Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Odontology ; 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38087010

RESUMO

To evaluate and compare the effect of calcium hydroxide [Ca(OH)2] and 2-hydroxyisocaproic acid (HICA) on the microhardness of root dentine. Fifty-one matured maxillary central incisors with straight root and type I canal configuration were decoronated to a standardized length of 16 mm. The root canals were cleaned and shaped using rotary instruments up to size F5. The tooth samples were then randomly assigned into three groups (n = 17) based on the intracanal medicament placed. Group A: control group with no intracanal medicament, Group B: root canals placed with Ca(OH)2, and Group C: root canals placed with HICA. After 1 week, the intracanal medicaments placed within the root canals were removed and the canals were dried. Subsequently, the specimens were split longitudinally into two halves and subjected to the Vickers microhardness test with indentations made at the coronal, middle, and apical-third root regions. The data were analyzed using one-way ANOVA and Tukey's post hoc tests. The control group showed significantly highest microhardness value (P < 0.001), followed by HICA and finally, Ca(OH)2 at the coronal, middle, and apical-third root regions, respectively. Nonetheless, there were no statistically significant differences in microhardness values across different root regions within each group. HICA was found to have a significantly lesser reduction in root dentine microhardness which could be a potential alternative to Ca(OH)2. Nevertheless, future studies are warranted to verify the present outcomes in the clinical setting.

2.
Saudi Dent J ; 35(5): 468-475, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520597

RESUMO

Purpose: This review aimed to assess the incidence, anatomical characteristics, identification, and clinical management using conventional techniques and advanced tools to manage MMCs successfully. Methods: Medline/PubMed and Scopus databases were searched using "Middle mesial canal," "Middle mesial root canal," OR "Accessory mesial canal" keywords from 1 January 1970 and 1 February 2023. The most pertinent articles were chosen for the review from the retrieved articles. In addition, relevant articles were added by manually searching the list of references. Results: The incidence of MMC is noticeable in younger people, and the confluent canal is the most common type. The majority of MMCs merged with mesiobuccal (MB) canals rather than mesiolingual (ML) canals. Clinical management could be employed using the standard endodontics protocol, and recent radiography technologies, magnification, rotary, and obturation materials can facilitate the procedures. Conclusion: The possibility of the incidence of MMC is not unusual. Detection and thorough debridement followed by obturation of the canal could increase the success rate of clinical outcomes.

3.
Odontology ; 110(1): 106-112, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34269933

RESUMO

To compare the vertical root fracture (VRF) resistance of root canal-treated teeth instrumented with four different nickel-titanium (NiTi) rotary file systems and examine the dentinal crack pattern and direction using a new classification. Eighty mature mandibular premolars were selected and decoronated, leaving 13 mm of the root. The root samples were mounted in acrylic resin and divided randomly into five groups of different NiTi file systems: Group 1-control, Group 2-T-Pro, Group 3-HyFlex CM, Group 4-TG6 and lastly Group 5-ZenFlex. Samples in Group 2 and Group 3 were instrumented up to size 25/0.04, whereas Group 4 and Group 5 were instrumented up to size 25/0.06. Obturation was performed with AH Plus sealer and gutta-percha using single cone technique. Subsequently, all samples were subjected to occlusal compressive force until they were fractured. The force (N) needed to cause root fracture was recorded. The crack patterns and directions were also inspected under magnification and classified using a new and simple classification. The highest (VRF) resistance was noted in the control group (453.15 ± 92.23 N), followed by T-Pro (387.43 ± 76.81 N), HyFlex CM (381.88 ± 52.73 N), ZenFlex (369.15 ± 89.41 N) and finally TG6 (346.05 ± 72.08 N), but there was no significant difference between T-Pro and HyFlex (P = 0.438). A significantly higher prevalence (P = 0.001) of Type 1 crack pattern was observed, especially in samples instrumented with TG6. Majority of the cracks ran buccolingually except in some samples instrumented with ZenFlex (P = 0.898). Smaller file taper increased the VRF resistance of root canal-treated teeth. Majority of the dentinal crack exhibited Type 1 pattern and ran buccolingually.


Assuntos
Níquel , Materiais Restauradores do Canal Radicular , Cavidade Pulpar , Guta-Percha , Obturação do Canal Radicular , Preparo de Canal Radicular , Titânio
4.
J Conserv Dent ; 24(6): 634-639, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35558678

RESUMO

Successful root canal treatment requires a thorough understanding of the normal root canal anatomy and possible variations for each tooth. Variations in the root canal anatomy are frequently associated with complex orientations of pulp tissues and complicating mechanical and chemical debridement. Inability to manage such complications may result in endodontic failure. Mandibular first premolars often exhibit a wide range of anatomic variations, complicating clinicians' treatment. This clinical case report discusses the cone-beam computed tomography (CBCT) diagnosis and nonsurgical management of a taurodontic mandibular first premolar with two roots and four canals under a dental operating microscope (DOM). In endodontically challenging cases, using a DOM and CBCT imaging can help the clinician gain a better understanding of the complex root canal anatomy, allowing the clinician to more efficiently explore, clean, shape, and obturate the root canal system.

5.
J Conserv Dent ; 20(4): 264-268, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29259365

RESUMO

AIM: The purpose of this clinical study was to compare and clinically, to evaluate the accuracy of six apex locators with intra oral periapical (IOPA) radiograph in multirooted teeth. MATERIALS AND METHODS: A total of 90 multirooted teeth (maxillary and mandibular molars) with irreversible, infected or necrotic pulp tissue and completely formed roots were included in this study and were divided randomly into six groups (Root ZX II, Raypex 6, I-Root, Romiapex A-15, Sybron Endo Mini and Root ZX mini). The working length was determined using six different apex locators, and the accuracy of the apex locators was compared with IOPA radiographs, to be categorized as accurate, short, and long or beyond. RESULTS: A total of 270 canals were evaluated, of which 233 (86.3%) canals exhibited acceptable working length, 28 (10.4%) canals exhibited short working length, and only 9 (3.3%) canals exhibited working length beyond the apex. There were a statistically significant results in all the groups (P < 0.05) and the comparison between the groups was statistically insignificant. CONCLUSION: The repeatability with that of apex locators is of great advantage, but the information gained from the radiographs cannot be obtained by any other means. Therefore, it is recommended that radiograph and apex locators are the best combinations in accurately determining the working length and the successful endodontics.

6.
J Clin Diagn Res ; 11(5): ZC29-ZC35, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28658903

RESUMO

INTRODUCTION: The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. AIM: The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. MATERIALS AND METHODS: A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher's-exact test and the Chi-Square test. RESULTS: Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. CONCLUSION: A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with experience, the management of separated file was better.

SELEÇÃO DE REFERÊNCIAS