Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int Immunopharmacol ; 132: 111905, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38552291

RESUMO

INTRODUCTION: IgA nephropathy (IgAN) is the most prevalent form of glomerulonephritis. Unfortunately, molecular biomarkers for IgAN derived from omics studies are still lacking. This research aims to identify critical genes associated with IgAN through large-scale blood transcriptome analysis. METHODS: We constructed novel blood transcriptome profiles from peripheral blood mononuclear cells (PBMCs) of 53 Chinese IgAN patients and 28 healthy individuals. Our analysis included GO, KEGG, and GSEA for biological pathways. We analyzed immune cell profiles with CIBERSORT and constructed PPI networks with STRING, visualized in Cytoscape. Key differentially expressed genes (DEGs) were identified using CytoHubba and MCODE. We assessed the correlation between gene expressions and clinical data to evaluate clinical significance and identified hub genes through machine learning, validated with an open-access dataset. Potential drugs were explored using the CMap database. RESULTS: We identified 333 DEGs between IgAN patients and healthy controls, mainly related to immune response and inflammation. Key pathways included NK cell mediated cytotoxicity, complement and coagulation cascades, antigen processing, and B cell receptor signaling. Cytoscape revealed 16 clinically significant genes (including KIR2DL1, KIR2DL3, VISIG4, C1QB, and C1QC, associated with sub-phenotype and prognosis). Machine learning identified two hub genes (KLRC1 and C1QB) for a diagnostic model of IgAN with 0.92 accuracy, validated at 1.00 against the GSE125818 dataset. Sirolimus, calcifediol, and efaproxiral were suggested as potential therapeutic agents. CONCLUSION: Key DEGs, particularly VISIG4, KLRC1, and C1QB, emerge as potential specific markers for IgAN, paving the way for future targeted personalized treatment options.


Assuntos
Biomarcadores , Perfilação da Expressão Gênica , Glomerulonefrite por IGA , Transcriptoma , Humanos , Glomerulonefrite por IGA/genética , Glomerulonefrite por IGA/sangue , Glomerulonefrite por IGA/tratamento farmacológico , Glomerulonefrite por IGA/imunologia , Biomarcadores/sangue , Masculino , Feminino , Adulto , Mapas de Interação de Proteínas , Leucócitos Mononucleares/metabolismo , Leucócitos Mononucleares/imunologia , Aprendizado de Máquina , Redes Reguladoras de Genes , Pessoa de Meia-Idade
2.
Eur J Med Chem ; 259: 115696, 2023 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-37542990

RESUMO

Glycyrrhizin (GL) is one of the antagonists of highly conserved nuclear protein (HMGB1). The researches have shown that the glycosyl of GL is an important pharmacophore for GL binding to HMGB1, and it is the determinant factor for mechanism of action. To get the HMGB1 inhibitors with higher activity and good pharmacokinetic properties, two classes of GL analogues containing C-N glycoside bond were synthesized, and their anti-inflammatory, anti-oxidative stress and anti-septic kidney injury were evaluated. The results are as follows. First, in the anti-inflammatory assay, all the compounds inhibited NO release in some degree; among them, compound 6 displayed the strongest NO inhibitory effect with IC50 value of 15.9 µM, and compound 15 with IC50 of 20.2 µM. The two compounds not only decreased IL-1ß and TNF-α levels in RAW264.7 cells and HK-2 cells, but also downregulated the levels of NLRP3, P-NF-κB p65 and HMGB1 in activated HK-2 cells in a dose-dependent manner. Second, in the renal protection assay with H2O2-stimulated HK-2 cell line, they reduced MDA level and increased SOD in HK-2 cells; additionally, they also inhibited the HK-2 cell apoptosis and downregulated the Caspase-1 p20 level. Third, in the in vivo activity tests of the septic mouse, they also showed good activities just like in vitro, decreasing the IL-1ß, TNF-α, MDA, blood creatinine (Scr) and urea nitrogen (BUN) in serum, and increasing SOD levels in a dose-dependent manner. The immunoblotting results showed the two compounds downregulated the levels of HMGB1, P-NF-κB p65, NLRP3 and Caspase-1 p20 protein. All in all, the two compounds improved the renal injury of septic mice, and alleviated the tube wall structure damage and renal tubular dilation in kidney, which further proved by H&E staining. This suggests the two compounds have septic acute kidney injury activity, and they will be potential therapeutic drugs for septic acute kidney injury.


Assuntos
Injúria Renal Aguda , Proteína HMGB1 , Sepse , Camundongos , Animais , Ácido Glicirrízico/farmacologia , Ácido Glicirrízico/uso terapêutico , NF-kappa B/metabolismo , Proteína HMGB1/metabolismo , Proteína HMGB1/uso terapêutico , Fator de Necrose Tumoral alfa/metabolismo , Proteína 3 que Contém Domínio de Pirina da Família NLR , Peróxido de Hidrogênio , Injúria Renal Aguda/tratamento farmacológico , Injúria Renal Aguda/metabolismo , Anti-Inflamatórios/farmacologia , Anti-Inflamatórios/uso terapêutico , Sepse/tratamento farmacológico , Sepse/metabolismo , Caspases , Superóxido Dismutase
3.
Bioorg Chem ; 138: 106609, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37207595

RESUMO

Cardiac tissue suffers much from sepsis, and the incidence of myocardial injury is high in septic patients. The treatment of sepsis myocardial injury (SMI) has been the focus of clinical medicine. Salidroside shows myocardial cell protection, anti-oxidation and anti- inflammation effects, and it is thought as one of the potential compounds to treat sepsis myocardial injury. However, its anti-inflammatory activity is lower and its pharmacokinetic properties are not ideal, which is far from clinical application. Here, a series of salidroside analogs were synthesized, and their bioactivities were evaluated from several aspects, including their anti-oxidant and anti-inflammatory activities in vitro and anti-sepsis myocardial injury activities in vivo. Of all the compounds which synthesized, compounds 2 and 3 exhibited stronger anti-inflammatory activities than the others; after treating LPS-stimulated RAW264.7 or H9c2 cells with each of them, the levels of IL-1ß, IL-6 and TNF-α were down-regulated in a dose-dependent manner. In the anti-oxidative stress injury test, compounds 2 and 3 not only markedly increased the survival rate of cells, and but also improved the cellular oxidative stress-related indicators MDA, SOD and cell damage marker LDH in a dose-dependent manner. In the LPS-induced septic rat myocardial injury models (in vivo), the two compounds also showed good bioactivities. They also reduced the expression of IL-1ß, IL-6 and TNF-α, and blocked cell damage by suppressing overhauled oxidation in septic rats. In addition, the myocardial injury was significantly improved and the inflammatory infiltration was reduced after treatment with the two compounds. In conclusion, the salidroside analogs (2 and 3) showed promising therapeutical effect on septic myocardial injury in LPS-model rats, and they could be good candidates for clinical trials against inflammation and septic myocardial injury.


Assuntos
Sepse , Fator de Necrose Tumoral alfa , Ratos , Animais , Fator de Necrose Tumoral alfa/metabolismo , Interleucina-6/metabolismo , Lipopolissacarídeos/farmacologia , Anti-Inflamatórios/farmacologia , Sepse/tratamento farmacológico , Inflamação
4.
RSC Med Chem ; 13(11): 1391-1409, 2022 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-36439975

RESUMO

Bile acids (BAs) containing both hydrophilic hydroxyl and carboxyl groups and hydrophobic methyl and steroid nuclei can promote the absorption of fat and other substances in the intestine, and they are synthesized by cholesterol in the liver and then returned to the liver through enteric liver circulation. Because there are many BA receptors on the cell membrane of colon tissues, BAs can improve the specific delivery and transport of medicines to colon tissues. Moreover, BAs have a certain anticancer and inflammation activity by themselves. Based on this theory, a series of BA derivatives against colon cancer including cholic acid (CA), chenodeoxycholic acid (CDCA), ursodeoxycholic acid (UDCA) and lithocholic acid (LCA) were designed and synthesized, and their antitumor activity was evaluated. For in vitro anti-tumor tests, all the compounds displayed cell proliferative inhibition to nine human malignant tumor cell lines to some degree, and in particular they showed stronger inhibition to the colon cancer cells than the other cell lines. Among them, four compounds (4, 5, 6, and 7) showed stronger activity than the other compounds as well as the positive control 5-FU against HCT116 cells, and their IC50 was between 21.32 µmol L-1 and 28.90 µmol L-1; cell clone formation and migration tests showed that they not only effectively inhibited the formation of HCT116 cell colonies, but also inhibited the HCT116 cell migration and invasion; moreover, they induced apoptosis, arrested the mitotic process at the G2/M phase of the cell cycle, reduced the mitochondrial membrane potential, increased the intracellular ROS levels, and reduced the expression of Bcl-2 and p-STAT3 in HCT 116 cells. In addition, they also displayed intermediate anti-inflammatory activity by inhibiting inflammatory mediators NO and downregulating TNF-α expression, which also is one of the causes of colon cancer. This suggests that they deserve to be further investigated as candidates for colon cancer treatment drugs.

5.
BMC Ophthalmol ; 22(1): 348, 2022 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-35982400

RESUMO

BACKGROUND: To identify the predictive parameter among preoperative measurements that best predicts postoperative visual outcome in the epiretinal membrane (ERM). METHODS: Thirty-three consecutive patients with idiopathic unilateral ERM patients between 2015 and 2018 were enrolled. Nineteen healthy normal eyes were selected as an independent age-matched group. Based on preoperative optical coherence tomography (OCT), we further divided the patients with ERM into two groups: type 1, loosely attached ERM, and type 2, tight adherent ERM. We documented the vision and thickness of various retinal layers: nerve fiber layer, ganglion cell layer, inner plexiform layer (GCL + IPL), inner nuclear layer (INL), outer retinal layer (ORL), and retinal pigment epithelium/Bruch complex layer before and after the surgery. The association between postoperative visual acuity and these variables was analyzed using multiple linear regression analysis. RESULTS: All retinal layers of ERM eyes were thicker than the normal eyes (P < 0.05). Among ERMs, we identified 11 eyes with type 1 adhesions and 22 eyes with type 2 adhesions. The preoperative GCL + IPL layers were significantly thicker in type 2 patients than in type 1 patients (93.67 ± 33.03 um vs 167.71 ± 13.77 um; P = 0.023). Greater GCL + IPL thickness was correlated with a worse postoperative visual acuity and multiple linear regression analysis showed that GCL + IPL thickness was an independent predictor of postoperative visual acuity (VA) (beta value = 0.689; P = 0.012). A greater thickness of GCL + IPL layers of type 2 patients had worse postoperative best-corrected visual acuity (BCVA) (P = 0.028). Ectopic inner foveal layers with disappearance of fovea pit were persistently presented in OCT profiles of both groups. CONCLUSION: Idiopathic ERM demonstrated significantly thicker inner retinal layers (GCL + IPL and INL). However, the ORL thickness was similar between the normal eyes and ERM eyes. The preoperative GCL + IPL layers were significantly thicker in patients with type 2 ERM than that in patients with type 1 ERM. The increase in GCL + IPL thickness was significantly correlated with worse postoperative visual outcomes.


Assuntos
Membrana Epirretiniana , Membrana Epirretiniana/diagnóstico , Membrana Epirretiniana/cirurgia , Fóvea Central , Humanos , Retina , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Transtornos da Visão , Acuidade Visual
6.
Fundam Res ; 2(3): 487-495, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-38933401

RESUMO

In this study, we consider the problem of node ranking in a random network. A Markov chain is defined for the network, and its transition probability matrix is unknown but can be learned by sampling random interactions among nodes. Our objective is to decompose the Markov chain into several ergodic classes and select the best node in each ergodic class. We propose a dynamic sampling procedure, which gives a probability guarantee on correct decomposition and maximizes a weighted probability of correct selection of the best node in each ergodic class. Numerical experiment results demonstrate the efficiency of the proposed sampling procedure.

7.
Sci Total Environ ; 794: 148801, 2021 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-34323744

RESUMO

Lake sediments are the products of soil erosion and are strongly influenced by climate variability, particularly extreme meteorological events. Sediment organic carbon (SOC) can reflect environmental changes that affect sediment transport. However, the response of SOC chronological records to major meteorological events is relatively unknown. This study explored the chronological regularity of SOC and verified its variations using major historical meteorological events. Based on three sediment profiles with a depth of 230 cm at the Yuan River entrance to the West Dongting Lake (Hanshou entrance), the SOC chronology was reconstructed by employing the sedimentation rates calculated by 137Cs and 210Pb. The sedimentary environment then was interpreted via comparisons and quantitative analysis. The grain distribution and the S-shaped distribution of SOC reflected the general deposition regularity of organic carbon in lake sediments, which gradually stabilized with depth. The average sedimentation rates based on 137Cs and 210Pb were 1.310 and 1.319 cm a-1, respectively. Accordingly, SOC records covered the past 76 years via dating (0-100 cm), during which the SOC content first increased and subsequently stabilized. By comparing the data with the occurrence of 11 major historical meteorological events, we found that SOC generally increased after these events. Moreover, the frequent occurrence of meteorological events stabilized the SOC content. Severe floods had a greater impact on SOC content than severe droughts, causing SOC to change by up to 20.24% and 8.77%, respectively. Our findings suggest that major historical meteorological events can verify SOC chronological records, thereby highlighting their significant impacts on organic carbon variations in sediments.


Assuntos
Lagos , Poluentes Radioativos da Água , Carbono/análise , Monitoramento Ambiental , Sedimentos Geológicos , Poluentes Radioativos da Água/análise
8.
Int Ophthalmol ; 39(7): 1511-1522, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29926364

RESUMO

PURPOSE: To evaluate the visual and anatomical outcomes of intravitreal ranibizumab for diabetic macular edema (DME) in the healthcare system of Taiwan. METHODS: A total of 39 eyes from 39 patients were retrospectively enrolled in the study. All eyes that fulfilled the key criteria, including a baseline vision between 20 and 70 ETDRS letters and a minimum central macular thickness (CMT) of 300 µm, had at least 3 monthly loading injections of ranibizumab in a year. Macular laser or posterior subtenon injections of triamcinolone acetonide (PSTA) could be performed as supplementary treatments following loading injections. Primary outcomes include best-corrected visual acuity and CMT. RESULTS: Patients' vision improved from 46.5 ± 15.3 letters at baseline to 51.4 ± 16.6 letters at 12 months (p = 0.031). Mean CMT at baseline was 406 ± 105 µm, which decreased to 329 ± 108 µm (p = 0.002). At 12 months, 44.4% of eyes with total injection number < 5 and 42.9% with injection number ≥ 5 achieved a gain in vision that was 10 letters or more. A total of 5 injections or more did not lead to a better visual gain in comparison with only 3-4 injections (p = 0.71), and both had similar number of supplementary treatments (p = 0.43). Monthly reinjections of ranibizumab resulted in a lower likelihood of visual loss of 10 or 15 letters (p = 0.019 and 0.015, respectively, adjusted for age, baseline vision, severity of diabetic retinopathy and the presence of previous treatments); however, supplementary macular lasers, PSTA or ranibizumab without monthly reinjections did not (all p > 0.05). The average number of injections was 4.3 ± 1.0. CONCLUSION: Treatment for DME with at least three monthly ranibizumab loading injections, with or without other supplementary treatments, is effective at 12 months thereafter. Two monthly reinjections of ranibizumab, while not significantly increasing vision, may have a role in preventing visual loss.


Assuntos
Retinopatia Diabética/complicações , Macula Lutea/patologia , Edema Macular/tratamento farmacológico , Ranibizumab/administração & dosagem , Acuidade Visual , Inibidores da Angiogênese/administração & dosagem , Retinopatia Diabética/tratamento farmacológico , Retinopatia Diabética/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Injeções Intravítreas , Edema Macular/epidemiologia , Edema Macular/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taiwan/epidemiologia , Tomografia de Coerência Óptica , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores
9.
Clin Ophthalmol ; 12: 1229-1235, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30013316

RESUMO

AIM: To compare the efficacy and safety between posterior sub-tenon injection of triamcinolone acetonide (PSTA) and intravitreal injection of bevacizumab (Avastin) (IVIA) in the treatment of macular edema secondary to retinal vein occlusion. PATIENTS AND METHODS: A total of 45 eyes were retrospectively enrolled (23 eyes with intravitreal bevacizumab and 22 eyes with posterior sub-tenon triamcinolone acetonide). Main endpoints included logMAR of best-corrected visual acuity (BCVA), central macular thickness (CMT), and intraocular pressure (IOP) before and after treatment at 6 months. RESULTS: The mean logMAR improved from 0.78 to 0.56 at 6 months for intravitreal bevacizumab (p=0.001), and from 0.91 to 0.79 and 0.87 at 3 and 6 months (p=0.038 and 0.13), respectively, for sub-tenon triamcinolone acetonide. At 6 months, the BCVA was significantly better in the bevacizumab group (p=0.02). Both groups' mean CMT significantly improved, from 478 µm at baseline to 295 µm at 6 months in IVIA group (p<0.001) and from 419 µm at baseline to 350 µm in PSTA group (p=0.012); however, this was not different between the groups at 6 months (p=0.065). Recurrence of macular edema was not different between the groups either (p=0.08). Poorer final vision was associated with poorer baseline BCVA and diagnosis of central retinal vein occlusion after adjustment for age and sex (p<0.001 and 0.012, respectively). Significant elevation of IOP was noted at 3 months in the PSTA group, but declined at 6 months compared with baseline (p=0.002 and 0.41, respectively). CONCLUSION: Intravitreal bevacizumab seemed to achieve better visual acuity compared with posterior sub-tenon injections of triamcinolone acetonide at 6 months, while CMT was comparable. PSTA still resulted in transient IOP elevation.

10.
Diab Vasc Dis Res ; 15(2): 165-168, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29212365

RESUMO

PURPOSE: To investigate the impact of metabolic control on macular thickness measured using optical coherence tomography in patients with diabetic retinopathy with or without macular oedema. METHODS: A total of 124 patients with diabetic retinopathy ( n = 70 without macular oedema and n = 54 with macular oedema) were enrolled. Optical coherence tomography parameters measured included central macular thickness and total macular volume. Metabolic factors with correlation to optical coherence tomography parameters were fasting plasma glucose, glycosylated haemoglobin, triglyceride, low-density lipoprotein and estimated glomerular filtration rate. Multiple linear regression models were used to evaluate associations between optical coherence tomography parameters and metabolic factors. RESULTS: Higher glycosylated haemoglobin values were correlated with increased central macular thickness in patients without macular oedema ( R = 0.289, p = 0.015), whereas glycosylated haemoglobin values were inversely associated with central macular thickness in patients with macular oedema ( R = -0.374, p = 0.005). Both were found to be statistically significant after adjusting for age, sex and diabetic retinopathy severity in addition to other metabolic factors ( p = 0.009 and p = 0.002, respectively). CONCLUSION: Strict metabolic control may not be associated with better macular thickness in diabetic patients with co-existing macular oedema.


Assuntos
Retinopatia Diabética/metabolismo , Hemoglobinas Glicadas/metabolismo , Lipídeos/sangue , Edema Macular/patologia , Adulto , Idoso , Retinopatia Diabética/fisiopatologia , Feminino , Hemoglobinas/metabolismo , Humanos , Edema Macular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica/métodos
11.
J Ophthalmol ; 2017: 4834201, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28819567

RESUMO

PURPOSE: To investigate the impact of systemic diseases on the occurrence of subretinal fluid (SRF) in diabetic macular edema (DME) and prognostic factors for residual SRF following three consecutive monthly intravitreal ranibizumab. METHODS: Ninety-seven eyes from 68 patients with DME who completed 3 consecutive monthly injections of ranibizumab were enrolled. Systemic parameters mainly included chronic kidney disease (CKD), hypertension, HbA1c, and insulin dependence. Renal parameters for CKD were serum creatinine, estimated glomerular filtration rate (eGFR), and serum albumin. Ocular factors were baseline central macular thickness (CMT), severity of diabetic retinopathy (DR), and status of panretinal photocoagulation (PRP). RESULTS: Chronic kidney disease had significant correlation with baseline SRF (R = 0.397, p < 0.001 after partial correlation with adjustment for age and DR severity). As for CKD, lower serum albumin, but not eGFR or serum creatinine, was associated with baseline presence of SRF (p = 0.026, p = 0.08 and p = 0.53, resp., after adjustment for age and DR severity). Overall, lower eGFR and lower HbA1c values, contrary to popular belief, predicted the presence of residual SRF following intravitreal injections (p = 0.016 and p < 0.001, resp.). CONCLUSIONS: Tight sugar control and poorer baseline kidney function may slow the resorption of SRF after anti-VEGF injections in patients with DME in the short term.

12.
J Biomed Mater Res A ; 101(1): 167-75, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22829533

RESUMO

The purpose of this report was to develop biodegradable balloon-expandable self-locking poly(ε-caprolactone) (PCL) stents for the treatment of retinal detachment. To create the biodegradable stents, polycaprolactone components were first fabricated by a laboratory-scale microinjection molding machine. The components were then assembled into mesh-like stents of 6 and 8 mm in diameter. A special geometry of the components was designed to self-lock the assembled stents after being expanded by balloons. Characterization of the biodegradable PCL stents was carried out. PCL stents exhibited comparable mechanical properties with that of silicone sponge. Neither significant amount of collapse pressure reduction nor weight loss of the stents was observed after being submerged in phosphate buffered saline for 30 days. In addition, the stents were also implanted in the episcleral space of 10 New Zealand white rabbits. The stents were placed in radial direction and left unsutured after balloon expansion. The stents achieved an efficient buckling effect in echographic and fundus photographic examinations. The ocular pressure was significantly elevated after stent implantation and gradually normalized after the second week. The computed tomography studies verified the hypothesis of minimal migration of the PCL stents. The in vivo result suggests that balloon-expandable biodegradable stents can potentially serve as an ideal indenting biomaterial in retinal detachment surgery.


Assuntos
Materiais Biocompatíveis/farmacologia , Implantes Experimentais , Poliésteres/farmacologia , Descolamento Retiniano/terapia , Stents , Animais , Materiais Biocompatíveis/química , Biodegradação Ambiental , Força Compressiva/efeitos dos fármacos , Imageamento Tridimensional , Pressão Intraocular/efeitos dos fármacos , Órbita/diagnóstico por imagem , Órbita/efeitos dos fármacos , Órbita/patologia , Órbita/cirurgia , Periósteo/efeitos dos fármacos , Periósteo/patologia , Periósteo/fisiopatologia , Periósteo/cirurgia , Poliésteres/química , Coelhos , Descolamento Retiniano/diagnóstico por imagem , Descolamento Retiniano/patologia , Descolamento Retiniano/cirurgia , Tomografia Computadorizada por Raios X , Ultrassonografia
13.
J Biomed Mater Res A ; 100(5): 1126-35, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22337602

RESUMO

The purpose of this study is to evaluate the angiogenic potential of collagen-glycosaminoglycan (CG) matrices in mitomycin C-induced ischemic conjunctival defect, in New Zealand white rabbits. After creating a conjunctival defect at the center of ischemic conjunctiva, a CG matrix was implanted into subconjunctival space to evaluate the conjunctival reepithelialization and angiogenesis during the wound healing process. In the grafted group, the vessel count of the healed conjunctiva was substantially elevated by two fold within the initial 4 weeks and the increased vascular content originated mostly from the fornix site. The rate of conjunctival reepithelialization was not retarded in the grafted group, and the final thickness of healed conjunctiva was similar in both grafted and ungrafted groups. The histological studies revealed that the collagen matrix did not elicit pronounced inflammatory reaction and the regenerated conjunctiva showed loosely arranged collagen deposition without significant scar formation. The α SMA staining positive myofibroblasts were identified in the acute inflammatory stage and were absent, 8 weeks after implantation in both groups. The results indicated that the porous collagen scaffold was able to enhance vascularization and physiological recovery of ischemic conjunctival defect, implying a potential alternative therapy for the ischemic leaking bleb after glaucoma filtrating surgery in ophthalmic practices.


