1.
Ther Adv Ophthalmol ; 12: 2515841420923190, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32577607

RESUMO

PURPOSE: To investigate in vitro the accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas. METHODS: Experimental study included 20 freshly enucleated porcine eyes. Epithelium was debrided, and eyes were divided in four groups. Groups were immersed in 35%, 40%, 50%, and 60% glycerin solutions for 3 hours. Subsequently, globes were mounted in a special holder, and their intraocular pressure was hydrostatically adjusted. Intraocular pressure was measured by means of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL while adjusting true intraocular pressure to 17, 33, and 50 mm Hg. Ultrasound pachymetry was performed. RESULTS: Mean corneal thickness was 914.5 ± 33.3 µm (730-1015 µm). In true intraocular pressure of 33 mm Hg, Goldmann applanation tonometry and dynamic contour tonometry significantly underestimated true intraocular pressure (mean Goldmann applanation tonometry: 14.7 ± 4.8 mm Hg, p < 0.001, mean dynamic contour tonometry: 21.6 ± 6.8, p < 0.001). Tono-Pen XL also underestimated, but difference was not statistically significant (Tono-Pen XL: 27.9 ± 9.7, p = 0.064). In true intraocular pressure of 50 mm Hg, all three methods significantly underestimated (Goldmann applanation tonometry: 17.6 ± 5.3 mm Hg, p < 0.001, dynamic contour tonometry: 26.8 ± 6.3 mm Hg, p < 0.001, Tono-Pen XL: 35.6 ± 8.4 mm Hg, p < 0.001). The error in measured intraocular pressure for each method (true minus measured intraocular pressure) was significantly correlated to true intraocular pressure (p < 0.001). The intraocular pressure measurements of each eye taken under true intraocular pressure of 17 and 33 mm Hg with the three methods were correlated to each other. Measurements taken under intraocular pressure of 50 mmHg were not correlated to each other. Corneal thickness was not correlated to intraocular pressure measurement. CONCLUSION: Goldmann applanation tonometry, dynamic contour tonometry, and Tono-Pen XL underestimate intraocular pressure when measured under edematous conditions. Tono-Pen XL showed better accuracy, especially in lower true intraocular pressure. The measurement error increases when true intraocular pressure increases in all three methods.

2.
Graefes Arch Clin Exp Ophthalmol ; 251(2): 543-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22729432

RESUMO

BACKGROUND: The purpose of this study is to evaluate in-vitro the immediate effect of corneal collagen cross-linking (CXL) on corneal hydration and stiffness. METHODS: Forty-two corneal buttons from freshly enucleated porcine eyes were immersed in riboflavin 0.1% in dextran 20% dilution for 3 h in order for their hydration to reach equilibrium. Corneal buttons where divided into two groups; the first group was stored in dark conditions while the other group was irradiated with UV radiation (370 nm) for 30 min to simulate CXL according to the clinically applied protocol. After irradiation, all corneas were immersed in dextran 20% solution for 3 additional hours. Subsequently, each button underwent weighing, thickness measurement, and was mounted in a special device for the measurement of force versus deformation by compression. Finally, all corneal buttons were dehydrated for 48 h in a desiccating oven set at 62 °C and weighed again to obtain their dry mass. Hydration (%) of each button was calculated. RESULTS: Mean corneal hydration in the irradiated and the non-irradiated group of corneas was 69.8 and 72.2%, respectively (p < 0.001). Differences in thickness and compressibility were not statistically significant. Thickness and hydration were positively correlated (Pearson's r = 0.714, p < 0.001). CONCLUSIONS: CXL causes corneal dehydration that can be detected immediately after the procedure. This phenomenon may contribute to increased mechanical stiffness of the cornea. A change in stiffness by means of compressibility could not be detected in porcine corneas.


Assuntos
Água Corporal/fisiologia , Colágeno/metabolismo , Substância Própria/metabolismo , Reagentes de Ligações Cruzadas/farmacologia , Elasticidade/fisiologia , Maleabilidade/fisiologia , Animais , Córnea/fisiologia , Paquimetria Corneana , Fármacos Fotossensibilizantes/farmacologia , Riboflavina/farmacologia , Suínos , Raios Ultravioleta , Equilíbrio Hidroeletrolítico
3.
Ophthalmic Physiol Opt ; 29(3): 357-62, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19422569

RESUMO

Corneal haze following excimer laser ablation is an adverse after-effect of photorefractive keratectomy (PRK) and is associated with the development of subepithelial opacities. The present work pertains to the measurement of light scattering in rabbit corneas following excimer laser treatment; to the microscopic analysis of the light-scattering corneal structures; and to the development of a mathematical model of light propagation through the post-laser treatment cornea. Photorefractive keratectomy (PRK-6D, 6 mm optical zone) followed by standard postoperative pharmaceutical treatment was performed on rabbit eyes. Animals were examined clinically on a weekly basis and sacrificed after the tenth postoperative week. Confocal microscope image sequences were acquired immediately before animal sacrifice. After the scatter measurement, the corneas were prepared for histopathological evaluation. The subepithelial structures observed using the confocal microscope correspond to refractive index (and therefore optical path difference (OPD) variation. This OPD distribution can be approximated with a fractal surface, band-pass filtered in the Fourier domain. The angular distribution of scattered light is characterised by a narrow forward peak of the order of 0.5 degrees full-width at half maximum (FWHM) in accordance with the sizes of the subepithelial structures (5-150 microm).The intensity of scattered light is correlated with the thickness of the subepithelial scar-tissue layer.


Assuntos
Cicatriz/etiologia , Córnea/cirurgia , Opacidade da Córnea/etiologia , Lasers de Excimer/efeitos adversos , Ceratectomia Fotorrefrativa/efeitos adversos , Espalhamento de Radiação , Animais , Complicações Pós-Operatórias , Coelhos , Transtornos da Visão/etiologia , Cicatrização/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA