Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 39(10): 1953-1956, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30237303

RESUMO

BACKGROUND AND PURPOSE: Conventional MR imaging can provide important clues regarding the location of a spinal vascular malformation. We hypothesized that a dilated vein of the filum terminale, identified as a curvilinear flow void on T2WI, could be an imaging marker for a lower lumbar (L3-L5) or sacral fistula. MATERIALS AND METHODS: We retrospectively identified all spinal dural and spinal epidural arteriovenous fistulas from 2 large tertiary referral centers from 2005 to 2018. All patients had a lumbar spinal MR imaging and a conventional spinal angiography. Images were reviewed by 2 neuroradiologists who categorized the level of the arterial feeder to the fistula and the presence or absence of a dilated vein of the filum terminale on T2WI and T1 postcontrast images. We calculated the sensitivity, specificity, positive predictive value, and negative predictive value of the presence of a dilated filum terminale vein for a deep lumbar or sacral fistula. RESULTS: One hundred sixty-two patients were included. An enlarged filum terminale vein was identified in 39 patients. Sensitivity, specificity, positive predictive value, and negative predictive value of the presence of a dilated filum terminale vein for a deep lumbar or sacral fistula were 86%, 98.3%, 94.9%, and 95.1%, respectively. CONCLUSIONS: The presence of a dilated vein of the filum terminale can accurately localize a spinal dural arteriovenous fistula/spinal epidural arteriovenous fistula to the lower lumbar or sacral spine in patients being evaluated for such lesions. This finding can be used to facilitate both noninvasive and conventional spinal angiography.


Assuntos
Fístula Arteriovenosa/diagnóstico por imagem , Cauda Equina/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Veias/efeitos dos fármacos , Adulto , Idoso , Fístula Arteriovenosa/patologia , Cauda Equina/patologia , Malformações Vasculares do Sistema Nervoso Central/patologia , Feminino , Humanos , Região Lombossacral/diagnóstico por imagem , Região Lombossacral/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Veias/patologia
2.
AJNR Am J Neuroradiol ; 36(5): 821-4, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25836726
3.
AJNR Am J Neuroradiol ; 36(5): 819-21, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25742987
4.
AJNR Am J Neuroradiol ; 35(12): 2348-53, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25082824

RESUMO

BACKGROUND AND PURPOSE: Digital subtraction angiography is the gold standard vascular imaging and it is used for all endovascular treatment of intracranial anerysms. Optical flow imaging has been described as a potential method to evaluate cerebral hemodynamics through DSA. In this study, we aimed to compare the flow patterns measured during angiography, by using an optical flow method, with those measured by using computational fluid dynamics in intracranial aneurysms. MATERIALS AND METHODS: A consecutive series of 21 patients harboring unruptured saccular intracranial aneurysms who underwent diagnostic angiography before treatment was considered. High-frame-rate digital subtraction angiography was performed to obtain an intra-aneurysmal velocity field by following the cardiac-modulated contrast wave through the vascular structures by using optical flow principles. Additionally, computational fluid dynamics modeling was performed for every case by using patient-specific inlet-boundary conditions measured with the optical flow method from both DSA and 3D rotational angiography datasets. Three independent observers compared qualitatively both the inflow direction and the apparent recirculation in regular DSA, optical flow images, and computational fluid dynamics flow patterns for each patient; κ statistics were estimated. RESULTS: We included 21 patients. In 14 of these 21, the flow patterns were conclusive and matching between the optical flow images and computational fluid dynamics within the same projection view (κ = .91). However, in only 8 of these 14 patients the optical flow images were conclusive and matching regular DSA images (observer κ = 0.87). In 7 of the 21 patients, the flow patterns in the optical flow images were inconclusive, possibly due to improper projection angles. CONCLUSIONS: The DSA-based optical flow technique was considered qualitatively consistent with computational fluid dynamics outcomes in evaluating intra-aneurysmal inflow direction and apparent recirculation. Moreover, the optical flow technique may provide the premises for new solutions for improving the visibility of flow patterns when contrast motion in DSA is not apparent. This technique is a diagnostic method to evaluate intra-aneurysmal flow patterns and could be used in the future for validation and patient evaluation.