Assuntos
Túnica Conjuntiva/irrigação sanguínea , Isquemia/prevenção & controle , Engenharia Tecidual/métodos , Animais , Antígenos CD34/metabolismo , Materiais Biocompatíveis/farmacologia , Colágeno/farmacologia , Túnica Conjuntiva/efeitos dos fármacos , Túnica Conjuntiva/patologia , Matriz Extracelular/efeitos dos fármacos , Matriz Extracelular/metabolismo , Imunofluorescência , Glicosaminoglicanos/farmacologia , Isquemia/patologia , Mitomicina , Coelhos , Coloração e Rotulagem , Cicatrização/efeitos dos fármacos
14.
Chest ; 141(5): 1197-1202, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-21960700

RESUMO

BACKGROUND: Inadequate localized drug concentrations and systemic adverse effects are among the concerns when regional infections are treated with systemic antibiotics. We designed and fabricated a poly(D,L)-lactide-co-glycolide (PLGA)-based biodegradable drug delivery system and evaluated the release of antibiotics both in vitro and in vivo. METHODS: PLGA copolymer and penicillin G sodium were mixed, compressed, and sintered to fabricate biodegradable antibiotic beads. The beads were placed in phosphate-buffered saline to test the characteristics of in vitro drug release. The beads then were introduced into the pleural cavities through chest tubes of six New Zealand white rabbits. Daily pleural effusion was collected to measure the antibiotic concentration and bacterial inhibitory characteristics. RESULTS: Forty percent of the penicillin was released in the first day in the in vitro study. The rest of the antibiotic was then gradually released in the following 30 days. All six animals survived the experiment. The initial surge of drug release was less significant in the pleural cavity than in the phosphate-buffered saline. The drug concentrations were well above the minimum inhibitory concentration breakpoint for penicillin susceptibility throughout the study period in both in vitro (30 days) and in vivo (14 days) studies. CONCLUSIONS: These preliminary findings demonstrated that the biodegradable PLGA antibiotic beads could achieve a fairly steady antibiotic release in the pleural cavity for at least 2 weeks. This drug delivery system may have the potential to serve as an adjuvant treatment of pleural cavity infection.


Assuntos
Implantes Absorvíveis , Antibacterianos/farmacocinética , Bombas de Infusão Implantáveis , Ácido Láctico , Pasteurella multocida/efeitos dos fármacos , Penicilina G/farmacocinética , Cavidade Pleural/efeitos dos fármacos , Cavidade Pleural/metabolismo , Ácido Poliglicólico , Animais , Disponibilidade Biológica , Tubos Torácicos , Cromatografia Líquida de Alta Pressão , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão , Relação Dose-Resposta a Droga , Técnicas In Vitro , Microesferas , Cavidade Pleural/microbiologia , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Coelhos
15.
Retin Cases Brief Rep ; 6(3): 263-5, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-25389727

RESUMO

PURPOSE: The purpose of this study was to describe a new technique for treating a case of angle closure glaucoma secondary to posterior chamber (PC) gas entrapment after intravitreal C3F8 injection. METHODS: Retrospective case report. RESULTS: A 26-year-old woman received intravitreal injection of 0.4 mL of C3F8 after segmental scleral buckling for retinal detachment of her phakic eye. Prone positioning was not maintained postoperatively, and severe eye pain developed within hours of surgery. Intraocular pressure increased to 50 mmHg, and PC was found to be filled with gas accompanying with 360° iridocorneal apposition and angle closure. Transcleral PC paracentesis was performed to evacuate the gas. Anterior chamber angle was reopened inferiorly, and intraocular pressure dropped to 13 mmHg immediately and remained normal. No evidence of lens or iris damage was noted. Postoperatively, the vision improved to 20/25 without major sequelae. CONCLUSION: Posterior chamber gas entrapment with anterior chamber collapse is a rare complication of intravitreal gas injection in phakic eyes. Transcleral PC paracentesis is a safe way to treat angle closure glaucoma secondary to PC gas entrapment.

