma-linolenic acid (GLA) (18:3 n-6), a polyunsaturated n-6 fatty acid, was associated with lower risk of AF (HR per SD: 0.81, 95% CI 0.71 to 0.94; p=0.004). None of the remaining NEFAs was significantly associated with AF. CONCLUSIONS: Among older adults, serum levels of non-esterified nervonic acid were positively associated, while serum levels of non-esterified GLA were inversely associated, with incident AF. If confirmed, these results could offer new strategies for AF prevention and early intervention in this segment of the population at highest risk.


Assuntos
Fibrilação Atrial/epidemiologia , Ácidos Graxos não Esterificados/sangue , Medição de Risco/métodos , Idoso , Fibrilação Atrial/sangue , Biomarcadores/sangue , Feminino , Seguimentos , Humanos , Incidência , Masculino , Estudos Prospectivos , Fatores de Risco , Estados Unidos/epidemiologia
13.
Europace ; 21(11): 1703-1709, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31545350

RESUMO

AIMS: Rotating sheaths and laser sheaths are commonly used for transvenous lead extraction. This study aims to compare observed mortality between both approaches. METHODS AND RESULTS: The Manufacturer and User Facility Device Experience database was searched from 2011 to 2016 to determine number of deaths associated with each sheath. An independent analytics firm provided estimates for number of cases done, allowing calculation of market share. A sensitivity analysis was performed to determine relative risk (RR) of mortality at the calculated market share (36% rotating/64% laser) and two others. Additional sensitivity analyses assumed underreporting of deaths associated with rotating sheaths. An estimated 50 545 extractions were performed. Thirteen deaths were associated with rotating sheaths compared to 167 with laser sheaths. Of these, 92% (rotating) and 95% (laser) were due to cardiovascular injury. At the calculated market share, the RR of death was 7.2 times greater with laser sheaths [95% confidence interval (CI) 4.1-12.7, P < 0.0001]. At market share estimates of 25% rotating/75% laser and 45% rotating/55% laser, the RR of death with laser sheaths was 4.3 (95% CI 2.4-7.5, P < 0.0001) and 10.5 times greater (95% CI 6.0-18.5, P < 0.0001), respectively. The RR of death remained significant when assuming deaths with rotating sheaths were underreported and when deaths using both sheaths were attributed to the rotating sheath. CONCLUSIONS: Lead extraction with laser sheaths appears to be associated with a higher risk of mortality compared to rotating sheaths. Further studies are warranted to confirm this finding.


Assuntos
Arritmias Cardíacas/terapia , Remoção de Dispositivo/mortalidade , Eletrodos Implantados , Arritmias Cardíacas/mortalidade , Remoção de Dispositivo/métodos , Desenho de Equipamento , Seguimentos , Humanos , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
16.
Heart Rhythm ; 16(9): e227-e279, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30412777
17.
Heart Rhythm ; 16(9): e128-e226, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30412778
20.
JACC Clin Electrophysiol ; 4(7): 872-880, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-30025686

RESUMO

OBJECTIVES: This study hypothesized that early coupled ventricular extrastimuli (V2) stimulation might yield a more robust differentiation between atrioventricular nodal re-entrant tachycardia (AVNRT) and atrioventricular re-entrant tachycardia (AVRT). BACKGROUND: Programmed V2 during supraventricular tachycardia are useful to differentiate AVNRT from AVRT by subtracting the ventriculoatrial (VA) interval from the stimulus to atrial depolarization (stimulus atrial [SA]) interval, but all such maneuvers have limitations. METHODS: Patients with either AVNRT or AVRT were investigated. The entire tachycardia cycle length (TCL) was scanned with V2 delivered from the right ventricular apex. The SA-VA difference was calculated with V2 clearly resetting the tachycardia. The prematurity of V2 was calculated by dividing the coupling interval (CI) by the TCL. RESULTS: A total of 210 patients (102 with AVNRT) were included. The SA-VA difference was >70 ms in all AVNRT patients and was <70 ms in all AVRT patients with right and septal accessory pathways (APs), except for those with decremental APs, in whom there was an overlap between AVNRT and AVRT with left APs. However, a SA-VA difference >110 ms with a CI/TCL of <65% distinguished AVNRT from AVRT using the left AP, with sensitivity and specificity of 87% and 100%, respectively. Ventricular overdrive pacing resulted in tachycardia termination or AV dissociation in 28% of patients compared with 15% of patients using the V2 technique (p = 0.008). CONCLUSIONS: A SA-VA of >70 ms using the V2 technique differentiated AVNRT from AVRT using septal and right APs. Use of the V2 technique with a short CI differentiated AVNRT from AVRT using left APs. The V2 technique less frequently resulted in tachycardia termination compared with ventricular entrainment.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Adolescente , Adulto , Idoso , Criança , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/classificação , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia Supraventricular/classificação , Taquicardia Supraventricular/diagnóstico , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...