Assuntos
Angiografia Digital/métodos , Hemodinâmica/fisiologia , Hidrodinâmica , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/fisiopatologia , Computação Matemática , Idoso , Angiografia Cerebral/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
5.
AJNR Am J Neuroradiol ; 35(1): 156-63, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23928145

RESUMO

BACKGROUND AND PURPOSE: Digital subtraction angiography is the reference standard technique to evaluate intracranial vascular anatomy and used on the endovascular treatment of vascular diseases. A dedicated optical flow-based algorithm was applied to DSA to measure arterial flow. The first quantification results of internal carotid artery flow validated with Doppler sonography are reported. MATERIALS AND METHODS: We included 22 consecutive patients who underwent endovascular procedures. To assess the sensitivity of the algorithm to contrast agent-blood mixing dynamics, we acquired high-frame DSA series (60 images/s) with different injection rates: 1.5 mL/s (n = 19), 2.0 mL/s (n = 18), and 3.0 mL/s (n = 13). 3D rotational angiography was used to extract the centerline of the vessel and the arterial section necessary for volume flow calculation. Optical flow was used to measure flow velocities in straight parts of the ICAs; these data were further compared with Doppler sonography data. DSA mean flow rates were linearly regressed on Doppler sonography measurements, and regression slope coefficient bias from value 1 was analyzed within the 95% confidence interval. RESULTS: DSA mean flow rates measured with the optical flow approach significantly matched Doppler sonography measurements (slope regression coefficient, b = 0.83 ± 0.19, P = .05) for injection rate = 2.0 mL/s and circulating volumetric blood flow <6 mL/s. For injection rate = 1.5 mL/s, volumetric blood flow <3 mL/s correlated well with Doppler sonography (b = 0.67 ± 0.33, P = .05). Injection rate = 3.0 mL/s failed to provide DSA-optical flow measurements correlating with Doppler sonography because of the lack of measurable pulsatility. CONCLUSIONS: A new model-free optical flow technique was tested reliably on the ICA. DSA-based blood flow velocity measurements were essentially validated with Doppler sonography whenever the conditions of measurable pulsatility were achieved (injection rates = 1.5 and 2.0 mL/s).


Assuntos
Angiografia Digital/métodos , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/fisiopatologia , Angiografia Cerebral/métodos , Circulação Cerebrovascular , Ultrassonografia Doppler/métodos , Velocidade do Fluxo Sanguíneo , Artéria Carótida Interna , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Neuroradiol ; 38(4): 232-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21353306

RESUMO

BACKGROUND: Carotid artery stenosis is associated with the occurrence of acute and chronic ischemic lesions that increase with age in the elderly population. Diffusion Imaging and ADC mapping may be an appropriate method to investigate patients with chronic hypoperfusion consecutive to carotid stenosis. This non-invasive technique allows to investigate brain integrity and structure, in particular hypoperfusion induced by carotid stenosis diseases. The aim of this study was to evaluate the impact of a carotid stenosis on the parenchyma using ADC mapping. METHODS: Fifty-nine patients with symptomatic (33) and asymptomatic (26) carotid stenosis were recruited from our multidisciplinary consultation. Both groups demonstrated a similar degree of stenosis. All patients underwent MRI of the brain including diffusion-weighted MR imaging with ADC mapping. Regions of interest were defined in the anterior and posterior paraventricular regions both ipsilateral and contralateral to the stenosis (anterior circulation). The same analysis was performed for the thalamic and occipital regions (posterior circulation). RESULTS: ADC values of the affected vascular territory were significantly higher on the side of the stenosis in the periventricular anterior (P<0.001) and posterior (P<0.01) area. There was no difference between ipsilateral and contralateral ADC values in the thalamic and occipital regions. CONCLUSIONS: We have shown that carotid stenosis is associated with significantly higher ADC values in the anterior circulation, probably reflecting an impact of chronic hypoperfusion on the brain parenchyma in symptomatic and asymptomatic patients. This is consistent with previous data in the literature.


Assuntos
Isquemia Encefálica/fisiopatologia , Encéfalo/irrigação sanguínea , Estenose das Carótidas/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Encéfalo/patologia , Encéfalo/fisiopatologia , Isquemia Encefálica/etiologia , Isquemia Encefálica/patologia , Estenose das Carótidas/complicações , Estenose das Carótidas/patologia , Circulação Cerebrovascular , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neuroimagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...