16.
Inorg Chem ; 50(7): 3078-86, 2011 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-21381676

RESUMO

Ethylene cross-bridged tetraamine macrocycles are useful chelators in coordination, catalytic, medicinal, and radiopharmaceutical chemistry. Springborg and co-workers developed trimethylene cross-bridged analogues, although their pendant-armed derivatives received little attention. We report here the synthesis of a bis-carboxymethyl pendant-armed cyclen with a trimethylene cross-bridge (C3B-DO2A) and its isomeric ethylene-cross-bridged homocyclen ligand (CB-TR2A) as well as their copper(II) complexes. The in vitro and in vivo properties of these complexes are compared with respect to their potential application as (64)Cu-radiopharmaceuticals in positron emission tomography (PET imaging). The inertness of Cu-C3B-DO2A to decomplexation is remarkable, exceeding that of Cu-CB-TE2A. Electrochemical reduction of Cu-CB-TR2A is quasi-reversible, whereas that of Cu-C3B-DO2A is irreversible. The reaction conditions for preparing (64)Cu-C3B-DO2A (microwaving at high temperature) are relatively harsh compared to (64)Cu-CB-TR2A (basic ethanol). The in vivo behavior of the (64)Cu complexes was evaluated in normal rats. Rapid and continual clearance of (64)Cu-CB-TR2A through the blood, liver, and kidneys suggests relatively good in vivo stability, albeit inferior to (64)Cu-CB-TE2A. Although (64)Cu-C3B-DO2A clears continually, the initial uptake is high and only about half is excreted within 22 h, suggesting poor stability and transchelation of (64)Cu to proteins in the blood and/or liver. These data suggest that in vitro inertness of a chelator complex may not always be a good indicator of in vivo stability.


Assuntos
Compostos Aza/química , Cobre/química , Ciclopropanos/química , Etilenos/química , Compostos Organometálicos/química , Cristalografia por Raios X , Compostos Macrocíclicos/química , Modelos Moleculares , Estrutura Molecular , Compostos Organometálicos/síntese química , Estereoisomerismo
17.
J Thorac Cardiovasc Surg ; 141(2): 463-8, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20884017

RESUMO

OBJECTIVE: Despite metallic and silicone stents being effective in treating various airway lesions, many concerns still remain. A bioresorbable stent that scaffolds the airway lumen and dissolves after the remodeling process is completed has advantages over metallic and silicone stents. We designed and fabricated a new mesh-type bioresorbable stent with a backbone of polycaprolactone (PCL), and evaluated its safety and biocompatibility in a rabbit trachea model. METHODS: The PCL stent was fabricated by a laboratory-made microinjection molding machine. In vitro mechanical strength of the PCL stents was tested and compared to that of commercial silicone stents. The bioresorbable stents were surgically implanted into the cervical trachea of New Zealand white rabbits (n=6). Animals received bronchoscopic examination at 1, 2, 4, 8, and 12 weeks after surgery. Histological examination was completed to evaluate the biocompatibility of the stents. RESULTS: No animals died during the period of study. Distal stent migration was noted in 1 rabbit. In-stent secretion accumulation was found in 2 rabbits. Histological examination showed intact ciliated epithelium and marked leukocyte infiltration in the submucosa of the stented area at 10 and 28 weeks. Stent degradation was minimal, and the mechanical strength was well preserved at the end of 33 weeks. CONCLUSIONS: These preliminary findings showed good safety and biocompatibility of the new PCL stent when used in the airway remodeling. PCL could be a promising bioresorbable material for stent design if prolonged degradation time is required.


Assuntos
Implantes Absorvíveis , Remodelação das Vias Aéreas , Stents , Traqueia/cirurgia , Animais , Broncoscopia , Migração de Corpo Estranho/etiologia , Teste de Materiais , Poliésteres , Desenho de Prótese , Coelhos , Stents/efeitos adversos , Estresse Mecânico , Fatores de Tempo , Traqueia/patologia , Traqueia/fisiopatologia
18.
Ophthalmic Genet ; 32(1): 31-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21174521

RESUMO

BACKGROUND: The aim of this paper is to describe the clinical features and molecular findings of a unique case of Leber's hereditary optic neuropathy (LHON)/mitochondrial encephalopathy, lactic acidosis and stroke-like episodes (MELAS) overlap syndrome presenting as nonischemic central retinal vein occlusion (CRVO). METHODS: An 11-year-old Chinese girl presented with sudden onset of bilateral blurred vision. The clinical history, imaging studies, and molecular analysis results were reviewed. The PubMed and OVID databases were used for literature review. RESULTS: Nonischemic CRVO in the subject's right eye and tortuosity of small and medium-sized retinal arterioles in the left eye were found at initial presentation. Bilateral optic disc pallor was then noted with recovery of CRVO. Severe headache and several stroke-like episodes occurred subsequently, with elevated lactate levels in serum and cerebrospinal fluid. LHON/MELAS overlap syndrome was diagnosed, and mitochondrial DNA sequencing revealed G13513A heteroplasmic mutation. Vision was 20/30 in the right eye and 20/800 in the left eye at the last visit. CONCLUSIONS: Mitochondrial DNA G13513A mutation can cause LHON/MELAS overlap syndrome. Nonischemic CRVO is a rare manifestation of LHON/MELAS. Atypical findings in cases of LHON should raise the suspicion of overlap syndrome or other mitochondrial diseases.


