Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Soc Mass Spectrom ; 35(6): 1292-1300, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38662593

RESUMO

Endogenous antibodies, or immunoglobulins (Igs), abundantly present in body fluids, represent some of the most challenging samples to analyze, largely due to the immense variability in their sequences and concentrations. It has been estimated that our body can produce billions of different Ig proteins with different isotypes, making their individual analysis seemingly impossible. However, recent advances in protein-centric proteomics using LC-MS coupled to Orbitrap mass analyzers to profile intact Fab fragments formed by selective cleavage at the IgG-hinge revealed that IgG repertoires may be less diverse, albeit unique for each donor. Serum repertoires seem to be dominated by a few hundred clones that cumulatively make up 50-95% of the total IgG content. Enabling such analyses required careful optimization of the chromatography and mass analysis, as all Fab analytes are highly alike in mass (46-51 kDa) and sequence. To extend the opportunities of this mass-spectrometry-based profiling of antibody repertoires, we here report the optimization and evaluation of an alternative MS platform, namely, the timsTOF, for antibody repertoire profiling. The timsTOF mass analyzer has gained traction in recent years for peptide-centric proteomics and found wide applicability in plasma proteomics, affinity proteomics, and HLA peptidomics, to name a few. However, for protein-centric analysis, this platform has been less explored. Here, we demonstrate that the timsTOF platform can be adapted to perform protein-centric LC-MS-based profiling of antibody repertoires. In a side-by-side comparison of the timsTOF and the Orbitrap we demonstrate that the extracted serum antibody repertoires are alike qualitatively and quantitatively, whereby in particular the sensitivity of the timsTOF platform excels. Future incorporation of advanced top-down capabilities on the timsTOF may make this platform a very valuable alternative for protein-centric proteomics and top-down proteomics and thus also for personalized antibody repertoire profiling.


Assuntos
Fragmentos Fab das Imunoglobulinas , Espectrometria de Massas , Proteômica , Humanos , Fragmentos Fab das Imunoglobulinas/química , Fragmentos Fab das Imunoglobulinas/análise , Fragmentos Fab das Imunoglobulinas/sangue , Cromatografia Líquida/métodos , Proteômica/métodos , Espectrometria de Massas/métodos , Imunoglobulina G/sangue , Imunoglobulina G/química , Imunoglobulina G/análise , Medicina de Precisão/métodos , Espectrometria de Massa com Cromatografia Líquida
2.
Electrophoresis ; 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38085142

RESUMO

Ion mobility-mass spectrometry (IM-MS) is an ever-evolving tool to separate ions in the gas phase according to electrophoretic mobility with subsequent mass determination. CE is rarely coupled to IM-MS, possibly due to similar separation mechanisms based on electrophoretic mobility. Here, we investigate the orthogonality of CE and ion mobility (IM) by analyzing a complex peptide mixture (tryptic digest of HeLa proteins) with trapped ion mobility mass spectrometry (TIMS-MS). Using the nanoCEasy interface, excellent sensitivity was achieved by identifying thousands of peptides and achieving a peak capacity of 7500 (CE: 203-323 in a 150 cm long capillary, IM: 27-31). Plotting CE versus mass and CE versus (inverse) mobility, a clear grouping in curved striped patterns is observed according to the charge-to-size and mass-to-charge ratios. The peptide charge in the acidic background electrolyte can be estimated from the number of basic amino acids, with a few exceptions where neighboring effects reduce the positive charge. A surprisingly high orthogonality of CE and IM is observed, which is obviously caused by solvation effects leading to different charges and sizes in the liquid phase compared to the gas phase. A high orthogonality of CE and ion mobility is expected to be observed for other peptide samples as well as other substance classes, making CE-IM-MS a promising tool for various applications.

3.
J Adv Res ; 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37683725

RESUMO

INTRODUCTION: The human plasma glycoproteome holds enormous potential to identify personalized biomarkers for diagnostics. Glycoproteomics has matured into a technology for plasma N-glycoproteome analysis but further evolution towards clinical applications depends on the clinical validity and understanding of protein- and site-specific glycosylation changes in disease. OBJECTIVES: Here, we exploited the uniqueness of a patient cohort of genetic defects in well-defined glycosylation pathways to assess the clinical applicability of plasma N-glycoproteomics. METHODS: Comparative glycoproteomics was performed of blood plasma from 40 controls and 74 patients with 13 different genetic diseases that impact the protein N-glycosylation pathway. Baseline glycosylation in healthy individuals was compared to reference glycome and intact transferrin protein mass spectrometry data. Use of glycoproteomics data for biomarker discovery and sample stratification was evaluated by multivariate chemometrics and supervised machine learning. Clinical relevance of site-specific glycosylation changes were evaluated in the context of genetic defects that lead to distinct accumulation or loss of specific glycans. Integrated analysis of site-specific glycoproteome changes in disease was performed using chord diagrams and correlated with intact transferrin protein mass spectrometry data. RESULTS: Glycoproteomics identified 191 unique glycoforms from 58 unique peptide sequences of 34 plasma glycoproteins that span over 3 magnitudes of abundance in plasma. Chemometrics identified high-specificity biomarker signatures for each of the individual genetic defects with better stratification performance than the current diagnostic standard method. Bioinformatic analyses revealed site-specific glycosylation differences that could be explained by underlying glycobiology and protein-intrinsic factors. CONCLUSION: Our work illustrates the strong potential of plasma glycoproteomics to significantly increase specificity of glycoprotein biomarkers with direct insights in site-specific glycosylation changes to better understand the glycobiological mechanisms underlying human disease.

4.
Methods Mol Biol ; 2313: 207-217, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34478140

RESUMO

Biopharmaceutical sequences can be well confirmed by multiple protease digests-e.g., trypsin, elastase, and chymotrypsin-followed by LC-MS/MS data analysis. High quality data can be used for de novo sequencing as well. PASEF (Parallel Accumulation and Serial Fragmentation) on the timsTOF instrument has been used to accelerate proteome and protein sequence studies and increase sequence coverage concomitantly.Here we describe the protein chemical and LC-MS methods in detail to generate high quality samples for sequence characterization from only 3 digests. We applied PASEF to generate exhaustive protein sequence coverage maps by combination of results from the three enzyme digests using a short LC gradient. The data quality obtained was high and adequate for determining antibody sequences de novo.Nivolumab and dulaglutide were digested by 3 enzymes individually. For nivolumab, 94/94/90% sequence coverage and 86/84/85% fragment coverage were obtained from the individual digest analysis with trypsin/chymotrypsin/elastase, respectively. For dulaglutide, 96/100/90% sequence coverage and 92/90/83% fragment coverage were obtained. The merged peptide map from the 3 digests for nivolumab resulted in ∼550 peptides; enough to safely confirm the full sequences and to determine the nivolumab sequence de novo.


Assuntos
Confiabilidade dos Dados , Cromatografia Líquida , Quimotripsina , Nivolumabe , Elastase Pancreática , Peptídeos , Proteoma , Análise de Sequência de Proteína , Espectrometria de Massas em Tandem , Tripsina
5.
Anal Chem ; 93(17): 6839-6847, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33871970

RESUMO

As the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic is still ongoing and dramatically influences our life, the need for recombinant viral proteins for diagnostics, vaccine development, and research is very high. The spike (S) protein, and particularly its receptor-binding domain (RBD), mediates the interaction with the angiotensin-converting enzyme 2 (ACE2) receptor on host cells and may be modulated by its structural features. Therefore, well-characterized recombinant RBDs are essential. We have performed an in-depth structural and functional characterization of RBDs expressed in Chinese hamster ovary (CHO) and human embryonic kidney 293 (HEK293) cells. To structurally characterize the native RBDs (comprising N- and O-glycans and additional post translational modifications), a multilevel mass spectrometric approach was employed. Released glycan and glycopeptide analysis were integrated with intact mass analysis, glycan-enzymatic dissection, and top-down sequencing for comprehensive annotation of RBD proteoforms. The data showed distinct glycosylation for CHO- and HEK293-RBD with the latter exhibiting antenna fucosylation, a higher level of sialylation, and a combination of core 1 and core 2 type O-glycans. Additionally, using an alternative approach based on N-terminal cleavage of the O-glycosylation, the previously unknown O-glycosylation site was localized at T323. For both RBDs, the binding to SARS-CoV-2 antibodies of positive patients and affinity to the ACE2 receptor was addressed showing comparable results. This work not only offers insights into RBD structural and functional features but also provides an analytical workflow for characterization of new RBDs and batch-to-batch comparison.


Assuntos
COVID-19 , Glicoproteína da Espícula de Coronavírus , Animais , Células CHO , Cricetinae , Cricetulus , Células HEK293 , Humanos , Ligação Proteica , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/metabolismo
6.
Anal Chem ; 92(16): 10920-10924, 2020 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-32806900

RESUMO

Disulfide bonds within cysteine-rich peptides are important for their stability and biological function. In this respect, the correct disulfide connectivity plays a decisive role. The differentiation of individual disulfide-bonded isomers by traditional high-performance liquid chromatography (HPLC) and mass spectrometry (MS) is limited due to the similarity in physicochemical properties of the isomers sharing the same amino acid sequence. By using trapped ion mobility spectrometry-mass spectrometry (TIMS-MS), several 2- and 3-disulfide-bonded isomers of the µ-conotoxin PIIIA were investigated for their distinguishability by collision cross section (CCS) values and their characteristic mobilogram traces. The isomers could be differentiated by TIMS-MS and also identified in mixing experiments. Thus, TIMS-MS provides a highly valuable and enriching addition to standard HPLC and MS analysis of conformational isomers of disulfide-rich peptides and proteins.


Assuntos
Conotoxinas/análise , Dissulfetos/análise , Sequência de Aminoácidos , Cromatografia Líquida , Conotoxinas/química , Dissulfetos/química , Espectrometria de Mobilidade Iônica , Isomerismo , Espectrometria de Massas/métodos
7.
J Am Soc Mass Spectrom ; 31(9): 1783-1802, 2020 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-32812765

RESUMO

The Consortium for Top-Down Proteomics (www.topdownproteomics.org) launched the present study to assess the current state of top-down mass spectrometry (TD MS) and middle-down mass spectrometry (MD MS) for characterizing monoclonal antibody (mAb) primary structures, including their modifications. To meet the needs of the rapidly growing therapeutic antibody market, it is important to develop analytical strategies to characterize the heterogeneity of a therapeutic product's primary structure accurately and reproducibly. The major objective of the present study is to determine whether current TD/MD MS technologies and protocols can add value to the more commonly employed bottom-up (BU) approaches with regard to confirming protein integrity, sequencing variable domains, avoiding artifacts, and revealing modifications and their locations. We also aim to gather information on the common TD/MD MS methods and practices in the field. A panel of three mAbs was selected and centrally provided to 20 laboratories worldwide for the analysis: Sigma mAb standard (SiLuLite), NIST mAb standard, and the therapeutic mAb Herceptin (trastuzumab). Various MS instrument platforms and ion dissociation techniques were employed. The present study confirms that TD/MD MS tools are available in laboratories worldwide and provide complementary information to the BU approach that can be crucial for comprehensive mAb characterization. The current limitations, as well as possible solutions to overcome them, are also outlined. A primary limitation revealed by the results of the present study is that the expert knowledge in both experiment and data analysis is indispensable to practice TD/MD MS.


