Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 100(4): 620-627, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35842775

RESUMO

OBJECTIVES: To assess feasibility and safety of second-generation left atrial appendage closure (LAAC) Ultraseal device in patients with nonvalvular atrial fibrillation (NVAF). BACKGROUND: LAAC with first-generation Ultraseal device (Cardia, Eagan, Minnesota) has been shown to be a feasible therapeutic option in patients with NVAF. However, there is a paucity of data regarding the novel second-generation Ultraseal device. METHODS: All patients with NVAF undergoing second-generation Ultraseal device implantation between February 2018 and September 2020 were included in a multicenter international registry. Periprocedural and post-discharge events were collected through 6-month follow-up. Co-primary efficacy endpoints were device success and technical success while primary safety endpoint was in-hospital major adverse event (MAE) occurrence. RESULTS: A total of 52 patients were included: mean age 75 ± 8, 30.8% women, mean HAS-BLED 3 ± 1. The device was successfully implanted in all patients. Technical success was achieved in 50 patients (96.1%). In-hospital MAEs occurred in three patients (5.8%). The incidence of 6-month all-cause death and major bleeding was 11.6% and 2.1%, respectively. No strokes, transient ischemic attacks, systemic embolisms, or device embolization were reported after discharge. CONCLUSIONS: Second-generation Ultraseal device implantation was associated with high success rates and a low incidence of peri-procedural complications. Larger studies with longer follow-up are warranted to further evaluate the safety and the efficacy of this device, especially at long-term follow-up.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Assistência ao Convalescente , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Feminino , Humanos , Masculino , Alta do Paciente , Sistema de Registros , Resultado do Tratamento
2.
Diagnostics (Basel) ; 12(2)2022 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-35204518

RESUMO

Ultrasound (US)-based measurements of the inferior vena cava (IVC) diameter are widely used to estimate right atrial pressure (RAP) in a variety of clinical settings. However, the correlation with invasively measured RAP along with the reproducibility of US-based IVC measurements is modest at best. In the present manuscript, we discuss the limitations of the current technique to estimate RAP through IVC US assessment and present a new promising tool developed by our research group, the automated IVC edge-to-edge tracking system, which has the potential to improve RAP assessment by transforming the current categorical classification (low, normal, high RAP) in a continuous and precise RAP estimation technique. Finally, we critically evaluate all the clinical settings in which this new tool could improve current practice.

3.
G Ital Nefrol ; 37(1)2020 Feb 12.
Artigo em Italiano | MEDLINE | ID: mdl-32068363

RESUMO

Atrial fibrillation is the most common cardiac disorder among chronic nephropathic patients. Possible therapeutic approaches include the use of anticoagulants, which are able to reduce the risk of thromboembolism but lead to an increasing bleeding risk, especially in this cohort of patients. Also, novel oral anticoagulant agents (NAO), due to their mainly renal clearance, are a relative contraindication in advanced renal disease. As an alternative to the oral anticoagulant therapy, left atrial appendage occlusion seems a promising opportunity in high risk, difficult to manage patients. Since there is limited evidence of LAAO in advanced chronic renal disease or dialysis patients, we report here a monocenter experience on 12 patients (6 of which in regular dialytic treatment) with a median clinical follow-up of fourteen months (3-22 months).


Assuntos
Apêndice Atrial , Fibrilação Atrial/complicações , Insuficiência Renal Crônica/complicações , Oclusão Terapêutica/instrumentação , Tromboembolia/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Contraindicações de Medicamentos , Inibidores do Fator Xa/uso terapêutico , Hemorragia/induzido quimicamente , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Diálise Renal , Insuficiência Renal Crônica/terapia , Medição de Risco , Tromboembolia/etiologia
4.
J Interv Cardiol ; 24(5): 477-84, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21539612

RESUMO

BACKGROUND: Transcatheter closure of patent foramen ovale (PFO) is a widespread procedure, but no randomized study on its outcome in high-risk patients is available. Our aims were to determine the efficacy and safety of this procedure in a cohort of high-risk patients through the observation of clinical adverse events and residual shunt, to evaluate the impact of transesophageal echocardiography (TEE) guidance during the procedure, and investigate the relationship between the anatomical and clinical characteristics and the outcome. METHODS AND RESULTS: Ninety-five patients underwent PFO closure for cryptogenic cerebral ischemia; each of them presented one or more of the following risk factors: recurrent cerebral ischemia (9.5%), atrial septum aneurysm (ASA, 74.5%), prominent Eustachian valve (EV, 23.2%), severe basal shunt (9.5%), thrombophilic factors (20%), deep vein thrombosis (4.2%). The procedure was performed successfully in all patients. On median follow-up of 18 months, the neurologic recurrent events rate was 1.1% and the major adverse cardiac event (MACE) rate was 1.1%. At 6-month TEE follow-up, the residual shunt rate was 12.6% (3.1% moderate to severe). A significant correlation was found between residual shunt and prominent EV alone (P = 0.036) or in association with ASA (P = 0.021). All adverse events occurred in the first 8 months, and the event-free survival rate was 86.2%. CONCLUSIONS: Our study suggests that transcatheter PFO closure is a safe procedure even in a selected population of high-risk patients, presenting satisfactory efficacy and safety. The presence of a prominent EV alone or with ASA correlates positively with the occurrence of residual shunt.


Assuntos
Isquemia Encefálica/terapia , Ablação por Cateter/métodos , Forame Oval Patente/terapia , Adulto , Idoso , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/mortalidade , Ablação por Cateter/instrumentação , Estudos de Coortes , Ecocardiografia Transesofagiana , Feminino , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/mortalidade , Comunicação Interatrial/terapia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Medição de Risco , Estatística como Assunto , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...