Assuntos
DNA Mitocondrial/genética , Síndrome MELAS/diagnóstico , Atrofia Óptica Hereditária de Leber/diagnóstico , Mutação Puntual , Oclusão da Veia Retiniana/diagnóstico , Sequência de Bases , Criança , Feminino , Angiofluoresceinografia , Humanos , Síndrome MELAS/genética , Imageamento por Ressonância Magnética , Dados de Sequência Molecular , Atrofia Óptica Hereditária de Leber/genética , Oclusão da Veia Retiniana/genética , Acuidade Visual
19.
J Biomed Mater Res A ; 94(2): 426-32, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20186737

RESUMO

Delivering effective drugs at sufficiently high concentrations to the area of infection is a standard treatment for infectious disease, such as endophthalmitis. This is currently done by empirical trans pars plana intravitreal injection of both antibiotics directed against gram-positive and gram-negative microorganisms and steroids. However, injections by needles repeatedly may increase the risks of intraocular infection and hemorrhage, as well as retinal detachment. This article explores the alternative of using biodegradable polymers as scleral plugs for a long-term drug release in vivo. To manufacture plugs, poly(lactide-glycolide) copolymers were first mixed with vancomycin, amikacin, and dexamethasone. The mixture was compressed and sintered at 55 degrees C to form scleral plugs 1.4 mm in diameter. Biodegradable scleral plugs released high concentrations of antibiotics (well above the minimum inhibitory concentrations, MIC) and steroids in vivo for the period of time needed to treat intraocular infection. In addition, no major complications such as infectious or sterile endophthalmitis, retinal detachment, ocular phthisis, or uvea protrusion at sclerotomy site were observed throughout the experiment. The sclerotomy wound healed after total degradation of the scleral implants without leakage or local necrosis. Antibiotic/steroid-impregnated biodegradable scleral plugs may have a potential role in the treatment of various intraocular infections.


Assuntos
Amicacina/administração & dosagem , Antibacterianos/administração & dosagem , Anti-Inflamatórios/administração & dosagem , Dexametasona/administração & dosagem , Sistemas de Liberação de Medicamentos , Esclera/cirurgia , Vancomicina/administração & dosagem , Amicacina/farmacocinética , Amicacina/farmacologia , Amicacina/uso terapêutico , Animais , Antibacterianos/farmacocinética , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Anti-Inflamatórios/farmacocinética , Anti-Inflamatórios/farmacologia , Anti-Inflamatórios/uso terapêutico , Materiais Biocompatíveis/química , Materiais Biocompatíveis/metabolismo , Dexametasona/farmacocinética , Dexametasona/farmacologia , Dexametasona/uso terapêutico , Portadores de Fármacos/química , Portadores de Fármacos/metabolismo , Endoftalmite/tratamento farmacológico , Ácido Láctico/química , Ácido Láctico/metabolismo , Teste de Materiais , Ácido Poliglicólico/química , Ácido Poliglicólico/metabolismo , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Próteses e Implantes , Coelhos , Esclera/anatomia & histologia , Esclera/efeitos dos fármacos , Esclera/patologia , Solventes , Vancomicina/farmacocinética , Vancomicina/farmacologia , Vancomicina/uso terapêutico
20.
Biomaterials ; 31(7): 1773-9, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19969344

RESUMO

The purpose of this report was to develop solvent-free biodegradable scleral plugs for simultaneous ganciclovir and foscarnet delivery for cytomegalovirus retinitis treatment. To fabricate a biodegradable plug, polylactide-polyglycolide copolymers were pre-mixed with the drugs. The mixture was then compression molded and sintered to form a compact scleral plug. The drug release features were monitored with HPLC assay both in vitro and in vivo. Both drugs showed a biphasic release curvature with an initial burst and followed by a second sustained release phase and maintained at therapeutic level for 3-4 weeks. As compared to ganciclovir, foscarnet was released faster in initial phase, but later, showed extended retention in vitreous humor. For biocompatibility analysis, dark-adapted flash electroretinography was performed, and the a-wave and b-wave amplitudes were statistically equal before and after the scleral plug implantation. Finally, serial microstructure changes of releasing scleral plugs were evaluated with scanning electron microscope. The scleral plug surface showed progressive transformation from granular solid surface to smoothen and cavitated appearance.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Retinite por Citomegalovirus/tratamento farmacológico , Foscarnet/uso terapêutico , Ganciclovir/uso terapêutico , Esclera/patologia , Animais , Materiais Biocompatíveis/farmacocinética , Cromatografia Líquida de Alta Pressão , Túnica Conjuntiva/patologia , Retinite por Citomegalovirus/patologia , Adaptação à Escuridão , Preparações de Ação Retardada , Eletrorretinografia , Foscarnet/farmacocinética , Ganciclovir/farmacocinética , Implantação de Prótese , Coelhos , Esclera/ultraestrutura , Esclerostomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...