Assuntos
Anticorpos Monoclonais , Espectrometria de Massas/métodos , Proteômica/métodos , Animais , Anticorpos Monoclonais/análise , Anticorpos Monoclonais/química , Anticorpos Monoclonais/genética , Regiões Determinantes de Complementaridade/análise , Regiões Determinantes de Complementaridade/química , Regiões Determinantes de Complementaridade/genética , Humanos , Camundongos
8.
Anal Chem ; 92(11): 7453-7461, 2020 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-32427467

RESUMO

Hydrogen/deuterium exchange monitored by mass spectrometry (HDX-MS) enables the study of protein dynamics by measuring the time-resolved deuterium incorporation into a protein incubated in D2O. Using electron-based fragmentation in the gas phase it is possible to measure deuterium uptake at single-residue resolution. However, a prerequisite for this approach is that the solution-phase labeling is conserved in the gas phase prior to precursor fragmentation. It is therefore essential to reduce or even avoid intramolecular hydrogen/deuterium migration, which causes randomization of the deuterium labels along the peptide (hydrogen scrambling). Here, we describe an optimization strategy for reducing scrambling to a negligible level while minimizing the impact on sensitivity on a high-resolution Q-TOF equipped with ETD and an electrospray ionization interface consisting of a glass transfer capillary followed by a dual ion funnel. In our strategy we narrowed down the optimization to two accelerating potentials, and we defined the optimization of these in a simple rule by accounting for their interdependency in relation to scrambling and transmission efficiency. Using this rule, we were able to reduce scrambling from 75% to below 5% on average using the highly scrambling-sensitive quadruply charged P1 peptide scrambling probe resulting in a minor 33% transmission loss. To demonstrate the applicability of this approach, we probe the dynamics of certain regions in cytochrome c.

9.
Mol Cell Proteomics ; 19(1): 11-30, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31591262

RESUMO

Glycosylation is a topic of intense current interest in the development of biopharmaceuticals because it is related to drug safety and efficacy. This work describes results of an interlaboratory study on the glycosylation of the Primary Sample (PS) of NISTmAb, a monoclonal antibody reference material. Seventy-six laboratories from industry, university, research, government, and hospital sectors in Europe, North America, Asia, and Australia submitted a total of 103 reports on glycan distributions. The principal objective of this study was to report and compare results for the full range of analytical methods presently used in the glycosylation analysis of mAbs. Therefore, participation was unrestricted, with laboratories choosing their own measurement techniques. Protein glycosylation was determined in various ways, including at the level of intact mAb, protein fragments, glycopeptides, or released glycans, using a wide variety of methods for derivatization, separation, identification, and quantification. Consequently, the diversity of results was enormous, with the number of glycan compositions identified by each laboratory ranging from 4 to 48. In total, one hundred sixteen glycan compositions were reported, of which 57 compositions could be assigned consensus abundance values. These consensus medians provide community-derived values for NISTmAb PS. Agreement with the consensus medians did not depend on the specific method or laboratory type. The study provides a view of the current state-of-the-art for biologic glycosylation measurement and suggests a clear need for harmonization of glycosylation analysis methods.


Assuntos
Anticorpos Monoclonais/química , Produtos Biológicos , Biofarmácia/métodos , Anticorpos Monoclonais/metabolismo , Glicômica/métodos , Glicopeptídeos/metabolismo , Glicosilação , Humanos , Laboratórios , Polissacarídeos/metabolismo , Processamento de Proteína Pós-Traducional , Proteômica/métodos
10.
J Am Soc Mass Spectrom ; 27(3): 507-19, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26729457

RESUMO

In-depth site-specific investigations of protein glycosylation are the basis for understanding the biological function of glycoproteins. Mass spectrometry-based N- and O-glycopeptide analyses enable determination of the glycosylation site, site occupancy, as well as glycan varieties present on a particular site. However, the depth of information is highly dependent on the applied analytical tools, including glycopeptide fragmentation regimes and automated data analysis. Here, we used a small set of synthetic disialylated, biantennary N-glycopeptides to systematically tune Q-TOF instrument parameters towards optimal energy stepping collision induced dissociation (CID) of glycopeptides. A linear dependency of m/z-ratio and optimal fragmentation energy was found, showing that with increasing m/z-ratio, more energy is required for glycopeptide fragmentation. Based on these optimized fragmentation parameters, a method combining lower- and higher-energy CID was developed, allowing the online acquisition of glycan and peptide-specific fragments within a single tandem MS experiment. We validated this method analyzing a set of human immunoglobulins (IgA1+2, sIgA, IgG1+2, IgE, IgD, IgM) as well as bovine fetuin. These optimized fragmentation parameters also enabled software-assisted glycopeptide assignment of both N- and O-glycopeptides including information about the most abundant glycan compositions, peptide sequence and putative structures. Twenty-six out of 30 N-glycopeptides and four out of five O-glycopeptides carrying >110 different glycoforms could be identified by this optimized LC-ESI tandem MS method with minimal user input. The Q-TOF based glycopeptide analysis platform presented here opens the way to a range of different applications in glycoproteomics research as well as biopharmaceutical development and quality control.


Assuntos
Fetuínas/química , Glicopeptídeos/análise , Imunoglobulinas/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Sequência de Aminoácidos , Animais , Sequência de Carboidratos , Bovinos , Humanos , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos
11.
Sci Signal ; 4(179): rs6, 2011 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-21712547

RESUMO

Kinases of the Aurora family are essential for the proper execution of mitosis in eukaryotes, and Aurora inhibitors are in clinical trials as anticancer drugs. We applied site-specific quantitative phosphoproteomics in conjunction with chemical inhibition of Aurora to identify mitotic Aurora substrates in fission yeast on a proteome-wide scale. We detected 8000 phosphorylation events, of which we assigned almost 6000 to a specific residue; 220 were reduced in cells exposed to the Aurora inhibitor. After controlling for unspecific effects of the inhibitor, we classified 70 sites (on 42 proteins) as probable targets of Aurora, which enabled refinement of the consensus sequence for phosphorylation by Aurora. Several of the substrate candidates were known targets of Aurora, validating the approach, but most represented newly detected Aurora substrates. The involvement of these Aurora substrates in diverse aspects of chromatin dynamics suggests that in addition to its established role in controlling chromosome compaction and attachment to the mitotic spindle, Aurora influences other aspects of chromatin architecture and function during mitosis.


Assuntos
Cromatina/metabolismo , Mitose/fisiologia , Proteínas Serina-Treonina Quinases/metabolismo , Proteoma/metabolismo , Proteínas de Schizosaccharomyces pombe/metabolismo , Schizosaccharomyces/metabolismo , Aurora Quinases , Fosforilação/fisiologia , Proteômica/métodos , Fuso Acromático/metabolismo
12.
Protein Expr Purif ; 48(2): 173-81, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16797185

RESUMO

The expression of proteins using recombinant baculoviruses is a mature and widely used technology. However, some aspects of the technology continue to detract from high throughput use and the basis of the final observed expression level is poorly understood. Here, we describe the design and use of a set of vectors developed around a unified cloning strategy that allow parallel expression of target proteins in the baculovirus system as N-terminal or C-terminal fusions. Using several protein kinases as tests we found that amino-terminal fusion to maltose binding protein rescued expression of the poorly expressed human kinase Cot but had only a marginal effect on expression of a well-expressed kinase IKK-2. In addition, MBP fusion proteins were found to be secreted from the expressing cell. Use of a carboxyl-terminal GFP tagging vector showed that fluorescence measurement paralleled expression level and was a convenient readout in the context of insect cell expression, an observation that was further supported with additional non-kinase targets. The expression of the target proteins using the same vectors in vitro showed that differences in expression level were wholly dependent on the environment of the expressing cell and an investigation of the time course of expression showed it could affect substantially the observed expression level for poorly but not well-expressed proteins. Our vector suite approach shows that rapid expression survey can be achieved within the baculovirus system and in addition, goes some way to identifying the underlying basis of the expression level obtained.


Assuntos
Baculoviridae/genética , Biotecnologia/métodos , Expressão Gênica/genética , Vetores Genéticos , Sequência de Bases , Vetores Genéticos/genética , Proteínas de Fluorescência Verde , Dados de Sequência Molecular , Proteínas Recombinantes/biossíntese , Proteínas Recombinantes/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...